Syr-line TMR48D Digital Timer

Similar documents
Syr-line TMR48D Digital Timer

02/11/2015

02/11/2015

08/07/2015

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

02/11/2015

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Solid-state Timer H3YN

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

812/ 814/ 815 digital timers

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Contact protection relay

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

TM3DI16 module TM3-16 inputs

Zelio Count - Counters RC87610

XPSMCMDO Digital output pairs expansion modules with screw term

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

XPSMCMDI Input expansion module with screw term

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TM3AI4 module TM3-4 analog inputs

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

TM3DI16G module TM3-16 inputs spring

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Electronic timer CT-ERD.12

Electronic timer CT-ERS.21

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM221M32TK controller M IO transistor PNP

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

RM35TF V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TM221M16R controller M IO relay

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

TM221M16TG controller M IO transistor PNP spring

Technical specifications

TM3TI4 module TM3-4 inputs temperature

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

RM35LM33MW liquid level control relay RM35-L V AC/DC

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

RZ7-FE Electronic Timing Relays

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

Output Voltage* (nom.)(adjustable)

TM3TI8T module TM3-8 inputs temperature

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

TM200C24R controller M IO relay

Electronic timer CT-AHD.22

02/11/2015

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

XPSMCMMX inputs 2 output pairs expansion module with screw term

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Electronic timer CT-ARS.11

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Model Number Structure

RM35LM33MW liquid level control relay RM35-L V AC/DC

TM221CE40T controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

TM3DI8A module TM3-8 inputs 120V AC

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM200CE24T controller M IO transistor Source+ Ethernet

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Programmable Relay ZEN V2 Units

Transcription:

yr-line MR48D Digital imer Front Panel 48x48 (1/16 DIN) Large LED or LCD creen (13.2 mm) Multi-function and single-function Basic & Advance configuration modes Multi-range (0.05 s 9999 h) Multi-voltage (24-240 V AC/DC) 1 or 2 relay outputs (Changeover) Memory option in event of a break in supply Lock function p or down timing DIN ized (48x48 mm) Housing Compact body (63 mm long) Water & Dust-proof (IP66) 8-Pins & 11-Pins connections tandard Version (MDE1) Performance Version (MDA2, MDF1, GDF1, GD2) Product election ype Part Number Function Connections Output upply Voltage creen MDE1 MDE1R0524 A, B, C, H, D, Di 8-Pins 1 x 5A 24 V AC/DC LCD MDE1 MDE1R05MVA A, B, C, H, D, Di 8-Pins 1 x 5A 100-240 V AC/DC LCD MDA2 MDA2R10MV2 A 8-Pins 2 x 10A 24-240 V AC/DC LED MDF1 MDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 8-Pins 1 x 10A 24-240 V AC/DC LED GDF1 GDF1R10MV2 A, Ac, Ad, B, C, H, L, Li, D, Di 11-Pins 1 x 10A 24-240 V AC/DC LED GD2 GD2R10MV2 A, Ab, Ac, Ad, AMt, At, B, C, H, Ht, L, Li,, W, D, Di 11-Pins 2 x 10A 24-240 V AC/DC LED Function A: ON-Delay E: Multifunction E F: Multifunction F : Multifunction Output ype R: Relay Power upply MV2: 24-240 V AC/DC MVA: 100-240 V AC/DC 24: 24 V AC/DC GD 2 R 10 MV2 ype MD: Digital 8-Pins GD: Digital 11-Pins Output Quantity 1: 1 Output 2: 2 Outputs Output Power 10: 10 A 05: 5 A Description: he new yr-line Digital imers has higher precision and many programming features with the biggest screen ever seen in the timer relays market and the most intuitive programming for ease to use and fast configuration For more information about the yr-line MR48D Digital imer please visit www.crouzet.com.

Input pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Rated supply voltage n 24 V AC/DC 100-240 V AC/DC 24-240 V AC/DC Voltage supply tolerance -15 %, +10 % 24-240 V AC/DC AC supply voltage frequency 50 / 60 Hz +/- 5% Galvanic isolation of supply / inputs Max power consumption @ n Immunity to power micro cuts No 2.5 VA (VAC) 1 W (VDC) 10 ms 24-240 V AC/DC 24-240 V AC/DC iming pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 pecified time ranges (10) Minimum control pulse duration Recovery time (after by de-energization) Repeatability etting Accuracy emperature drift Voltage drift IEC 1812-1: 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59 s, 0.1 min to 999.9 min, 1 min to 9999min, 1 min to 99h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h IEC 1812-1: 1 ms or 20 ms selectable IEC 1812-1: 120 ms Max IEC 1812-1: ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC) IEC 1812-1: ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC) ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC) ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC) Output pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Contact arrangement 1 CO (PD) 1 CO (PD) 2 CO (PD) Maximum switching voltage 250 VAC / 30 VDC 250 VAC / 10 A resistive / 125 VDC / 0.3 A resistive 250 VAC / 10 A resistive / 125 VDC / 0.3 A resistive witching current rate (resistive) Maximum switching power (resistive) NO: 5A 250 VAC / 5 A 30 VDC - NC: 3A 250 VAC / 3 A 30 VDC NO: 1250 VA / 150 W NC: 750 VA / 90 W NO / NC: 10 A 250 VAC / 10 A 30 VDC NO/NC: 2x10 A @ 40 C 250 V AC / 2x10 A @ 40 C 30 VDC NO / NC: 2x8 A @ 60 C 250 V AC / 2x8A @ 60 C 30 VDC 2500 VA / 300 W 2 x 2500 VA / 2 x 300 W Electrical life at nominal switching current rate (resistive) 1x10 5 cycles NO 7x10 4 cycles NC 1x10 5 cycles (10 A 250 VAC resistive) 1x10 5 cycles (10 A 250 VAC resistive) Minimum switching contact 10 ma / 12 VDC Maximum rate (at max switching power) 360 cycles /hour Mechanical life 10 x 10 6 cycles Dielectric strength between open contacts 1 kv / 1 min / 1 ma / 50 Hz Page 2 of 14

Insulation pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Rated Insulation voltage IEC 60664-1: 300 V Insulation coordination IEC 60664-1: Overvoltage category III; pollution degree 2 Rated impulse voltage Clearance / Creepage distances Dielectric strength Insulation Resistance IEC 60664-1: 4 kv (1.2/50 μs) IEC 60664-1: 3 mm / 3.2 mm EN-61812-1: 2.5 kv / 1 min / 1 ma / 50 Hz NFC 93 050: > 500 MΩ / 250 VDC / 1min General pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 Display 4 digits per value 7 segments LCD 4 digits per value 7 segments LCD 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight 4 digits per value 7 segments LCD with backlight Memory backup Casing Mounting position Mounting Housing material Degree of protection (Front Face) Degree of protection (Housing) EEPROM (rewrite 1,000,000 times min, 40 years data hold min) 48x48 mm (1/16 DIN) All positions Mounting Front panel, by clip Mounting base-mounted on socket L94: enclosure plastic type V0 IEC 60529: IP66 with front panel seal IEC 60529: IP20 Operating temperature IEC 60068-2: -10 C to +60 C torage temperature IEC 60068-2: -30 C to +70 C Humidity Vibration resistance hock resistance Drop to concrete floor Weight IEC 60068-2-30: 93 % without condensation IEC 60068-2-6: ±0.15 mm 10 Hz - 60 Hz 2 g 60 Hz - 150 Hz IEC60068-2-27: 15 gn 11 ms, 3 x 6 axis (Output non-energized) 5gn 11 ms, 3 x 6 axis (Output energized) IEC 60068-2-32: Height: 0.75 m Approx. 105 g (150 g with packing) Page 3 of 14

tandards pecifications Description MDE1 24 MDE1 MVA GDF1 MDF1 MDA2 GD2 E Directives Approvals / Marking ecurity standard Conformity with environmental directives Product standard Immunity to electrostatic discharges Immunity to radiated, radio-frequency, electromagnetic field Immunity to rapid transient bursts Immunity to shock waves on power supply Immunity to radiofrequency in common mode Immunity to voltage dips and breaks AC/DC main port emissions Radiated emissions 2014/30/E: EMC, 2014/35/E: Low voltage CE, clus Listed Industrial Control Equipment IEC 60664-1: Insulation coordination for equipment within low-voltage systems 2015/863/E: RoH 1907/2006: Reach 2012/19/E: WEEE IEC 61812-1: pecified time relays for industrial use L 508 (60947-4-1): Industrial Control Equipment (NRN- Industrial Control witches) Level III Air +/-8 KV / Contact +/-6 KV IEC61000-4-3: Level III, 10 V/m (80 MHz to 1 GHz) 80% AM (1 khz), 3 V/m (1.4 to 2 GHz) 80% AM (1 KHz), 1 V/m (2 to 2.7 GHz) 80% AM (1 KHz) IEC 61000-4-4: Level IV, direct +/-4 kv (power supply) / capacitive coupling clamp +/-2 KV, (command input and outputs) IEC 61000-4-5: Level III, line-to-earth +/-2 kv / line-to-line +/-1 kv IEC 61000-4-6: Level III, 10 Vrms (0,15 to 80 MHz) 80% AM (1 khz) IEC 61000-4-11: Industrial Class II, 0 % residual voltage during 1 cycle AC power ports, 70 % residual voltage during 25/30 cycles AC power ports, 0 % residual voltage, 250/300 cycles AC power ports. Residential: 0 % residual voltage during 10 cycle AC power ports, 40 % residual voltage during 10 cycles AC power ports, 70 % residual voltage during 10 cycles AC power ports, 0 % residual voltage, 250/300 cycles AC power ports EN55022 / CIP2 Class B EN 55011 / CIPR11 Class B, Group 1 EN55022 / CIP2 Class B EN 55011 / CIPR11 Class B, Group 1 Page 4 of 14

Accessories ocket for DIN Rail or Panel Mount ocket for DIN Rail or Panel Mount ocket with crew erminal Plug-In 8-Pins Plug-In 11-Pins Plug-In 8-Pins 25 622 130 25 622 080 25 622 203 older Plug older Plug ocket with crew erminal Plug-In 8-Pins Plug-In 11-Pins Plug-In 11-Pins 25 622 301 25 622 076 79 694 002 Page 5 of 14

Diagrams Wiring Diagrams MDE1 24 MDE1 MVA MDF1 GDF1 MDA2 GD2 Page 6 of 14

Dimensions in(mm) ide View Front View Mounting Panel Cut-Out Page 7 of 14

Function Diagrams Basic ime Chart A FNCION A: On-Delay (Delay on make) IN BAIC IME CHAR R1/ IN Detailed ime Chart DEAILED IME CHAR NO ED R1/ t FNCION A + Memory Option BAIC IME CHAR DEAILED IME CHAR NO ED R1/ IN R1/ IN t1 t2 FNCION Ab: Delayed Interval BAIC IME CHAR DEAILED IME CHAR Ab R1 / BAIC IME CHAR R1/ IN 1 2 IN 1 2 1 t 1 t 1 2 FNCION Ab IMED + Memory R1 / Option IN DEAILED IME CHAR 1 2 R1/ R1/ IN 1 2 IN 1 2 1 t1 t2 1 t 1 2 1 2 FNCION Ac: On/Off Delay (Delay on make/break) BAIC IME CHAR Ac R1 / R1 / IN BAIC IME CHAR IN 1 2 1 t2 2 t1 t1 1 t1 1 R1 / IN 1 2 Page 8 of 14

FNCION Ac + Memory Option R1 / R1 / IN 1 2 IN t2a+t2b=2 1 t2 t2a t2b t t 1 t 1 2 1 FNCION Ad: Delay on Ad R1 / R1 / IN IN t1 t1 FNCION Ad + Memory Option R1 / R1 / IN IN t1 t2 =t1+t2 FNCION At: ummation ime Relay At R1 / R1 / IN IN =t1+t2 t1 t2 =t1+t2 t1 t2 t1 t2 FNCION At + Memory Option R1 / R1 / IN IN =t1+t2 t1 t2 =t1+t2 t1 t2 t1 t2 t1 t2 Page 9 of 14

FNCION AMt: On-Delay (Delay on make, otal memory: one delay) NO ED AMt R1 / R1 / IN =t1+t2 t1 t2 IN t1 t2 FNCION B: One-hot =t1+t2 B R1 / R1 / IN IN t t FNCION B + Memory Option R1 / R1 / IN IN =t1+t2 t t1 t2 FNCION C: Off-Delay (Delay on break) C R1 / R1 / IN IN t t FNCION C + Memory Option R1 / R1 / IN IN =t1+t2 t t1 t2 t Page 10 of 14

FNCION H: Interval H IN R1 / R1 / NO ED IN t t FNCION H + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t t1 t2 FNCION Ht: interval summation time relay Ht R1 / R1 / IN =t1+t2 t1 t2 IN =t1+t2 t1 t2 t1 t2 FNCION Ht + Memory Option R1 / R1 / IN =t1+t2 t1 t2 IN =t1+t2 t1 t2 t1 t2 t1 t2 FNCION L: Recycler (OFF ) NO ED L IN R1 / 1 2 1 2 R1 / IN 1 2 1 2 1 1 2 1 1 Page 11 of 14

FNCION L + Memory Option NO ED R1 / IN R1 / 1 2 1 2 IN 1 = t1 + t2 1 2 1 2 t1 t2 2 1 1 t FNCION Li: Recycler (ON ) NO ED Li IN R1 / 1 2 1 2 R1 / IN 1 2 1 2 t 1 2 1 t 1 FNCION Li + Memory Option NO ED R1 / IN R1 / 1 2 1 2 IN 1 = t1 + t2 1 2 1 2 t1 t2 2 1 t 1 t FNCION : On-Delay (Delay on make): sum of times R1 / R1 / IN = t1 + t2 + t3 t1 t2 t3 FNCION + Memory Option IN = t1 + t2 + t3 t1 t2 t3 t1 t1 t2 t3 R1 / R1 / IN = t1 + t2 + t3 t1 t2 t3 IN = t1 + t2 + t3 t1 t2 t3 t1 t2a t2b t2 = t2a + t2b t3 Page 12 of 14

FNCION W: iming after pulse of control contact W R1 / R1 / IN IN t t FNCION W + Memory Option R1 / R1 / IN IN 1 = t1 + t2 t t1 t2 FNCION D: ymmetrical flashing (OFF start) D IN R1 / R1 / NO ED IN 1 FNCION D + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t1 t2 t FNCION Di: ymmetrical flashing (ON start) Di IN R1 / R1 / NO ED IN t t Page 13 of 14

FNCION Di + Memory Option NO ED R1 / IN R1 / IN = t1 + t2 t1 t2 t t Keys Function et ime Check Configured ime and Function ime Programming Mode Page 14 of 14

Programming Mode Programming Main Menu # Parameter Value 1 Pass If "Lock" function is on, pass needs to be entered 0000 2 Basic Prog Enter to Basic Programming Mode 3 Advanced Prog Enter to Advanced Programming Mode 4 est Enter to est Mode Basic Prog Menu # Parameter Value 1 Function elect the timing function A Ab Ac Ad AMt At B C H Ht L Li D Di W 2 ime Range elect the timing range -.---s --.--s ---.-s ----s --m--s ---.-m ----m --h--m ---.-h ----h 3 Count elect the timing count up or down p Down 4 Memory Activate memory option (save timing after power off) Off On 5 Output 2 elect if Out 2 works timed or instantaneous (MDA2, GD2) imed Instantaneous Advanced Prog Menu # Parameter Value 1 Input ime elect input time wave 0.020s 0.001s 2 Input ype elect input to work with a NPN or PNP signal PNP NPN 3 ime Limit elect upper time limit 9999 0000 Page 15 of 14

4 Brightness elect screen brightness 100% 50% 5 leep After elect the time needed to turn off the screen Off 5s 10s 30s 60s 6 Lock elect security level 1 (lock configuration) or 2 (lock all) Off 1 2 6.1 Pass et password for lock option 0000 6.2 Done Indication that the lock is on 7 Default ettings settings to default values No Yes 7.1 ure Confirm if reset settings to default values No Yes 7.2 Done Indication that settings have been reset est Mode Menu # Parameter Value 1 Out 1 urn on/off Relay Output 1 Off On 2 Out 2 urn on/off Relay Output 2 (MDA2, GD2) Off On 3 Display urn on/off all display segments Off On 4 Memory est the memory of the timer Off est 4.1 Good Indication that the memory is working properly 4.2 Error Indication that the memory is not working properly All specifications in this document are subject to change without written notice. Actual product may differ from pictures provided in this document. Page 16 of 14