VARIOspeed Quick Start Manual

Similar documents
F800 SERIES Inverters POCKET REFERENCE GUIDE. us.mitsubishielectric.com/fa/en

Mitsubishi D700-SC Frequency Inverter. Easy Start Guide. The Mitsubishi D700-SC Frequency Inverter range is available to order from inverterdrive.

PLC FUNCTION PROGRAMMING MANUAL

4. Setting parameters

VLT 2800 DRIVE SPECIFICATIONS

Baltimore Aircoil Company

WARNING UNINTENDED EQUIPMENT OPERATION

Q9 ASD LOW VOLTAGE DRIVE

18805 Adams Ct., #110 ~ Morgan Hill, CA 95037, USA ~ ~ ~

INVERTER INSTRUCTION MANUAL. Relay output function. Plug-in option FR-A7AR PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING RELAY OUTPUT

EQ5 SERIES Quick Start Guide for Constant Torque Applications

P9 ASD Simple Start Guide

ADJUSTABLE SPEED DRIVES. Q9 Series

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

QUICK REFERENCE GUIDE

iqpump1000 AC Drive Multiplex Quick Start Procedure

Inverter (VFD) Manual

Quick Start Guide For GVX9000 AF Drives

TR200 DRIVE STANDARD FEATURES

Installation, Operation and Maintenance Manual

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

TR150 DRIVE STANDARD FEATURES

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

FTA3100 Series Setup and Operating Instructions

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

Quick Start Guide RSi S Series VFD. Using the 7-segment (4 digit LED) Keypad/Display

1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE

FR-A770 Ratings 690V Class. Mitsubishi Electric Automation INVERTERS 1

PROGRAMMING MANUAL IM262R00. AQUAVAR Intelligent Pump Controller START-UP GENIE PROGRAMMING MANUAL

Weight (lbs) Frame Size

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

F510 Fan & Pump AC Drive

INGERSOLL RAND Fixed Speed/Variable Speed Conversion COMMISSIONING AND OPERATION MANUAL

INVERTER INSTRUCTION MANUAL. Analog output function Digital output function. Plug-in option FR-A7AY PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

Easy To Use OEMS Take Note

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

VECTOR INVERTER -INSTRUCTION MANUAL- HIGH RESOLUTION ANALOG INPUT / EXTRA CONTACT INPUT / THERMISTOR INTERFACE FR-V5AX

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06


CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Bosch Rexroth EFC3610 Frequency Inverter. Easy Start Guide L1 L2 L3 (+) B U V W

Table of Contents 1. Overview Installation...6

SECTION VARIABLE FREQUENCY DRIVES

VFA7/VFP7 Parameter List (Ver315)

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

IPS INTELLIGENT PUMP STARTER

Pulsafeeder Technical Bulletin

Optidrive Applications Support Library

Taco System Logic (TSL)

SSW06. Soft Starters.

Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q

SED2 Variable Frequency Drives

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor INSTRUCTION MANUAL DOCUMENT NO Rev. 1.

Macro Guide. Affinity. Model sizes 1 to 6. Building Automation HVAC/R drive. Part Number: Issue: 1.

SV9000 AF DRIVES SVReady User Manual. Pump and Fan Control Application

vacon nx ac drives brake chopper unit (bcu) application user s manual

Optidrive Applications Support Library

AP Series Variable Frequency Drives Operation & Installation Manual

MD2 Variable Speed Drive Controllers

A drive dedicated to variable speed control for HVAC applications

LS M100 Frequency Inverter Easy Start Guide

Submittal Data Information SmartDRIVE SP Variable Speed Drives

Instruction Manual. P3S2INST-01A February 2008 Part Number: R1 Copyright 2008 Electromotive Systems

Radio Drive Serial Interface (RDSI) Technical Specifications

MD2 Variable Speed Drive Controllers

E7B Drive / Bypass System with TouchPad Control Panel (option T or Y) Control Wiring and Start-up Procedure

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Altivar 21 Programming and Operation Guide

YASKAWA AC Drive V1000 Supplementary Documentation for Software Upgrade. Preface

Variable Speed Drives

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

PowerFlex 400 AC Drive Guide Specification

IP55 INVERTER FR-A800. Compatible FACTORY AUTOMATION. IP55 Compatible FR-A806. Direct installation near the machine

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Pump Quickstart Guide

ADJUSTABLE SPEED DRIVES. GX7 Series

SB200. VSV V/F Control Inverter. High-performance. Applications General pump & fan control HVAC Industrial motor control

Submittal Data Information SmartDRIVE VP Variable Speed Drives

Operator Interface Terminal Manual Standard Two or Three Pump VFD Booster

Section 16. Drives AF-650GP General Purpose Drive. Standard Specifications. Environmental Conditions. Logic Controller (LC) Sequencer

D700 QUICK START MANUAL

AF-600 FP AC Drive AC Adjustable Frequency Drive Guide-Form Specification

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

AF-60 LP TM Micro Drive. Programming Guide

Smartstart Control Module

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

SMARTSTART MOTOR STARTERS

LOW HARMONIC DRIVE U1000

TECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Firmware Manual - EC Series Drives

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Transcription:

RUN HAND OFF AUTO RUN HAND OFF AUTO VARIOspeed Quick Start Manual for Constant Pressure Applications This VARIOspeed Drive has been factory pre-programmed for your specific pressure control application. All relevant parameters have been configured to match the provided pump data and system pressure requirements. Should you need to make minor adjustments, please consult the parameter table enclosed in this document. Consult the factory for assistance. Pressure Booster Pump Application Deep Well Submersible Pump Application VARIOspeed VFD Quick Start Manual 1

Display and Keypad DISPLAY: Monitor 4 digit LED Monitoring Hz, Amps and PSI Press the SET button to toggle the display from: - Motor speed (Hz ON) - Motor Amps (A ON) - Pressure (Hz, A & V OFF) STOP/RESET: Fault RESET SETTING DIAL: Used to scroll through parameter list and edit parameter value. MODE: To display parameters. Also used to exit back to monitoring display. SET: Used to save parameter value after editing. During operation the SET button is used to monitor motor Hz, amps and pump discharge pressure. PARAMETERS DESCRIPTION P. 2 Minimum frequency P. 9 Electronic thermal O/L relay P. 44 Acceleration time 2 P. 45 Deceleration time 2 P. 77 Parameter write selection P. 127 Pre-charge Frequency P. 129 PID proportional band P. 130 PID integral time P. 131 High pressure alarm P. 133 Pressure set point P. 160 User group read selection P. 195 Output relay 1 P. 575 Sleep timer P. 576 Sleep frequency P. 577 Start pressure (differential) P. 761 Pre-Charge Pressure P. 762 Pre-Charge Timer C. C functions Pr. CL Parameter clear AL LC All parameter clear Er. CL Faults history clear PCPY Parameter copy Example: Changing the Set Pressure 1. Press MODE to choose the parameter setting mode. (The parameter number read previously appears.) 2. Turn the SETTING DIAL until P.133 (Pr. 1) appears. 3. Press SET to read the current pressure set point value. 50.00 (initial value) appears. 4. Turn the SETTING DIAL to change it to the pressure set point value 55.00. 5. Press SET to save. Flash --- Parameter setting complete! Turn SETTING DIAL to read another parameter Press SET to show the setting again. Press SET twice to show the next parameter. Press MODE twice to return the monitor to frequency monitor. 2 VARIOspeed VFD Quick Start Manual

HAND/OFF/AUTO Operation RUN RUN light is ON when the pump is running. HAND OFF AUTO HAND/OFF/AUTO 3 position selection switch. HAND position The pump will run immediately. The motor speed is controlled manually by adjusting the setting dial on the VFD and pressing the SET button to accept. OFF position The pump will not run AUTO position The pump will not run if the pressure is above the set pressure. The pump will run if the pressure drops below the Set Pressure less the Start Pressure. Example if set the set pressure is 40PSI (P.133=40 PSI), and the Start Pressure is 5PSI (P.577=1005). The pump will start when the pressure drops below 35PSI (see example below) VARIOspeed VFD Quick Start Manual 3

Parameter List PARAMETERS DESCRIPTION RANGE DEFAULT TYPICAL P. 2 Minimum frequency 0 to 120Hz 0Hz 30.0Hz P. 9 Electronic thermal O/L relay 0 to 3600A xxx.xa xxx.xa P. 44 Acceleration time 2 0 to 360s 5s 5s P. 45 Deceleration time 2 0 to 360s 5s 5s P. 77 Parameter write selection Not used Not used Not used P. 127 Pre-Charge Frequency 9999 30Hz P. 129 PID proportional band 0.1 to 1000 100% P. 130 PID integral time 0.1 to 3600s 1s 2s P. 131 High pressure Alarm 0 to 200PSI 9999 75PSI P. 133 Pressure set point 0 to 200PSI 9999 55PSI P. 160 User group read selection Not used Not used Not used P. 195 Output relay 1 Alarm P. 575 Sleep timer 0 to 3600s 1s 10s P. 576 Sleep Frequency 0 to 400Hz 0Hz 35Hz P. 577 Start Pressure (differential) 900 to 1100% 1000% 1005 (5 PSI) P. 761 Pre-Charge Pressure 0-200PSI 9999 9999 (Disabled) P. 762 Pre-Charge Timer 0.0 to 3600s 9999 9999 (Disabled) C. C functions Not used Not used Not used Pr. CL Parameter clear Not used Not used Not used AL LC All parameter clear Not used Not used Not used Er. CL Faults history clear Not used Not used Not used PCPY Parameter copy Not used Not used Not used Minimum frequency: (P.2) The pump will not be allowed run below this frequency. It must be set at 30Hz for submersible well pumps. Electronic thermal O/L relay: (P.9) The electronic overload will trip the VFD and protect the motor from damage in the event an overload condition. Set this value to match the motor nameplate Full Load Amps. For submersible well pumps, set to the motor Max. Amps (Service Factor Amps). Acceleration/Deceleration time 2: (P.44, P.45) P.44 Acceleration rate in seconds P.45 Deceleration rate in seconds Applicable to the Acceleration/Deceleration rate from 30Hz to 60Hz. Pre-Charge function: (P.127, P.761, P762) P.127 Pre-Charge Frequency P.761 Pre-Charge Pressure P.762 Pre-Charge Timer The Pre-Charge function is used for filling a pipe at a lower speed to reduce water hammer. This is particularly useful in irrigation applications with long pipe runs. The pump will run at a fixed frequency "P.127" till the "Pre-Charge TIMER P 762" is done or the pressure reaches the "Pre-Charge PRESSURE P. 761". The pump speed will no longer be fixed after that point and automatic pressure control will resume. Caution! Always set Pre-charge pressure (P.761) below the pressure set point (P.133). It is recommended for the Precharge pressure to be set at least 20PSI below the pressure set point, even when only using Pre-charge timer 4 VARIOspeed VFD Quick Start Manual

Parameter List (P.762). PID: (P.133, P.129, P130, P131) P.133 is the Pressure Set Point (target pressure to be maintained at pump discharge). It cannot exceed the range of the pressure transducer (typically 0-200PSI). P.129 is the Proportional Band. For advanced users only. This parameter is used for adjusting the frequency output control reaction to pressure changes. Decrease for larger (faster) corrections. Default is 100%. Decrease if large pressure overshoots on start up occurs. P.130 is the Integral Time. For advanced users only. This parameter is used for adjusting the frequency output control reaction to pressure changes. Decrease for larger (faster) corrections. Default is 2sec. Decrease for faster response, increase if quick unstable oscillations occur. P.131 is the High Pressure Alarm Set Point. The VFD will stop and display E.PId if the pressure rises above this value. Typically set to 20PSI above set point (P.133) Sleep Mode: (P.575, P.576, P577) P.575 is the Sleep Timer. This timer starts when the VFD output frequency drops below the Sleep Frequency (P.575). The pump will go to sleep (pump stopped) when this timer is done (typically 10Sec). P.576 is the Sleep Frequency. The Sleep Timer (P.575) starts the VFD output frequency drops below this frequency (typically 35Hz). P.577 is the Start Pressure (Differential). The pump will start if the pressure drops below the Set Pressure less the Start Pressure. Example: If set the Set Pressure is 40PSI (P.133=40 PSI), and the Start Pressure is 5PSI (P.577=1005, the pump will start when the pressure drops below 35PSI (see example on page 3.) Typically set to 1005 (5PSI). Notes: If the system cycles on and off too frequently try the following: increase the Sleep Timer (P.575), or lower the Sleep Frequency (P.576) or increase the Start Pressure (P.577). A combination of change in all three parameters may be necessary. If the pump does not go to sleep when there is no water demand (no flow), the Sleep Frequency (P.576) must be increased. Output Relay: (P.195) VFD relay output1 can be programmed to operate on various system conditions: Set to 0 for relay activation when the pump is running. By default, the relay will be energized when the VFD is in an fault state (P.195 = 99) Terminals A1 (Normally Open Contact), B1 (Normally Closed Contact), and C1 (Common). VARIOspeed VFD Quick Start Manual 5

Faults, Alarms and Warning Codes FAULTS ALARMS E.OC1 Overcurrent trip during acceleration FN Fan alarm E.OC2 Overcurrent trip during constant speed E--- Faults history E.OC3 Overcurrent trip during deceleration HOLD Operation panel lock E.OV1 Regenerative overvoltage Er1 to 4 Parameter write error E.OV2 Regenerative overvoltage re1 to 4 Copy operation error E.OV3 Regenerative overvoltage trip Err. Error E.THT Inverter overload trip E.THM Motor overload trip WARNINGS E.FIN Fin overheat OL Stall prevention overcurrent E.IPF Instantaneous power failure ol Stall prevention overvoltage E.BE Brake transistor alarm RB Regenerative brake prealarm E.UVT Undervoltage TH Electronic thermal relay function prealarm E.ILF Input phase loss PS PU stop E.OLT Stall prevention MT Maintenance signal output E.GF Output side earth (ground) CP Parameter copy E.LF Output phase loss E.OHT External thermal relay IMPORTANT: Faults can be reset by pressing the STOP/RESET button E.PTC PTC thermistor operation on the VFD. The selector switch must be in the OFF E.OPT Option fault position to reset fault. Please contact your distributor if E.OP1 Communication option fault you are not able to reset a fault. E. 1 Option fault E.PE Parameter storage device E.PUE PU disconnection E.RET Retry count excess E.PE2 Parameter storage device E. 5 CPU Fault E. 6 CPU Fault E. 7 CPU Fault E.CPU CPU Fault E.CTE CPU Fault E.P24 24VDC power output short E.CDO Output current detection E.IOH Inrush current limit circuit E.SER Communication fault E.AIE Analog input fault E.PID PID signal fault (High pressure) E.13 Internal circuit fault E.PCH Precharge function fault 6 VARIOspeed VFD Quick Start Manual

Terminal Connections IMPORTANT Ring terminal must be used on POWER (R/L1, S/L2, T/L3) and MOTOR (U, V, W) connection. See the installation manual for sizing and torque requirements. VARIOspeed VFD Quick Start Manual 7

Low Suction Pressure Switch A low suction pressure switch or a low level switch (not included) may be used to prevent dry run pump operation. See below for connection. 220 Ohio Street Ashland, Ohio 44805 1-800-363-5842 Phone: 419-281-5767 Fax: 419-289-2535 www.csicontrols.com PN 1030013A CSI Controls 07/10 8 VARIOspeed VFD Quick Start Manual