EMOSAFE EN-30 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Gigabit Network Isolator in aluminium housing December 2015 ENGLISH

Similar documents
High Performance Network Isolator

EMOSAFE EN-10 Network Isolators with Protected Connector

EMOSAFE EN-100 Network Isolators for PCB assembly

EMOSAFE EN-85e Network Isolator with Overtension Auto-Release

With the exception of EN-70e, which provides a dielectric strength of only 4.6 kv AC, and does not provide any transient voltage suppression.

EMOSAFE EN-60KDS 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Keystone Network Isolator with Cable December 2015 ENGLISH

EMOSAFE EN-65 Installation Network Isolators with Integrated Cable

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

MED MI 1005 Network Isolators

Safety Standards. Model Number:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number: Unit Weight:

Safety Standards. Model Number:

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

UL TEST REPORT AND PROCEDURE

Safety Standards. Model Number:

Safety Standards. Model Number:

Safety Standards. Model Number:

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

UL TEST REPORT AND PROCEDURE

TU531, TU532 Terminal Unit

Operating instructions. Standstill monitor A / / 2011

MC 11 EB-2 Power supply cabinet with external bus, AC version

UL TEST REPORT AND PROCEDURE

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

C B. Models. Operating up to 5000m altitude 5 year product warranty

UL TEST REPORT AND PROCEDURE

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

TF501, TF521 Terminal Bases

AI561 Analog Input Module

AO561 Analog Output Module

Enclosed Power Supplies

Datasheet - SRB 402EM-24V

030AAC Highlights & Features

UL TEST REPORT AND PROCEDURE

AO523 Analog Input Module

NI Serial Hardware Specifications Guide

CM597 Ethernet Communication Module

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

CM579-PNIO PROFINET Communication Module

DI561 Digital Input Module

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

DC561, digital input/output module,

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

38 MHz Passive Voltage Probe R&S RT-ZP1X

UL TEST REPORT AND PROCEDURE

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Features. Applications and Benefits TRC ELECTRONICS, INC

UL TEST REPORT AND PROCEDURE

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

DI572 Digital Input Module

CM589 PROFINET Communication Module

Output Voltage* (nom.)(adjustable)

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

DC562, digital input/output module,

Signal Doublers. VariTrans A 20300

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

Safety Standards. Model Number:

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

CM589 PROFINET Communication Module

PCT2000. User Manual. Precision current transducer 2000 A

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

CM592 PROFIBUS Communication Module

DX561 Digital Input/Output Module

Operating instructions. Switching amplifier DN0210 DN / / 2015

Output Voltage* (nom.)(adjustable)

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

AX522 Analog Input/Output Module

Operating Instructions

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

TM241CE24T controller M IO transistor PNP Ethernet

Operating instructions. Speed monitor D / / 2014

MINI-PS AC/10-15DC/8

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Datasheet - MZM 100 B ST-1P2PW2REM-A

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

DC541 Digital Input/Output Module

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

Transcription:

ENGLISH EMOSAFE EN-30 Product Datasheet Gigabit Network Isolator in aluminium housing December 2015 1 FEATURES AND ADVANTAGES Gigabit Ethernet Hardwearing aluminium housing Optionally usable mounting bracket UL Recognized Component RoHS compliant 4 kv AC dielectric strength 5.6 kv DC dielectric strength IEC 60601-1 compliant (3 rd Edition) 100% inspection by our Quality Control 2 GENERAL DESCRIPTION EMOSAFE EN-30 Network Isolators disconnect every electrically conducting connection (specifically the data and shield conductors) between devices connected together via a copper-based Ethernet network. The Network Isolators prevent current flow resulting from differences in electrical potentials, and also protect connected devices and their users from stray external voltages and power surges which may be directly or inductively coupled onto the network lines by causes such as installation errors, lightning, switching operations, and electrostatic discharge. Built into a medical electrical (ME) product, the EMOSAFE EN-30 Network Isolator facilitates the safe Ethernet connection of this ME product within the patient environment. The EN-30 satisfies all construction requirements of IEC 60601-1 (3 rd Edition) in the formation of two means of patient protection (MOPP) within the network interface, thereby practically eliminating the risk of electrical shocks arising from such stray external voltages at the network connection. PD1100-V20 Page 1 of 12 2015 EMO Systems GmbH

The EN-30 has an elegant and hardwearing aluminium housing. Included with the EN-30 are four selfadhesive rubber feet which, when attached to the underside of the housing, ensure a secure grip on smooth surfaces. Also included is an aluminium mounting bracket, which permits the screwing of the EN-30 to a wall or to a device panel. The EN-30 is further distinguished by its gigabit Ethernet capability, and also by its robust construction. As a UL Recognized Component, the EN-30 Network Isolator is also suitable for inclusion in systems destined for export in the North American markets. EMOSAFE Network Isolators transmit high-frequency signals through the principle of electromagnetic induction. Because of this, they do not require their own power supplies. There are no software drivers to be installed. 3 APPLICATIONS 3.1 PATIENT PROTECTION Electrical separation of Ethernet interfaces of medical electrical (ME) devices and systems, where patients must be protected from dangerous leakage currents, in conformity with applicable standards. 3.2 EQUIPMENT PROTECTION Applications, in which valuable devices or those requiring special protection need to be protected against ripple, mains hum, and surge voltages from the network periphery. 3.3 MEASUREMENT TECHNOLOGY Electrical measuring and monitoring equipment, which needs to be protected against external voltages and interference voltages arising from the Ethernet periphery. 3.4 AUDIO Audio applications, in which the transmission of low frequency alternating current voltages (mains hum) over the network connection is to be reduced to an imperceptible level. PD1100-V20 Page 2 of 12 2015 EMO Systems GmbH

4 TECHNICAL DRAWINGS 4.1 TECHNICAL DRAWINGS: EN-30 All dimensions in mm. Figure 1. Dimensions of EN-30 with mounting bracket PD1100-V20 Page 3 of 12 2015 EMO Systems GmbH

Figure 2. Assembly of the mounting bracket (included) 5 INSTALLATION INFORMATION Figure 3. Dimensions of EN-30 with self-adhesive rubber feet (included) 5.1 GENERAL EN-30 Network Isolators are designed for data transmission in the frequency range of 300 khz to 100 MHz. Lower frequencies are strongly attenuated. For this reason, it is generally not possible to transmit the signals from nurse call systems, telephone systems or analogue audio / video signals over a Network Isolator. PD1100-V20 Page 4 of 12 2015 EMO Systems GmbH

The EN-30 Network Isolator can be used in a Power over Ethernet (PoE) network without restriction (however PoE devices downstream of the electrical isolation are not supplied with power). A PoE Injector can be installed to supply downstream devices, however it is critical that this power supply meets or exceeds all applicable medical electrical requirements, in order to maintain the effectivity of the Network Isolator. 5.2 EQUIPMENT INSTALLATION When designing Network Isolators into equipment or devices, it is essential that the manufacturer observes the applicable creepage and clearance distances. Specifically, the creepage and clearance distances between exposed metal surfaces of Ethernet patch cables plugged into the Network Isolator, and the next-closest electrically conducting components of the equipment or device to be protected. The requirements of IEC60601-1 are particularly relevant. 6 SAFETY NOTICE During assembly, attention should be paid (when applicable) to ensure that the clearance and creepage distances required by IEC 60601-1 are met. The isolating effect of the Network Isolator must not be compromised by neighbouring conductive components. If, for example, the installation of the Network Isolator is to be within a metal plate, this plate must be connected to the ground potential (protective earth). As a matter of principle, Network Isolators should be mounted as close as possible to the equipment requiring protection. Damaged Network Isolators, and Network Isolators which are contaminated by dust or liquids, are to be replaced. 7 FUNCTION AND SAFETY TESTS 7.1 FUNCTION AND COMPLIANCE TESTS A cable run equipped with an EN-30 Network Isolator can be checked with regard to its transmission characteristics using cable certification devices which are suitable for testing an electrically isolated cable run. To be able to conduct such an inspection, the test equipment must be configured in an AC wire-map mode. With the installed Network Isolator, the entire cable run can be approved according to EIA/TIA- 568 Cat.5e or ISO 11801 Class C. Testing of the cable shielding and the individual conductor resistance is not possible in such an AC test mode. 7.2 SAFETY INSPECTIONS Regular safety inspections and post-repair inspections are not prescribed for Network Isolators in medical use, as Network Isolators themselves are not classified as medical electrical (ME) devices. However, together with a connected ME device, Network Isolators form part of an ME system, which altogether may be subject to statutory inspection. The test interval, as well as the requirements to be met for both regular safety inspections and post-repair inspections will be specified by the responsible organisation (e.g. manufacturer or operator as defined by the regulations), and based upon the applicable standards for the entire ME system. To simplify implementation, the individual components of the ME system (in this case, the Network Isolator) can be tested separately. Here as well, the responsible organisation specifies the test parameters, PD1100-V20 Page 5 of 12 2015 EMO Systems GmbH

test interval and in the event of a failed test, the consequences. Depending on the requirement profile, the test can include one or more of the following individual tests: 7.2.1 VISUAL INSPECTION Check for evidence of external damage and ingress of substances; dust or liquids for example. 7.2.2 LEAKAGE CURRENT TEST It is to be checked if the measured leakage current is still within the prescribed limits. For this purpose, test equipment which can perform equipment leakage current measurements in accordance with IEC 62353 may be used. To perform a leakage current test, all conductors on the input side must be shortcircuited together, and all the conductors on the output side must also be short-circuited together. The AC test voltage specified by the responsible organisation is then applied across these two connections. Input and output sides are interchangeable. The expected current flow can be found in section 8 SPECIFI- CATIONS. 7.2.3 HIPOT TEST To ensure that the device under test is not damaged, it is recommended that a DC voltage source is used in place of the AC voltage source, and that the DC voltage is 1½ times that of the required AC voltage. The test setup is essentially the same as that of the Leakage Current Test above. The expected dielectric strength can be found in section 8 SPECIFICATIONS. 7.2.4 FUNCTIONAL TEST After conducting the tests above, and reconnecting the Network Isolator into the Ethernet network, it is recommended to check whether the signal transmission is still performing correctly. Such a functional test can be performed, for example, with a suitable Ethernet cable certification device. See also section 7 FUNCTION AND COMPLIANCE TESTS. PD1100-V20 Page 6 of 12 2015 EMO Systems GmbH

8 SPECIFICATIONS 8.1 GENERAL Category Standards or Test Criteria Properties Designation Housing colour Housing Material Construction Mounting Arrangement Input Interface Output Interface Weight EMOSAFE EN-30 Black and silver Plastic and aluminium Self-Enclosed Screws Protection rating EN 60529 IP40 Mating cycles Mean Time To Failure (MTTF) 8.2 ETHERNET PERFORMANCE RJ45 plug mating and disconnecting from RJ45 socket SN 29500 Standard Temperature: 25 C Duty cycle: 100% (24 hours, 7 days) SN 29500 Standard Temperature: 40 C Duty cycle: 100% (24 hours, 7 days) RJ45 Jack, straight RJ45 Jack, straight approximately 75 g > 250 cycles 4,590 years 4,260 years Category Standards or Test Criteria EN-30 Transmission Speeds and Supported Network Protocols 10 Mbit/s, 10Base-T (IEEE802.3 Cl.14) 100 Mbit/s, 100Base-Tx (IEEE802.3 Cl.25) 1000 Mbit/s, 1000Base-T (IEEE802.3 Cl.40) * Performance Category ISO 11801, Permanent Link (PL) Class C Insertion Loss (absolute) Return Loss (absolute) Typical: Maximum: Typical: Minimum: 1.5 db @ 100 MHz 2.0 db @ 100 MHz 8.0 db @ 100 MHz 6.0 db @ 100 MHz * Transmission speeds of 1 Gbit/s are generally easily achievable with high-quality cabling and modern Ethernet network cards. For standard-compliant signal paths at 1 Gbit/s, or for critical applications, we recommend utilising Network Isolators that satisfy the requirements of ISO 11801 Permanent Link Class D. PD1100-V20 Page 7 of 12 2015 EMO Systems GmbH

8.3 ELECTRICAL Category Standards or Test Criteria EN-30 AC Dielectric Strength at 50 Hz, for 60 seconds 4.0 kv DC Dielectric Strength for 60 seconds 5.6 kv Reinforced Isolation IEC 60601-1 Coupling Capacitance per Channel 12 pf ±25% Total Coupling Capacitance 48 pf ±25% Total Leakage Current 275 V AC at 50 Hz 8.4 OPERATING CONDITIONS AND AREA OF APPLICATION Typical: 3.0 µa Maximum: 6.0 µa Category Standards or Test Criteria EN-30 Pollution Degree IEC 61010 2 * Overvoltage Category IEC 60664-1 III Maximum Working Voltage Temperature Air Humidity Air Pressure Maximum mains voltage of the connected devices, in accordance with IEC 60601-1 Non-condensing Minimum: Maximum: 250 V AC 300 V DC +1 C +70 C Minimum: 10% Maximum: 90% Minimum: Maximum: 700 hpa 1,060 hpa Altitude Maximum: 3,200 m 8.5 ENVIRONMENTAL CONDITIONS: STORAGE AND TRANSPORTATION Category Standards or Test Criteria EN-30 Temperature Air Humidity Air Pressure Non-condensing Minimum: Maximum: -25 C +85 C Minimum: 10% Maximum: 90% Minimum: Maximum: 500 hpa 1,060 hpa * Normally only nonconductive pollution occurs. Temporary conductivity caused by condensation is to be expected. The Network Isolator can be permanently exposed to this voltage level. PD1100-V20 Page 8 of 12 2015 EMO Systems GmbH

8.6 CERTIFICATES All Network Isolators from EMO Systems GmbH are additionally registered by UL International as Recognized Components, under the file numbers E249126 and E362969. They are therefore suitable for application in American and Canadian markets. Furthermore, the compliance of our Network Isolators with the standard specifications IEC 60601-1 (3 rd Ed.), ANSI/AAMI ES60601-1 and CAN/CSA-C22.2 No. 60601-1 has been confirmed by an independent, accredited laboratory. To view a copy of these certificates, please visit the UL Online Directory or contact us directly. The certification of our products to the requirements of the IEC 60601-1-2 has also been confirmed by an external laboratory. The test report can be obtained upon request. Our Declaration of Conformity can be found on our website, which confirms the compliance of our products with the requirements of the Low Voltage Directive, the Electromagnetic Compatibility Directive, and the Restriction of Hazardous Substances Directive (RoHS). Category Standards or Test Criteria EN-30 UL Recognized Component UL File No. IEC 60601-1 Complies with the requirements of a galvanic separator in accordance with IEC 60601-1 (Ed. 3.1) E246126 E362969 IEC 60601-1-2 Complies with the requirements of IEC 60601-1-2 ANSI/AAMI ES 60601-1 CAN/CSA-C22.2 No. 60601-1 Low Voltage Directive EMC Directive RoHS Directive Lead-free Complies with the requirements of ANSI/AAMI ES60601-1 Complies with the requirements of CAN/CSA-C22.2 No. 60601-1 Complies with the requirements of the directive 2014/35/EU Complies with the requirements of the directive 2004/108/EU Complies with the requirements of the directive 2011/65/EU Contains no lead-containing substances, and is manufactured with lead-free solder PD1100-V20 Page 9 of 12 2015 EMO Systems GmbH

8.7 ISOLATION DIAGRAM B B Ethernet input Ethernet output Plastic end bezel B A B Plastic end bezel Metal enclosure Figure 4. Isolation diagram for EN-30 Area Number and type of Means of Protection Material Group (from CTI) Maximum Operating Voltage V AC V peak Required creepage distance (mm) Required clearance distance (mm) Measured creepage distance (mm) Measured clearance distance (mm) A 2 MOPP * IIIb 250 353 8.0 5.0 9.0 9.0 B 2 MOPP * IIIb 250 353 4.0 2.5 7.2 4.5 8.8 FREQUENCY RESPONSE Figure 5. Typical frequency response for Insertion Loss and Return Loss of an EMOSAFE EN-30 Network Isolator. * MOPP = Means of Patient Protection Materials in the Material Group IIIb have a Comparative Tracking Index (CTI) value between 100 and 175. PD1100-V20 Page 10 of 12 2015 EMO Systems GmbH

9 CIRCUIT DIAGRAM Figure 6. Circuit diagram for EN-30 10 PACKAGING Contents: Network Isolator. EN-30 Mounting bracket, including screws 4 self-adhesive rubber feet A packaging label provides the following information: Article description Quantity Ordering code (OC) Date of Manufacture Serial number The serial number is printed as both a 1D- (Code 128) and a 2D barcode (Data Matrix). 11 PRODUCT MARKINGS Through this mark, the conformity of the product with all applicable EU Directives is confirmed. Designates the product as a UL "Recognised Component"; File number E249126. The product may not be disposed of in domestic rubbish. This product contains no substances containing lead and is manufactured using leadfree solder. This product meets the requirements of EU Directive concerning the limitation of the use of certain hazardous substances in electric and electronic equipment. PD1100-V20 Page 11 of 12 2015 EMO Systems GmbH

12 SCHEDULED MAINTENANCE When used as directed, EMOSAFE Network Isolators are maintenance-free. 13 ENVIRONMENTAL PROTECTION INFORMATION This device contains electronic components. At the end of its service life it is to be returned to the manufacturer for disposal. 14 QUALITY EMO Systems operates a certified quality management system for development and production in accordance with ISO 9001 and ISO 13485. Prior to delivery, each Network Isolator is subjected to a comprehensive quality inspection. This inspection ensures, among other factors, that the attained values for leakage currents, dielectric withstand strengths, insertion losses, return losses, and near end crosstalk values all meet the specified requirements. 15 CONTACT AND SUPPORT Please find our up-to-date contact details on our website: Or send us an e-mail at the following address: http://www.emosystems.de/en/contact support@emosystems.de 16 LEGAL NOTIFICATION The information provided above in this datasheet has been compiled with all due care, and is believed to be accurate and reliable. However, we cannot guarantee that the information contained is completely free from error. The end user is responsible and liable for the proper use of this product; EMO Systems assume no liability. We reserve the right to make changes to this datasheet without notice. PD1100-V20 Page 12 of 12 2015 EMO Systems GmbH