About Data Collection Preferences. Before You Begin. Macintosh computer - Step One: Setting Folder Locations

Similar documents
During the calibration the following keys move the autosampler in the desired directions: Page Up. Hold SHIFT key together with the above key

Installing the GeneMapper Software and Creating a Matrix on the ABI PRISM 310 Genetic Analyzer

ABI PRISM GeneMapper Software Version 3.0 SNP Genotyping

User Bulletin. ABI PRISM 310 Genetic Analyzer. DRAFT February 6, :09 pm, A.fm. G5v2 Module for Use with Dye Set 33 (DS-33)

User Bulletin. GeneMapper Software Version 4.1. In This User Bulletin. Overview This user bulletin supplements the GeneMapper Software v4.

ABI PRISM 3100-Avant and 3100 Data Collection v2.0 Software Frequently Asked Questions (FAQ)

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A)

SequencePro Data Analysis Application. User Guide

GeneMapper Software v3.5

ABI PRISM 7700 Sequence Detection System: Routine Maintenance

Applied Biosystems TrueScience Aneuploidy STR Kits

User Bulletin. 3730/3730xl DNA Analyzer Data Collection Software. New features. SUBJECT: Data Collection Software version 3.1. In this user bulletin

User Bulletin. GeneMapper ID-X Software Version Update. GeneMapper ID-X Software Version Verification. In this user bulletin.

User Bulletin. ABI PRISM GeneScan Analysis Software for the Windows NT Operating System. Introduction DRAFT

User Bulletin Applied Biosystems StepOne /StepOnePlus Real-Time PCR System

Applied Biosystems SDS Plate Utility v2.2 For the ABI PRISM 7900HT Sequence Detection System

MicroSeq ID Analysis Software Version 1.0

Applied Biosystems DNA Sequencing Analysis Software Version 5.1 for Windows XP and 2000 Platforms. User Guide

GeneMapper ID-X Software

GeneMapper ID-X Software Version 1.2

Configuring GeneMapper ID Software

Analyzing a Project without a Reference

RELEASE NOTES TABLE OF CONTENTS SOFTWARE OVERVIEW

Next generation Confirmation (NGC) module

SynthAssist Software. User Guide. Version 3.1. DRAFT September 7, :02 pm, SynthA_Title.fm

FRAGMENT ANALYSIS USING ABI 3730/3730XL HANDBOOK. Fragment Analysis using ABI 3730/3730xL, 7-B406, version Devyser AB, 2018 Page 1 of 11

Veriti Thermal Cycler

User Bulletin. GeneMapper ID Software v3.2.1 Patch. In This User Bulletin. Obtaining and Installing the GeneMapper ID Software v3.2.

ABI PRISM 377 DNA Sequencer. SUBJECT: New Data Collection and Sequence Analysis Software Installation Guidelines and Fifth-Dye Sequencing

DIRECT INTERNET 3. Install Guide for the Mac OS Operating System

User Bulletin. Applied Biosystems StepOne Real-Time PCR System DRAFT. SUBJECT: StepOne System Updates. In This Bulletin Installation Updates...

Speedy Claims CMS 1500 Manual 2009 SpeedySoft USA, Inc.

ABI PRISM GeneMapper Software Version 3.0. User s Manual

READ ME FIRST Windows 98/ME/2000

Use the AccuSEQ Software v2.0 Custom Experiment mode

Applied Biosystems MicroSeq ID Analysis Software Version 2.0

HID Real-Time PCR Analysis Software

Release Date: September 4, 2014

GPS Explorer Software For Protein Identification Using the Applied Biosystems 4700 Proteomics Analyzer

User Manual Australia

SeqScape Software Version 2.7

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

Addendum SUPERSCRIPT 4400 SERIES USER S GUIDE. February, A

READ ME FIRST Windows 95/98/Me/2000

Quick-Start Guide READ ME FIRST. Installation Instructions for TROY Font Memory Card Kits

Installing and Using VeritiLink Software Quick Reference Card

CounterTrace. Users manual. Version 1.3.0

ChromQuest 4.2 Chromatography Data System

Applied Biosystems PCR System 9700, Firmware v3.12 Release Notes Contents:

FCWnx 7.7 Upgrade Manual

Workflow Guide Slide(s) Topic 2-6 Importing Data and Labeling Samples 7-11 Processing Data Without an Allelic Ladder Processing Data With an

DBT-120 Bluetooth USB Adapter

SymBiot I Sample Workstation

TI-SmartView Emulator Software for the TI-84 Plus Family (Windows and Macintosh )

RAZER FIREFLY MASTER GUIDE

Applied Biosystems AutoCaller Software

Paperless Office: Period End Processing LM-1020

FaxFinder Fax Servers

Reference Guide for the KODAK Picture Kiosk GS Compact. Software Version 2.0

Geneious Microsatellite Plugin. Biomatters Ltd

About Your Software IBM

Veritas Desktop Agent for Mac Getting Started Guide

Veritas Desktop and Laptop Option Mac Getting Started Guide

Procedure for GeneMapper ID. 1.0 Purpose To specify the steps for performing analysis on DNA samples using GeneMapper ID (GMID) software.

EcoStudy Software User Guide

MicroSEQ ID Analysis Software Version 2.2. Getting Started Guide

Devyser QF-PCR. Guide to Sample Runs, Data Analysis & Results Interpretation

[ Getting Started with Analyzer, Interactive Reports, and Dashboards ] ]

SomaticView Version 1.0

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

EFI Fiery Utilities Technical Reference. Part Number: , Rev. 1.0

Importing and processing AFLP sequencer curve files

SonicWall Global VPN Client Getting Started Guide

Applied Biosystems Variant Reporter Software

Dell OptiPlex All-in-One. Stand Installation Guide

FileMaker. Mobile 2. User s Guide. For Windows, Mac, and Palm OS. Companion for Palm OS

KYOCERA Net Viewer 5.3 User Guide

Universal Badge Format (UBF) for Picture Perfect User Manual

Forston Labs LabNavigator

Quantifying Motion in Three Dimensions with ProAnalyst

AccuRead Automate. Version 2.3. Administrator's Guide

ProNex DNA QC Assay Analysis Software

suitedxt Instructions for Use NeoSoft, LLC NS Rev. 2 Copyright 2014 NeoSoft, LLC All rights reserved

FileMaker. Mobile 2.1. User s Guide. For Windows, Mac, Palm OS, and Pocket PC. Companion for Palm OS and Pocket PC

Printer Settings. Accessing Power Saver. Selecting Output Options. Phaser 5500 Laser Printer

Importing and processing VNTR sequencer curve files

READ ME FIRST Windows 95/98/Me/2000

Contents. Introduction Panel Descriptions Saving Setting Values to the Computer As a File... 9

Secure Held Print Jobs. Administrator's Guide

Symantec Desktop and Laptop Option 8.0 SP2. Symantec Desktop Agent for Mac. Getting Started Guide

LTQ Velos SP3 Release Notes

for ColdFire Architectures V7.2 Quick Start

Avaya Call Management System Network Reporting

Océ User manual. Océ VarioPrint 1055/65/75. Configuration and maintenance manual

Variant Reporter Software

Océ User manual. Océ WPD Cleaning Tool Overview and usage

Printer Drivers Guide

Intel Entry Storage System SS4000-E

USB Memory Adapter MAUSB-500 REFERENCE MANUAL

Dell SonicWALL SonicOS 5.9 Upgrade Guide

Transcription:

To navigate within this document use the or keys ABI PRISM 310 Genetic Analyzer Data Collection Software Preferences Module Macintosh computer BEFORE PERFORMING ANY TROUBLESHOOTING WORK ON YOUR ABI PRISM 310 GENETIC ANALYZER, PLEASE READ THE INSTRUMENT USER S MANUAL FOR SAFETY AND WARRANTY INFORMATION AND FURTHER DETAILS ON USE OF THE SYSTEM. NOTE: Text in this fashion indicates a link to a picture or another section of this/another document. Please contact AB Technical Support if you have any questions regarding this procedure. About Data Collection Preferences The ABI PRISM 310 Genetic Analyzer is controlled by Data Collection software via a Macintosh or PC computer. The Data Collection software utilizes a series of preference settings to control the following aspects: Where the software looks for files How files are named Default settings for sample sheets and injection lists Computer/instrument communication ports File numbering On-screen dye representation Occasionally, these preferences may be inadvertently changed, deleted, corrupted, or otherwise compromised. A variety of preference-related problems may subsequently arise as a result. This document serves to inform users about the following topics: Step one setting folder locations What the preferences mean How to set preferences When to trash preferences How to trash preferences Before You Begin If you are unfamiliar with the regular preference settings for your system, please take some time to read this document in its entirety. As a safeguard, please record ALL your current settings, in case they need to be re-entered. Macintosh computer - Step One: Setting Folder Locations On the Macintosh version of 310 Data Collection, there are three scenarios that require the user to designate folder locations upon launching the software. Those three scenarios are: When the Data Collection software is launched after the initial install onto the computer. When the Data Collection software is launched after re-installation (presuming a clean uninstall was first performed where the program and the preference file have been deleted). When the preference file is physically deleted and then Collection is launched. In all situations, the user is prompted by a series of pop-up windows, to select the folder locations, for the software to function. Refer to the table below to set the proper folder locations.

Observation/Steps Action preference being set. In this case, the Sample Sheet folder will be set. 2) Use the drop-down menu to navigate to the Collection folder. 3) Click ONCE on the Sample Sheets folder in the main 4) Click ONCE on the Select Sample Sheets button to set the preference. Do not click OPEN. preference being set. In this case, the Module folder will be set. 2) If required, use the drop-down menu to navigate to the Collection folder. 3) Click ONCE on the Modules folder in the main 4) Click ONCE on the Select Modules button to set the preference. Do not click OPEN. being set. In this case, the Run folder will be set. 2) If required, use the drop-down menu to navigate to the Collection folder. 3) Click ONCE on the Runs folder in the main navigation window to highlight the folder, and update the Select button below. 4) Click ONCE on the Select Runs button to set the preference. Do not click OPEN. being set. In this case, the Firmware folder will be set. 2) If required, use the drop-down menu to navigate to the Collection folder. 3) Click ONCE on the Firmware Image folder in the main 4) Click ONCE on the Select Firmware Image button to set the preference. Do not click OPEN. being set. In this case, the Genescan Parameters folder will be set. 2) Use the drop-down menu to navigate to the Genescan Analysis folder. 3) Click ONCE on the GS Parameters Folder in the main 4) Click ONCE on the Select GS Parameters Folder button to set the preference. Do not click OPEN.

Observation/Steps Action being set. In this case, the Genescan Standards folder will be set. 2) If required, use the drop-down menu to navigate to the Genescan Analysis folder. 3) Click ONCE on the GS Standards Folder in the main 4) Click ONCE on the Select GS Standards Folder button to set the preference. Do not click OPEN. NOTE: For non-users of GeneScan software, set the GeneScan Parameters and the GeneScan Standards folder to: Macintosh Hard Drive > System Folder > ABI Folder. Macintosh computer- What the Preferences Mean There are eight individual preferences that can be configured for Data Collection software. Each preference consists of user-designated parameters. This table provides an overview of the preferences. Preference Folder Locations Default File Names Sequence Sample Sheet Defaults Sequence Injection List Defaults GeneScan Sample Sheet Defaults GeneScan Injection List Defaults General Settings Dye Indicators Configures the folders on the hard disk in which the following are stored: sample sheets, modules, runs, firmware, general settings, matrix files, analysis parameters, and size standard files. Configures the naming convention of various files generated by the Data Collection software. Configures the dye set/primer and matrix file used on a sequencing sample sheet. Configures the operator, length-to-detector, module, and automatic function parameters for sequencing runs. Configures the size standard color. Configures the operator, length-to-detector, module, automatic function, matrix, and size standard parameters for GeneScan runs. Configures the global serial number and communication port. Configures the displayed and printed colors.

Macintosh - How to Set Preferences Each of the eight individual preferences will be addressed in detail: Preference Folder Locations Default File Names The Folder Locations preference tells the software where to find the: Sample Sheet folder Module Folder Run Folder Firmware File Folder Analysis Settings Folder (NOTE: the Analysis Settings Folder is set to the ABI Folder) Genescan Analysis Parameters Folder Genescan Size Standard Folder The 7 pathways on the right identify the path to the folder. Most systems will be set-up with pathway endings similar to this screen. To set/change the path to a folder: 1) Click on the button/pathway that you want to change. 2) In the subsequent window, navigate to the location of the correct folder. 3) Select the correct folder, then click the Select button at the bottom of the window The Default File Names preference allows the user to designate specific names for the: Sample Sheet Run Folder Injection List Sample File NOTE: The text boxes (highlighted red) can be left as default, edited, or blanked out as desired. The drop down-menus allow a prefix/suffix to be attached. Do not use non-alphanumeric text as such characters can disrupt downstream processes. The selections in the drop-down menus include: None ~ No value will be entered Date ~ Computer date and time stamp Serial number ~ Instrument serial number (if entered in the ABI 310 Calibrations file) Global serial number ~ An identifier number which counts upward from a pre-determined value. Tube number ~ Well position on the sample tray Sample name ~ Name entered in the sample sheet

Preference Sequence Sample Sheet Defaults Sequence Injection List Defaults GeneScan Sample Sheet Defaults The Sequence Sample Sheet Defaults preference automatically fills in the following two selections on a sample sheet: Dye Set/Primer ~ Also known as a mobility file. This file corrects for mobility shifts caused by the dye molecule. Matrix ~ This file corrects for spectral overlap inherent in the dyes. NOTE: These settings should be for the most commonly used chemistry on this instrument. If more than one chemistry is used, you will need to manually override the sample sheet settings each time. The Sequence Injection List Defaults preference allows for automatic filling of a new injection list. The settings available include: Length-To-Detector ~ The real distance (in cm) between the end of the capillary and the capillary window. NOTE: This value is for record-keeping only. It has no bearing on the data or the instrument. Operator ~ Enter the name of the user. Module ~ Choose the default sequencing module that will automatically appear on a new injection list. Autoanalyze with ~ Check this box to enable autoanalysis. From the drop-down menu, select the Sequencing Analysis program. Auto Print ~ Check this box to have sample file data automatically printed after analysis. The GeneScan Sample Sheet Defaults preference designates the default dye color that will automatically be selected as the Size Standard color on a newly created Sample Sheet. From the drop-down list, select the appropriate color (represented by the letter of the color).

Preference GeneScan Injection List Defaults The GeneScan Injection List Defaults preference allows for automatic filling of a new injection list. The settings available include: Length-To-Detector ~ The real distance (in cm) between the end of the capillary and the capillary window. NOTE: This value is for record-keeping only. It has no bearing on the data or the instrument. Operator ~ Enter the name of the user. Module ~ Choose the default GeneScan run module that will automatically appear on a new injection list. Matrix ~ Choose the appropriate matrix that will correct for spectral overlap inherent in the dye set. Autoanalyze with ~ Check this box to enable autoanalysis. Form the drop-down menu, select the GeneScan Analysis program. Analysis Parameters file ~ Choose the appropriate analysis parameter file, which sets the start, stop, threshold, smoothing, and size-calling method. Size Standard file ~ Choose the appropriate size standard, which is a ladder of known fragments used to compare relative sizes of unknown samples under similar run conditions. Auto Print ~ Check this box to have sample file data automatically printed after analysis. General Settings The General Settings preference sets the communication port and automated file numbering. Communication is typically through the MODEM port. Select MODEM if the serial cable from the instrument is connected to the computer s MODEM port. However, the instrument can be configured to communicate through the PRINTER port, if so desired. The serial cable from the instrument must be connected to the computer s PRINTER port and the PRINTER port selected. If your computer utilizes a Keyspan Serial Card Adapter, you may need to reconfigure the PortConnector and/or KeySX Manager software. If you are using a Macintosh G3/G4 computer of the blue/white or grey/white configuration, you may need to reinstall the driver for the gport/g4port universal serial adapter. Refer to the appropriate user documentation. The Global Serial Number can be set in the text box.

Preference Dye Indicators The Dye Indicators preference allows the user to set the: Dye Code ~ Letter related to the dye s color or name. Type in the box to change the code. Dye Color ~ Color displayed on the screen to represent fluorescence from that dye. Click the dropdown menu to change the color. Plot Color ~ Color displayed on the electropherogram to represent fluorescence from that dye. Click the drop-down menu to change the color. Reset To Factory Settings ~ Click to revert all settings on this page to factory settings. Macintosh computer - When to Trash Preferences The preference file is involved in the following processes: Where the software looks for files How files are named Default settings for sample sheets and injection lists Computer/instrument communication ports File numbering On-screen dye representation Any compromise in these functions may be manifesting a preference-related problem. The most likely symptoms include (but are not limited to): Sample sheet does not show all selections Injection list does not show all selections Communication between the instrument and computer is unreliable Data does not get saved to designated locations File names are changed or altered Macintosh computer - How to Trash Preferences In cases where the preference file may be compromised, the user can trash the preference file, and recreate it. The preference file is located in the following directory: Macintosh Hard Drive > System Folder > Preferences Folder Drag the file entitled ABI 310 to the Trash and empty the trash. NOTE: Data Collection must not be running while this file is removed. Upon launching the Data Collection software, please refer to the section entitled Macintosh computer - Step One: Setting Folder Locations for more details.

Contacting AB Technical Support By Telephone: 1-800-831-6844 By Internet: http://www.appliedbiosystems.com/support/ Then click on Frequently Asked Questions and then the Ask a Question tab. By E-mail: ABTechnicalsupport@appliedbiosystems.com For Research Use Only. Not for use in diagnostic procedures. Notice to Purchaser: License Disclaimer Purchase of this software product alone does not imply any license under any process, instrument or other apparatus, system, composition, reagent or kit rights under patent claims owned or otherwise controlled by Applera Corporation, either expressly or by estoppel. Applied Biosystems, ABI PRISM, and GeneScan are registered trademarks and AB (Design) and Applera are trademarks of Applera Corporation or its subsidiaries in the US and/or certain other countries. All other trademarks are the sole property of their respective owners. PN 4375357 Rev A Stock No. 106GU26-01