SA2WEB24. Central unit module. Benefits. Description

Similar documents
SH2WEB24. Central unit module. Benefits. Description

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

smart-house Controller Central Unit Module Type SH2WEB24

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

B5X-LS4-U. Light switch. Benefits. Description

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

GS Dupline Profinet Gateway. Benefits. Description

Energy Management BUS Adapter Type VMU-B

Energy Management BUS Adapter Type VMU-B 01

VMU-C EM system. Integrated modular system to monitor conventional energy. Benefits. Description

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

EM271. Multi-channel power analyzer. Benefits. Description

EM270. Multi-channel power analyzer. Benefits. Description

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

WM20. Power analyzer for three-phase systems. Benefits. Description

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

PLC PFC200 Controller PFC200 CS 2ETH RS

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET

SBB4I2O230 ENG. Fire damper I/O Module. Benefits. Description

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

MIC-2 Multi-instrument DATA SHEET

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

COMTRAXX COM460IP. BMS-Ethernet-Gateway

BMS-Ethernet-Gateway COM460IP

General information. Display. Supply voltage

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

TM251MESC controller M251 Ethernet CAN

Energy Management Energy Transducer Type ET112

General information. Display. Supply voltage. Input current

Voltage Transducer UMT516 / MT516

MGate 5105-MB-EIP Series

General information. Display. Supply voltage

TM241CE24T controller M IO transistor PNP Ethernet

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TF501, TF521 Terminal Bases

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

May Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

Web-enabled DAQ System

TM241CE24U controller M IO transistor NPN Ethernet

General information. Display. Supply voltage

TM241CE40R controller M IO relay Ethernet

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

LBVR1718. Description. Features channel paperless recorder

TM241CEC24R controller M IO relay Ethernet CAN master

X-Log Expert Data Logger

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TU531, TU532 Terminal Unit

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

General information. Display. Supply voltage. Input current

Features and Benefits. Certifications

MGate 5102-PBM-PN Series

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

Features and Benefits. Certifications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CM597 Ethernet Communication Module

General information. Display. Supply voltage. Input current

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Web interface BACnet/IP

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

MODEL: GR8-EM. Communication Adaptor GR8 Series

SNMP Web Management. User s Manual

Power Meter PowerMonitor 500

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

General information. Display. Supply voltage. Input current

TM221M16R controller M IO relay

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TM251MESC controller M251 Ethernet CAN

TM200CE24T controller M IO transistor Source+ Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

General information. Display. Supply voltage. Input current. Encoder supply. Output current

UWP 3.0 HW manual rev. 0.7, 06/09/2018

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

Central unit module Benefits Configurable by software. Home and building automation functions and energy data logging are configurable by software. Spread sheets compatible. All data exports are compatible with Excel or other spread sheets. Modularity. The system is composed by modules so that each installation can be precisely and easily sized. Scalability. The system can be progressively integrated with new modules according to the application needs. Fast and easy installation. Completely free topology, no special cable required, no screen or twist. It can go for 2 km and even further with repeaters. Remote control. All functions can be remotely controlled while the owner is away and moreover a series of actions can be automatically performed. User-friendly. The system is user-friendly and really anyone can easily learn to master it. Description The is a programmable integrated unit specially designed for home and building automation applications. The controller includes dedicated functions for home automation such as light control (DALI), temperature control, roller blind control, alarm monitoring, energy monitoring, etc... The is as default configured without intelligent in- and output functions to run modules on the smart Dupline bus. In order to set up the intelligent functions, the has to be configured by the Windows based configuration software. This software is free downloadable from Carlo Gavazzi website. Applications Smart Dupline is a bus system that offers unique solutions for a wide range of applications in home and building automation, industrial automation, water distribution, energy management, railway systems and many other areas. 13/10/2017 DS ENG 1

Main features Micro PC with Web-server Linux embedded operating system One Ethernet port Two multi purpose USB 2.0 ports Data logging Internal data storage up to 30 years in a 4GB memory Structure Element Component Function A Ethernet port Displaying the web interface and transmitting data to remote systems via wired connection B USB Port (Host function) IP address programming C Information LED Indicating the following statuses: Local bus connection (BUS) Status (STATUS) USB key (USB) Module power D Micro SD memory card slot IP address programming E Mini-USB port (Device function) Connecting a PC to view the web interface if there are connection problems via Ethernet port and permitting backup to PC F Power terminals Powering the module G Local bus port Right side: connecting the SH2MCG24, SH2WBU230N, SH- 2DUG24 13/10/2017 DS ENG 2

Features General Material Dimensions Weight Protection grade Dielectric strength Rejection (CMRR) Terminal Noryl, self-extinguishing V-0 (UL94) 2-DIN module 150 g Front: IP40; Screw terminals: IP20 4000 VAC RMS for 1 minute >65 db, from 45 to 65 Hz 2 screw-type; Section: 1.5 mm 2 maximum; Torque Environmental Operating temperature Storage temperature Humidity (non-condensing) -20 to +50 C (-4 to 122 F) -30 to +70 C (-22 to +158 F) 20 to 90% RH Compatibility and conformity Electromagnetic compatibility (EMC) - immunity Electromagnetic compatibility (EMC) - emissions EN 61000-6-2 EN 61000-6-3 Approvals 13/10/2017 DS ENG 3

Power Supply Power Supply Overvoltage cat. II (IEC 60664-1, par. 4.3.3.2); Rated operational voltage: 15 to 24 VDC ± 20% Rated operational power 5 W Protection for reverse polarity Yes Connection A1 (+) and A2 (-) Inputs/outputs insulation Type of input/output DC power supply Ethernet USB port "H" USB port "D" DC power supply - 0.5 kv 0 kv 0 kv Ethernet 0.5 kv - 0.5 kv 0.5 kv USB port "H" 0 kv 0.5 kv - 0 kv USB port "D" 0 kv 0.5 kv 0 kv - 0kV: inputs / outputs are not insulated. 0.5kVrms: the insulation is functional type Mounting. Main hardware characteristics Memory Communication ports Auxiliary bus (HS BUS) USB ports Flash (data): 4 GB RAM 128 MB (internal) File system: external micro SD or USB memory stick only: FAT32 (VFAT). Up to 2 GB in case of micro SD type and from 4 to 16 GB in case of micro SDHC type (removable), industrial type (-25 C to 85 suggested) Ethernet: 1 port, for Internet/LAN connection Right side: compatible with SH2MCG24, SH2WBU230x and SH2DUG24 units 1, B device function 1, E host function HS Bus Bus type Function Number of slave Connection RS485 high speed bus Connection to master channel generator module (SH2MCG24, SH2WBU230x and SH- 2DUG24) Maximum 3: 1 x SH2MCG24 max 1 x SH2WBU230N max 1 x SH2DUG24 max 1 x SH2MCG24 + 1 x SH2WBU230N 1 x SH2MCG24 + 1 x SH2DUG24 1 x SH2DUG24 + 1 x SH2WBU230N 1 x SH2MCG24 + 1 x SH2DUG24 + 1 x SH2WBU230N By local bus on the right side Note: All the SH2MCG24, SH2WBU230x and SH2DUG24 modules have to be connected on the right side of the 13/10/2017 DS ENG 4

Main functions Configuration Clock Event management and messaging Logging Memory The configuration and the programming of and all other modules connected to either the same local bus can be carried out using the Sx configuration software. For the installation of the configuration, please refer to the Sx tool software manual. Functions: universal clock and calendar with automatic synchronisation enabling through internet connection. Battery life: 10 years. E-mails configuration: setting of recipient addresses and relevant subject, sender address, sender name, SMTP server, username of SMTP server and password of SMTP server. Actions: the user can program according to which events the emails and relevant attachments have to be sent. Data: the data are accessible and downloadable using Ethernet communication port. Function description: all the variables gathered from both Dupline modules and Modbus modules are stored individually into the internal memory. Stored data type: variables: V, A, W, kwh, temperatures, light levels, wind speed, humidity, in general all the analogue values collected from the smart Dupline modules. Storage interval: selectable from 1 minute to 24 hours. Sampling management: the sample stored within the selected time interval results from the continuous average calculation of the measured values. The average is calculated with an interval within two following measurements of approx. 2s. Storage duration: before overwriting: depending on the storage interval. Number of variables: see Stored set of variables. Data format: variables, date (dd:mm:yy) and time (hh:mm:ss). Events: the data are accessible and downloadable using Ethernet communication port: see Memory Management table. Function description: all the events gathered from the smart Dupline functions can be stored individually into the internal memory. Number of events: till memory is full. Data reset: the reset can be carried out through the proper command in the Sx tool. Data format: event, date (dd:mm:yy) and time (hh:mm:ss). Total available memory for database and events: 1.8 GB. Yearly grouped data: 6.0Mb. Single row: 150 bytes. Notes: When the 1.8 GB limit is reached, the 5% of the oldest data are deleted to provide the space for new data. The memory used data are relevant to the internal memory only. 13/10/2017 DS ENG 5

Ports Ethernet Rated inputs IP configuration DNS HTTP Static IP/Netmask/Default gateway, DHCP Primary and secondary DNS as a static or dynamic management (using DHCP server if configured). WEB server Port: 80; N. of connections: 3 TOOL N. of connections: 1 MODBUS TCP/IP N. of connections: 5 Connections RJ45 10/100 BaseTX; Max. distance: 100m Insulation See Insulation between inputs and outputs table USB Type High speed 2.0 Connections A type as Host function on the top of the housing. Mini A type as Device function on the front of the housing protected by front cover. Host function (USB) Available on the B USB port only. Available on the E USB port only, can be connected to a PC to perform the following functions: Device function (mini USB) service port for firmware upgrading. Note: both USB and mini USB ports are working in parallel, so relevant port functions can work simultaneously. Working type Hot swap Communication speed 60MB/s (480Mbits/s) Micro SD slot Type Capacity Function Industrial (from -25 to +85 C / -13 to + 185 F) SD: up to 2 GB SDHC: 4 16 GB IP address programming Mini-USB Type Mode Speed Function Condition of use High speed USB 2.0 - mini Hot swap 60 MB/s Accessing the web interface without Ethernet connection* Configuring the system, updating firmware, and downloading measured data and events Can be used in parallel with USB port. Note*: this requires a specific driver be installed in the PC. The driver is downloadable from Carlo Gavazzi website. 13/10/2017 DS ENG 6

Communication protocols Introduction The SA2WEB module collects data from the field, it processes collected data and communicates to remote systems. Different TCP/IP based communication protocols can be used. All protocols are supported by wired and wireless connection and managed on both local network (LAN) and remote one (WAN). Protocol overview Protocol Type Transmission mode from SA2WEB Data HTTP (web browser) Standard Pull All Modbus TCP/IP Standard Pull All Inbound TCP/IP communication TCP/IP port number TCP/IP port description Purpose 80/443 HTTP/HTTPS Access to the internal web-server 52325 SSH Remote service (reserved to support personnel) Outbound TCP/IP communication TCP/IP port number TCP/IP port description Purpose 23 DNS Domain name resolution 37 NTP Network time services access 25 (selectable) SMTP Email message dispatching Modbus TCP communication TCP/IP port number TCP/IP port description Purpose 502 (selectable) Modbus (TCP) Modbus TCP data communication: both master and slave Connection to the configuration tool TCP/IP port number 10000/10001/10002/80/48007/52325 Purpose Connection to the configuration software First connection: the SA2WEB is by default programmed as DHCP client. It has, anyway, a fixed secondary IP address: 192.168.253.254 13/10/2017 DS ENG 7

Connection Diagrams Fig. 1 Power supply References Further reading Information Document Where to find it SA2WEB installation guide System manual www.productselection.net/manuals/uk/system_manual.pdf SA2WEB software manual SA tool manual www.productselection.net/manuals/uk/sa_tool_manual.pdf SA2WEB wireless installation manual Wireless manual http://www.productselection.net/manuals/uk/wireless_manual.pdf Order code CARLO GAVAZZI compatible components Purpose Component name/code Notes Controller Bus generator SH2WBU230N, SH2MCG24, SH2DUG24 COPYRIGHT 2015 Content subject to change. Download the PDF: www.productselection.net 13/10/2017 DS ENG 8