TECHNICAL DATA. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection.

Similar documents
14 SYSTEC Price List February 2018

ABB MEASUREMENT & ANALYTICS DATA SHEET. IT1 Universal weighing terminal

FAX

STANDARD TERMINAL. Digital Indicators. Product Number 3020

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

C500 Series Data Sheet

Maxxis 5 Process Controller with BASIC Application

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

Maxxis 4 Process Controller with BASIC Application

Signum Complete Scales Supreme Stainless Steel SIWSBBS and SIWSDCS

Signum Complete Scale Advanced SIWABBP SIWADCP SIWAEDG

Presented By. NicolScales.com Contact Us

APS SCALE SERIES DIMENSIONS

Weighing Indicator. Features. Description. Applications

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

TLB4 TLM8. ERDE-Elektronik AB - Spikgatan Vellinge TLM8den.

Weight controller Maxxis 5

Signum Complete Scales High-resolution Models - SIWA SIWS Series

Signum Complete Scales High-resolution Models - SIWA SIWS Series

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Signum Complete Scales High-resolution Models SIWA SIWS Series

Structure and Function

Continuous level measuring system NB 3000 Selection list

M260 Load Cell Amplifiers

Connect AS-I Gateways to PC for Configuration and Troubleshooting

INTECONT Tersus Mass flow rate measurement

Maxxis 5 Process Controller with PHASE Application

Checkweighers IP69K GMP EHEDG NSF. for unmistakable results

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Dupline Fieldbus Components

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Maxxis 5 Process Controller with IBC Application

Data sheet CC 03, Commander Compact (603-1CC21)

R310 & N310 R320 & N320 Digital Indicator

Model BBA429 BBA439check BBA449check+ IND429 IND439check IND449check+ Type of construction Compact balance Weighing terminal Basic functions

Power and Performance for Weighing Applications

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

2 Made in Italy Electronic Instruments for weighing and batching LAUMAS produces Weight Indicators and Transmitters for PC/PLC connection to the most

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

250 Series Digital Weight Indicators Legal-for-Trade CC Class III/IIIL 10,000 Divisions

DISOMAT T Weigh Transmitter

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

UniOP epad30, epad32. Tech-note PN# tn171-3.doc - 03/10/ Ver Highlights

NEW BenchPro Series Multi-Purpose Digital Bench Scale

Microcontroller Based 8 CHANNEL Temperature/Process DATA LOGGER (Product Code 8.7 to 8.9)

Operating and Monitoring Systems

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

TALON Network Manager- 2 & 6 Express

PUE C/31 measuring indicators PUE C/31H measuring indicators PUE C/31H/EX measuring indicators PUE C/41H measuring indicator...

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

KS 3012 PMA GENERAL DESCRIPTION

Note: the wiring of the dead-man buttons has been changed since October 2001.

Industrial scales Combics

APS2200CW SCALE SERIES DIMENSIONS

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

ZM400 SERIES 400 SERIES. Indicators for advanced weighing routines

Flow Measurement SITRANS F C

Maxxis 5 Process Controller with TRUCK Application

Blackbox Controllers:

LAUREL ELECTRONICS, INC.

Sartorius Combics Four indicators one ideal level of convenience

INTECONT PLUS for Measuring Systems

UniOP epad03 and epad04

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Combics Complete Scales High Resolution CAH...

Display & Open Frame Display ADP & OPD Product Line

Product Description. Contents. Fusion Series. New Information December 2003

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

DMT345 and DMT346 Dewpoint Transmitters

Data sheet CPU 315SN/PN ECO (315-4PN33)

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Data logger systems from ROTRONIC

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

UniOP CP01R-04, CP05R-04 and CP01F-02

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SB/DPM (315-2AG12)

Product data sheet accessories control and regulation Accessories AIRWIN

Data sheet CPU 315SN/NET (315-4NE12)

Automated Precision Weighing

CAEL-DP Series Dew Point Transmitter for Industrial Control

PAS 300, PROFIBUS Slave Interface Module

Continuous level measurement Ultrasonic controllers

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

60 Series. Weight-Based Indicators & Controllers

Product type designation. Control elements. Installation type/mounting

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

250 Series Digital Weight Indicators Legal-for-Trade CC Class III/IIIL 10,000 Divisions

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Transcription:

IT8000 INDICATOR Stainless Steel washdown enclosure IP65. LCD Display with Back Lighting. 32-button alphanumeric keyboard. Power Supply 110-240 VAC or 12-30 VDC. Stainless Steel universal mounting stand (Desk-top version). Free Programmability possible with the RTG WIN. Connection of scales with analog or digital loadcells. Connects to one or two scales with up to 16 Digital loadcells (Without additional power supply). Specific software modules support the connection of PCs, PLCs, scanners transponder systems, printers, frequency inverters and wireless communications. Calibration is possible as single or multi-range and as single or multi-interval scale. Entry and recording of IDs is possible in all programs. Construction Compact stainless steel IP65 housing desk-top, wall-mount, column-mount and panel mount version; cable connections with sealed cable glands. Display LCD Dual-line display with back lighting. Up to 4 x 20 alphanumeric characters, height of characters 19mm. Keyboard Sealed flat membrane keyboard with tactile feedback. Numeric keys and input of alpha characters. Optional connection of PC Keyboard. Electrical Connection 110(-15%) to 240 (+10%)VAC, 50/60H via integrated power supply, Option: 12-30VDC Power consumption max. 20V. Operating Temperature -10 C to + 40 C, 95% relative humidity, non condensing. TECHNICAL DATA Weighing Electronics For the connections of 1 or 2 scale platforms with a max. of 16 analog loadcells. W&M approved resolution of up to 6000d with max. 80% preload, internal resolution 524,000d, 50 updates per second, input signal 0.33µV/e. Option: Connection of scale platforms with digital force transducers. Option: up to 6 external scale connection. Serial Interfaces Up to 4 interfaces, selectable RS232, 20mA CL, RS422 or RS485, for printer, host communication, precision scales and other peripheral devices, protocols for PC, printer and remote display configurable. Ethernet connection via internal Ethernet interface as an option. Fieldbus interfaces Fielbus Interface Profibus DP alternatively Interbus, DeviceNet or Modbus (RTU). Parallel I/Os 4 internal optoisolated inputs and Outputs, 24VDC, or external relay / transistor module (64 inputs, 64 outputs max.) Internal analog output (15 bit; resolution 32,768 steps) or external module for 4 analog inputs/ outputs (12 bit; 4,096 steps). Options W&M approved data archive on PC, storage of weighing data on the PC s hard disk, long term archiving possible over several years. Backup & Restore Software to backup data on PC. PC COM+ ActiveX component for PC connection. Splash and Dust Cover Transparent plastic cover to protect display and keyboard. CONSTRUCTION Suitable for desk-top or wall-mount installation. Dimensions WxHxD: 225x190x145mm Panel-mount installation Dimensions WxHxD: 260x215x70mm Cut-out in panel: 243x198mm 76 2010, Inc. Specifications subject to change without notice

IT TRUCK TECHNICAL DATA IT TRUCK/ONLINE program and documentation Truck scale terminal software, NTEP approved, with on-line and off-line operation. Program loaded in IT8000, incl. Operating manual and Installation. See also data and application sheets IT TRUCK/ ONLINE. IT BAG IT BAG program and documentation Bag Filling Controller Software.. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BAG. IT BASIC IT BASIC program and documentation NTEP approved weighing and data capture system for goods-in, production and shipping. See also data and application sheets IT BASIC. IT CHECK IT BULK IT BIGBAG IT BATCH IT BATCH program and documentation Batching controller software, for automatic recipe-controlled batching processes. Min. hardware requirements: 16 I/Os (eg RS485 relay module) or fieldbus (eg Profibus DP), supported options: serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BATCH. IT BIGBAG program and documentation BigBag Filling Controller Software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: further I/Os for additional functions, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BIGBAG. IT BULK program and documentation Bulkweighing controller software, for shipping and/or receiving of bulk material. Min. hardware requirements: 8 I/Os (eg RS485 relay module) or Profibus DP. Supported options: additional 8 outputs for silo control, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT BULK. IT CHECK program and documentation Checkweigher controller software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: 4 more I/Os for additional functions, serial host interface (SIM), serial printer interface (SIM), second scale interface. See also data and application sheets IT CHECK. 2010, Inc. Specifications subject to change without notice 77

IT COUNT TECHNICAL DATA IT COUNT program and documentation Parts counting terminal software, for goods-in, production and shipping. See also data and application sheets IT COUNT. IT FILL IT FILL program and documentation Liquid filling controller software. Min. hardware requirements: 4 I/Os (eg 2xPIM) or Profibus DP, supported options: additional I/Os, serial host interface (SIM), serial printer interface (SIM). See also data and application sheets IT FILL. IT FLOW CONTROL IT FLOW CONTROL program and documentation Software for loss-in-weight feeder controller, for the continuous discharging of liquids or bulk material at constant rate. Min. hardware requirements: 8 I/Os (eg RS485 relay module) or Profibus DP, control of frequency inverter via SIM RS485 or MAI/DAE interface; supported options: serial host interface (SIM), serial printer interface (SIM), analog output for flow rate, analog input for target value. See also data and application sheets IT FLOW CONTROL. IT ONLINE IT ONLINE program and documentation Software for remotely controlled weighing terminal, for weight and data capture applications, data archive (min. 80,000 records). Min. hardware requirements: 1 x SIM or Ethernet interface. See also data and application sheets IT ONLINE. PC IT ONLINE OP IT ONLINE OP program and documentation Software for remotely controlled fieldbus weighing terminal, for capturing weights and production data, with Operator Panel function. For use as slave participant in fieldbus systems Profibus DP, Modbus (RTU), DeviceNet, DIN66019 or point-to-point connections DUST3964R or RK512. Min. hardware requirements: fieldbus interface (eg Profibus DP). See also data and application sheets IT ONLINE OP. PC IT COUNT IT SQC program and documentation Software for statistical quality checks of prepackaged goods. See also data and application sheets IT SQC. Sample Custom Programming Custom programming Customized programming designed specifically for your application. 78 2010, Inc. Specifications subject to change without notice

OPTIONS IT8000 desk/wall version, 110-240VAC, 50-60Hz IT8000 desk/wall version, 12-30VDC IT8000 panel-mount version, 110-240VAC, 50-60Hz IT8000 panel-mount version, 12-30VDC OPTIONS IT8000 scale interface, ADM to connect 1 scale with analog loadcells, screw terminals for loadcell cable. Two ADM modules can be installed in an IT8000 terminal, providing connection for a max. of 1x16 or 2x8 loadcells (350 Ohm each), 2x4 loadcells are possible via zener barriers. IT8000 scale interface, IDN to connect 1 Mettler-Toledo platform with PikBrick loadcell, screw terminals for loadcells cable, (1 IDN module max. can be installed in an IT8000 terminal, in addition 1 ADM module possible). Scale adapter cable Mettler-Toledo with round female connector to connect to Mettler-Toledo scale with PikBrick transducer, delivered individually with connecting diagram. IT8000 scale connection, DWM-Sartorius to connect 1 digital Sartorius IS scale, srew terminals for loadcell, (1 DWM module max. can be installed in an IT8000 terminal 1 ADM module possible). Scale adapter cable Sartorius with round female connector to connect to Sartorius-IS scale, delivered individually with connecting diagram. IT8000 scale connection, DWM-HBM to connect up to 6 digital HBM loadcells C16i (8 max. with external power supply unit), screw terminals for loadcell cable, (1 DWM module max. can be installed in an IT8000 terminal, in addition 1 ADC module possible). IT8000 scale connection, DWM-Revere to connect up to 4 digital SCC i SBC REVERE loadcell (16 max. with external power supply unit, DSC only with external power supply), screw terminals for loadcell cable, ( 1 DWM module max. can be installed in an IT8000 terminal, in addition 1 ADM module possible). External Power Supply for Digital Load Cells for connection of up to 16 digital REVERE SLC or HBM C16i loadcells to IT8000, 15VDC/1.7 A, Input 110-240VAC, aluminum die cast housing, IP65, LxWxH: 200x100x80 mm, line cord with safety plug). Serial interface module, SIM RS232 to connect printer, remote display, PC and other peripheral devices. Serial interface module, SIM 20mA CL to connect printer, remote display and other peripheral devices, transmitter and receiver passive. Serial interface module, SIM RS485.4 4-wire connection, common potential, for multidrop networks, frequency inverters and other peripheral devices. Serial interface module, SIM RS485.2 2- wire connection, common potential, to connect RS485 relay/transistor modules, MAI modules with analog I/Os or ADCBox (3-8 scale interface). 2010, Inc. Specifications subject to change without notice 79

OPTIONS I/O module, PIM with 2 digital inputs (24VDC) and 2 digital outputs (24VDC, 100mA), optoisolated, PIMs are installed in rising order in socket PIM1 to PIM2, (in combination with analog output, the DAU module is installed in socket PIM2). DAU15, analog output module 0-20mA / 0-10VDC delivered individually for installation in PIM socket, output 0-20mA, 2-20mA, 0-10VDC or 2-10VDC selectable, optoisolated, active. (15 Bit resolution, 32.768 steps), adjustable, limits of temperature error ± 0,002%/K. Output of gross or net weight, selectable. Analog output module, DAU 0-20mA, 0-20mA (resolution 256 steps) or 4-20mA (resolution 204 steps) programmable, common potential, limits of operating error ± 4%. The analog output must be supported by the application program! Analog output module, DAU 0-10VDC, resolution 256 steps (8 bit), common potential, external power supply 15-30VDC required, limits of operating error ± 4%. The analog output must be supported by the application program! IT8000 PC keyboard connection, MFII to connect full-size PC keyboard with MFII connector to IT8000, short adapter cable with 5-pin female DIN connector (IP65), cable connected through cable gland. IT8000 PC keyboard connection, PS/2 to connect full-size PC keyboard with PS/2 connector to IT8000, short adapter cable with female PS/2 connector (IP65), cable connected through cable gland. IT8000 Profibus DP controller, PCM to connect to fieldbus Profibus DP, slave operation, address selectable, incl. GSD file for SIEMENS S5 and S7 to configure the Profibus DP master. IT8000 fieldbus-/sim4 module, FBM can either be used with DeviceNet module or without module to provide socket for 4. serial interface (please order SIM RS232, SIM 20mA CL or SIM RS485 separately). IT8000 Ethernet module, ECM internal Ethernet interface with RJ45 connector. Optional without cable or with 5m or 10m Ethernet cable (with counter nut of cable gland for simplified installation). IT8000 remote operating unit desk-top or wall-mount installation, protected to IP65, RS485 interface to connect to IT8000 main unit, no connecting cables, 110-240VAC, line cord 2.5m included. Dim. including mounting brackets WxHxD: 260x210x170mm. PARTS IT8000 main board CPU8000, 110-240VAC 1 MB CPU with sockets for 2 ADM modules, sockets SIM1 - SIM3 for serial interfaces, PIM1 - PIM2 for I/O or analog modules and ECM (Ethernet) or FBM for fieldbus modules or SIM4, power supply 110-240VAC. IT8000 main board CPU8000, 12-30VAC 1 MB CPU with sockets for 2 ADM modules, sockets SIM1 - SIM3 for serial interfaces, PIM1 - PIM2 for I/O or analog modules and ECM (Ethernet) or FBM for fieldbus modules or SIM4, power supply 12-30VDC. Display module for IT8000, 4x20 characters for use with CPU8000 Index 006 or higher, operating system RTP 6.6 or higher. 80 2010, Inc. Specifications subject to change without notice

Protection Filter Pane for Display IT8000 3 Volt Lithium battery 1/2 AA to replace battery on CPU8000, set of 3 pcs. PARTS Ribbon cable for IT8000 to connect CPU8000 and Display. IT8000 SysTec standard membrane keyboard, delivered individually, for service purposes to replace damaged overlay. IT8000 lid wall/desk housing with SysTec standard membrane keyboard, including gasket, filter pane nor included. Transparent dust cover for IT8000 protects the IT8000 keyboard overlay against dirt and dust, suitable for use in the chemical industry and in wet environment, PVC foil, transparent, 0.15mm thick. Other options and parts available upon request. 2010, Inc. Specifications subject to change without notice 81