Start-up Guide. AF 100 Adapter Kit NAFA-01

Similar documents
ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual I/O Module Adapter AIMA-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter

115/230 VAC Digital Input Module OHDI-01

User s Manual Pulse Encoder Interface Module OTAC-01

Industrial IT. General Information and Installation. 800xA - Control and I/O S800 I/O. Version 4.1

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor Start-up Guide DeviceNet Adapter Module NDNA-02

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

ABB wind turbine converters. Supplement ACS slide-out frame (+P919)

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

S800 I/O ABB Automation

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

ABB industrial drives. Safety instructions ACS880 multidrive cabinets and modules

- Alii -,..., ~~~~~~~~'-~" ..., ,..- ))) --t ..., )(1. User s manual FEPL-02 Ethernet POWERLINK adapter module. IIIIIJ!ll"

ABB Drives. Installation and Start-up Guide. ControlNet Adapter Module NCNA-01

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

To connect the AC adapter:

Model 2380 Rack-Mount Kit

Dimensional drawings. Dimensional drawings

RER 123 Bus Connection Module. Technical Description

Operating instructions Evaluation system for flow sensors VS / / 2013

Control IT S800 I/O System

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PTC/PT100 board 2.0 Option

Installation Notes TII Model 341 Protector

ControlNet Comm Glass Fiber Adapter Kit

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

PTC/PT100 board 2.0 Option

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MicroTech III Water Source Heat Pump BACnet MS/TP Communication Module


CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

Replacing the Power Supply

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PROCESSELEKTRONIK AB Copies to-kopior till

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

PTC/PT100 board 2.0 Option

Rako RAK4-R Instruction Manual

Model 2380 Rack-Mount Kit

Control IT AC 800C Controller

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Tap Manager TM100. Operating Instructions

LF3-400 Three Phase Frequency Converter, Operation and Maintenance.

Start-up Guide DeviceNet Adapter Module CFB-DEV

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

AC 800M for Compact Product Suite Outline of all modules

PROCESSELEKTRONIK AB Copies to-kopior till. DCU30M Desk Control Unit

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Operating instructions. Switching amplifier DN0210 DN / / 2015

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Analog Input Installation Manual

MDM 011-Z1 Regen Resistor

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module


Analog Monitor Installation Manual

SREDU Double Connection Option Card for Lon Star Coupler RER 111

Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER

SynchLink Board for PowerFlex 700S Drives with Phase II Control

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

PM Series Power Meter

Operating instructions. Speed monitor D / / 2014

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4.

Installing Sentor. Hardware Installation

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd Page 1 of 10 Revision 03

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

PIX 520. PIX 520 Product Overview CHAPTER

PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

EAP 300 REMOTE ANNUNCIATOR INSTALLATION MANUAL. r.0454a

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MODIFYING THE ACS355 UL TYPE 4X FOR MXXX OPTIONS

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Single-Core PVC 6491X

Transcription:

ABB Drives Installation and Start-up Guide AF 100 Adapter Kit NAFA-01

AF 100 Adapter Kit NAFA-01 Installation and Start-up Guide 3BFE 58919837 R0125 EFFECTIVE: 17.07.2000 SUPERSEDES: None

Safety Instructions Overview Warnings and Notes Warnings This chapter states the safety instructions that must be followed when installing and operating the NAFA-01 AF 100 Connection Kit. The material in this chapter must be studied before attempting any work on, or with, the unit. This manual distinguishes two sorts of safety instructions. Warnings are used to inform of conditions which can, if proper steps are not taken, lead to a serious fault condition, physical injury and death. Notes are used when the reader is required to pay special attention or when there is additional information available on the subject. Notes are less crucial than Warnings, but should not be disregarded. Readers are informed of situations that can result in serious physical injury and/or serious damage to equipment with the following symbols: Dangerous Voltage Warning: warns of situations in which a high voltage can cause physical injury and/or damage equipment. The text next to this symbol describes ways to avoid the danger. General Warning: warns of situations which can cause physical injury and/or damage equipment by means other than electrical. The text next to this symbol describes ways to avoid the danger. Electrostatic Discharge Warning: warns of situations in which an electrostatic discharge can damage equipment. The text next to this symbol describes ways to avoid the danger. Notes Readers are notified of the need for special attention or additional information available on the subject with the following symbols: CAUTION! Note: Caution aims to draw special attention to a particular issue. Note gives additional information or points out more information available on the subject. NAFA-01 Installation and Start-up Guide i

Safety Instructions General Safety Instructions WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians. The drive and adjoining equipment must be properly earthed. Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working with the unit. Neglecting these instructions can cause physical injury and death. WARNING! There are several automatic reset functions in the drive. If selected, they reset the unit and resume operation after a fault. These functions should not be selected if other equipment is not compatible with this kind of operation, or dangerous situations can be caused by such action. More Warnings and Notes are printed at appropriate instances along the text. ii NAFA-01 Installation and Start-up Guide

Table of Contents Safety Instructions Overview....................................................................... i Warnings and Notes.............................................................. i General Safety Instructions......................................................... ii Table of Contents NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Related Publications..............................................................1 Terms and Definitions.............................................................1 NAFA-01 AF 100 Adapter Kit.......................................................2 CI810 (FCI)...................................................................3 Status LEDs................................................................4 TB810/TB811 Optical ModuleBus Port..............................................4 Status LEDs................................................................4 TC505 Connection Unit.........................................................5 Compatibility..................................................................5 Warranty and Liability Information.................................................5 Installation and Configuration.......................................................6 Power Supply Connection.......................................................7 Non-redundant Connection....................................................7 Redundant Connection.......................................................7 AF 100 Bus Connection.........................................................8 FCI Address Setting..........................................................8 Drive Connection..............................................................9 Drive Configuration............................................................10 Activation of Communication..................................................10 Communication Speed......................................................10 DDCS Node Address........................................................10 Advant Controller Configuration..................................................11 NAFA-01 Installation and Start-up Guide iii

Table of Contents iv NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Related Publications Advant Fieldbus 100 User s Guide (English: 3BSE 000 506)* S800 I/O User s Guide (English: 3BSE 008 878)* The drive documentation. *Issued by and available from ABB Automation Products, Västerås, Sweden. Terms and Definitions AdvaBuild (for Windows) Advant Fieldbus 100 (AF 100) DDCS FCI (S800) I/O Cluster (S800) I/O Device (S800) I/O Module A package of programming tools. A twisted pair fieldbus that provides communication between Advant Controllers, I/O stations and higher-level computer systems. Further information is obtainable from the Advant Fieldbus 100 User s Guide (English, 3BSE 000 506; available from ABB Automation Products, Västerås, Sweden). Distributed Drives Communication System; a communication protocol used in fibre optic links in ABB drives. A name used in this manual for the CI810 AF 100 Fieldbus Communications Interface. An extension of the ModuleBus optical link. Consists of a ModuleBus modem (type TB820) with S800 I/O devices. A complete I/O device consists of one MTU and one I/O module. The active, electronic, and signal conditioning part of an I/O device. (S800) I/O Station An I/O station consists of an FCI, 1 to 7 I/O clusters with up to 24 I/O devices. ModuleBus (S800) MTU S800 I/O An incremental, electrical or optical bus for interconnection of I/O devices. Module Termination Unit; a passive unit onto which an I/O module is mounted. The MTU contains the process I/O terminals and part of Electrical ModuleBus. Range of distributed modular I/O units that communicate with Advant Controllers over an AF100 bus. NAFA-01 Installation and Start-up Guide 1

ACS 600 ACS 600 ACS 600 NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide NAFA-01 AF 100 Adapter Kit The NAFA-01 AF 100 Adapter Kit contains the components required for connecting ABB drives to a twisted-pair AF 100 bus. The kit consists of the following components: CI810 AF 100 Fieldbus Communications Interface (FCI) TB810 and TB811 ModuleBus Optical Ports TC505 Connection Unit 2 pcs 2-metre plastic (POF) fibre optic cables this manual. With the NAFA-01, it is possible to Connect up to 24 ABB drives to an AF 100 twisted-pair bus Give control commands (such as Start, Stop, Run enable) to the drive(s) Feed a motor speed or torque reference to the drive(s) Give a process actual value or a process reference to the PID controller of the drive(s) Read status information and actual values from the drive(s) Reset a drive fault Connect S800 I/O modules to an AF 100 bus. For detailed information on the installation and use of S800 modules, see the S800 I/O User s Guide. The following figure presents the connection of ABB drives to an AF 100 bus using the components included in the NAFA-01 kit. AC400 Series Controller 1 24 ABB Drive(s) *CI810 Fieldbus Comm. Interface (FCI) Other devices *Fibre optic cables *TB810 or *TB811 Optical ModuleBus Port AF 100 *TC505 Connection Unit *Included in NAFA-01 2 NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide CI810 (FCI) The CI810 AF 100 Fieldbus Communication Interface (hereafter referred to as the FCI) is the main component of the NAFA-01. When connected to the AF 100 bus, the FCI forms an S800 I/O station. For connection of S800 I/O modules or ABB drives, the FCI provides ModuleBus, which is divided into electrical and optical busses. Electrical ModuleBus can be used for connecting up to 12 S800 I/O modules. The Optical ModuleBus link can contain 24 I/O devices (drives or S800 I/O modules) in up to 7 I/O clusters, but the maximum number of I/O devices on both ModuleBusses combined is 24. Note: Drives that are specified in the Advant Controller program using the DRIENG database element i.e. engineered drives count as two devices. (Drives using the DRISTD element i.e. standard drives are each considered one device.) Thus this rule is applicable: 2 (NO. OF ENGIN D DRIVES) + (NO. OF STD DRIVES) + (NO. OF S800 I/O DEVICES) 24 84 mm 122 mm F T1 R P T2 Electrical ModuleBus connector (on the side of the unit). For connection of up to 12 devices (S800 I/O modules). Status LEDs. 170 mm SERVICE L+ L+ SA L- L- SB CI810A AF100 1 2 + - STN. ADDR. 4 5 6 3 7 x 10 2 8 1 0 9 4 5 6 3 7 x 1 2 8 1 0 9 + - Tx Rx Tx AF 100 Station Address selectors. Connector for TB81x Optical ModuleBus Port (covered by a lid). For connection of maximum 24 devices (drives or S800 I/O modules). Rx AF 100 connectors. Power supply connectors. Figure 1 The CI810 (FCI). NAFA-01 Installation and Start-up Guide 3

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Status LEDs LED Colour Description F (Fault) Red Module fault. This LED will also light at module start-up and is turned off after a successful self-test. R (Run) Green Operational state. P (Power OK) Green Internal power OK. T1 (Traffic 1) Yellow Data traffic on AF 100 cable 1. T2 (Traffic 2) Yellow Data traffic on AF 100 cable 2. TB810/TB811 Optical ModuleBus Port The FCI requires a TB81x optical port to provide a fibre optic connection. The maximum communication speeds of the TB810 and TB811 are 10 Mbit/s and 5 Mbit/s respectively. Note: The communication speed on the fibre optic link is always 4 Mbit/s regardless of which optical port type is used. As all optical components on a fibre optic link must be of the same type for the light intensity and receiver sensitivity levels to match, choose the appropriate TB81x Optical ModuleBus Port to be used according to the optical component type used in the drive to be connected. Plastic (POF) cables such as those included in the NAFA-01 kit can be used with both 5 Mbit/s and 10 Mbit/s optical components. Hard Clad Silica (HCS) cables can be used with 10 Mbit/s components only. The recommended cable lengths are as follows: Cable Type TB811 Optical Port Type TB810 POF 2 10 m 2 30 m HCS 2 200 m Status LEDs The TB81x has two LEDs, labelled Tx and Rx, that indicate data being transmitted and received respectively. 4 NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide TC505 Connection Unit When connecting the FCI to the AF 100 bus, the incoming and outcoming cables can either be connected directly to the AF 100 terminals of the module, or a TC505 Connection Unit can be used. The TC505 is typically used when the I/O station is installed in a cabinet. The TC505 has no internal capacitive decoupling between the shield and earth, and is intended for use within a cabinet which itself has a separate capacitive coupling. + + + + Figure 2 TC505 internal connections. Compatibility Warranty and Liability Information The NAFA-01 can be used in conjunction with the following ABB drives: ACS 400 ACS 600 with Standard, System, Motion Control, Pump and Fan Control, or Crane Application Program DCS 400 DCS 500 DCS 600. See the drive documentation for warranty information. NAFA-01 Installation and Start-up Guide 5

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Installation and Configuration WARNING! Before installation, switch off the drive power supply. Wait five minutes to ensure that the capacitor bank of the drive is discharged. Switch off all dangerous voltages connected from external control circuits to the inputs and outputs of the drive. Follow the installation instructions given in the S800 I/O User s Guide. The FCI and the TC505 can be installed on a horizontal or vertical DIN mounting rail. The earth of the FCI module is connected to the mounting rail by means of an earthing tab. The mounting rail onto which the option module is to be mounted must be earthed to a noiseless earth. If the rail is not mounted on a properly earthed base, a separate earthing conductor must be used. The conductor must be made of minimum 6mm 2 stranded wire and kept as short as possible. The FCI is cooled by natural convection. Ensure that the ventilation slots on the module are not blocked. Avoid placing the module directly above heat-generating components. 6 NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Power Supply Connection The power supply terminal headers accept wire sizes from 0.2 to 2.5 mm 2 (24 to 14 AWG). The terminal designations are as follows: X1A Designation Description 1 L+ +24 V (in) X1A L+ L+ SA L- L- SB 1 + - 2 + - Tx 2 L+ +24 V (out) 3 SA Redundant power supply monitor input X1B Rx X1B Designation Description 1 L 0 V (in) 2 L 0 V (out) 3 SA Redundant power supply monitor input Non-redundant Connection X1A 1 2 3 1 2 3 X1B +24 V /A 0 V *Forwarded Power *If the forwarded power needs to be independent of whether the power plugs are inserted or not, bridge terminals 1 and 2 on both plugs. Redundant Connection With this connection, the FCI can be used for monitoring both power supplies. X1A 1 2 3 1 2 3 X1B Power Voter Unit Supervision *Forwarded Power +24 V /A +24 V /B 0 V *If the forwarded power needs to be independent of whether the power plugs are inserted or not, bridge terminals 1 and 2 on both plugs. NAFA-01 Installation and Start-up Guide 7

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide AF 100 Bus Connection The AF 100 bus cables can be connected to the CI810 either directly or through the TC505 Connection Unit. Diagrams are presented below for both cases. The diagrams illustrate non-redundant cabling for single bus cable only. For instructions on redundant connection of two bus cables, refer to the Advant Fieldbus 100 User s Guide. Arrange the bus cables as far away from power cables as possible. Avoid parallel runs. Use bushings at cable entries. Direct bus connection (without the TC505 Connection Unit) _ + 1 2 3 4 Terminal Header (to FCI AF 100 connector #1) +_ Twisted Pair Trunk Cable Twisted Pair Trunk Cable +_ Wiring using the TC505 Connection Unit _ + 1 2 3 4 Terminal Header (to FCI AF 100 connector #1) Twisted Pair Tap Cable + + TC505 Connection Unit + + Twisted Pair Trunk Cable Twisted Pair Trunk Cable +_ +_ FCI Address Setting The address selectors on the FCI are used to define an individual address for the module on the AF 100 bus segment. The setting must be in the range of 1 to 79. 8 NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Drive Connection The FCI is connected to the drive (or branching unit) with a pair of fibre optic cables. For fibre optic connection, the FCI requires a TB81x Optical ModuleBus Port fitted. Use the flat of a screwdriver to remove the protective lid at the lower right-hand part of the FCI base. Insert the TB81x into the bay until the retaining clips click into place. Tx Rx Tx Rx Rx Rx Tx Tx Figure 3 (Left) Removing the protective lid of the TB81x bay. (Right) TB81x Optical ModuleBus Port inserted. Route the fibre optic cables from the TB81x Optical ModuleBus Port to the drive. Consult the drive documentation as to the corresponding terminals inside the drive. Observe the connector colour coding: blue connectors should go to blue receivers, grey (or black) connectors to grey transmitters. Multiple (up to 24) drives can be connected in a ring. A star topology can be achieved using DDCS Branching Units; consult your local ABB representative for information. Handle fibre optic cables with care. When unplugging optic cables, always grab the connector, not the cable itself. Do not touch the ends of the fibres with bare hands as the fibre is extremely sensitive to dirt. The maximum long term tensile load for the fibre optic cables is 1 N. The minimum short term bend radius is 25 mm. Use grommets at cable entries. Tx Rx Rx DDCS T R Tx ABB Drive Figure 4 Fibre optic link connecting the FCI to the drive. NAFA-01 Installation and Start-up Guide 9

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide Drive Configuration Activation of Communication Communication Speed After the components of the NAFA-01 kit have been installed according to the above instructions, the drive must be prepared for communication with the FCI and the Advant Controller. The detailed procedure of activating the communication between the drive and the NAFA-01 is dependent on the drive type. Normally, a parameter must be adjusted to activate the communication; see the drive documentation. Set the communication speed on the drive to 4 Mbit/s. Note: The communication speed on the fibre optic link is always 4 Mbit/s regardless of which type of optical port is used. DDCS Node Address All devices on the Optical ModuleBus must have a distinctive address (device number). Allowable addresses are shown in the table below. If there are S800 I/O clusters on the link, they reserve all 12 addresses allocated for that cluster, regardless of how many I/O devices the cluster contains. A drive can use any address from the remaining free cluster address ranges. See Figure 5. Cluster Address Range 1 101 to 112 2 201 to 212 3 301 to 312 4 401 to 412 5 501 to 512 6 601 to 612 7 701 to 712 The drive has a parameter for setting the node address. See the drive manuals for more information. Note: For ABB drives, the actual setting for the node address parameter is calculated by multiplying the hundreds by 16, then adding the tens and ones to the result. For example, address 201 is set at the drive node address parameter as 2 16 + 1 = 33. 10 NAFA-01 Installation and Start-up Guide

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide FCI (CI810) TB807 ModuleBus Terminator AF 100 TB810 ModuleBus Optical Port S800 I/O Devices (Reserve addresses 1 to 12) Duplex fibre optic cable TB820 ModuleBus Modem (Cluster Address: 1) Cluster 1 Reserves addresses 101 to 112 TB820 ModuleBus Modem (Cluster Address: 2) Cluster 2 Reserves addresses 201 to 212 ACS 600 Drive Available addresses: 301 to 312; 401 to 412; 501 to 512; 601 to 612; 701 to 712 Figure 5 An example of device addressing on an Optical ModuleBus link. Advant Controller Configuration Please refer to the S800 I/O User s Guide and the documentation of the Advant Controller for information on configuring the Advant system for communication with the NAFA-01. NAFA-01 Installation and Start-up Guide 11

NAFA-01 AF 100 Adapter Kit Installation and Start-up Guide 12 NAFA-01 Installation and Start-up Guide

NAFA-01/EN 3BFE 58919837 R0125 EFFECTIVE: 17.07.2000 SUPERSEDES: NONE ABB Industry Oy Drives P.O.Box 184 FIN-00381 Helsinki FINLAND Telephone: +358 10 222 000 Fax: +358 10 222 2681 Internet: www.abb.com/automation ABB Automation Inc. Drives 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone: 262 785-3416 800 243-4384 Fax: 262 785-8525 Internet: www.abb-drives.com