Chloride CROSS Rack 16 A, 32 A and 63 A

Similar documents
Liebert NX from 30 to 60 kw. AC Power for Business-Critical Continuity

Liebert Load Bus Sync Extender/Adapter for Dual Bus UPS

Chloride Trinergy from 200 to 1200 kw

Liebert IntelliSlot Relay Card

Liebert APM. The Compact Row-Based UPS With FlexPower Technology TM. AC Power for Business-Critical Continuity

SERIES 610 LOAD BUS SYNC

Liebert MicroPOD 230V

GXT 2U Configuration Program

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Liebert Precision Power Center

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Liebert Nfinity. A Powerful UPS Solution For Small To Medium Data Centers. AC Power For Business-Critical Continuity

Liebert NXC from 10 to 200 kva

Liebert APM. The Compact Row-Based UPS With Flexpower Technology TM. AC Power for Business-Critical Continuity

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

THE NEW SHAPE OF NETWORK POWER PROTECTION

Liebert NX. UPS For Small And Medium Business. AC Power For Business-Critical Continuity

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Liebert Maintenance Bypass Cabinet

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert NXr Series 15KVA to 90KVA (208V/220V) AC Power for Business-Critical Continuity

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

Liebert LM Series. Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

Liebert 80-eXL from 160 to 500 kw. Enhanced Design and Improved Efficiency

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Liebert THE NEW SHAPE OF NETWORK POWER PROTECTION. UPStation GXT 2U. An On-Line UPS With Proven Reliability,

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

MONITORING INTELLIRACK USER MANUAL

POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

RT4F-120V/20A-WAC RECTIFIER

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

RT4B-110V/12A RECTIFIER

Product Specifications

Liebert HPM from 4 kw to 100 kw

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Series 230 Automatic Transfer Switch

Tel: AC Power for Business-Critical Continuity TM

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Liebert : The Right Cooling For IT Environments

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Critical Power 2017 Catalogue

the Centric 300 An advanced modular UPS up to 1800kVA/kW

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

RT4F-110V/25A RECTIFIER

ATV1200A kv kva

ATV1200A kv kva

Section 4 Ground-Fault Protection Devices

Managed Rack PDU MPH2 More efficient Simpler Better

Liebert PDX from 15 to 120 kw

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

SMARTONLINE E3 UPS SYSTEMS

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

SLI 15 INVERTER SERIES, 1500 W

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Rack & Enclosure Systems

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

The Power of Modularity

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

Zenith Series STS-3 Static Transfer Switches

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

ALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

MGE Galaxy /900 kva

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

ARCHIMOD HE 240/480 HIGH POWER MODULAR UPS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

TME Modular Series UPS System kva/kw - 208/220 VAC

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Series 230 Automatic Transfer Switch

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

RT12-240V/2.4kW Rectifier Specification

Transcription:

AC Power for Business-Critical Continuity Chloride CROSS Rack 16 A, 32 A and 63 A STS Catalogue

Chloride CROSS Rack High Voltage and Low Voltage 2 Pole Complete Reliability On-line Static Switch 16 A, 32 A and 63 A Scope 4 System Control 5 Protection Devices and Control Functions 6 Monitoring, Control and Communication 7 Installation Requirements 8 Technical Data 9 3

1 Scope This specification describes the Chloride CROSS Rack series of single-phase, two-pole static switches with manual maintenance bypass switch, together with information regarding the products' electrical and mechanical features. Chloride CROSS Rack is optimized for installation in 19 standard rack cabinets; the vertical rack space occupation is 2 U for all models and the protection degree is IP20 (i.e. no openings are present on the top or bottom of the Chloride CROSS Rack enclosure). The air cooling is frontto-back and is obtained using fully redundant monitored fans. All of these features make Chloride CROSS Rack the ideal solution for racklevel power protection in modern data centers, ensuring maximum reliability to critical loads by eliminating system failures caused by issues in distribution rather than by the failure of the power source itself. 1.1 The system Chloride CROSS Rack ensures redundant power to critical loads through the ability to switch between two alternative singlephase power sources. Switching will occur whenever the line supplying the load no longer falls within the acceptable tolerance values. Chloride CROSS Rack operates in Fixed Priority Mode, in which the the user selects the preferred input line, allowing the Chloride CROSS Rack to transfer to the priority line whenever its parameters fall within acceptable values. Chloride CROSS Rack will function so that the transfer between the two sources will be break-before-make (BBM) on both poles, thus ensuring that the two sources will never be directly connected. Chloride CROSS Rack will ensure switching between independent AC power sources in both synchronous and asynchronous conditions. When the two lines are synchronous, Chloride CROSS Rack will transfer between the sources within a maximum of 6 ms following a line failure. In asynchronous conditions transfer will occur as described in section 2.2.1. The acceptable phase angle difference between the two lines for asynchronous transfers will be within a 15 range and selectable by the user. In order to maximize reliability, Chloride CROSS Rack s control logic will be redundant and minimize the use of common components. Chloride CROSS Rack will rely on front to back, forced and fully redundant cooling. 1.2 Models available Chloride CROSS Rack includes models with single-phase input and single-phase output, available in two versions the High Voltage model (HV) referring to a nominal voltage of 230 V and the Low Voltage model (LV) referring to a nominal voltage of 120 V, as specified below in Table 1. MODEL Current (A) Input Output Chloride CROSS Rack HV 16 16 Single-phase Single-phase Chloride CROSS Rack HV 32 32 Single-phase Single-phase Chloride CROSS Rack HV 63 63 Single-phase Single-phase Chloride CROSS Rack LV 16 16 Single-phase Single-phase Chloride CROSS Rack LV 32 32 Single-phase Single-phase Chloride CROSS Rack LV 63 63 Single-phase Single-phase Table 1. Chloride CROSS Rack Models Nominal currents are intended as continuous and may apply to any type of linear and non linear load (maximum crest factor 3:1) 4

2 System Control The advanced control logic of Chloride CROSS Rack provides the highest safety for the load through a break-before-make switching in any mode of operation. All of the power supplies and Silicon Controlled Rectifier (SCR) firing circuits are completely redundant. The coloured LED on the front panel of the Chloride CROSS Rack shall provide a simple and immediate indication of the operational state of the system. For a more detailed and complete description of diagnostics, see section 4.2. 2.1 Mode of operation The Chloride CROSS Rack will attribute a priority to one of the two sources. The priority source will be selected from the front panel by pressing push-button P. The selected source will be indicated by the corresponding LED (S1 or S2). The selected priority source will continuously supply the load provided it remains within the tolerance windows. Failure of the priority source will initiate transfer of the load to the reserve (low priority) source. When the priority line returns within the acceptable tolerance window, the load will automatically be transferred back to the priority line following a brief re-transfer time. In the event of both sources falling outside the acceptable tolerance windows, Chloride CROSS Rack can be programmed according to the desired behavior (remain on source1, remain on source2, open both static switches). 2.2 Transfer modes The Chloride CROSS Rack will perform a break-before-make switching under any condition. Operating modes are described as follows: 2.2.1 Line failure transfer Switching occurs if the characteristic parameters of the active power source (preferred or alternative) supplying the load fall outside defined limits. The parameters tested are the root mean square (RMS) and instantaneous values of the voltage, which must remain within a defined acceptance window. Once the parameters of the power source have returned to normal, if the load is supplied by the source selected as the alternative, it is automatically transferred back to the priority source (see also 2.2.2). Where switching occurs while sources are asynchronous, it is possible to choose between transferring in the shortest period possible (6ms), as if the sources were synchronous, or introducing an additional delay (selectable between 0 and 20ms) to the normal transfer time (default condition). 2.2.2 Transfer due to re-transfer of load to priority source In conditions where the priority source is not the one supplying the load (switching due to source fault condition or change of priority via push-button P), the Chloride CROSS Rack will automatically transfer the load to the priority source as soon as possible. Specifically, automatic switching to the priority source will occur only when the parameters of this last are within acceptable limits and when synchronization is established. If the priority source is out of limits, transfer will be effected only after it has remained stable and within limits for a preset period (5 seconds). In the case of loss of synchronization, transfer will only take place when the phase difference between the two sources is less than a preset value (10 by default). In any event, such switching occurs only when both sources are within tolerance and synchronized (transfer is also effected during the zero current crossing control in optimum conditions). All settings and operating modes of the Chloride CROSS Rack can be easily modified or enabled by trained customer engineers. 2.3 Operation under output short circuit The Chloride CROSS Rack will inhibit transfer whenever an output short circuit is detected, thus avoiding the transfer of the short circuit to the alternative source. The instantaneous short circuit threshold level is 3In. Only when the current falls below the threshold value and the voltage value is acceptable, does the Chloride CROSS Rack automatically reset and enable transfer. The Chloride CROSS Rack s internal logic will inhibit transfers even if an upstream protection device trips and the current goes to zero. 2.4 Operation under overload The Chloride CROSS Rack will be able to sustain the following overload conditions: 125% 10 min. 150% 1 min. 700% 0.6 sec. 5

3 Protection Devices and Control Functions 2.5 Maintenance bypass and Hot-Swap module The Chloride CROSS Rack is equipped with bypass switches, which allows complete maintenance while ensuring continuous power to the critical output load. Both of the input sources can be used during the maintenance bypass operations. The switching devices ensure that the direct connection of the two sources is never possible, even in the event of an error in user operation. The control logic will ensure that, in the event of an accidental closure of the bypass on the passive line, the Chloride CROSS Rack will transfer the load so as to avoid a permanent paralleling of the two sources, regardless of the operating modes described above. Furthermore, to ensure maintenance time is kept at a minimum (optimized <1 minute mean-time-to-repair with another CROSS Rack available as spare), the entire static module (logic and solid state power devices) can be extracted without interrupting the supply (hot-swap maintenance) after having switched the unit to manual bypass as described above. Refer to the User Manual for the detailed description of the hot-swap module maintenance. Devices to protect cables and loads must to be installed upstream and downstream of the equipment. These devices can be automatic switches, or fuses and switches, selected in conformity with the Chloride CROSS Rack current rating, the overload performance, the internal fuses described in section 3.1 and the downstream protections and loads. 3.1 Internal fuses The Chloride CROSS Rack will be supplied with fuses on the input phase of each source (660 Vac, 100 A; pre-arching I 2 T=2050 A 2 s, total I 2 T @ 230 V = 3740 A 2 s). These fuses have the sole function of protecting the subsystem and devices inside the unit itself from permanent output short circuit. Downstream protection devices will therefore have to be correctly dimensioned and coordinated. 3.2 Backfeed protection control This feature prevents even the most remote possibility of electric shock hazards on the alternative Chloride CROSS Rack mains supply terminal (the source that is not currently supplying the load) in the event of a static switch SCR failure (SCR shorted). The user interface includes two normally-closed voltage-free contacts. These are used to activate an external isolating device (electromechanical relays or minimum voltage tripping relays can be used) when backfeed is detected. The two external isolating devices are not included with the Chloride CROSS Rack (in conformity with Standards), and must be 2 pole, air-gap isolator devices as defined by IEC/EN 62310-1 (4.2.1.4). 3.3 Silicon Controlled Rectifier (SCR) open detector The Chloride CROSS Rack will also be able to diagnose the fault condition Open Circuit SCR on the active line. This fault condition will result in a transfer to the passive line and inhibit further transfers. 3.4 Redundant cooling The Chloride CROSS Rack is equipped with two fully redundant cooling fans. This feature allows extremely reliable front-to-back ventilation. Each fan is provided with a sensor which is able to detect the failure, which is then immediately communicated to the user. 6

4 Monitoring, Control and Communication 4.1 General The Chloride CROSS Rack will incorporate the necessary controls, instruments and indicators to allow the operator to monitor the system status and performance, as well as to take appropriate action. 4.2 Control signals The Chloride CROSS Rack is fitted with a control panel on the front of the unit. This includes a mimic panel and LED lights to indicate the operating status of the unit in realtime. The status of the sources, the static switches, the bypass, the load condition and the maximum operating temperature are all monitored continuously. The functions of the LED are described in section 4.3. On the control panel a push-button is also present which allows the user to set the priority between the sources and a LED which indicates the current priority. - If there is a loss of synchronization between the sources - If the Bypass switch is closed - If the system is in Over temperature - If there is an Output short circuit - If there is a general SCR fault - If there is a blocked fan - If the EPO is active - If the Backfeed Detector is active LED 6 & 7 - Bypass Switch Status Indicators LED ON = Bypass Switch CLOSED LED OFF = Bypass Switch OPEN LED 8 & 9 - Source S1 and S2 Status Indicators LED ON = Source OK LED OFF = Source OUT OF TOLERANCE LED 10 - Loss of Synchronization Indicator LED ON = Sources NOT SYNCHRONIZED LED OFF = Sources SYNCHRONIZED LED 11 & 12 - Static Switch Status Indicator LED ON = Static Switch CLOSED LED OFF = Static Switch OPEN LED 13 - Output Alarm LED13 ON = Switching Inhibited due to Output short circuit and/or Silicon Controlled Rectifier (SCR) open fault 4.4 Control panel Priority selection push-button Press to select system S1 S2 priority Source S1 or S2 P Refer to section 2.1 for more information about the operation of Chloride CROSS Rack during Priority Selection Reset push-button Press to reset permanent block (see Silicon R Controlled Rectifier (SCR) Open Fault Alarm) Note: The Reset command is accepted only if both sources are within the tolerances and they are synchronized. 4.3 Mimic LED display The controls are located on the front panel (see Figure 1). LED 1 & 2 - Priority Source Indicator LED 1 ON and LED 2 OFF = Priority on S1 LED 1 OFF and LED 2 ON = Priority on S2 LED 4 Summary Alarm This LED is illuminated under the following alarm conditions: - If at least one source is out of tolerance S1 S2 Figure 1. A view of the display and control panel 7

4.5 Output user signals A summary alarm contact is available as a cable screw terminal connector, interfaced with a voltage free relay contact (NO/NC 1A 220Vac). The summary alarm is activated under the conditions described in section 4.3. for LED 4. Chloride CROSS Rack is also equipped with a full set of digital optically isolated output contacts. These contacts can be accessed from the rear panel of the unit on a 25-pin socket. Digital Output list: Summary Alarm Priority on S1 / S2 Output Short Circuit SCR-Open Fault System Over-temperature Bypass S1 Closed Bypass S2 Closed EPO Active S1 Out Of Tolerance S2 Out Of Tolerance Sources Synchronized S1 Static Switch Open/Closed S2 Static Switch Open/Closed Backfeed detector active S1 Backfeed detector active S2 Fan failure Digital outputs are optoisolated signals (phototransistors); the power supply has to be provided externally (maximum current 3mA, maximum DC voltage +15V). 4.6 Input user signals Emergency power Off (EPO). When the EPO is activated, all the static switches are opened. 5 Installation Requirements For detailed installation requirements please refer to the User Manual. No additional space is required below or above the Chloride CROSS Rack, and no openings are present on the top or bottom of the Chloride CROSS Rack enclosure. 8

6 Technical Data STS Unit 16 A 32 A 63 A 6.1 Nominal Voltage (selectable) - HV model (V) 230 (220/240) Nominal Voltage (selectable) - LV Model (V) 120 (110/115) Input voltage acceptance window (tolerance ±2) (%) ±12 Input phases Single phase (Ph + N) Number of switching poles 2 (Ph + N) Nominal frequency (Hz) 50/60 ±10% (1) Nominal Current (A) 16 32 63 Input power ports 2 Output power ports 1 Efficiency at Nominal Power (%) 99 Overload capacity For 10 minutes For 1 minute For 0.6 seconds SCR Characteristics I 2 T @ Tvj = 125 C I TSM @ Tvj = 125 C Fuses Pre-arching I 2 T Total I 2 T @ 230V (%) (%) (%) (A 2 s) (A) (A 2 s) (A 2 s) 125 150 700 15000 1750 660 Vac, 100A fast 2050 3740 Temperature range ( C) 0-40 Synchronization range Cooling Transfer Mode Transfer Time -Worst condition zero voltage source failure -Typical zero voltage source failure Additional transfer delay time for non-synchronous transitions (ms) (ms) (ms) 10 (5-15 selectable) Front to back, Forced, Fully redundant Break-Before-Make Switching (No source overlap) CBEMA ITIC compliant (2) 6 4 10 ±2 (0-20 selectable) Re-transfer time (s) 5 Instant Overcurrent Threshold Dimensions -Width -Height -Depth (w/o handles) (mm) (mm) (mm) 3 In 19" 2U 700 mm Weight (kg) 23 Safety CE marking, IEC/EN 62310-1 EMC Compatibility IEC/EN 62310-2 Frame color (RAL scale) 7016 Protection degree Acoustic Noise (dba) <45 MTTR (3) (1) At nominal voltage. (2) For CBEMA-ITIC curve please consult www.itic.org (3) In the case another CROSS Rack is available on site as spare. 9 IP20 <1 min

Notes 10

Notes

Ensuring The High Availability Of Mission-Critical Data And Applications. About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. The company provides new-to-the-world solutions, as well as established expertise and smart innovation in areas including AC and DC power and renewable energy, precision cooling systems, infrastructure management, embedded computing and power, integrated racks and enclosures, power switching and controls, and connectivity. Our solutions are supported globally by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at www.emersonnetworkpower.eu Locations Emerson Network Power Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 Via Fornace, 30 40023 Castel Guelfo (BO) Italy Tel: +39 0542 632 111 Fax: +39 0542 632 120 marketing.networkpower.emea@emerson.com United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Tel: +1 614 8880246 While every precaution has been taken to ensure accuracy and completeness herein, Emerson assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. MKA4CAT0UKCROSR Rev. 1-02/2013 Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road, Wanchai Hong Kong Tel: +852 2572220 Fax: +852 28029250 Emerson Network Power The global leader in enabling Business-Critical Continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.eu Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2013 Emerson Electric Co.