Similar documents
Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor EX-BNS40S. 1. About this document. Content

Operating instructions Safety sensor BNS About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Encontrará el manual de instrucciones actual en su idioma oicial de la UE en nuestra página de Internet

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

Operating instructions Two-hand control panel and stands. SEPK02.0 / SEPG05.3 / SEP01.0 /SEP01.4 / SEPLC05.2 / SEP07.0 / SEP09.

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC/B SRB 301LC/B-R. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Operating instructions Safety-monitoring module SRB 324ST V.3. 1 About this document

Operating instructions Safety sensor RSS About this document. Content. 7 Set-up and maintenance 7.1 Functional testing 8 7.

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

Operating instructions Safety-monitoring module SRB 207AN. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

Datasheet - BNS ZG

Operating instructions Command and signalling devices. E programme, N programme and R programme. 1. About this document. Content

Datasheet - BNS ZG-ST

Position detection with system The new compact position switches PS116

Operating instructions Safety light curtain / safety light grid SLC440COM SLG440COM. Version 2.0. Content. 1. About this document

Datasheet AZM 161 Z ST1 AS RA

Datasheet - CSS 11-30S-D-M-ST

Datasheet - SRB 301LC/B-24V

Datasheet - RSS 36-D-R-ST

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - SRB 402EM-24V

Position detection with system The new compact position switches PS116

SR B series coded magnetic safety sensors

Datasheet SRB301ST 24V (V.2)

Datasheet - AZM300Z-ST-1P2P-A

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Safety light barriers SLB440. Content. 1. About this document

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

SR A series coded magnetic safety sensor

Datasheet - AZ 16-02ZVRK-ST

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Safe switching and monitoring Non-Contact Safety Sensors

Operating instructions. Switching amplifier DN0210 DN / / 2015

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-03ZVRK

Operating instructions. Speed monitor D / / 2014

Safety field box for PROFINET / PROFIsafe systems SFB-PN-IRT-8M12-IOP

Non-Contact Guard Monitoring Safety System BNS/AES

Safety coded magnetic sensor SR A series

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVRK

SolConeX extra-low voltage flange socket

Datasheet - AZM 200SK-T-1P2PW

Safety coded magnetic sensor SR B series

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Safety coded magnetic sensor SR B series

Datasheet - AZ 15 ZVK

Operating Instructions

Operating instructions Joystick switch RK/NK. 1. About this document. Content

Operating Instructions

Operating instructions Safety light curtain / safety light grid SLC445 SLG445. Content

Datasheet - AZ 16ZVRK

Datasheet - AZ 15 ZVRK

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Datasheet - SLB 200-C04-1R

Safety coded magnetic sensor SR A series

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Coded magnetic safety sensor SR B series

Datasheet - ZR Z

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Transcription:

Operating instructions Safety sensor BNS 0 About this document x.000 / v.a. / 0.00 / BZ-Nr. 000-V900_ / Teile-Nr. 8 / Ausgabe H Operating instructions... pages to Translation of the original operating instructions FR NL JP Content Vous trouverez la version actuelle du mode d emploi dans votre langue nationale officielle sur l Internet, www.schmersal. net. U vindt de huidige versie van de gebruikshandleiding in uw officiële landstaal op het Internet, www.schmersal.net. EU 公用語で書かれた最新の取扱説明書は インターネッ (www.schmersal.net) からダウンロードできます ES IT Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net. Il manuale d istruzioni aggiornato nella vostra lingua (lingua ufficiale UE) è scaricabile in Internet all indirizzo www. schmersal.net. About this document. Function............................................... Target group: authorised qualified personnel................... Explanation of the symbols used............................ Appropriate use......................................... General safety instructions................................ Warning about misuse....................................7 Exclusion of liability..................................... Product description. Ordering code.......................................... Special versions......................................... Destination and use...................................... Technical data.......................................... Safety classification..................................... Mounting. General mounting instructions.............................. Dimensions............................................ Axial misalignment....................................... Adjustment............................................ Electrical connection. General information for electrical connection................... Contact variants......................................... Connector plug......................................... Set-up and maintenance. Functional testing........................................ Maintenance.......................................... Disassembly and disposal. Disassembly............................................ Disposal.............................................. 7 Appendix 7. EC Declaration of conformity............................... Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device.. Target group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.. Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.. Appropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant. The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description".. General safety instructions The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www. schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. If multiple safety components are wired in series, the Performance Level to ISO 89- will be reduced due to the restricted error detection under certain circumstances. The entire concept of the control system, in which the safety component is integrated, must be validated to ISO 89-. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.

Safety-Sensor BNS 0. Warning about misuse In case of inadequate or improper use or manipulations of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard 088 must be observed..7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. Product description. Ordering code This operating instructions manual applies to the following types: BNS 0-➀➁Z➂-➃-➄-➅ No. Option Description ➀ Safety contacts: NO contact / NC contact 0 NC contacts ➁ Signalling contacts: no signalling contact /0 NC contact ➂ without LED G with LED ➃ Connecting cable ST Integrated connector ➄ L Door hinge on the left-hand side R Door hinge on the right-hand side ➅ LST-7 Connecting cable ( m) with connector HAN Q. Special versions For special versions, which are not listed in the order code below., these specifications apply accordingly, provided that they correspond to the standard version.. Destination and use The BNS 0 safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards to 088 and IEC 097--.To actuate the safety sensors, only the BPS 0- or BPS 0- actuators can be used, conventional magnets are not suitable. Only the entire system consisting of the safety sensor (BNS 0), the actuator (BPS 0- or BPS 0-) and the safety-monitoring module (AES, SRB) meets the requirements of the standard IEC 097--. The safety switches are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened. Connecting multiple safety sensors to one AES safety-monitoring module is technically possible. To connect multiple safety sensors (check if authorised!), the NO contacts are wired parallel and the NC contacts in series. The Protect-IE- or -0 or PROTECT-PE- (-AN) input expander module can be used to connect up to safety sensors with NC/NC or NC/NO contacts. BNS 0 safety sensors equipped with LED's shall not be wired in series, except with the Protect-IE input expander module. As a result of this, the luminosity of the LED's would considerably decrease and the voltage could drop below the minimum input voltage of the downstream safety-monitoring module. Recommended suitable safety-monitoring modules BNS 0-... in combination with -Z(G), -/0Z(G): AES../../../../../../ AES../07 SRB 0CA, -CA/T, -CA/Q, -CA/QT SRB 00CA, CA/T, -CA/Q, -CA/QT SRB AN V., SRB 07AN, -Z, -/0Z (without LED): SRB 0AN, AES 7 -/0Z (without LED): AES 0,,, 7-0Z(G), -0/0Z(G): AES */AES * SRB 0CS, -CS/T SRB ST V., SRB LT SRB 00CS, -CS/T, SRB 0 LC/B, SRB 0MC -0Z, -0/0Z (without LED): SRB 9IT, SRB 08IT, SRB 0ST * Switching the AES safety-monitoring module over to two NC contacts - refer to the mounting and wiring instructions of the AES (no cross-wire short detection) In case of series-wiring at SRB max. sensor with LED indication for U N. In the elevator construction, the BNS 0 safety sensor is used in combination with the AES 907 safety-monitoring module.. Technical data Standards: IEC 097--, ISO 89-, BG-GS-ET- Enclosure: glass-fibre reinforced thermoplastic Protection class: IP 7 to 09 Termination: LIYY cable or M8 connector Connecting cable: x 0. mm with signalling contact: x 0. mm² Version with integrated connector: M8 x, -pole with signalling contact: M8 x, -pole Tightening torque for max. 0. Nm connectors: Connecting cable with x 0. mm; HAN Q, -pole Harting-connector: Operating principle: magnetic Actuator: BPS 0-, BPS 0-, coded Limit distances: assured switching distance mm s ao : assured switch-off distance mm s ar : Switching condition indication: LED only with ordering suffix G Switching voltage: without LED: max. 7 VDC with LED: max. VDC with -pole connector: max. 0 V Switching current: without LED: max. 00 ma with LED: max. 0 ma Switching capacity: without LED: max. 0 VA with LED: max. 0 mw Ambient temperature: - C... +70 C Storage and transport - C... +70 C temperature: Max. switching frequency: Hz Resistance to shock: 0 g / ms Resistance to vibrations: 0... Hz, amplitude mm For use in NFPA 79 Applications only. Adapters providing field wiring means are available from the manufacturer. Refer to manufacturers information.

Safety-Sensor BNS 0. Safety classification Standards: ISO 89- B 0d (NC/NO contact):,000,000 Service life: 0 years Sensor with cable, door hinge on the left-hand side 9, MTTF d B0d dop x hop n x 00 s/h op 0, x n op t cycle (Specifications can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) An individual switch can be used in a category or architecture up to PL e. Mounting. General mounting instructions Fitting is only authorised in a de-energised condition Do not use the sensor and the actuator as a mechanical backstop. Any mounting position, provided that the active surfaces are opposite Inseparably fix the sensor and the actuator to the safety guard Exclusively mount the safety sensor on flat surfaces to avoid tensile stresses that could damage the sensor or lead to varying switching distances Do not install the safety sensor and the actuator in strong magnetic fields If possible, do not mount the sensor and the actuator on ferromagnetic material. A non-magnetic spacer of at least mm thick or the original spacer must be used. The use of non-magnetic fixing screws is recommended as well. Do not subject the safety sensor and actuator to extreme vibrations and shocks. Keep away from metal chips The mounting distance between two sensors should always be at least 0 mm. Dimensions All measurements in mm. Sensor with connector, door hinge on the right-hand side, 9 LED Actuator, 9 000. Axial misalignment A horizontal and vertical misalignment of the safety sensor and the actuator is tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range. The specified switching distances refer to opposedly mounted safety sensors and actuators. 7,,,,, 0 BPS 0-

Safety-Sensor BNS 0. Connector plug BPS 0- assured switching distance: assured switch-off distance:,,,,, 0 s ao = mm s ar = mm. Adjustment The LED of the BNS 0 variants can only be used as a rough setting tool. The proper functionality of both safety channels must be checked by means of the connected safety-monitoring module. Integrated connector M8, -pole M8, -pole HAN Q, -pole Accessories: connecting cable with M 8 coupling BN -pole m m 0 m WH BU BK straight 8 78 - angled 090 090 - Electrical connection. General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. The safety sensors must be wired in accordance with the wire colours or the pin configuration.. Contact variants The contact position shows the actuated sensor function when the safety guard is closed. For safety sensors with LED, the LED is illuminated when the safety guard is closed. The contact configurations of the versions with or without LED are identical. Safety contacts: Signalling contact: S-S and S-S or S-S S-S -pole m m 0 m GN YE straight 000 00 00 GY PK WH angled 00 00 00 BN Accessory: Y-adapter BNS-Y- BNS 0-Z -z The numbers between brackets indicate the PIN configuration of the versions with integrated connector; indication of the wire colours for the version with cable. BNS 0-0Z(G) () () BK S WH S S BU () S BN () AES SRB S S S S BNS-Y- BNS 0-Z(G) () BK S () WH S S BU () S BN () Accessory: Y-adapter BNS-Y-0 BNS 0-0z 0-0Z BNS 0-0/0Z(G) () GY S () GN S () WH S S PK () S YE () S BN () BNS 0-/0Z(G) () GY S () GN S () WH S BNS 0-Z-L-LST-7 () BU S () WH S S PK () S YE () S BN () S BK () S BN () AES SRB S S S S BNS-Y-0

Safety-Sensor BNS 0 Set-up and maintenance. Functional testing The safety function of the safety components must be tested. The following conditions must be previously checked and met:. Fitting of the sensor and the actuator. Fitting and integrity of the power cable. The system is free of dirt and soiling (in particular metal chips). Maintenance In the case of correct installation and adequate use, the safety sensor features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended: Check the fitting of the sensor and the actuator Remove possible metal chips Check the cable for damage. Disassembly and disposal. Disassembly The safety switchgear must be disassembled in a de-energised condition only.. Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. Damaged or defective components must be replaced.

Operating instructions Safety sensor BNS 0 7 Appendix 7. EC Declaration of conformity EC Declaration of conformity Translation of the original operating instructions K.A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 0, D-79 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described safety components both in its basic design and construction conform to the applicable European Directives. Name of the safety component / type: BNS 0 Description of the safety component: Coded safety-sensor with magnetic operating principle in combination with the AES / SRB safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the IEC 097--. Harmonised EC-Directives: 00//EC EC-Machinery Directive Person authorized for the compilation of the technical documentation: Ulrich Loss Möddinghofe 0 79 Wuppertal Place and date of issue: Wuppertal, March, 00 BNS 0-C- Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 0, D - 79 Wuppertal Postfach 0, D - Wuppertal Telefon +9 - (0) 0-7 - 0 Telefax +9 - (0) 0-7 - 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com