Operators Manual. Fort Atkinson, Wisconsin USA. Digi-Star International Pannigen, The Netherlands D3973 Rev D

Similar documents
TST7600 Touch Screen with TMR Tracker OPERATORS MANUAL

TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE...

RJ-2030/2050/2140/2150

Stock Weigh 300. Operators Manual HELLO. Ft. Atkinson, Wisconsin USA. Panningen, The Netherlands

RJ-2030/2050/2140/2150

PX Series Balances. Quick Start Guide. Please download the user manual from

iq DIGITAL PICTURE FRAME iq Digital Picture Frame DPF701SB USER GUIDE

FT-20 Fire Training Fog Machine User Manual English

FUNTRONIX SCORE-N-TIME TM. T-240/T-260 Universal Up/Down Clock/Timer OPERATING MANUAL. Revision July 5, 2015

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

4 Message Paging System

CF3000 Dealer Diagnostic Tool Instruction Manual

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

FT-20 Fire Training Fog Machine User Manual English

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

DTC P0AA6 - High Voltage Isolation Fault

Please read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.

LVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors

User Guide Microsoft Portable Power (DC-21)

1. Place your CD driver in your PC drive for software installation 2. Follow the instruction on the screen to finish the software installation

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

EnCell Battery Cell Monitor

DOT MATRIX PRINTER SP6000 SERIES

FTE-6000 Hand Held Tuneable Laser Source

Allworx 24x Service and Troubleshooting Guide

Fixed Wireless Phone. User Manual

Seed App User Manual. Seed PC Application Available

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

TASER CAM HD Recorder User Manual

THE BULLET. Bluetooth Speaker with NFC Technology. Instruction Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Operating Instructions for Orderman Sol & Sol+

Grain Tracker Operators Manual

DOWNLOAD PDF DELL VENUE 8 PRO 5830 MANUAL

Operating Instructions STX Series Digital Strap Tension Meter

FROG-4000TM Quick Start Guide

aframe electrorganic percussion Quick Start Guide

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

ZTE MOBILE HOTSPOT QUICK START GUIDE

HX1 Bluetooth Stereo Headset

Advidia A-15 & A-35 Installation Manual

Verifoam Conductivity Tester

Excalibur Wireless Tickers

Operator s Manual. 3-D Scanning Probe. Warranty Safety Features Setup Operation. Please save this manual for future reference.

Universal Remote Controlled Lamp Dimmer User s Manual

DP-152. Digital Picture Viewer. Instruction Manual. Please read this manual carefully before operation 152SX

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

CAP18 CAP30 U S E R S M A N U A L CONTENTS. 2 Why use a power capacitor? 2 Features. 4 Installation precautions

JanusRAID SA-6692J Hardware User Manual

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

Installation Instructions

PORTABLE HOME SECURITY VIDEO CAMERA

Reference Guide for the KODAK Picture Kiosk GS Compact. Software Version 2.0

7 Digital Photo Frame

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Do not attempt to service the unit yourself. Seek assistance from a qualified professional.

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

User Guide. Tech Pro Link. First Edition Third Printing Part No GT

ATW-CHG3 / ATW-CHG3N. User Manual TWO-BAY CHARGING STATION

User Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction

Greco Systems. License Manager. Operation Manual OM A division of e-dnc Inc. 303 E Gurley St. #522 Prescott, AZ USA

Please read this guide before using the printer

Blackbird 4K Multi Format HDMI Converter with 4K Scaler

Model 2380 Rack-Mount Kit

ISP Tester. Operating Instructions

Moving money forward CASSIDA INSTACHECK COUNTERFEIT DETECTOR

DIGI-STAR. GT560 Scale Indicator Software Update Instructions. Referenced Document for: Service Bulletin:

Instruction Manual. Read this manual carefully before using your weigh scale D3812

AC/DC TRUE RMS CLAMP METER ACM-2036

Daily use. indicating that the loud speakers

Smart Stack Paging System

Multi-touch Touch-Screen. Installation Guide

Thank you for your purchase USER MANUAL

Rapid deployment surveillance system

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

NE400 - LED MOTION LIGHT WITH VIDEO CAMERA

Welcome 1. Precaution

THUNDERBAY 4. Assembly Manual & User Guide

Power. Document Part Number: This guide explains how the computer uses power. March 2006

TABLET DOCK USER S GUIDE

Table of Contents. 1.Introduction... P.2. 2.Product Tour... P Operating Instructions... P Important Notes... P.10

Quick Start Guide. Introduction. P4T/RP4T Overview

TABLET PC. Quick Start Guide. Model: TVE100 I

Dell XPS 14z Owner s Manual

Professional DMX Stage Backdrop

Smartphone Photo Printer

Model: PTTC4U. Multifunction Turntable With MP3 Recording, USB-to-PC, Cassette Playback

Smartphone Photo Printer Item No

Smartphone Docking Station with Speaker and Bed Shaker

Power. Document Part Number: This guide explains how the computer uses power. December 2005

MX3 BT LED Party Tube

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Homework 13: User Manual

THUNDERBAY 4 MINI. Assembly Manual & User Guide

UHF WIRELESS MICROPHONE WM-4310A WM-4310H

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Transcription:

Operators Manual Fort Atkinson, Wisconsin USA Digi-Star International Pannigen, The Netherlands www.digi-star.com AUGUST 28, 2015

LINKS Follow the link below to a video on Digi-Star s web site showing how to use Moisture Tracker TM. digi-star.com/solutions/2-13/moisture_tracker To activate the Moisture Tracker TM software license, see page 38 for a direct link to Digi-Star s software license activation page and instruction. For Moisture Sensor v2.11f D3973-US Moisture Tracker Operators Rev D SAC 2 Moisture Tracker TM Operators Manual

CONTENTS LINKS...2 MOISTURE TRACKER TM FEATURES...4 SAFETY...4 DEVICE OVERVIEW...5 OPERATION...10 Install USB Drive...10 Updating Data Using USB Drive...10 Managing On-Board Data...10 Cleaning Probe Head and Grate...10 Turn On Moisture Tracker TM Device...11 MAIN MENU...12 MOISTURE MEASUREMENT...13 Notes on Taking Moisture Measurements...14 Individual Ingredient Moisture Adjustment...15 Farmer Mode...19 Set Date and Time...20 Set Measurement Count...21 Set Power Down Time...22 Set Screen Dim Time...22 Set Defogger Level...23 Calibrate Sensor...24 Calibration Procedure...25 Enter New Calibration Code...26 Set Worker Operating Mode...27 Set Worker Options...28 Diagnostics...29 PREVIOUS READINGS...29 ABOUT THIS DEVICE...30 SET LANGUAGE...32 MOISTURE TRACKER TM INFORMATION...33 Batteries...33 Low Battery...33 Charging Battery Pack...33 Repair Parts...33 UPDATING MOISTURE TRACKER TM SOFTWARE...34 LICENSE...38 Moisture Tracker TM Operators Manual 3

MOISTURE TRACKER TM FEATURES Moisture Tracker TM determines percentage of moisture in ingredients fed to livestock and therefore dry matter can be determined. A photometer in this device measures light reflected from ingredient sample and determines moisture. Then a set of readings is averaged and results displayed for user and stored for transfer to a PC. SAFETY This SAFETY ALERT SYMBOL indicates important safety messages in the manual. When you see this symbol, be alert to the possibility of PERSONAL INJURY and carefully read the message that follows. Indicated an imminent hazardous situation that, if not avoided, will result in serious injury or death. Indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury, and includes hazards that are exposed when guards are removed. Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury. The functioning and operational safety of this device can only be ensured if user observes usual safety precautions as well as specific safety guidelines stated in these operating guidelines: IMPORTANT: Before connecting device to electrical supply, ensure the operating voltage stated on power adapter corresponds to voltage supplied to adapter. Transmitter controls, maintenance and repair work must only be carried out by a qualified technician. If there is any reason to assume the product cannot be used without risk, it must be marked to prevent further use. 4 Moisture Tracker TM Operators Manual

Do not take moisture measurements from open face of a feed bunk over 8 feet high due to risk of silage collapse. Do not stand closer than three times (3X) the height of the face. Take samples from loader bucket or small pile after it has been moved a safe distance from the silage face. DEVICE OVERVIEW The following items are included with the Moisture Tracker TM : Case 115VAC Charger Moisture Tracker TM with USB Memory Device 12VDC Charger Calibration Target Moisture Tracker TM Operators Manual 5

Probe Grate Battery in handle Trigger Charging Port 6 Moisture Tracker TM Operators Manual

Slide lock back to open USB drive cover This port for factory use USB drive port for data transfer USB drive contains the Moisture Tracker TM PC Software, and this operators manual in PDF format. Moisture Tracker TM Operators Manual 7

8 Moisture Tracker TM Operators Manual

Number Description Function/Use /Operation 1 Power Button Turns Moisture Tracker TM on/off 2 Home Press to return to Main Menu screen 3 Back Press to return to previous display mode screen 4 Select/Enter Press to select highlighted item- Device Display Mode changes according to highlighted menu option; also can be used in place of trigger 5 Left Arrow/Reject 6 Right Arrow/Accept 7 Down Arrow Press to scroll down Press and release to scroll left; also used to delete or reject Press to scroll right; also used to accept 8 Up Arrow Press to scroll up 9 Preset 1 Press to select ingredient assigned to Preset 1 and proceed directly to measurement 10 Preset 2 Press to select ingredient assigned to Preset 2 and proceed directly to measurement 11 Preset 3 Press to select ingredient assigned to Preset 3 and proceed directly to measurement 12 Preset 4 Press to select ingredient assigned to Preset 4 and proceed directly to measurement 13 Indicator LEDs Indicate system responses and errors Moisture Tracker TM Operators Manual 9

OPERATION Install USB Drive Before turning on device, install USB drive in USB port. See page 11. USB drive is required when software files need updating and data collection. Using the removable drive, data is downloaded to a PC for analysis using Digi-Star software. Note: Turn Moisture Tracker TM off before removing USB drive. Updating Data Using USB Drive (See page 34 for full procedure) To update data, ingredient calibrations, software and firmware: 1. Load updates onto a USB drive from Moisture Tracker TM software loaded on a PC. 2. Insert the USB drive with updates into Moisture Tracker TM. 3. Power up device and it will automatically update software and data files. Managing On-Board Data To manage on-board data, the USB containing the data must be removed from the Moisture Tracker TM and plugged into a PC with Moisture Tracker TM software loaded. Cleaning Probe Head and Grate To clean probe head of debris that may cause measurement interference, remove probe grate by grasping grate in hand and turn counter clockwise to release. Wash grate with water or wipe clean using a damp towel. Clean window using a clean microfiber cloth dampened with water or methanol. Do not use window cleaner and a rag. Avoid excess liquid in this area. Reinstall grate positioning it over probe head and twist clockwise to attach, a slight click will occur once grate is seated properly. 10 Moisture Tracker TM Operators Manual

Turn On Moisture Tracker TM Device To turn on Moisture Tracker TM, depress the Power button for 2 seconds. Power Button USB drive connected to USB port Moisture Tracker TM Operators Manual 11

MAIN MENU Reach Main Menu home display by pressing. Use and arrows then button for menus. See page 8 and 9. 1 2 3 4 1. Menu Icon A= Administrator F=Farmer W=Worker 2. Menu Title 3. Battery Voltage Indicator 1 Bar = Minimum 4 Bars= Maximum Lightening Bolt= Charging 4. Date and Time 5. Charger plugged in-no measurements allowed. Main menu continued 5 12 Moisture Tracker TM Operators Manual

MOISTURE MEASUREMENT Select Measurement press Information on farms and ingredients are first entered into the Moisture Tracker TM software on a PC, then downloaded to the device by means of a USB drive. Select farm; shows ingredient list for that farm. Select ingredient using arrows, press and Moisture Tracker TM Operators Manual 13

See Notes below. Press Trigger or Number of trigger presses necessary for a moisture measurement is controlled by the Set Measurement Count screen. Default is 20. Trigger pulls are counted and screen displays ingredient being measured. In this case, corn silage. Results are displayed and information stored in USB drive for later uploading to PC. Press any key will return to the ingredient screen. Note: The previous days DM measurement (if available) will show below the ingredient. Notes on Taking Moisture Measurements USB drive must be in device to save measurements. Prior to taking first measurement, ensure probe grating is in place and free of debris interfering with light transmission. Hold probe head squarely against ingredient to make uniform contact with probe grate. The weight of the device is enough force. Be careful not to force ingredient through probe grate. Watch Video on Digi-Star.com or contact Dig-Star technical support for addition information on taking moisture measurements. 14 Moisture Tracker TM Operators Manual

Individual Ingredient Moisture Adjustment Allows user to add an adjustment to each individual ingredient so the Moisture Tracker TM reading will match readings obtained from user reference dry-down methods such as lab, microwave, dehydrator etc. The adjustment is added to the calculated dry matter (DM) before the reading is displayed. The displayed value is the adjusted value. Worker may make this adjustment if Ingredient Adjustment is checked on the worker options screen. See page 28. Select Measurement press Select desired farm, press Moisture Tracker TM Operators Manual 15

Select ingredient using and arrows. Press for 5 seconds brings up an adjust window. Use the and arrows to move the red line before or after the decimal point. Use the and arrows to increase or decrease the number. Press NOTE: The default range for adjustment is +/-5.0. The range can be expanded to +/-15.0. See next page. Press to select Yes and then press Press selects No During measurement, adjustment value shows in parentheses. 16 Moisture Tracker TM Operators Manual

After measurement, adjustment value shows in parentheses. To Expand Adjustment Range At Main Menu press arrow to select Settings. Press At Settings press arrow to select Set Adjustment Range. Press Moisture Tracker TM Operators Manual 17

Press and arrows. to set adjustment range between 5 and 15. A setting of 10 means the ingredient can be adjusted between +10 and -10. 18 Moisture Tracker TM Operators Manual

Farmer Mode For initial setup of the Moisture Tracker TM, go to main menu by pressing the key. At Main Menu press arrow to select Settings. Press select Set Operating Mode. Press Select Farmer Moisture Tracker TM Operators Manual 19

At Settings press Set Password then and select Default password is 2468 Press or, or press to enter a password of 4 characters minimum. Press X to erase any characters. When finished,press return then IMPORTANT: Write down your password below. Set Date and Time After initial farmer setup, Main Menu shows an F icon in top left hand corner. To Set Date and Time select Settings,press 20 Moisture Tracker TM Operators Manual

Select Set Date And Time Press or arrows to move yellow triangle. Press or arrows to change the month, day and time, then Set Measurement Count Select Set Measurement Count then Number of Measurements is number of times trigger is depressed when taking a moisture reading. Default is 20. Press or arrows to set number of measurements. NOTE: Set Number of Measurements higher for better accuracy on inconsistent forage. Moisture Tracker TM Operators Manual 21

Set Power Down Time Select Set Power Down Time Press Power Down Time is time device takes to power down after no user input. Use or arrows to change time, press NOTE: Device won t power down if set to zero. Set Screen Dim Time Select Set Screen Dim Time press Screen Dim Time is time device takes to dim screen after no user input. Use or arrows to set time,press NOTE: Screen won t dim if set to zero. 22 Moisture Tracker TM Operators Manual

Set Defogger Level Select Set Defogger Level press Set Defogger Level to prevent moisture from condensing on probe glass. Periodically check the sensor glass for condensation, especially in cold temperatures. If condensation is found on the sensor glass, increase the Defogger level Use or arrows to change level, to match ingredient category, press to save. Moisture Tracker TM Operators Manual 23

Calibrate Sensor For accurate measurements, the device must be calibrated using the calibration target supplied with the device. Each calibration target has a 6 digit number on the disk. Use this number during the calibration sequence shown on page 25. IMPORTANT: Before calibrating, ensure that device glass and calibration target are clean, even a small amount of dirt can cause poor results. six digit calibration code The first time the Measurement section is entered on a new calendar day, this message will appear. Verify Calibration is strongly suggested to ensure best results. Press to start calibration procedure shown on page 25. OR Press and to continue with measurements. For best accuracy: Keep the grate clear of debris while taking samples. Check glass for debris,even a small speck can affect readings. Turn the Moisture Tracker on to warm-up for 15 to 45 minutes before getting started. In hot or cold weather, place the unit outside to acclimate it to the temperature. Check calibration often using the Calibration Target provided. Every 10 to 30 minutes is recommended. Re-calibrate the moisture Tracker every-day and whenever the calibration percentage drops below 99.5%. If time permits, re-calibrate if results are below 99.8%. Better results will be generated when the calibration percentage is closer to 100%. See page 25 for procedure. NOTE: If your calibration target is stained or damaged, replace with PN 409366. 24 Moisture Tracker TM Operators Manual

Calibration Procedure Press to return to main menu. Select Calibrate Sensor, press menu. to go to calibration Make sure the six digit Code in the lower right hand corner of the screen matches the calibration code on the calibration target. IMPORTANT: If the codes do not match, see page 26 to set code in the device. calibration target, inside view Remove probe grate from device. See page 6. Attach calibration target to device. Press 1 to do a quick check of the calibration. (This takes under 5 seconds.) There are 3 possible outcomes for calibration: Pass is >/= 99.5% Warning is between 99.00% and 99.49% Fail is < 99.00% calibration target, outside view Moisture Tracker TM Operators Manual 25

If a warning appears, verify cleanliness of glass. Press 2 to re-calibrate if 99.5% or below. (This takes less than 1 minute.) If calibration is successful, a pass calibration screen will display. Device is now ready for use. Press to return to Main Menu. After calibration is complete, store calibration target in a safe place and install the probe grate on the device. IMPORTANT: Measuring without the probe grate in place will result in incorrect readings. Enter New Calibration Code For new device or if a new calibration target is purchased; the device calibration code must match the calibration target code. Press 3 on Calibrate screen will display this screen. Press or to move yellow pointer. Press or to change numbers. Press Press to return to Main Menu. 26 Moisture Tracker TM Operators Manual

Set Worker Operating Mode From Main Menu select Settings Press Use or select Set Operating Mode Press Select Worker then Press NOTE: To set worker options see page 28. IMPORTANT: A password is required to return from Worker mode to Farmer or Administrator mode. See page 20. A worker icon shows in upper left corner. Allows worker to take and store measurements. Worker can only change settings if given access to do so by the Farmer or Administrator through Worker Options. Moisture Tracker TM Operators Manual 27

Set Worker Options From Main Menu in Farmer or Administrator Mode, Select Settings then Select Set Worker Option Press Press or to select Press to check box Press to uncheck box 28 Moisture Tracker TM Operators Manual

Diagnostics Select Diagnostics press Press and arrows to view information. Press 2 highlights calendar icon at bottom of screen. Use or to show farm and ingredient information. Press 1 to go back PREVIOUS READINGS Use or arrow keys select Previous Readings, press Use or arrow keys select farm, press Press to view all farms Moisture Tracker TM Operators Manual 29

Note: All DM readings taken after software version v1.97 will only show 1 digit after the decimal point. All previous measurements are displayed for that farm. Use or arrows to scroll screen Press and hold 1, after a warning, delete highlighted row. Press and hold 2, after a warning, deletes all measurements from a selected day. Press and hold 3, after a warning, deletes all measurements for this farm. ABOUT THIS DEVICE Select About this Device, press Information example, press for Main Menu. 30 Moisture Tracker TM Operators Manual

1 Press to save device information to USB drive. Press to cancel Press to highlight OK Press Device information is stored on USB drive. Press Press Moisture Tracker TM Operators Manual 31

SET LANGUAGE Select Set Language, press Press or to select language. Press To return to previous screen. Press or to select Definir o Idioma Press 32 Moisture Tracker TM Operators Manual

MOISTURE TRACKER TM INFORMATION Batteries Moisture Tracker TM uses a rechargeable battery pack located in trigger handle. To remove or change batteries, use a Phillips head screwdriver to unscrew the cover. IMPORTANT: Only use a battery pack supplied by Digi-Star. Part number 408985 Low Battery The battery icon will begin blinking red when battery voltage is critical (< 10%). The indicator LEDs will also flash. Charge battery before next use. Charging Battery Pack NOTE: Batteries will not charge below 32 o F (0 o C) or above 113 o F (45 o C) IMPORTANT: Use only AC or DC charger supplied with the device. Plug AC battery charger into a 115VAC outlet. DC battery charger uses a 12VDC outlet. Charger cord connects to charging port on side of device. A complete charge may take up to 12 hours if device is fully discharged. When fully charged, unplug the device. The displayed battery charge level shows 4 bars. Repair Parts 405483 USB Memory Drive (Blank) 408305 Probe Cover Grate 408883 Cig. Lighter Adapter (12VDC) 408884 AC Power Adapter 408962 USB Latch Body Cover 408963 USB Latch Tab 409366 Calibration Target 408985 Battery Pack 7.2V NIMH 409093 USB Cover Assy. Moisture Tracker TM Operators Manual 33

UPDATING MOISTURE TRACKER TM SOFTWARE (HAND-HELD-DEVICE) There are 3 parts to the Moisture Tracker TM software that can require periodic software updates: 1. Moisture Tracker TM Software Graphic User Interface 2. Moisture Tracker TM Calibration List List of ingredient that can be measured 3. MoistureCompute DLL Software that converts NIR readings to moisture content Update Software 1. Remove the USB drive from the Moisture Tracker TM hand-held device. 2. Insert the USB drive into a port on the PC. 3. Start Moisture Tracker TM program on a PC. 4. Select Help and Hand Held Updates from the drop down menu. 34 Moisture Tracker TM Operators Manual

5. Select latest software revision. 6. Select Download. 7. Verify Download Com plete message. Update Calibration List and DLL 8. Select Help and Check For Calibration Updates from the drop-down menu. 9. Follow the menu, update the calibration list and MoistureCompute if required. NOTE: The calibration list and the MoistureCompute DLL may have been automatically updated upon startup. See settings menu. Moisture Tracker TM Operators Manual 35

Send Ingredients to USB Drive A B C 10. A. From the Moisture Tracker TM main menu click on the Send/Retrieve Data icon. B. From the Send Data tab, in the Send column, click ingredients to be sent to the USB Drive. OR C. Click on Select All to check all ingredients. A 11. A. After selecting the ingredients to send to the USB drive, click on Send Ingredients. This will save the updated data to the USB drive. 36 Moisture Tracker TM Operators Manual

12. Select Safely Remove Hardware 13. Select Eject Mass Storage 14. Remove USB drive. Insert USB Memory Stick in Hand-Held Unit 15. Insert USB drive into Mois ture Tracker TM hand-held device. 16. Power Moisture Tracker TM on and it automatically loads the new software into memory while starting up. 17. Select About this Device in the main menu to check the software revision. Moisture Tracker TM Operators Manual 37

LICENSE A temporary license is included with the Moisture Tracker TM. A 1 year license is included with the initial purchase and must be activated using the Digi-Star website below. For first time Moisture Tracker TM software activation: 1. The link below leads to Digi-Star s software activation site. digi-star.com/store/mt_activate.php 2. At this site, Enter the 16 digit ID number found on the Moisture Tracker TM in the About this Device menu. ID# : : ; : : : : 3. Click on Activate and Download License and follow the direction on the site to download the license to the USB drive and put the USB drive into the Moisture Tracker TM and turn on. All rights reserved. Reproduction of any part of this manual in any form whatsoever without Digi-Star s express written permission is forbidden. The contents of this manual are subject to change without notice. All efforts have been made to assure the accuracy of the contents of this manual. However, should any errors be detected, Digi-Star would greatly appreciate being informed of them. The above notwithstanding, Digi-Star can assume no responsibility for errors in this manual or their consequence. Copyright! 2014 Digi-Star, Fort Atkinson (U.S.A.). 38 Moisture Tracker TM Operators Manual

This Page Intentionally Blank Moisture Tracker TM Operators Manual 39