ACS-8-System. Access Control. Performance features at a glance

Similar documents
ACS-8-System. Access Control. Performance features at a glance

Honeywell Security Deutschland. Access Control Systems

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

VICON ACCESS CONTROL CONTROLLERS

AC5160 SiPass integrated controller kit

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

PRO3200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware

ACCESS CONTROL SYSTEM

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

HUDGE STORAGE MEMORY TO CATER FOR FUTURE EXPANSION OPTO ISOLATION FOR BETTER NOISE PROTECTION

CardaxFT Reader I/O Interface

Access Easy Control System. Reference Guide

AC5102. Features. Advanced Central Controller

Intelligent Four Lift Controller TS0869

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

TAC I/NETTM 1284, 1280, Security Control Unit

Technical Data sheet

SiPass Entro. Open the door to comprehensive security.

Access Easy Controller V 1.0

JUMO mtron T Measuring, Control, and Automation System

Lab 5: Access Control Training Station

Data sheet VIPA CPU 214PG (214-2BE03)

Key Switch. Document version: 1.5 (Updated 02 May 2017)

AC5160 Controller. Fire & Security Products. SiPass integrated

Power Panel Integrated control, operation and visualization

MaCaPS International Ltd

Data sheet CPU 115 (115-6BL02)

Pegasus Equipments Export Limited. Local Contact:

Technical Instructions MT15000/2 MT15000/2-M

Data sheet VIPA CPU 214NET PG (214-2BT13)

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

More than safety. Product Overview. Safety Engineering

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

Data sheet CPU 315SB/DPM (315-2AG12)

ACR880 GPRS Portable Smart Card Terminal

Compass RTU Guide. Version 3.x

6222 Two Door Module Technical Operations Manual

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

Web-based Access Control System. Employee access. EMBEDDED Web Browser

TMAS G 120 / G100-RF / G80 Multifunctional Access and Security Terminal

MBM - Modular I/O system IP20

SECURITON Copyright by Securiton

ATU800. Technical specification

Web-based Access Control System. Lower Cost of Ownership

eh880 Secure Smart Card Terminal

DORMA. Access Control

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

Data sheet VIPA CPU 115DP (115-6BL22)

Supply voltage. Input current. Encoder supply. Memory

BACnet. b3810 Series Local Controllers

Data sheet CPU 315SB/DPM (315-2AG12)

ACTpro 1500 Single Door IP Controller

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

Datenblatt / Specifications. ACR880 GPRS Portable Smart Card Terminal. idvation GmbH

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Andover ContinuumTM Infinet II

Accessories / 7XV5820

Control Panel CP600 CP651, CP651-WEB

Installation / Control / Monitoring Technique

ENGINEERING SPECIFICATIONS SENSAPHONE 2000

SI410 Sintony Intrusion Control Panel

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

UC-2000 Installation Manual Unicorn Computers Technology Limited

To make it really simple to manage, there is no need to install software on PCs as it has a built-in WEB server manageable via WEB.

Professional Access Control

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

FC2080 Fire control panel (modular)

Technical Datasheet. XMP-TMC28xx-xxx

General information. Display. Supply voltage

NEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

General information. Display. Supply voltage. Input current

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

Control Panel CP600 CP635, CP635-B, CP635-WEB

Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

Data sheet CC 03, Commander Compact (603-1CC21)

ACTpro Single Door IP Controller. Operating & Installation Instructions

Lux Intelligent Emergency Light Testing System. Lx Features

Control Panel CP600-eCo CP604, CP604-B

AR6181-MT, AR6182-MT Card reader

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Quick Start Installation Guide

General information. Display. Supply voltage

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

4 balanced inputs 1 relay output

SI220 Sintony Intrusion Control Panel

iloq S10 Online Configuration Guide

WaterCress Portfolio

DSC PowerSeries Neo Integration

General information. Display. Supply voltage. Input current. Encoder supply. Output current

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Installation guide for PR302 v2.0 Rev. E

Installation & User Manual

ACR89 Handheld Smart Card Reader Technical Specifications. Datenblatt / Specifications

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Transcription:

ACS-8-System Access Control The ACS-8 is an access control system which is modular in construction and highly autonomous. A particularly noteworthy performance feature is the flexible and freely-selectable installation technology. This enables conventional connection of up to two separate doors or one door with an internal and external reader. An expansion option of up to max. 8 doors exists via the communication module utilising core-conserving RS-485 bus technology. Standard features include two controllable RS-485 interface drivers integrated in the communication module. The firmware is completely upgradable. Time-consuming EPROM changing during function expansion is thus a thing of the past. New program components and expansions can be imported in the central control units via the access control software (e.g. MultiAccess for Windows or IQ MultiAccess). Up to 8 ACS-8 units can be operated via an external interface converter, up to 32 units via an external bus controller. Access control rights are set up and administered via the access control software (e.g. MultiAccess for Windows or IQ MultiAccess). The ACS-8 contains decision rights for door release and control. Terminals can be integrated directly in existing ethernet networks (LANs) through selective configuration with an ethernet card (026840.29). A maximum expansion of 999 doors per location can be achieved through the utilisation of several bus controllers and/or in the ethernet network. Performance features at a glance Intelligent access control terminal up to 4 doors (4 doors strikes, 2 readers/keypads directly connectable, 2 futher readers/keypads via RS-485 module bus, expandable up to max. 8 doors via RS-485 module bus) Upgradable program memory and dynamic memory administration Battery-buffered memory (0.5 MB, expandable up to 3.5 MB) Approx. max. 65 500 identification cards* Approx. max. 512 room/time zones* National holiday and leave calendar Booking buffer for max. 65000 events* Clock with date and automatic daylight saving time/normal time changeover BSI-listing (including all components connectable to the ACS-8) VdS approval Connection of: 2 readers with clock/data interface and 2 keypads with 2-wire interface possible 4 relay outputs (e.g.: door strike, flash lamp, etc.) 3 semiconductor outputs (e.g.: threat, watchdog, etc.) User-friendly and flexible event control via inputs and relays Macro-control (IACP control, lift control, etc.) Anti passpack, barring repeated entry, threat code, counter control Lock function with reciprocal door state influence * Values depend on the memory configuration and parameterising of dynamic memory administration.

ACS-8 planning example 2

ACS-8 planning example 3

ACS-8 planning example 4

ACS-8 planning example 5

026580 Basic ACS-8 system, 12 V DC 12 V DC 10 V DC to 15 V DC without periphery max. 150 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Sheet steel / 250 x 210 x 100 mm 026585 Basic ACS-8 system, 230 V AC (As for 12 V version) 230 V AC 230 V AC -15% +10% Continuous current consumption 1,4 A Battery space 1x 018003.10 (3,5 Ah) or 2 x 018002.10 (2,0 Ah) Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm Includes 010 690.02 power supply/charger unit Power supply unit selection depends on the connected consumers. 026575 Basic ACS-8 system with freely-selectable power supply unit integration As for 230 V version, but without power supply unit.one of the following power supply/charger units can be utilised, depending on current requirement: 012168 = 80 Ah/continuous current consumption: 3,5 A 012170 = 130 Ah/continuous current consumption: 5,0 A 12 DC 10 V DC to 15 V DC without periphery max. 150 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm Memory expansions 026596 1 MB RAM memory card 026597 2 MB RAM memory card 026598 3 MB RAM memory card Function expansion 026587 Communication module The ACS-8 communicates via the communication module with the connected RS-485 users. Standard features include 2 separated RS-485 interface drivers integrated in the communication module. A maximum of 2 communication modules can be integrated per ACS-8. A maximum of 32 users can be connected simultaneously per ACS-8. max. 150 ma Module BUS users / RS-485 modules 026590 Input module, RS-485 with potential separation Digital inputs Dimensions (W x H x D) 4 x with potential separation max. 140 ma 9 V DC to 15 V DC 118 x 118 x 30 mm 6

026591 Output module, RS-485 with potential separation Relays Dimensions (W x H x D) 4 x 24 V DC/1 A max. 250 ma 9,5 V DC to 15 V DC 118 x 118 x 30 mm 026592 Input/Output module, RS-485 with potential separation Differential inputs Digital inputs Relays Dimensions (W x H x D) 2 x erasable 2 x with potential separation 2 x 24 V DC /2 A max. 230 ma 9,5 V DC to 15 V DC 118 x 118 x 30 mm 026595 Potential separation module, RS-485 A maximum of 4 modules without an intrinsic RS 485 bus with potential separation can be connected to the module. Recommended when using external power supply units. Connectable modules are: 027555 and all readers and keypads with RS 485 and control lead. max. 140 ma 10V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm 026593 Door module, 12 V DC, RS-485 with potential separation The complete door periphery is wired to the door module. The door module is a module bus user and communicates with the ACS-8 via an integrated RS 485 interface. The ACS-8 contains the access control rights and makes decisions. The number of doors to control by a door module depends on the access control software used. MultiAccess for Windows: 1 door; IQ MultiAccess: 2 doors. The following components can be connected simultaneously to the door module: - two clock/data readers - a monitoring contact - two 2-wire keypads - a tamper switch - an opening contact - a door relay - ta bolt switching contact - an alarm relay - a glass breakage contact with reset - a tamper relay - a door release push-button (If 2 doors are controlled by a door module, the number of inputs and outputs left for individual use reduces as they are required as monitoring contact, door strike relay and door strike key for the second door.) 12 V DC 10 V to 15 V DC in no-load operation without ext. user 200 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Plastic / 250 x 210 x 100 mm Power supply unit with battery charging circuit 026594 Door module, 230 V AC, RS-485 with potential separation As for 12 V version, but with 230 V power supply unit. 230 V AC 230 V AC -15% to +10% in no-load operation without ext. user 65 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Battery space 1 x 018002.10 (2,0 Ah) Housing / Dimensions (W x H x D) Plastic / Plastic250 x 210 x 100 mm 7

Additional performance features 4 digital inputs (e.g.: door strike push-button, monitoring contact, etc.) 8 differential detector groups (e.g.: magnetic contact, glass breakage sensor, etc.) Integrated tamper contact Optional host interfaces (RS-485, RS-232, 10/100 Mbit/s fast ethernet, Current Loop) Variable door release, monitoring and alarm times Automatic function control via time zones (e.g.: door release, etc.) Special relay function for real-time release for rescue route integration RS-485 module bus (optional) Flexible power supply unit configuration, depending on power requirement 12 V DC emergency power supply, depending on power supply unit configuration and power requirement VdS-approval Z 105009, class C Support of analog modems and ISDN terminal adapters Direct modem connection without additional card The following components can be connected to the communication module RS-485 magnetic card reader RS-485 Legic reader RS-485 mifare reader RS-485 Esser reader contactless RS-485 keypad RS-485 Fingerkey RS-485 12 V version/230 V version door module RS-485 input module RS-485 output module RS-485 input/output module Biometrics: Fingerkey and/or integration of biometrical systems via RS-485 module bus Arming/disarming of an intrusion detection system via AC-readers to be realized using inputs/outputs and macro programming in IQ MultiAccess Accessories 026692 RS-485 interface (5-wire) without potential separation 026693 RS-485 interface (5-wire) with potential separation 026840.03 Asynchronous RS-232 host interface 026840.16 Current Loop interface Order data 026840.29 10/100 MBit/s ethernet host interface 018002.10 Rechargeable battery 12 V DC / 2.0 Ah 018003.10 Rechargeable battery 12 V DC / 3.5 Ah 012168 Power supply/charging unit 80 Ah/permanent current drain: 3,5 A 012170 Power supply/charging unit 130 Ah/permanent current drain: 5,0 A Item no. Description Item no. Description Central control unit versions 026580 Basic ACS-8 system, 12 V DC approval Z 105009, class C 026585 Basic ACS-8 system, 230 V AC (includes 010690.02 power supply/charger unit) approval Z 105009, class C 026575 Basic ACS-8 system with freely-selectable power supply unit integration (power supply unit selection depends on the connected consumers, VdS only with power supply units approved by VdS) approval Z 105009, class C 026587 Communication module (required for controlling more than 2 doors) Module bus users / RS-485 modules 026590 Input module, RS-485 with potential separation 026591 Output module, RS-485 with potential separation 026592 Input/Output module, RS-485 with potential separation 026595 Potential seperation module, RS-485 026593 Door module, 12, V DC, RS-485 with potential separation 026594 Door module, 230 V AC, RS-485 with potential separation Honeywell Security Group Novar GmbH Joh.-Mauthe-Str. 14 D-72458 Albstadt Phone +49 (0) 74 31/801-0 Fax 801-12 20 www.honeywell.com/security/de info.security.de@honeywell.com P32501-22-0G0-04 04. 2010 Subject to change without notice. 2010 Honeywell International Inc.