RICi-16 Ethernet over Bonded PDH Network Termination Unit

Similar documents
RICi-16 Ethernet over Bonded PDH Network Termination Unit

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

ETX-102 Carrier Ethernet Demarcation Device

ETX-201A Carrier Ethernet Demarcation Device

Where to buy > Product page >

ASMi-54 SHDSL.bis Modem

ASMi-54L SHDSL.bis Modem

ASMi-54L. Data Sheet. SHDSL.bis Modem

Optimux-34, Optimux-25

FCD-E1E Managed E1 and Fractional E1 Access Device

ASMi-54 SHDSL.bis Modem

Optimux-1032, Optimux-1025

Optimux-108, Optimux-106

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

MARKET SEGMENTS AND APPLICATION

Optimux-34 Fiber Optic Multiplexer

ETX-204A Carrier Ethernet Demarcation Device

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

ETX-204A Carrier Ethernet Demarcation Device

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

Gmux Modular TDMoIP Gateway FEATURES

ETX-203AX Carrier Ethernet Demarcation Device

FCD-155 STM-1/OC-3 Terminal Multiplexer

2/4-wire SHDSL Modem/Multiplexer

ETX-204A Carrier Ethernet Demarcation Device

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Vmux-400 GSM A-bis/A-ter Optimization Gateway

FCD-155 STM-1/OC-3 Terminal Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

Multiservice Network Termination Unit

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

FCD-155 STM-1/OC-3 Terminal Multiplexer

IPmux-16 TDM Pseudowire Access Gateway

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

IPmux-1E TDM Pseudowire Access Gateway

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

IPmux-4LGE TDM Pseudowire Gateway

Vmux-210 Analog Voice Trunking Gateway

ETX-203A Carrier Ethernet Demarcation Device

Optimux-108, Optimux-106

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

IPmux-216 TDM Pseudowire Access Gateway

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

ETX-203A Carrier Ethernet Demarcation Device

ATM OVER PACKET CAPABILITIES

IPmux-24 TDM Pseudowire Access Gateway

FOMi-40 Fiber Optic Modem with Remote Management

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

Vmux-2120 Voice Trunking Gateway

ACE-3000 Family ACE-3100 Cell-Site Gateway

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

IPmux-14. TDM Pseudowire Access Gateway FEATURES

IPmux-216 TDM Pseudowire Access Gateway

ACE-3000 Family ACE-3105 Cell-Site Gateway. 2G, 3G and HSDPA cellular traffic over packet-switched networks (PSNs) and ATM, using DSL uplinks

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

Product page > Link-layer OAM according to IEEE 802.3ah is used for fault indication and loopback activation response.

SFP Transceivers Small Form-Factor Pluggable Transceivers

ACE-3000 Family ACE-3200 Cell-Site Gateway

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

ETX-203AM Universal Carrier Ethernet Demarcation Device

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

IPmux-1E. TDMoIP Gateway FEATURES

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

SFP Transceivers Small Form-Factor Pluggable Transceivers

ACE-3000 Family ACE-3400 Aggregation Site Gateway

Vmux-110 Voice Trunking Gateway for Remote Sites

BROAD RANGE OF INTERFACES

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

ACE-3000 Family ACE-3105 Mobile Backhauling Cell-Site Gateway

PSEUDOWIRE PERFORMANCE

Note: IPmux-155L equipped with the AC or 48 power supply modules supports up to 16 MiRICi-E3T3 units.

About RAD Data Communications. Carrier Ethernet Access

SFP/XFP Transceivers Small Form-Factor Pluggable Transceivers

Vmux-110. Voice Trunking Gateway FEATURES

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

Carrier Ethernet Access

IPmux-24 TDM Pseudowire Access Gateway

LA-140. Advanced ATM IAD FEATURES

Airmux-400, Airmux-5000 Optional Accessories

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux Accessories KM-Ringer, Ringer-2000, Ringer-2200N DC Feed and Ring Power Supplies for Voice/Fax and ISDN Modules

LA-110 Advanced Integrated Access Device

MARKET SEGMENTS AND TYPICAL

ISCOM RAX 711 (B) Ethernet Demarcation Device

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

ACE-3000 Family ACE-3220 Mobile Backhauling Cell-Site Gateway

Where to buy > Product page > (E1/T1, SHDSL, data or voice ports) into IP or MPLS packets for transmission over Ethernet, IP or MPLS networks.

modules in the MP-4100/4104 chassis (E1/T1, SHDSL, data or voice ports) into IP or MPLS packets for transmission over Ethernet, IP or MPLS networks.

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

4 E1-4 x 10/100 Ethernet converter with VLAN

Transcription:

Data Sheet RICi-16 Connects Fast Ethernet LANs transparently over TDM infrastructure Transports Ethernet traffic over 16 bonded E1 or T1 ports or two clear channel T3 ports using Ethernet over NG-PDH protocols MEF 9/MEF 14 certified product supporting EPL and EVPL services with flexible mapping of user traffic into Ethernet flows Enhanced QoS mechanism and flow-based provisioning (service multiplexing) with advanced traffic management Monitoring and diagnostic tools for quick fault isolation on TDM and Ethernet ports Complete Ethernet OAM solution based on IEEE 802.3-2005 (formerly 802.3ah), IEEE 802.1ag and ITU-T Y.1731 RICi-16 is a state-of-the-art Network Termination Unit (NTU) connecting Fast Ethernet LANs over up to 16 bonded E1/T1 lines or up to two clear-channel T3 circuits. Alternatively, RICi-16 can transport Ethernet over bonded and TDM T1s using a single channelized T3 as uplink. This enables service providers to supply high-capacity Ethernet services to remote locations, and transparently connects corporate LANs over existing PDH infrastructure. An essential part of RAD s EtherAccess TM portfolio, RICi-16 features Carrier Ethernet attributes, that include Ethernet OAM for proactive SLA monitoring, quality of service (QoS) per Ethernet flow and advanced traffic management capabilities, all starting at the service hand-off points. MEF COMPLIANCE Certified by the Metro Ethernet Forum (MEF) for the following services: MEF 9: EPL, EVPL MEF 14: EPL, EVPL. The Access Company

RICi-16 ENCAPSULATION AND BONDING RICi-16 uses the Ethernet over NG-PDH technologies such as Generic Framing Procedure (GFP G.8040), Virtual Concatenation (VCAT G.7043) and Link Capacity Adjustment Scheme (VCAT G.7042). NG-PDH solutions improve overall network availability by reducing latency and optimizing line utilization and throughput. The unit supports up to 16 GFP VCAT groups (VCG), allowing the connection of up to 16 different customers per site. Typical applications include: IP DSLAM, cellular IP, and WiMAX base station backhauling Interoffice or enterprise LAN connection. FLEXIBLE TRAFFIC MAPPING Traffic is mapped to the Ethernet flows (EVCs) using the following per-port criteria: Port-based (All-to-one bundling) CE-VLAN CE-VLAN priority DSCP IP precedence CE-VLAN + CE-VLAN priority CE-VLAN ID + IP precedence (user to network only) CE-VLAN + DSCP (user to network only) Non-IP CE-VLAN + non-ip Untagged. TRAFFIC SEPARATION VLAN stacking and stripping option at ingress and egress enables transporting user traffic transparently, keeping the user VLAN settings intact. In addition, the management traffic can be tagged with a different VLAN, fully separating user traffic from management data. QUALITY OF SERVICE QOS Different service types require different levels of QoS to be provided end-to-end. QoS can be defined per subscriber as well as per service. QoS has two aspects: rate limitation and traffic prioritization. Two policing mechanisms are applied per flow. The policing mechanisms operate according to the dual leaky bucket mechanism (CIR + CBS, EIR + EBS: two rates, three colors). For prioritizing user traffic, RICi-16 employs up to four separate queues. The queues handle traffic with different service demands, such as real-time traffic, premium data, or best-effort data. MANAGEMENT Remote inband management via the network ports using Telnet, Web browser or RADview, RAD s SNMP based management system. Out-of-band management via one of the user data ports that can be configured as a management port Local management via an ASCII terminal connected to the RS-232. Figure 1. Ethernet Cellular Backhauling over PDH/SONET/SDH

SIMPLE NETWORK TIME PROTOCOL RICi-16 uses Simple Network Time Protocol (SNTP) to synchronize to an accurate time from an NTP server at user-selectable intervals. L2CP HANDLING RICi-16 can be configured to pass through Layer-2 control frames across the network, to peer-supported protocols (OAM.ah), or to discard the L2CP frames. SECURITY To provide a high level of client-server communication security, the following security protocols are supported: SNMPv3 RADIUS authentication SSL for Web-based management SSH for Secure Shell communication. FAULT PROPAGATION The unit features a user-configurable bidirectional fault propagation mechanism that notifies local and remote equipment of faulty conditions. This enables routers and switches on both ends of the link to reroute traffic. ETHERNET OAM Two types of Ethernet OAM are provided: Single segment (link) OAM according to IEEE 802.3-2005 (formally 802.3ah) for remote management and fault indication OAM Connectivity Fault Management (CFM) based on IEEE 802.1ag and ITU-T Y.1731 enables Ethernet service providers to monitor their services proactively, measure end-to-end performance, and guarantee that customers receive the contracted SLA. Figure 2 Ethernet Services over PDH/SONET/SDH Using Egate-100 Figure 3. Next-Generation Mobile Connectivity over PDH Microwave Links

RICi-16 Data Sheet Specifications E1 INTERFACE 4, 8, or 16 Compliance G.703 G.704 2.048 Mbps Line Code HDB3, AMI Framing Framed (G732N with CRC) Line Impedance 120Ω, balanced 75Ω, unbalanced (via adapter cable) RJ-45, balanced System Clock Internal or loopback timing T1 INTERFACE 4, 8, or 16 Compliance T1.403 1.544 Mbps Line Code B8ZS, AMI Framing ESF Line Impedance 100Ω, balanced System Clock Internal or loopback timing RJ-45 T3 INTERFACE 1 (channelized) 2 (clear channel) Compliance T1.102, T1.107 44.736 Mbps Line Code B3ZS Framing M23 or C-bit parity Line Impedance 75Ω, unbalanced System Clock Internal or loopback timing BNC WAN PROTOCOL Encapsulation GFP (G.7041) GFPoPDH (G.8040) Bonding VCAT (G.7043) Up to 16 VCAT groups LCAS (G.7042) Delay Compensation Up to 250 ms (E1/T1 ports) Up to 217 ms (clear channel T3 ports) ETHERNET INTERFACE Standard Compliance IEEE 802.3 and 802.3u, relevant sections 3 or 4 Type 10/100 Mbps, autonegotiation, full/half duplex, flow control Port Combinations 4 built-in electrical 2 built-in electrical + 1 fiber optic SFP (for transceivers, see Ordering) Max Frame Size 1700 bytes SFP Transceivers For full details, see the SFP Transceivers data sheet at http://www.rad.com Note: It is strongly recommended to order this device with original RAD SFPs installed. This will ensure that prior to shipping. RAD has performed comprehensive functionality quality tests on the entire assembled unit, including the SFP devices. RAD cannot guarantee full compliance to product specifications for units using non-rad SFPs. For detailed specifications of the SFP transceivers, see the SFP transceivers, see the SFP Transceivers data sheet. Figure 4. Ethernet Services over PDH/SONET/SDH Using RICi-16 as Aggregator

INTERNAL BRIDGE GENERAL LAN Table Up to 2018 MAC addresses (learned) and 30 static addresses Diagnostics Remote loopbacks on E1, T1, T3 interfaces Operation Mode VLAN-aware, VLAN-unaware Filtering and Forwarding Transparent or filtered Indicators PWR (green, per power supply) Power status TST (yellow) Self test status ALM (red) Alarm status Type RS-232/V.24 (DCE asynchronous) Power Wide-range AC/DC: 100 240 VAC, 50/60 Hz or 48/60 VDC nominal (40 72 VDC) 9.6, 19.2, 115.2 kbps Power Consumption 13W max TERMINAL CONTROL PORT Physical Height: 43.7 mm (1.7 in) 1U Width: 440.0 mm (17.3 in) Depth: 240.0 mm (9.4 in) Weight: 3.0 kg (6.6 lb) Environment Temperature: Standard enclosure: 0 to 50 C (32 to 122 F) Temperature-hardened enclosure: -22 to 65 C (-7.6 to 149 F) Humidity: Up to 90%, non condensing 9-pin, D-type, female RICi Family Product Comparison Table RICi-4E1, RICi-4T1 RICi-8E1, RICi-8T1 (Ver. 2.0) MLPPP (BCP) RICi-16 (Ver. 2.5) Feature RICi-E1, RICi-T1 (Ver. 2.1) RICi-E3, RICi-T3 (Ver. 1.1) Protocol Type RAD HDLC HDLC IS GFP (G.8040, G.7041/Y.1303) RAD HDLC X.86 (LAPS) Fault Propagation MAC Address Table GFP (G.7041), GFPoPDH (G.8040) VCAT (G.7043) LCAS (G.7042) 512 512 2048 2048 QoS VLAN Priority (802.1p) IP Precedence VLAN Priority (802.1p) VLAN Priority (802.1p) DSCP Per port VLAN Priority (802.1p) IP Precedence DSCP Per port QoS Mechanism Host VLAN VLAN Stacking

RICi-16 Data Sheet Ordering RICi-16/B/*/#/!/ /$/? RICi-16T3/!/ /? Note: If RICi-16T3 is ordered, the unit is supplied with 2 T3 ports (no T1 ports) and 4 Ethernet ports (unless SFP is ordered). Legend B Number of PDH ports: 16E1 16 E1 ports 16T1 16 T1 ports 8E1 8 E1 ports 8T1 8T1 ports 4E1 4 E1 ports 4T1 4 T1 ports 2T3 2 T3 ports Note: When RICi-16 is ordered with 16 E1/T1 or 2T3, the device is supplied with 16 E1/T1 ports, out of which only four ports are activated by default. Additional E1/T1 ports can be activated using a software license. For 4-E1/T1 and 8-E1/T1 versions, the device is supplied with all PDH ports operational. * License pack for PDH link activation: Pack 1 8 E1/T1 links Pack 2 12 E1/T1 links Pack 3 16 E1/T1 links Note: Applicable only for units 16 E1/T1 and 2 T3 ports. # Operation mode (Default=bridge mode): EVPL Enable Ethernet Virtual Private Line services using Ethernet flows! Ethernet SFP port (Default=4 Ethernet UTP ports) NULL SFP-ready slot SFP-1 Fast Ethernet/STM-1, 1310 nm, multimode, LED, 2 km (1.2 mi) SFP-2 Fast Ethernet/STM-1, 1310 nm, single mode, laser, 15 km (9.3 mi) SFP-3 Fast Ethernet/STM-1, 1310 nm, single mode, laser, 40 km (24.8 mi) SFP-4 Fast Ethernet/STM-1, 1550 nm, single mode, laser, 80 km (49.7 mi) SFP-9F Fast Ethernet, RJ-45 connector, 100m (238 ft) SFP-10A Fast Ethernet/STM-1, Tx 1310 nm, Rx 1550 nm, single mode (single fiber), laser (WDM), 20 km (12.4 mi) SFP-10B Fast Ethernet/STM-1, Tx 1550 nm, Rx 1310 nm, single mode (single fiber), laser (WDM), 20 km (12.4 mi) Note: When SFP is ordered, the device is supplied with a single SFP port and 2 Ethernet UTP ports. Number of power supplies (Default=single power supply): R Dual power supply $ E1 Interface type (Default=balanced): U Unbalanced E1 interface via RJ-45 to BNC adapter cable? Temperature range (Default=normal temperature range, not NEBS compliant): H Temperature-hardened, compliant with NEBS level 3, types 2, 3, and 4 LICENSE PACKAGES Software packages for activating additional operation modes and E1/T1 ports Legend RICi-16-EVPL Ethernet Virtual Private Line services using Ethernet flows RICi-16-Pack 1 8 E1/T1 links RICi-16-Pack 2 12 E1/T1 links RICi-16-Pack 3 16 E1/T1 links SUPPLIED ACCESSORIES AC power cord DC power connection kit CBL-RJ45/2BNC/E1 RJ-45 to BNC adapter cable (if unbalanced E1 interface is ordered) OPTIONAL ACCESSORIES CBL-DB9F-DB9M-STR Control port cable RM-34 Hardware kit for mounting one RICi-16 unit in a 19-inch rack WM-34 Hardware kit for mounting one RICi-16 unit on a wall RICi-16-PS Spare wide-range power supply module (100 240 VAC/ 48 VDC) 506-100-09/09 Specifications are subject to change without prior notice. 1988 2009 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@rad.com www.rad.com Order this publication by Catalog No. 803772 The Access Company