IT8000 INDICATOR Stainless Steel washdown enclosure IP65. LCD Display with Back Lighting. 32-button alphanumeric keyboard. Power Supply 110-240 VAC or 12-30 VDC. Stainless Steel universal mounting stand (Desk-top version). Free Programmability possible with the RTG WIN. Connection of scales with analog or digital loadcells. Connects to one or two scales with up to 16 Digital loadcells (Without additional power supply). Specific software modules support the connection of PCs, PLCs, scanners transponder systems, printers, frequency inverters and wireless communications. Calibration is possible as single or multi-range and as single or multi-interval scale. Entry and recording of IDs is possible in all programs. Construction Compact stainless steel IP65 housing desk-top, wall-mount, column-mount and panel mount version; cable connections with sealed cable glands. Display LCD Dual-line display with back lighting. Up to 4 x 20 alphanumeric characters, height of characters 19mm. Keyboard Sealed flat membrane keyboard with tactile feedback. Numeric keys and input of alpha characters. Optional connection of PC Keyboard. Electrical Connection 110(-15%) to 240 (+10%)VAC, 50/60H via integrated power supply, Option: 12-30VDC Power consumption max. 20V. Operating Temperature -10 C to + 40 C, 95% relative humidity, non condensing. TECHNICAL DATA Weighing Electronics For the connections of 1 or 2 scale platforms with a max. of 16 analog loadcells. W&M approved resolution of up to 6000d with max. 80% preload, internal resolution 524,000d, 50 updates per second, input signal 0.33µV/e. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection. Serial Interfaces Up to 4 interfaces, selectable RS232, 20mA CL, RS422 or RS485, for printer, host communication, precision scales and other peripheral devices, protocols for PC, printer and remote display configurable. Ethernet connection via internal Ethernet interface as an option. Fieldbus interfaces Fielbus Interface Profibus DP alternatively Interbus, DeviceNet or Modbus (RTU). Parallel I/Os 4 internal optoisolated inputs and Outputs, 24VDC, or external relay / transistor module (64 inputs, 64 outputs max.) Internal analog output (15 bit; resolution 32,768 steps) or external module for 4 analog inputs/ outputs (12 bit; 4,096 steps). Options W&M approved data archive on PC, storage of weighing data on the PC s hard disk, long term archiving possible over several years. Backup & Restore Software to backup data on PC. PC COM+ ActiveX component for PC connection. Splash and Dust Cover Transparent plastic cover to protect display and keyboard. CONSTRUCTION Suitable for desk-top or wall-mount installation. Dimensions WxHxD: 225x190x145mm Panel-mount installation Dimensions WxHxD: 260x215x70mm Cut-out in panel: 243x198mm 76 2010, Inc. Specifications subject to change without notice
IT TRUCK TECHNICAL DATA IT TRUCK/ONLINE program and documentation Truck scale terminal software, NTEP approved, with on-line and off-line operation. Program loaded in IT8000, incl. Operating manual and Installation. See also data and application sheets IT TRUCK/ ONLINE. IT BAG IT BAG program and documentation Bag Filling Controller Software.. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BAG. IT BASIC IT BASIC program and documentation NTEP approved weighing and data capture system for goods-in, production and shipping. See also data and application sheets IT BASIC. IT CHECK IT BULK IT BIGBAG IT BATCH IT BATCH program and documentation Batching controller software, for automatic recipe-controlled batching processes. Min. hardware requirements: 16 I/Os (eg RS485 relay module) or fieldbus (eg Profibus DP), supported options: serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BATCH. IT BIGBAG program and documentation BigBag Filling Controller Software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: further I/Os for additional functions, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BIGBAG. IT BULK program and documentation Bulkweighing controller software, for shipping and/or receiving of bulk material. Min. hardware requirements: 8 I/Os (eg RS485 relay module) or Profibus DP. Supported options: additional 8 outputs for silo control, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BULK. IT CHECK program and documentation Checkweigher controller software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: 4 more I/Os for additional functions, serial host interface (SIM), serial printer interface (SIM), second scale interface. See also data and application sheets IT CHECK. 2010, Inc. Specifications subject to change without notice 77
IT COUNT TECHNICAL DATA IT COUNT program and documentation Parts counting terminal software, for goods-in, production and shipping. See also data and application sheets IT COUNT. IT FILL IT FILL program and documentation Liquid filling controller software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: additional I/Os, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT FILL. IT FLOW CONTROL IT FLOW CONTROL program and documentation Software for loss-in-weight feeder controller, for the continuous discharging of liquids or bulk material at constant rate. Min. hardware requirements: 8 I/Os (eg RS485 relay module) or Profibus DP, control of frequency inverter via SIM RS485 or MAI/DAE interface; supported options: serial host interface (SIM), serial printer interface (SIM), analog output for flow rate, analog input for target value. See also data and application sheets IT FLOW CONTROL. IT ONLINE IT ONLINE program and documentation Software for remotely controlled weighing terminal, for weight and data capture applications, data archive (min. 80,000 records). Min. hardware requirements: 1 x SIM or Ethernet interface. See also data and application sheets IT ONLINE. PC IT ONLINE OP IT ONLINE OP program and documentation Software for remotely controlled fieldbus weighing terminal, for capturing weights and production data, with Operator Panel function. For use as slave participant in fieldbus systems Profibus DP, Modbus (RTU), DeviceNet, DIN66019 or point-to-point connections DUST3964R or RK512. Min. hardware requirements: fieldbus interface (eg Profibus DP). See also data and application sheets IT ONLINE OP. PC IT COUNT IT SQC program and documentation Software for statistical quality checks of prepackaged goods. See also data and application sheets IT SQC. Sample Custom Programming Custom programming Customized programming designed specifically for your application. 78 2010, Inc. Specifications subject to change without notice
OPTIONS IT8000 desk/wall version, 110-240VAC, 50-60Hz IT8000 desk/wall version, 12-30VDC IT8000 panel-mount version, 110-240VAC, 50-60Hz IT8000 panel-mount version, 12-30VDC OPTIONS IT8000 scale interface, ADM to connect 1 scale with analog loadcells, screw terminals for loadcell cable. Two ADM modules can be installed in an IT8000 terminal, providing connection for a max. of 1x16 or 2x8 loadcells (350 Ohm each), 2x4 loadcells are possible via zener barriers. IT8000 scale interface, IDN to connect 1 Mettler-Toledo platform with PikBrick loadcell, screw terminals for loadcells cable, (1 IDN module max. can be installed in an IT8000 terminal, in addition 1 ADM module possible). Scale adapter cable Mettler-Toledo with round female connector to connect to Mettler-Toledo scale with PikBrick transducer, delivered individually with connecting diagram. IT8000 scale connection, DWM-Sartorius to connect 1 digital Sartorius IS scale, srew terminals for loadcell, (1 DWM module max. can be installed in an IT8000 terminal 1 ADM module possible). Scale adapter cable Sartorius with round female connector to connect to Sartorius-IS scale, delivered individually with connecting diagram. IT8000 scale connection, DWM-HBM to connect up to 6 digital HBM loadcells C16i (8 max. with external power supply unit), screw terminals for loadcell cable, (1 DWM module max. can be installed in an IT8000 terminal, in addition 1 ADC module possible). IT8000 scale connection, DWM-Revere to connect up to 4 digital SCC i SBC REVERE loadcell (16 max. with external power supply unit, DSC only with external power supply), screw terminals for loadcell cable, ( 1 DWM module max. can be installed in an IT8000 terminal, in addition 1 ADM module possible). External Power Supply for Digital Load Cells for connection of up to 16 digital REVERE SLC or HBM C16i loadcells to IT8000, 15VDC/1.7 A, Input 110-240VAC, aluminum die cast housing, IP65, LxWxH: 200x100x80 mm, line cord with safety plug). Serial interface module, SIM RS232 to connect printer, remote display, PC and other peripheral devices. Serial interface module, SIM 20mA CL to connect printer, remote display and other peripheral devices, transmitter and receiver passive. Serial interface module, SIM RS485.4 4-wire connection, common potential, for multidrop networks, frequency inverters and other peripheral devices. Serial interface module, SIM RS485.2 2- wire connection, common potential, to connect RS485 relay/transistor modules, MAI modules with analog I/Os or ADCBox (3-8 scale interface). 2010, Inc. Specifications subject to change without notice 79
OPTIONS I/O module, PIM with 2 digital inputs (24VDC) and 2 digital outputs (24VDC, 100mA), optoisolated, PIMs are installed in rising order in socket PIM1 to PIM2, (in combination with analog output, the DAU module is installed in socket PIM2). DAU15, analog output module 0-20mA / 0-10VDC delivered individually for installation in PIM socket, output 0-20mA, 2-20mA, 0-10VDC or 2-10VDC selectable, optoisolated, active. (15 Bit resolution, 32.768 steps), adjustable, limits of temperature error ± 0,002%/K. Output of gross or net weight, selectable. Analog output module, DAU 0-20mA, 0-20mA (resolution 256 steps) or 4-20mA (resolution 204 steps) programmable, common potential, limits of operating error ± 4%. The analog output must be supported by the application program! Analog output module, DAU 0-10VDC, resolution 256 steps (8 bit), common potential, external power supply 15-30VDC required, limits of operating error ± 4%. The analog output must be supported by the application program! IT8000 PC keyboard connection, MFII to connect full-size PC keyboard with MFII connector to IT8000, short adapter cable with 5-pin female DIN connector (IP65), cable connected through cable gland. IT8000 PC keyboard connection, PS/2 to connect full-size PC keyboard with PS/2 connector to IT8000, short adapter cable with female PS/2 connector (IP65), cable connected through cable gland. IT8000 Profibus DP controller, PCM to connect to fieldbus Profibus DP, slave operation, address selectable, incl. GSD file for SIEMENS S5 and S7 to configure the Profibus DP master. IT8000 fieldbus-/sim4 module, FBM can either be used with DeviceNet module or without module to provide socket for 4. serial interface (please order SIM RS232, SIM 20mA CL or SIM RS485 separately). IT8000 Ethernet module, ECM internal Ethernet interface with RJ45 connector. Optional without cable or with 5m or 10m Ethernet cable (with counter nut of cable gland for simplified installation). IT8000 remote operating unit desk-top or wall-mount installation, protected to IP65, RS485 interface to connect to IT8000 main unit, no connecting cables, 110-240VAC, line cord 2.5m included. Dim. including mounting brackets WxHxD: 260x210x170mm. PARTS IT8000 main board CPU8000, 110-240VAC 1 MB CPU with sockets for 2 ADM modules, sockets SIM1 - SIM3 for serial interfaces, PIM1 - PIM2 for I/O or analog modules and ECM (Ethernet) or FBM for fieldbus modules or SIM4, power supply 110-240VAC. IT8000 main board CPU8000, 12-30VAC 1 MB CPU with sockets for 2 ADM modules, sockets SIM1 - SIM3 for serial interfaces, PIM1 - PIM2 for I/O or analog modules and ECM (Ethernet) or FBM for fieldbus modules or SIM4, power supply 12-30VDC. Display module for IT8000, 4x20 characters for use with CPU8000 Index 006 or higher, operating system RTP 6.6 or higher. 80 2010, Inc. Specifications subject to change without notice
Protection Filter Pane for Display IT8000 3 Volt Lithium battery 1/2 AA to replace battery on CPU8000, set of 3 pcs. PARTS Ribbon cable for IT8000 to connect CPU8000 and Display. IT8000 SysTec standard membrane keyboard, delivered individually, for service purposes to replace damaged overlay. IT8000 lid wall/desk housing with SysTec standard membrane keyboard, including gasket, filter pane nor included. Transparent dust cover for IT8000 protects the IT8000 keyboard overlay against dirt and dust, suitable for use in the chemical industry and in wet environment, PVC foil, transparent, 0.15mm thick. Other options and parts available upon request. 2010, Inc. Specifications subject to change without notice 81