control unit. Various interfaces ensure that it always has access to the latest data. Features of the FAFNIR technology

Similar documents
VISY-X. Automatic Tank Gauging System. Sensors & Systems Worldwide:

VISY. Technical Documentation. VISY-Command (VI-4) Version: 6 Edition: Art. no.:

SECON-X. Technical Documentation. SECON-Lev User Guide. Version: 2 Edition: Art. No:

VISY-X. Technical Documentation. VISY-Monitor V 3.1. Edition: 03/2010 Version: 1 Article No.:

VISY-X. Technical Documentation. VISY-SoftView V 1.7 Administrator for VISY-Command GUI and VISY-View Touch

TLS4xx RELIABILITY, PERFORMANCE, EASE OF USE. Keeping the World Moving

veeder-root TLS-450 automated compliance and site management

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

LEVEL MONITOR AND MAGNETOSTRICTIVE TOP LEVEL CONSOLES LEVEL TRANSMITTER CE AND ATEX INTERSTITIAL AND COMPLIANCE. HIGH RESOLUTION 0,1 mm

WIRELESS REMOTE ASSET MONITORING & CONTROL

SECON-X. Technical Documentation. SECON-Vap Administrator. Version: 5 Edition: Art. No:

GRYF. Measuring Instruments. measuring electrochemical and physical values. monitoring the environment. controlling technological processes

Technical Documentation

PV System Monitoring for the FRONIUS IG Inverter Series

News on Gira's door communication system Gira DCS mobile mobile door communication system Gira DCS IP data interface Gira Project Assistant (GPA)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

VEGA II. Electronic counter. The solutions that count

VEGA SOFTWARE AND DISPLAY INSTRUMENTS

Grounding Monitoring Device Series 8485

DIAGNOSTICS PN# / / FSP

Grounding Monitoring Device Series 8485

Gallagher Vapour Recovery Monitoring

SC controller: One for all. The standard platform for all probes and analysers

High-end pressure controller Model CPC8000

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Fronius DATCOM. The data communication system for PV system monitoring

CONTROLS CONTROL PC 90/03 MODULAR CONTROLS SERIE PDC PPM-CONTROL-SYSTEM

Neon pr. ph/ ORP measurement. Applications. Description

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Operator's Quick Help

CONFIGURATION MANUAL MAGLINK LX

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

Make the sun your energy source. SOLAR

ECL Comfort V a.c. and 24 V a.c.

FC726 Fire control panel

L&J engineering s Wireless Systems. Wireless Level Gauging. company

/ Battery Charging Systems / Welding Technology / Solar Electronics. / Configuration guide

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Performance and Efficiency

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

METER REGISTER & DATA CONTROLLER

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Communicative. Adaptable. System and yield monitoring with SOLPLUS+ and SOLVOLT. Communicating with SOLPLUS Inverters

Modernisation package CAB 920

minimat-ec Cordless screwdriver

RENNERtronic Plus. higher-level controls. Made in Germany. RENNER compressor controllers. Efficient and reliable. Base load alternation switch K4 K4

Portable Density/Specific Gravity/Concentration Meter

System concept. Hardware DATA SHEET VECTRON POS TOUCH 12 II PCT

Trafoguard reliable monitoring of Transformer operating statuses. Transformer control

NEW. CAB 820 The basic measuring unit for perfect balancing Simple handling High measuring accuracy Future-proof concept. RC1057e

Signal conditioning instruments VEGASCAN 693. Product Information

IVS 2.0 Software Manual for Air, Vac & Water Machines

RS232, RS485. Connection and Operation of Digital Fuel Level Sensors

MINIMAT-EC-Servo Screwdriver Spindles

t-mac hardware a solution for all applications

SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM

VISY-X. Technical Documentation. Subsequent installation of VISY-Density. Edition: Version: 2 Art. No.:

Pneumatic precision pressure controller Model CPC6000

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

Serial Link Generic Tank Mode Installation Manual. Pro Fuel Management System. RE Rev C July 00

The Lumina has an astronomical clock and automatically adjusts for daylight savings time in order to provide accurate dusk to dawn lighting control.

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

TL100C Features: Real-time 1-touch data export 3rd party hosted & non-hosted applications

Dosing system for in-line mixing SD-XK / XKV

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Samsung CLP-670ND Colour Laser Printer The ultimate office assistant!

AS-i Safety Relay Output Module with Diagnostic Slave

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Hybrid-Video Recorder SISTORE MX DVD SISTORE MX

Hybrid-Video Recorder SISTORE MX DVD SISTORE MX

Product Specifications

Welcome to the Webinar

10.1 Multimedia Digital Poster

11. ELECTRICAL CONNECTION RS232C

FC724 Fire control panel

High-end pressure controller Model CPC8000

Tesseract. Technical Data sheet

FC722 Fire control panel

S-Vision. The Digital Video Surveillance System of Shuttle for Home and Office Applications

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display

IP Intercom Systems for Homes and Apartments

PC100 - Concept. Advantages in comparison

Distributed control system for medium to large power systems

ELECTRONIC AND CONTROL PROCESS DEVICES. reliability. professionalism. Company Profile.

TEMPERATURE DOCUMENTATION with KIRSCH-DATANET

System concept. Hardware DATA SHEET VECTRON POS TOUCH 15 II PCT

Pneumatic precision pressure controller Model CPC6000

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Enhanced insulation thickness. Environment friendly polyurethane foam, water based foaming.

Level monitoring system NT 2000 / 3500 series Selection list

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Fronius Solar Electronics - product overview

Pneumatic precision pressure controller Model CPC6000

Precision pressure indicator 1- or 2-channel version Model CPG2500

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Transcription:

The control unit The control unit contains the intrinsically safe power supply for the VISY-Stick sensors and their control unit. Various interfaces ensure that it always has access to the latest data. Up to 3 different VISY sensors can be connected to one terminal by a common cable Highly flexible thanks to modular architecture Easy to upgrade and retrofit IFSF-LON compatible Features of the FAFNIR technology Easy to configure thanks to free VISY-Setup software application Easy start-up The current firmware will be provided free of charge throughout the entire product life cycle (on request). Communication via Ethernet possible Free, user-friendly software for firmware updates Wireless communication of RF with VISY-Stick Sensors 25

Function description The control unit has a modular architecture. The internal components are modules for DIN rail installation that can be retrofitted or converted at any time. is available in the form of basic versions 8 and 16, i. e. with either 2 / 4 / 8 or 16 sensor connections. Up to 3 different sensors (e. g. VISY-Stick, VISY-Stick Interstitial and VISY- Stick Sump) can be connected to one terminal by a common cable. The control unit is also available in the form of RF; this supports the wireless operation of up to 16 VISY-Stick sensors. provides an intrinsically safe power supply for the VISY-Stick sensors. The measured values supplied are prepared in such a way that all of the latest measurement data can be viewed at any time on a superordinate system (e. g. cash system, petrol station controller, VISY-Monitor PC software...) connected to a serial port. Data transmission is supported by various, common data protocols, e. g. Ethernet and IFSF-LON. The extension interface of VISY- Command enables multiple external VISY-View Touch displays (e.g. fuel tanker display and local display in the office) to be connected and positioned where they can be seen and operated by personnel at all times. itself can be fitted in a location that achieves the most cost-effective cabling arrangement (e.g. power distribution unit or basement). By contrast with systems having an integrated display, the major advantage of our system is that it is not necessary to have all of the sensor cabling routed though the building to the viewing point (e.g. the office). The VISY-ICI 485 interface makes it possible to connect multiple VISY-Input/- Output units. These enable the inputting (VISY-Input) of additional external alarms (e.g. oil separators) and/or the outputting (VISY-Output) of alarms by way of relay contacts. is configured using the VISY-Setup software application through the separate serial service port. As a result, practically all maintenance and diagnostics tasks can be carried out while the entire system is still in operation. It is not necessary to switch off individual components: petrol station operations are not affected. VISY-Setup is free of charge and, in addition to offering user-friendly and efficient direct configuration by notebook, it also supports remote servicing via a modem or serial-to-ethernet converter. 26 Function

Design Housing Casing protection up to 8 sensor terminals and RF version: H 300 x W 300 x D 125 IP20 16 sensor terminals: H 300 x W 400 x D 175 Weight 5.7 kg 9.7 kg Ambient temperature 0 C to + 40 C Supply Internal display 230 V AC ± 10 %, approx. 15 VA or 23 VA ( 16) 7-segment status indicator Number of sensor terminals 2, 4 or 8 16 Host interface (RS232 / RS485) IFSF-LON module Service interface (RS232) Extension interface (RS485) VISY-View Touch display VISY-ICI 485 module VISY-Output (relay outputs) VISY-Input (digital switch inputs) Printer (1) (1) (1) (1) (1) (2) (2) (2) (3) (external)* * only in connection with VISY-View Touch Functions Communication with the PoS / BOS system or petrol station controller Automatic filler recognition Automatic tank calibration (4) Loss / leak monitoring (5) Stock, filling and alarm histories (5) (1) Alternatively, one of the available options can be used at the interface concerned. (2) Multiple available options can be used simultaneously at the interface concerned. (3) In conjunction with VISY-View Touch. (4) In conjunction with VISY-Monitor and a compatible cash system/ automatic fuel dispenser. (5) In conjunction with VISY-Monitor. Design 27

GUI The control unit with a graphic display GUI with printer Instant alarm message via e-mail Daily report via e-mail Static leak detection GUI contains the intrinsically safe power supply for the VISY-Stick sensors and their control unit. Various interfaces ensure that it always has access to the latest data. The integrated display unit with the 5.7 colour touch screen provides and displays the current measurement values and the reporting functions (log file) in a user-friendly form. The GUI has a display with a clearly structured and easy to operate interface. The most important information, e.g. tank level and alarms are displayed directly and upto-date on the screen. Using the touch screen, operators can call up detailed information simply by touching the tank graphics or the function keys. Up to 3 different sensors can be connected to one terminal by a common cable. Up-to date overview of the tank contents shown at a graphic display Convenient tank content visualization with useful additional data, e.g. ullage Features of the FAFNIR technology Display of the tank contents in litres, with or without temperature compensation Display of product temperature and water level Highly flexible due to modular architecture Easy to upgrade and retrofit Precise configuration using the free software VISY-Setup Easy start-up Communication via Ethernet possible Free, user-friendly software for firmware updates Integrated alarm signal Wireless communication of GUI RF with VISY-Stick Sensors Optional with printer 28 GUI

Function The display of the GUI visualises the data provided by the FAFNIR sensors. All of the relevant data related to the tank (tank number and product name), the product (level, water level and product temperature) and various additional data (e.g. ullage) are displayed. The tank information displayed is continuously refreshed and viewable at all times. Fuel deliveries and tank alarms are archived additionally in a database. The display board is operated by a touch screen. Special attention was given to ergonomics when determining the size of the function keys. If required, all of the displayed tank information can be printed out using the integrated printer (option). Moreover, obligatory print-outs for alarm messages are possible. An audio warning sounds in addition to tank alarms. Data Management Volumetric display of tank contents Temperature-compensated volume Product temperature Ullage Tank and product name Water level Variable number of displayed tanks (16 tanks maximum) Alarm messages and logging History records (delivery data and alarms) Archiving of delivery data and alarms in a database Design Housing Casing protection Up to 8 sensor terminals: H 300 x W 300 x D 175 GUI IP20 16 sensor terminals: H 300 x W 400 x D 175 Weight 6.7 kg 10.7 kg Ambient temperature 0 C to +40 C Supply Internal display 230 V AC ± 10 %, approx. 50 VA 5.7 TFT touch screen Number of sensor terminals 2, 4 or 8 16 Host interface (RS232 / RS485) Service interface (RS232) Extension interface (RS485) VISY-View Touch display VISY-ICI 485 module VISY-Output (relay outputs) VISY-Input (digital switch inputs) Printer Functions Communication with the PoS / BOS system or petrol station controller Automatic filler recognition Static leak detection GUI GUI Design 29