XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Type Quickstart (from device Version 2)

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

PTC/PT100 board 2.0 Option

Electronic pressure switch with display Model PSD-4

Operating instructions. Standstill monitor A / / 2011

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

High Pressure E/P Regulator. ITVH Series

SUBMINIATURE MICROSWITCHES - SEALED

FP-PS-4. Features. Installation

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

Operating instructions Electronic pressure sensor PN7xxx

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Temperature Switches

XBP24-E Base 24 I/O Ethernet PRELIMINARY. General characteristics Part number

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating instructions Electronic temperature sensor TN7511

INSTALLATION INSTRUCTIONS LFH160 Cable

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Inductive sensor NI3-EG08K-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Cable distribution systems

Turbine Wheel Flow Meter/ Monitor for Liquids

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

SUN2000-(2KTL-5KTL)-L0. Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

UPort 1200/1400/1600 Quick Installation Guide

Moxa TCC-100 Series Hardware Installation Guide

DRH. Paddle Wheel Flow Sensor

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

PFK series M18 cylindrical inductive sensors

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

FL MC 2000E (SM40) LC

Display Solid-state Temperature Switch

PTC/PT100 board 2.0 Option

Test Fixtures for low PCB volumes MA xxx Change made easy

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

Resolver to Digital Expansion Board

Quick Installation Manual

Inductive sensor BI1.5-EG08-Y1-H1341

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Tina 1A Blanking plug

S82S (3/7.5-W Models)

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

VPort 06EC-2V Series Quick Installation Guide

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

CPCI-PS24 24V-Power Supply

Operating instructions Pressure sensor. PN50xx / / 2010

Logic Controller Millenium Evo

Logic Controller Millenium Evo

SS400 Series. Please refer to SS400 Series Order Guide on page 7 for details.

PTC/PT100 board 2.0 Option

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

Operating instructions. Switching amplifier DN0210 DN / / 2015

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

INJ-24A Series Quick Installation Guide

Delta Multifunction Pressure Sensor DPA Series

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

TBX-96 TERMINAL BLOCK

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Inductive sensor BI5-EM18-Y1X-H1141

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

GS202 Encoder Switch

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Installation instructions Inclination sensor EC2019 EC / / 2013

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

UPort 1200/1400/1600 Quick Installation Guide

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

SMART Position Sensor, 100 and 180 Arc Configurations

PTC 2.0 Option board. PTC/RTC Option board. Instruction Manual English. For Emotron VFX/FDU 2.0-IP2Y AC drive. For Emotron FlowDrive-IP2Y

Operating instructions Pressure sensor. PN78xx / / 2010

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Inductive sensor BI1.5-EG08-Y1-H1341

Operating instructions. Speed monitor D / / 2014

TRC-190 User s Manual

BX80 series High resolution cubic housing area sensor

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

DP DP2500 DP0250

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Features. Introduction

Transcription:

Data Sheet PSC Pressure Display and Switch Device Main Features Displayed Value Range Power Supply Electrical Connection Digital Output Output Signal Degree of Protection Operating Temperature 4.5 to 6 with 7 Selectable Value Ranges 4 VDC M Female, 4 pin Output: M Male, 4 Pin PNP or NPN, NO/NC Programmable 4 ma IP65, IP67, and IP69K C to 7 C Description Are you looking for an easy way to read and control pressure data when the conduit is hidden from view? Kavlico Pressure Sensors has the answer to your needs PSC, the simple switch with display that can be linked to a separate pressure sensor, such as Kavlico s PTE5, PE and PA delivering a clear view of accurate pressure information even if the conduit runs in a hard to access location. The Installation of the PSC display and switch device is simple. It can be mounted away from the pressure sensor, using a quickfix bracket to attach to a horizontal or vertical plane or pipe. The device can alternatively be installed directly on the pressure transmitter via the M connector. In addition, the body of the switch can be rotated by 6 for easy adjustment of the viewing angle.

Benefits Easy to mount Flexible mounting options: remotely with an electrical jumper or directly on the pressure transmitter Quick fix brackets, for vertical () or horizontal () placement, or attachment to a pipe Rotating body psi kpa MPa Easy to set up Fast and intuitive configuration of just three parameters: display range, set point, reset point Adjustment screws compatible with standard screwdrivers Easy to maintain Display status tested at each device start up and confirmed by display light up Convenient replacement without interrupting the pressure in the system Perfect fit for... PTE5 PTA5 PE PA Data Sheet PSC

Main Characteristics Output Configuration Reference PSC5 PSC5 PSC5 PSC54 PSC55 PSC56 Out Out Out Front face caption SP/FH SP RP/FL Analogue output 4... ma 4... ma 4... ma 4... ma No / Non No / Non Switching output PNP NPN PNP NPN x PNP x NPN Switching mode Hysteresis Hysteresis Window Window Hysteresis Hysteresis Out Out Connector wiring 4 4 4 4 4 Out Out I Out Out I Out I Out Out I Out Out Out 4 Power supply Current consumption Switching outputs Analogue output Operating temperature range Degree of protection Overall accuracy (analogue, digital output, display) Response time c 4 Vdc SELV or PELV(*) power supply, operating range from 7 to Vdc 5mA ma with shortcircuit Switching capacity & overload protection Voltage drop V 4... ma: load: 5 Ω (4V) Ω (7V) 5 to 7 C ( to 58 F) IP65, IP67 conforming to EN/IEC 659 IP69K conforming to DIN 45 < % of the selected display range 5 ms (*) SELV: Safety extra low voltage / PELV: Protected extra low voltage Electrical equipment should be installed, operated and maintained only by qualified personnel. No responsibility is assumed by Kavlico Pressure Sensors for any consequences arising out of the use of this material. Data Sheet PSC

Output Description Switching output Analogue output The 4mA analogue output is strictly the image of the pressure transmitter output signal Dimensions and Tightening Torques Wiring Diagram M x 8.5 mm in. Input M 4pin female connector 98% NP Two switching outputs Pressure () Fixed hysteresis SP Analogue output signal (5) Analogue output curve ma % NP Output () SP Fixed hysteresis = % of the selected display range ma 4 ma 5% % Pressure () 98% NP FH 5% NP FL Pressure () 95% NP % NP Output () NO NC Window mode The window switching mode is typically used for the "pressure regulation applications" P = FHFL u % Selected display range (4)) 98% NP SP 5% NP rp Pressure () 95% NP % NP Hysteresis mode Output () NO NC The hysteresis switching mode is typically used for the "pumping applications" P = SPrP u % Selected display range (4) Out Out B 4 I in 55.7 SP Out Out 77. 67.64 SP Caution M x 4.6 4.65 A A y Nm / 7.7 lbin B y Nm / 7.7 lbin UNINTENDED EQUIPMENT OPERATION Only connect a 4mA pressure transmitter, directly or thanks to MM 4pin electrical jumper. Make sure the pressure transmitter pin out and analogue signal is compatible with PSC if it is not a Kavlico one. Failure to follow these instructions can result injury or equipment damage. Data Sheet PSC 4

Mounting Possibility Usage Precautions Out Out SP Out Out SP Fixing bracket 4E7 (Vertical plan) or or Tmax = 8 C (76 F) or /8 y Ø y Out Out SP y m 4E7 (Horizontal pla PTE5ppp Maintenance At each power on, all the display segments are simultaneously lit up briefly. This allows the operator to check that all segments are well operating. Cleaning Out Out Out Out Out SP SP Data Sheet PSC 5

How to Order Output Output Switching mode Hysteresis Windows 4... ma PNP PSC5 PSC5 4... ma NPN PSC5 PSC54 PNP PNP PSC55 NPN NPN PSC56 Vertical surface fixing Horizontal surface fixing M Jumper cable.5m 4E7 4E7 E7 Before installation and operation, ensure that the appropriate pressure sensor has been selected in terms of pressure range, design and specific measuring conditions. Noncompliance can result in serious injury and/or damage to the equipment. Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Kavlico reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products. Data Sheet PSC 6

Sales Offices Worldwide Main Contact Americas Brazil Mexico USA Sensata Germany GmbH Potsdamer Strasse 4, 4 Minden Tel: 49 57 859 Fax: 49 57 8599 www.sensata.com Europe England France Germany Italy Netherlands Spain Sweden Russia 6 Kavlico, a brand of Sensata Technologies. All rights reserved. Kavlico s General Terms & Conditions apply and can be found on our website. Asia Pacific China India Japan South Korea Your local sales contact: Ref.: DS_PR_EN_LT_JUL 6 I CreationDesign: Kavlico Photos: Oliver Windus, Fotodesign