Cole-Parmer Instrument Company

Similar documents
Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Cole-Parmer Instrument Company

Operation Manual MODEL 3631 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Transmitter MANUFACTURER OF PRECISION INSTRUMENTS

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operating Instructions

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

OPERATION MANUAL MODEL TT-LP

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD.

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS,LTD. MANUFACTURER OF PRECISION INSTRUMENTS

OPERATION MANUAL. ph 500 (Cat. No ) MICROCOMPUTER BASED ph / Temperature TRANSMITTER & CONTROLLER

Operating Instructions

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100a

Operation Manual. MODEL ph 618N. Microcomputer Based ph & Temperature Pocket Meter. ph618n

WalkLAB ph mv/orptemperature

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

4801P ph/orp controller

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

ph, mv and Temperature Instrument

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Platinum RTD Thermometer MODEL NO

Platinum RTD Thermometer MODEL NO

Global Water Instrumentation, Inc.

Microprocessor ph/orp Controller

INSTRUCTION MANUAL ORP-METER MODEL COR-01

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus

24-hour Continuous Field Monitors

ph/orp Meter SD Card real-time Datalogger

AquaShock ph Meter K


Signet ph/orp Transmitter * *

OPERATION MANUAL. JENCO MODEL 6312 CTB MICROCOMPUTER BASED Conductivity/TDS & Temperature TRANSMITTER & CONTROLLER

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax:

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

INSTRUCTION MANUAL. ph/mv CONTROLLER/RECORDER

Thermo Scientific Orion Star A324 Portable ph/ise Meter. Instruction Sheet

Thermo Scientific Orion Star A325 Portable ph/conductivity Meter. Instruction Sheet

Instruction Manual. αlpha TDS /8 DIN Total Dissolved Solids Controller with Temperature display and Transmitter. 68X rev 0 08/2002

HI HI N HI HI

Economical Rugged Series M1300K

User Guide. ExStik FL700. Fluoride Meter

User's Guide. Extech AM A AC Analog Clamp Meter

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

+GF+ SIGNET ph/orp Transmitter Instructions

Specifications

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

HI ma Simulator

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

HI ma Simulator

Instruction Manual. PC 700 ph/mv/conductivity/ºc/ºf Bench Meter. Technology Made Easy...

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

Professional Benchtop Conductivity meter BC3020

Thermo Scientific Orion Star A326 Portable ph/rdo/do Meter. Instruction Sheet

Contents. 1. Installation

User's Guide. MiniTec TM Series Model MN25 MultiMeter

TX ph/mv Transmitter/Controller

User's Guide. Phase Sequence and Motor Rotation Tester Model

IVC-222HPII Precision Voltage/Current Calibrator

TC100 Precision Thermocouple Calibrator

Instruction Manual Temp JKT Temperature Meter Series

Thermo Scientific Orion Star A329 Portable ph/ise/conductivity/rdo/do Meter. Instruction Sheet

PH450 Analyzer Proper Calibration Steps

MODEL 245 / 345 High Range

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Operating Instructions

Instruction Manual. ph 700 ph/mv/ C/ F Bench Meter. Ion 700 ph/mv/ion/ C/ F Bench Meter. Technology Made Easy...

WK7200. Water Quality Test Kit USER S MANUAL

HI 3220 HI 3221 HI 3222

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

OPERATING INSTRUCTION MANUAL MODEL P/R60 & P/R65 DIFFERENTIAL PH & ORP PROBES

MULTI- PARAMETER TESTER

1875 Smart Calibrator. Instruction Manual

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

HI HI N HI HI

FLS M9.06. ph/orp MONITOR

AWP-24-3 Wave Height Gauge User's Guide

Datalogging Conductivity/ TDS Meter. Instruction Manual

Transcription:

Operating Instructions Cole-Parmer ph/orp 350 ph/orp Transmitter Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax: 1-847-247-2949 www.coleparmer.com

CONTENTS GENERAL INTRODUCTION.....2 INITIAL INSPECTION......2 USING THE ph/orp 350...3 A. Mounting procedure...3 B. Front panel...5 C. LCD screen...7 D. Rear connectors...9 E. Measure mode...10 F. Setting mode...11 G. ph calibration mode...17 H. RmV calibration mode...19 I. 4~20mA output...20 ERROR DISPLAY AND TROUBLESHOOTING.....23 ph BUFFERS.....27 SPECIFICATIONS.....29 WARRANTY......30 RETURN OF ITEMS......31 1

GENERAL INTRODUCTION Thank you for selecting the Cole-Parmer ph/orp 350. The ph/orp 350 transmitter is a rugged microprocessor based instrument assembled in a watertight 1/8 DIN case, designed for use in laboratories and process control applications. The system displays ph or ORP or Temperature status in one large LCD screen. The ph/orp 350 microprocessor performs a self-diagnostic routine every time you turn on the unit providing you with basic information on the stability of the instrument. The ph/orp 350 has an isolated 4-20mA analog output, offset and span configurable for the ph or ORP display. INITIAL INSPECTION Carefully unpack the unit and accessories. Inspect for damages made in shipment. If any damage is found, notify your Cole-Parmer representative immediately. All packing materials should be saved until satisfactory operation is confirmed. 2

USING ph/orp 350ERVIEW A. Mounting Procedure PANEL CUTOUT DIMENSIONS ± ± 0.813 0.032 92.0 0.000 3.622" 0.000 ± ± 45.0 1.772" 0.61 0.00 0.024 0.000 1. Make a cutout on any panel, with a thickness of 1/16 inch (1.5mm) to 3/8 inch (9.5mm). Refer to DRAWING 1. DRAWING 1 DRAWING 2 Mounting Brackets 3 2. Remove the mounting assembly from the controller and insert the controller into the cutout. Refer to DRAWING 2.

Panel DRAWING 3 Mounting brackets 3. Replace the mounting bracket assembly onto the controller and secure the controller to the mounting panel. Refer to DRAWING 3. Note : If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 4

B. Front Panel The front panel consists of a 4-digit LCD display and 4 keys. ph MODE STAND SLOPE 7.00 ATC ENTER 1. [ MODE ] key: 1a. In the Measure mode, this key will switch the display in sequence from ph, Temperature, ORP absolute mv, ORP relative mv and back to ph again. 1b. In the Calibration/Setting mode, pressing this key for three seconds will move you back to the previous parameter in the case when recalibration / resetting is required. 5

2. [ UP ] key: 2a. In the Calibration mode, pressing this key will show the next possible option. In the Setting mode, pressing this key will show the next possible option and increases the numeral increment. 2b. In the Measure mode, pressing this key and [ENTER] key at the same time, the unit will enter the Calibration mode. 3. [ DOWN ] key: 3a. In the Calibration mode, pressing this key will show the next possible option. In the Setting mode, pressing this key will show the next possible option and decreases the numeral increment. 3b. In the Measure mode, pressing this key and [ENTER] key at the same time, the unit will enter the Setting mode. 4. [ ENTER ] key: In any mode where the user can change the settings, pressing this key will save the new settings. If no change has been made then pressing this key will just move 6

the user to the next setting. C. LCD screen 1 2 3 4 5 ma C ph STAND SLOPE RmV 6.86 7.00 ATC MAN 6 7 8 9 10 11 12 1. Major LCD display. 2. This icon will be displayed if the meter is in the Calibration/Setting mode. 3. ma This icon, when displayed, indicate in the 4 ma or 20mA Setting mode. 7

4. Temperature and unit display. 5. ph Unit indicator. 6. STAND This icon will blink before Buffer 1 calibration. The icon will stay on while Buffer 1 is being calibrated. 7. SLOPE This icon will blink before Buffer 2 calibration. The icon will stay on while Buffer 2 is being calibrated. 8. 6.86 The 6.86 buffer group: 6.86, 4.00, 9.18. 9. 7.00 The 7.00 buffer group: 7.00, 4.01, 10.01. 10. ATC This icon will be displayed when a temperature probe is connected. 11. MAN This icon will be displayed when a temperature probe is not connected. 12. RmV Unit indicator. 8

D. Rear connectors INPUT RFF +V -V GND 10k TH Pt 1000 L N E 100~230VAC + - ma * Specify L = Live Lead 100 to 230 VAC Volts and N = Neutral Lead 1. Connect the AC line to the rear of the instrument. The ph/orp 350 can be used with 100~240V AC at 50/60 HZ. Make sure the EARTH connector is connected to the earth lead of the AC power line. 2. Set the proper load to the 4-20mA-output connector. Make sure that the load impedance is less than 500 Ohms. 9

3. V+ (5VDC) and V- (5VDC) output to provide excitation voltage for ph/orp pre-amplifier only. Note : (1) Make sure that the power is unplugged before wiring your probes etc. (2) Make sure you connect the AC power cord to the correct AC terminals. Connecting incorrectly may damage the unit permanently. E. Measure mode Turning on the unit will always display the Measure mode. This instrument is designed to provide 4 distinct measurements: ph MODE C MODE 7.00 ATC ATC mv MODE MODE RmV 10

1. ph The degree of acidity or alkalinity of the solution. 2. Temperature Current temperature of the solution. 3. ORP mv A measurement of absolute ORP mv. 4. ORP RmV A measurement of relative ORP mv. The offset value at the RmV calibration will be added to the ORP absolute value to display the ORP relative value. Note : ORP relative value range: ORP absolute value - 1000mV to ORP absolute value + 1000mV Pressing [MODE] key in the Measure mode will cycle the display from the four modes above. F. Setting mode Pressing [DOWN] key and [ENTER] key at the same time, the meter will enter into the Setting mode. 1. Temperature compensation select: 11

+ENTER ATC ATC MAN ENTER ENTER ENTER ph buffer 1 select Pressing [UP] key or [DOWN] key in this screen will cycle the display from 01 (Thermistor: 10k ohm) 02 (Resistor: PT1000) 03 (Manual) modes above. Select the preferred temperature compensation mode, press [ENTER] key to save, and enter the next setting screen. 2. ph buffer 1 select: Pressing [UP] key or [DOWN] key in this screen will cycle the display from 7.00 6.86 buffer above. Select the preferred buffer, press [ENTER] key to save, and enter the next setting screen. 12

ENTER Temperature compensation select ph ph 7.00 ENTER 6.86 ENTER ph buffer 2 select 3. ph buffer 2 select: Pressing [UP] key or [DOWN] key in this screen will cycle the display from 4.01 10.01 (or 4.00 9.18) buffer above. Select the preferred buffer, press [ENTER] key to save, and enter the next setting screen. 13

Buffer 1 7.00 ENTER Buffer 2 6.86 ENTER ph ph ph ph 7.00 ENTER 7.00 ENTER 6.86 ENTER 6.86 ENTER ma output parameters select ma output parameters select Note : The ph buffer 2 is either 4.01 or 10.01 if select 7.00 buffer at ph buffer 1 select screen. The ph buffer 2 is either 4.00 or 9.18 if select 6.86 buffer at ph buffer 1 select screen. 4. ma output parameters select: Pressing [UP] key or [DOWN] key in this screen will cycle the display from ph ORP mv ORP RmV modes above. Select the preferred mode, press [ENTER] key to save, and enter the next setting screen. 14

Buffer 2 select ENTER ph mv RmV ENTER ENTER ENTER 4mA output setting Note : The ma output will work with the choice of parameters. 5. 4 ma output setting: ma output parameters select ENTER ma ph ENTER 20mA output setting 15

Pressing [UP] key or [DOWN] key in this screen to adjust the 4 ma value, this value is used for scaling the 4-20mA analog output. Pressing [ENTER] key to save, and enter the next setting screen. 6. 20mA output setting: 4mA output setting ENTER ma ph ENTER Measure mode Pressing [UP] key or [DOWN] key in this screen to adjust the 20 ma value, this value is used for scaling the 4-20mA analog output. Pressing [ENTER] key to save, and goes to the Measure mode. 16

G. ph Calibration mode The model ph/orp350 uses 2-point calibration for ph. The first point must be 6.86/7.00, and the second point can either be 4.00/4.01 or 9.18/ 10.01. In the ph Measure mode, pressing [UP] key and [ENTER] key at the same time to allow the meter to go to the ph Calibration mode. 1. Buffer 1 (STAND) calibration: HI2 ph +ENTER ph ENTER ph STAND SLOPE 7.00 STAND 7.00 STAND 7.00 Buffer 2 calibration Enter into the ph calibration mode, the STAND icon will flash, the unit is ready to be standardized at the first buffer. Rinse the ph and ATC/Temp probes in distilled water and immerse them in the first buffer solution (either 7.00 or 6.86). Allow temperature reading to stabilize, then press ENTER key to calibrate. The ph 17

icon will flash until the unit detects a stable reading. Once the unit calibrates the first point, the SLOPE icon will flash. The unit is ready to be sloped at the second buffer. 2. Buffer 2 (SLOPE) calibration: Buffer 1 calibration ph ENTER ph Measure mode STAND SLOPE 7.00 STAND SLOPE 7.00 Rinse the ph and ATC/Temp probe in distilled water and immerse them in the second buffer solution (either 4.00/4.01 or 9.18/10.01). Allow temperature reading to stabilize, then press ENTER key to calibrate. The ph icon will flash until the unit detects a stable reading. Once the unit calibrates the second point and the unit will automatically exit the Calibration mode and goes to the ph Measure mode. Dual point calibration is complete. 18

Note : In the Setting mode (1. Temperature compensation select), select 03 (Manual temperature compensation mode) if no temperature probe is being used. Press the [UP] key or [DOWN] key in the Manual temperature compensation mode to adjust the value to that of the test solution temperature. Then calibrate buffer 1 and buffer 2. H. RmV Calibration mode +ENTER or RmV RmV RmV Rmv normal mode The model ph/orp350 uses 1-point calibration for RmV. In the RmV Measure mode, pressing [UP] key and [ENTER] key at the same time, the meter will enter into RmV calibration mode. 19

Rinse the ORP probe in distilled water and immerse it in the ORP standard solution, then press [UP] or [DOWN] key to adjust the ORP value to that the ORP standard. Press [ENTER] key to save. The unit beeps to indicate a successful calibration. Calibration is now complete and the unit will automatically switch to the ORP relative mv Measure mode. Note : When the ORP absolute mv reading is off, recalibrate RmV value. I. 4-20 ma output 1. Isolation voltage: The maximum isolation voltage of the 4-20mA output contacts is 500 VDC. The voltage differential between the 4-20mA output contacts and the load should not exceed 500 VDC. 2. Output load: The maximum load is 500 ohm. Output current inaccuracies may occur for load impedance in excess 500 ohm. 20

3. The analog output will produce a linear analog output. The user can only bind the ANALOG OUTPUT to one reading at a time. The user can change this anytime by changing option at the Calibration/Setting mode screen. The analog output will be restricted on the 4 ma setting, 20 ma setting and the current bound display. ma ma 20mA 20mA 4mA Adjustable Bandwidth Set point Decreasing current for increasing ph or ORP ph/orp 4mA Adjustable Bandwidth Set point Increasing current for increasing ph or ORP ph/orp 21

The above figure shows the relationship between Reading, U 4mA & U 20mA. The analog output is based on the following equation: ma(output) = 4mA+(16mA)*(D U 4mA ) / (U20 ma - U 4mA ) Where: ma(output) = analog output D = current bound display U 4mA U 20mA = user setting for 4 ma for current bound display = user setting for 20 ma for current bound display Note : 1. The ideal range of U 4mA and U 20mA for ph is -2.00 to 16.00 ph. 2. The ideal range of U 4mA and U 20mA for absolute mv is -2000 to 2000 mv. 3. The ideal range of U 4mA and U 20mA for relative mv is -3000 to 3000 mv. 22

ERROR DISPLAY AND TROUBLESHOOTING ERVIEW ph/orp Temperature Possible cause(s) Display Mode Display Display [Action(s)] "OvEr" -10.0~120.0 C ph measure mode ph > 16.00pH [Recalibrate] Undr -10.0~120.0 C ph measure mode ph < -2.00pH [Recalibrate] "OvEr" "OvEr" ph measure mode a. Temperature > 120.0 C. [Bring buffer solution to lower temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] 23

"OvEr" Undr ph measure mode a. Temperature < -10.0 C. [Bring buffer solution to higher temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] "OvEr" Temperature Absolute ORP mv Absolute ORP mv > +1999 mv reading or relative ORP [Bring solution to a lower ORP reading] "Undr" Temperature Absolute ORP mv Absolute ORP mv < -1999 mv reading or relative ORP [Bring solution to a higher ORP reading] 24

ORP "OvEr" Absolute ORP mv a. Temperature > 120.0 C. reading or relative ORP [Bring buffer solution to lower temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] ORP "Uder" Absolute ORP mv a. Temperature < -10.0 C. reading or relative ORP [Bring buffer solution to higher temperature.] [Replace temperature probe.] b. No temperature sensor. [Adjust the manual temperature to -10~120 C.] 25

"OvEr" 0~60 C a. ph calibration mode-buffer 1 (STAND)-7.00 b. ph calibration mode-buffer 1 (STAND)-6.86 c. ph calibration mode-buffer 2 (SLOPE) a. Offset < -100 or > 100 mv b. Offset < -91.7 or > 108.3 mv c. Slope > ideal mv by 30% [Use a new buffer solution.] [Replace electrode.] 26

ph BUFFERS The temperature characteristics of ph calibration buffers ph4.00, ph4.01, ph6.86, ph7.00, ph9.18 & ph10.01 are stored inside the instrument. The buffers used to calibrate the instrument must exhibit the same temperature characteristics as the stored values. C 4.00 6.86 9.18 4.01 7.00 10.01 0 4.01 6.98 9.46 4.01 7.11 10.32 5 4.00 6.95 9.39 4.01 7.08 10.25 10 4.00 6.92 9.33 4.00 7.06 10.18 15 4.00 6.90 9.28 4.00 7.03 10.12 20 4.00 6.88 9.23 4.00 7.01 10.06 25 4.00 6.86 9.18 4.01 7.00 10.01 30 4.01 6.85 9.14 4.01 6.98 9.97 35 4.02 6.84 9.10 4.02 6.98 9.93 27

40 4.03 6.84 9.07 4.03 6.97 9.89 45 4.04 6.83 9.04 4.04 6.97 9.86 50 4.06 6.83 9.02 4.06 6.97 9.83 55 4.07 6.83 8.99 4.08 6.97 9.80 60 4.09 6.84 8.97 4.10 6.98 9.78 Note : The actual reading of the instrument can differ from the values shown by ±0.01 ph. 28

SPECIFICATIONS Mode Range Resolution Accuracy ph -2.00 to 16.00 ph 0.01 ph ±0.1% ± 1 digit ORP Absolute mv -1999 to 1999 mv 1 mv ±0.1% ± 1 digit ORP Relative mv -2999 to 2999 mv 1 mv ±0.1% ± 1 digit Temperature -10.0 to 120.0 C 0.1 C ±0.3 C ph: Recognized ph buffers US (4.01, 7.00, 10.01) or NIST (4.00, 6.86, 9.18) ph Temperature compensation Manual/Auto -10.0 C to 120.0 C ph Buffer Temperature range 0.0 C to 60.0 C ph Electrode Offset recognition 100 mv at ph 7.00 +108.3 mv/-91.7 mv at ph 6.86 29

ph Electrode Slope recognition 30% at ph 4.00, 4.01, 9.18, 10.01 Input impedance >10 12 Calibration end point sensing Yes Temperature: Temperature sensor Thermistor: 10k ohm at 25 C, (User selectable) Resistor ( PT1000) or Manual 4-20 ma output: Current output range 4 to 20 ma (isolated) Current output scale user programmable Maximum load 500 ohm Accuracy ±0.03 ma Isolation voltage 500VDC General: Keys Audio feedback in all keys Power: 100VAC to 240VAC, 50/60Hz 30

Ambient Temperature range 0.0 to 50.0 C Case IP65, 1/8DIN case, depth 90mm Weight 290 g WARRANTY The Cole-Parmer Instrument Company warrants this product to be free from significant deviations in material and workmanship for a period of one year. If repair or adjustment is necessary and has not been the result of abuse or misuse, within the twelve month period, please return, freight-prepaid, and correction will be made without charge (see note on return of items). Cole-Parmer alone will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired for a nominal charge. 31

RETURN OF ITEMS Authorization must be obtained from our Customer Service Department before returning items for any reason. When applying for authorization, please include data regarding the reason the items are to be returned. A restocking charge will be made on all unauthorized returns. For your protection, items being returned must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Cole-Parmer will not be responsible for damage resulting from careless or insufficient packing. Note : The Cole-Parmer Instrument Company reserves the right to make improvements in design, construction and appearance of our products without notice. We stand behind our products. For additional information on our products, warranty, or returns please contact our office or visit our website listed on front page. 32

英文说明书 机型 :ph/orp 350 编制人 : 汪蕾 日期 :2012-09-10 文件编号 :KpH/ORP350-01 修改人 : 汪蕾 日期 :2012-09-10 版本 :01 核准人 : 日期 : 33