INSTALLING INSTALLING INSTALLING

Similar documents
INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

INSTALLING INSTALLING INSTALLING

Architect User s Guide

INSTALLING INSTALLING INSTALLING

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Installation Guide AHA-1540CP/1542CP. ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

READ ME FIRST Windows 95/98/Me/2000

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

READ ME FIRST Windows 95/98/Me/2000

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

Express5800/320La System Release Notes

Ground Isolated RS422/RS485 Serial PCI Card DB9

82341C HPIB Installation and Troubleshooting Agilent ChemStations on Windows 95 and Windows NT

WARNING USING THIS SOFTWARE IS NOT A TRIVIAL UPGRADE TO EXISTING RAID INSTALLATIONS!

IntelliServer RAS 2000 TM PowerRack Windows NT Supplement

Architect Userís Guide

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

READ ME FIRST Windows 98/ME/2000

$ERXW<RXU9,%5$Œ&DUG. Introduction

READ ME FIRST. *DSL Equipment Installation Guide: Efficient Networks 5260

Quick Reference for shmdefine

QSC(LP)-100. User's Manual

Anonymous Proxy Detection

Release Notes CCURDSCC (WC-AD3224-DS)

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

SCO Driver Installation Release Notes

Digi document reference number: _A

AHA-3980/3980W AHA-3985/3985W

Serial ATA PCI RAID Quick Installation Guide

Instruction Guide. 2 Channel Ultra ATA/100 PCI Card PCI2IDE100. The Professionals Source For Hard-to-Find Computer Parts. Revised: December 5, 2002

Apex-ICE Universal Emulator Hardware and Software Installation Guide

Installation AC Power Supply

PCI-36C QUICK INSTALLATION GUIDE

Getting Started Guide

DDA-06 External DAS Driver

Installation and User's Guide

ESC(LP)-100. Eight Channel Low Profile RS-232 Asynchronous Communications Adapter. for PCI bus. User's Manual

GE Security. Digia Client. User Manual. imagination at work

Upgrade Guide. GWAVA 4.51 to GWAVA 5

Intel Desktop Boards D845HV and D845WN Quick Reference

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Introduction to VME. Laboratory for Data Acquisition and Controls. Last modified on 4/16/18 5:19 PM

VMEbus MVC Sierra 16 port Asynchronous Serial Commux

HP / HP HPIB Driver Installation and Troubleshooting ChemStation Version A.07.0x- A.08.0xon Windows NT

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

Installing the Cisco Unified Videoconferencing 3545 MCU

ADSP-218x Family EZ-ICE Hardware Installation Guide

Instruction Guide. Two Port ISA Serial Card ISA2S550. The Professionals Source For Hard-to-Find Computer Parts

Serial ATA PCI RAID Quick Installation Guide

5 Series MSO Option SUP5-WIN SSD with Microsoft Windows 10 Upgrade Kit Installation Instructions

RACK-220 CHASSIS USER S MANUAL

Digia Client. User Manual

TMB15 User Manual. Ref: 15 M 711

Xtreme/104. PC/104 Serial Communications. User Manual

Intelligent 3.3 volt/5 volt High Speed Serial PCI Card

MAP/950 SERIAL I/O CARD INSTALLATION MANUAL

Summit-ICE Emulator Hardware User s Guide

LF719KB Quick Installation Guide V0.1 Initial Draft

ST9550 Family: AT Interface Drives. Installation Guide

HP NetServer E 800 Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Vendor Registration and Training

PCIe SATA II Channel RAID Card. User Manual

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

Installation Guide. Wyse R Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

Downloading Proposals Tutorial

Throughout this manual we use notes to make you aware of safety considerations:

D-Link DGE-528T. Gigabit Ethernet PCI Adapter. User Manual. Rev.5.0

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

indus technologies IDEX 300 Hard Drive Switch Installation & Operation For SATA Drives

Optical Disc Laminator

Series 3700 Screw Terminal Assemblies Installation Instructions

Mac OS 8 Installation Instructions for Sonnet Presto and Presto Plus Processor Upgrade Cards

Figure 1.0 ULTRA 22C Board Layout JP1 JP5. Table 1.0 Default Jumper Settings

CST8207: GNU/Linux Operating Systems I Lab Ten Boot Process and GRUB. Boot Process and GRUB

AHA-1540C/1542C Installation Guide

Installation Guide AHA-1540CF/1542CF. High-Performance Bus Master ISA-to-SCSI Host Adapter with SCSISelect

RedHawk Linux Frequency-Based Scheduler User s Guide

StrongARM** SA-110/21285 Evaluation Board

SERVICE BULLETIN No. 24. For CAREpoint Workstation (Winsystems PC Modules Only)

T1/PRI and E1/PRI Cards

Colorful Technology Website:

Insert the D-Link CD-ROM Into Your Computer

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

Transcription:

MVCS Serial Communications Kernel Level Driver Installation Guide January 2006 0890509-100 READ READ READ ME ME ME BEFORE BEFORE BEFORE INSTALLING INSTALLING INSTALLING THIS THIS THIS PRODUCT PRODUCT PRODUCT

Disclaimer The information contained in this document is subject to change without notice. Concurrent Computer Corporation has taken efforts to remove errors from this document, however, Concurrent Computer Corporation s only liability regarding errors that may still exist is to correct said errors upon their being made known to Concurrent Computer Corporation. License Duplication of this manual without the written consent of Concurrent Computer Corporation is prohibited. Any copy of this manual reproduced with permission must include the Concurrent Computer Corporation copyright notice. Trademark Acknowledgments Night Hawk is a registered trademark of Concurrent Computer Corporation. PowerWorks, PowerMAX OS, and Power Hawk are trademarks of Concurrent Computer Corporation. Macrolink is a registered trademark of Macrolink, Inc. All other trademarks are the property of the respective owners. 2006 Concurrent Computer Corporation Al l Rights Reserved Concurrent Computer Corporation 2881 Gateway Drive Pompano Beach, FL 33069 Note: Information subject to change without notice.

Chapter 0Contents 1.0. Introduction........................................ 1 2.0. Documentation..................................... 1 2.1. Concurrent Documentation........................ 1 2.2. Vendor Documentation............................ 1 3.0. Prerequisites....................................... 2 3.1. Software........................................ 2 3.2. Hardware....................................... 2 4.0. Syntax Notation.................................... 2 5.0. Installation Procedures............................. 3 5.1. MVCS Kernel Driver Installation Procedures......... 3 5.1.1. Installation from 4mm DAT....................... 3 5.1.2. Installation from CD-ROM....................... 3 5.1.3. Configuring the Kernel Files...................... 4 5.1.4. Tuning the MVCS in the Kernel................... 6 5.2. MVCS Hardware Installation....................... 6 5.2.1. Board Configuration............................ 6 5.2.1.1 Address Switches......................... 6 5.2.1.2 MVCS Jumpers............................6 5.2.1.3 Installing the MVCS.........................7 6.0. Direct Software Support............................ 8 MVCS Serial Communications Kernel Level Driver Installation Guide iii

iv MVCS Serial Communications Kernel Level Driver Installation Guide

1.0. Introduction This document provides instructions for installing and configuring the MVCS Serial Communications Kernel Level Driver on NightHawk HN6200-HN6800, Power Hawk Series 600, and Power Hawk Series 700 Computer Systems running PowerMAX OS 5.1, and Power Hawk Series 700 and Power Hawk Series 900 Computer Systems running PowerMAX OS 6.3. The MVCS Serial Communications Controller is an advanced high-speed controller for VMEbus D32 applications. It provides 16 asynchronous serial ports and supports individual baud rates up to 115,200 baud. 2.0. Documentation 2.1. Concurrent Documentation The mvcs (7) man page is provided by Concurrent Computer Corporation with this product. 2.2. Vendor Documentation Vendor documentation for the Macrolink MVCS Serial Communications Controller may accompany this product. Contact the vendor if you have questions regarding this documentation. MVCS Serial Communications Kernel Level Driver Installation Guide 1

Prerequisites 3.0. Prerequisites The following prerequisites apply to the MVCS Serial Communications device. 3.1. Software PowerMAX OS Service Release 5.1SR6 or later. PowerMAX OS Service Release 6.3 or later. 3.2. Hardware NightHawk HN6200-HN6800 Computer System. Power Hawk Series 600 Computer System. Power Hawk Series 700 Computer System. Power Hawk Series 900 Computer System. Empty VME slot. 4.0. Syntax Notation The following notation is used throughout this manual: italic list bold list Books, reference cards, and items that the user must specify appear in italic type. Special terms may also appear in italics. User input appears in list bold type and must be entered exactly as shown. Names of directories, files, commands, options and system manual page references also appear in list bold type. Operating system and program output such as prompts and messages and listings of files and programs appear in list type. [ ] Brackets enclose command options and arguments that are optional. You do not type the brackets if you choose to specify such options or arguments 2 MVCS Serial Communications Kernel Level Driver Installation Guide

Installation Procedures 5.0. Installation Procedures 5.1. MVCS Kernel Driver Installation Procedures This section includes the following: Installing the MVCS driver package for PowerMAX OS from 4mm DAT. Installing the MVCS Driver package for PowerMAX OS from CD-ROM. Configuring the kernel files. Tuning the mvcs in the kernel. 5.1.1. Installation from 4mm DAT To install the MVCS Kernel Level Driver package (mvcs) from the 4mm DAT tape perform the following steps: 1. Boot the Concurrent Computer System to single-user mode. 2. Sign onto system as root. 3. If a version of the MVCS Kernel Level Driver already exists on this system, issue the pkgrm (1M) command and confirm to the command that the mvcs package is to be removed. (Note: this step can be followed to remove the driver regardless of whether a new version is to be installed.) Do the following step: 4. # pkgrm mvcs 5. Load the package tape into the 4mm DAT tape drive. 6. Install the software package on the system using the pkgadd (1M) command. When asked which package to install, select the mvcs package. 7. # pkgadd d tape1... Installation of MVC Sierra VME Serial Driver (mvcs) was successful. # 5.1.2. Installation from CD-ROM Note: The system must be configured with the gr (generic CD-ROM device driver) and cdfs (CD-ROM filesystem) modules and an entry must exist for the CD-ROM device nodes in /etc/conf/node.d/gr. To install the MVCS Kernel Level Driver package (mvcs) from the CD-ROM perform the following steps: 1. Boot the Concurrent Computer System to single-user mode. 2. Sign onto system as root. MVCS Serial Communications Kernel Level Driver Installation Guide 3

Installation Procedures 3. If a version of the MVCS Kernel Level Driver already exists on this system, issue the pkgrm (1M) command and confirm to the command that the mvcs package is to be removed. (Note: this step can be followed to remove the driver regardless of whether a new version is to be installed.) Do the following step: 4. # pkgrm mvcs 5. Insert the supplied disc into the CD-ROM drive and mount the file system as shown below: # mkdir /mnt/cdrom # mount F cdfs r /dev/cd /0 /mnt/cdrom 6. Install the software package on the system using the pkgadd (1M) command. When asked which package to install, select the mvcs package. # pkgadd d /mnt/cdrom/pkgs.dstream... Installation of MVC Sierra VME Serial Driver (mvcs) was successful. # 5.1.3. Configuring the Kernel Files The following steps are taken regardless of whether the software was installed from the 4mm DAT Tape or the CD-ROM: Note: The examples assume that only one mvcs is selected for installation and that it is adapter 0. 1. Edit the /etc/conf/sadapters.d/kernel file to ensure the entry for the MVCS board matches the physical address strapping of the board. Of particular importance is that the Bus Type should match the bus that the board is installed in and the I/O Addr 1 should match the address that the board is set to answer to. #Adapter Name Logical Adptr # Bus Type Intr Type Slot Number I/O Addr 1 I/O Addr 2 mvcs 0 vme0 intr - c1000000 0 4 MVCS Serial Communications Kernel Level Driver Installation Guide

Installation Procedures 2. Ensure the /etc/conf/node.d/mvcs file has the appropriate line for each mvcs un-commented as shown below: # Module Name type Adapter Adp# uid gid mode mvcs tty p:16 mvcs 0 0 3 0600 2 #mvcs tty p:16 mvcs 1 0 3 0600 2 #mvcs tty p:16 mvcs 2 0 3 0600 2 #mvcs tty p:16 mvcs 3 0 3 0600 2 level 3. If installation of the mvcs real-time driver was selected during the installation of the mvcs package, then ensure the /etc/conf/node.d/mvcsrt has the appropriate line for each mvcs uncommented as shown below: # Module Name type Adapter Adp# uid gid mode mvcsrt rtty p:16 mvcs 0 0 3 0600 2 #mvcsrt rtty p:16 mvcs 1 0 3 0600 2 #mvcsrt rtty p:16 mvcs 2 0 3 0600 2 #mvcsrt rtty p:16 mvcs 3 0 3 0600 2 level 4. Rebuild the kernel and reboot. # /etc/conf/bin/idbuild -B The PowerMAX OS kernel will be rebuilt now. This will take some time. Please wait. Root for this process is /. [...] The PowerMAX OS kernel has been rebuilt. The following command sequences reboot the system: # cd / # shutdown i6 g0 y (if boards are already installed) # shutdown i0 g0 y (if boards need to be installed) MVCS Serial Communications Kernel Level Driver Installation Guide 5

Installation Procedures 5.1.4. Tuning the MVCS in the Kernel Every port on each installed MVCS is separately tunable via the tunables identified in the /etc/conf/mtune.d/mvcs tunable file. One should use the config (1M) or the idtune (1M) utilities to modify the tunables associated with the installed MVCS boards. Some of the tunable parameters include: Defaults are shown in parentheses. Control Flag settings (CS8 CREAD CLOCAL HUPCL B9600) Input Flag settings (IXOFF IXON ISTRIP IGNPAR) Extended Flow Control settings (0x0) Receive FIFO Trigger Level (56) Board Interrupt Level (6) Board Oscillator Selection (0) 5.2. MVCS Hardware Installation This section includes the following: Configuring the switches and jumpers on the board. Installing the Model CE0948 MVCS in the Card Chassis 5.2.1. Board Configuration 5.2.1.1. Address Switches The base address of the MVCS is selected via rotary switches SW1 and SW2. SW1 is the most significant nibble of the board s address. These rotary dials are located near the Fail/Busy/Run indicator in the upper left corner of the board as seen with the component side towards you. For example, when the MVCS is located in A32 space and the switches are set to C1, the address of the MVCS will be 0xC1000000. The address dialed in should match the I/O address 1 identified in the /etc/conf/sadapters.d/kernel file. 5.2.1.2. MVCS Jumpers The MVCS has two user configuration jumpers. The remaining jumpers are set at the factory and must not be changed. 5.2.1.2.1 E3 Oscillator Select This jumper is located near the exact center of the board. When the jumper is installed at positions 2 & 3 (default), the UART clock source is the oscillator at location U25, with the frequency divided by two. When installed at positions 1 & 2, the UART clock source is the 14.7456 MHz auxiliary oscillator installed at location U30. The auxiliary oscillator frequency is not divided by two. 6 MVCS Serial Communications Kernel Level Driver Installation Guide

Installation Procedures 5.2.1.2.2 E4 Address Space Disable 5.2.1.3. Installing the MVCS These jumpers are located near the rear edge connectors at the center of the board. They are used to set the address space in which the MVCS is mapped. If both jumpers are removed, the board will appear in both the A24 and A32 address spaces. It is not recommended that you remove both jumpers unless it is required for your installation. If both jumpers are installed, the board will not appear in any VMEbus address space. A jumper installed from 1-2 will disable the A24 address space. A jumper installed from 3-4 will disable the A32 address space. The MVCS must be installed in a backplane that has both P1 and P2 connectors. The interrupt acknowledge (IACK IN/OUT) jumpers or switches must be removed or opened, as applicable, for the slot in which the MVCS is to be installed. Refer to the applicable Architecture Manual to determine the location of the IACK jumpers/switches. The Bus Request (BR3-0 In/Out) signals are automatically jumpered by the MVCS and the corresponding backplane jumpers/switches do not have to be removed or opened. Slide the board into the slot; ensure that it is fully seated into the backplane connectors. Tighten the lock down screws to secure the board and guarantee proper RF shielding. MVCS Serial Communications Kernel Level Driver Installation Guide 7

Direct Software Support 6.0. Direct Software Support Software support is available from a central source. If you need assistance or information about your system, please contact the Concurrent Software Support Center at our toll free number 1-800-245-6453. For calls outside the continental United States, the number is 1-954-283-1822. The Software Support Center operates Monday through Friday from 8 a.m. to 5 p.m., Eastern Standard Time. Calling the Software Support Center gives you immediate access to a broad range of skilled personnel and guarantees you a prompt response from the person most qualified to assist you. If you have a question requiring on-site assistance or consultation, the Software Support Center staff will arrange for a field analyst to return your call and schedule a visit. You may also submit a request for assistance at any time by using the Concurrent Computer Corporation web site at http:// www.ccur.com/isd_support_contact.asp or by sending an email to support@ccur.com. 8 MVCS Serial Communications Kernel Level Driver Installation Guide