Melsec-Q Link(SIO) Driver

Similar documents
Melsec-Q CPU (SIO) Driver

Yaskawa Electric MP900 Series Driver

Schneider Electric TSX07/37/57 Series Unitelway Driver

Mitsubishi QSeries QnA Serial Communication

Toyopuc Link(SIO) Driver

A Series CPU Direct Driver

Magelis XBT-G Modbus (RTU) driver. eng

Pro-face Memory Link(SIO) Driver

Mitsubishi <12> Mitsubishi Electric Corporation Q Series (A Mode) CPU Direct Connection

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL. Keyence Corporation PLC

Device/PLC Connection Manuals

FA-M3 Ethernet (TCP) Driver

Device/PLC Connection Manuals

Mitsubishi Serial Driver Help Kepware Technologies

Wonderware Operations Integration Supervisory Mitsubishi Electric MELSEC Server (G-1.2 Series)

Device/PLC Connection Manuals

Device/PLC Connection Manuals

OMRON Corporation PLC SYSMAC CJ1M Series Connection

Device/PLC Connection Manuals

Device/PLC Connection Manuals

Power Mate Series Driver

Device/PLC Connection Manuals

SIMATIC S5 CPU Direct Driver

Device/PLC Connection Manuals

Mitsubishi FX3 Driver Configuration Manual

ICC. Mitsubishi MELSEC Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

SIMATIC S5 CPU Direct Driver

Modbus TCP Client Ethernet Modbus TCP Client Modbus TCP Server Ethernet Modbus TCP Server 5

Device/PLC Connection Manuals

OMRON Corporation PLC SYSMAC C Series Connection

User Manual Connection to Mitsubishi MelsecA

SAPHIR SIO Driver. Siemens Building Technologies

XGK Series CPU Direct Driver

Station 2. Inverter. PU connector (Note1)

Flexi Soft Driver SICK AG

Device/PLC Connection Manuals

Device/PLC Connection Manuals

Device/PLC Connection Manuals

OMRON Corporation PLC SYSMAC C Series Connection

Connecting to the Handy Type GP

Eaton Corporation Cutler-Hammer Business Unit 811 Green Crest Drive Columbus, OH PanelMate Mitsubishi Communication Driver Manual

DF1 Driver. Rockwell Automation, Inc.

Mitsubishi CNC Ethernet Driver Help Kepware Technologies

Mitsubishi Ethernet Driver Kepware, Inc.

EIO /2011. Magelis HMISTO501. Zelio/Millenium Driver 07/2011 EIO

MELSECA - Driver of MITSUBISHI MELSEC-A PLC Protocol User s Manual

PC CONNECTION Programmable Terminal Operation Manual

SIMATIC S5 3964(R) Driver

1.1 Siemens S5/S7 Series

SIMATIC S7 MPI Direct Driver

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

KTA-250 Anemometer Alarm Card

TABLE OF CONTENTS. Communication Functions

Citect for Windows, Version 5.xx MXCOMP driver, User information and design

Device/PLC Connection Manuals

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Appendix 3 Using NS-AL002 Converters

XGT/XGB Series Cnet V1.5

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL ADDITIONAL MANUAL. Fuji Electric MICREX-SX Series

PC CONNECTION Programmable Terminal OPERATION MANUAL

T1K MODBUS Base Controller Specifications

PLC Driver Manual 2800 & 2900

Hi5 Robot Driver. Hyundai Heavy Industries

Mitsubishi CNC Ethernet Driver PTC Inc. All Rights Reserved.

Appendix G. CJ1W-CIF11 RS-422A Converter

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: GR8-EM. Communication Adaptor GR8 Series

USER S MANUAL Enhanced Communication Function

UC-2000 Installation Manual Unicorn Computers Technology Limited

USER'S MANUAL - MODBUS Serial Communication Edition FX3U SERIES PROGRAMMABLE CONTROLLERS

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

RS485 MODBUS Module 6RO

SIEMENS S7-200 PPI Direct

How-To. Modbus-TCP communication between CelciuX and NJ. History

MELSEC iq-f FX5 User's Manual (MODBUS Communication)

Connection Cable Communication 232C Port Method GP 1762-L24BWA. the CPU Unit RS-232C

Device/PLC Connection Manuals

Programmable Terminals

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

Device/PLC Connection Manuals

SLMP Reference Manual

APP /07/00 KEEP WITH USER MANUAL. Application Note for Using the Operator Station HE500TIU050/10X/11X/20X with the Mitsubishi A PLC Protocol

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

MICRO 3 C PLC User s Manual

RS485 MODBUS Module 8I8O

GE MDS, LLC. NETio Series. Protocol Communications Supplement. March 2013 Part No A01, Rev. C

Mitsubishi FX Series ONTROLLER NFORMATION HEET. Overview. Communications Cable. PLC Settings

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Connecting UniOP to Fatek Controllers with Facon Protocol

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Sharp JW10 Serial Programmable PLC Device Driver Guide

COM-2CL-PCI COM-4CL-PCI. Features. Packing List. PCI-compliant 2 port Isolated RS-232C. PCI-compliant 4 port Isolated RS-232C

Safety Precautions. Copyright / Trademarks

Citect for Windows Driver Specification Extract Hitachi Driver

Pass-Through Function

RS485 MODBUS Module 16I-M

Package Contents. GP Options (Made by Digital)

Transcription:

Mitsubishi Electric Melsec-Q Link(SIO) Driver 1 System Structure 2 Diagrams 3 Supported Device Addresses 4 Consecutive Device Addresses 5 Environment Setup 6 I/O Manager Configuration 7 Driver Configuration 8 Protocol Configuration 9 Device Address Configuration This manual explains how to connect the target machine with other manufacturer devices. For information about how to use the Pro-Designer software, please refer to the Pro-Designer Online Help. The types of target machines that are compatible with Pro-Designer depends on the version of Pro-Designer. For information about the compatibility of target machines, please refer to the Pro-Designer Online Help. 2002 Digital Electronics Corporation. All rights reserved.

1 System Structure The following table describes the basic system setup for connecting the target machine to Mitsubishi MELSEC-Q Series link module PLCs over a serial connection. To view a cable connection diagram for a particular communication format, see Section 2 Diagrams. Series CPU Link I/F Comm. Format Diagram MELSEC-Q Series Q00JCPU Q02CPU Q02HCPU Q06HCPU Q12HCPU Q25HCPU Q00CPU Q01CPU QJ71C24-R2 QJ71C24 CPU Direct *1 QJ71C24-R2 QJ71C24 RS-422(4-wire) RS-422(4-wire) Diagram 1 Diagram 1 Diagram 2 Diagram 3 Diagram 1 Diagram 1 Diagram 2 *1 Connect to the CPU s port. 2

2 Diagrams The illustrated cable diagrams and those recommended by Mitsubishi may differ. However, Proface recommends using the following diagrammed connections. Ground the PLC s FG terminal according to your country s applicable standard. For details, refer to the PLC manual. When making your own communication cable, be sure to connect the SG signal. Diagram 1 To connect the target machine and the PLC, use a recommended cable or create your own cable using the following specifications. Target Machine / Adapter Comments GP, PS-P, PC/AT(PL), PS-G Mitsubishi Exclusive (Proface: GP000-IS02-MS (3m) ) User-created When connecting to a 9pin port on the target machine, use a 9-25pin conversion adapter. length: 15m max. 3

Diagram 2 RS-422 (4-wire) To connect the target machines and the PLC, use a recommended cable (and a pin adapter if necessary), a signal converter, or create your own cable using the following specifications. Target Machine / Adapter RS-422 Connection Terminal Adapter a GP, PS-P (Pro-face: GP070-CN10-O) b User-created PC/AT(PL), PS-G a / RS-422(485) Signal Converter Comments length: 500m max. Use shielded twisted-pair cables for noise immunity. Connect the cable shields, then connect the cable to a single-point ground. Turn on the PLC s termination resistance switch. If no dip switch is available, depending on the PLC model you may need to add a termination resistance of 330Ω 1/2W on the PLC between SDA and SDB, and also between RDA and RDB. (Not illustrated) a. RS-422 Connection Terminal Adapter (Pro-face: GP070-CN10-O) OR: /RS-422(485) Signal Converter As the RS-422(485) side of the /RS-422(485) signal converter is a terminal, use any external line other than the communication line for the power cable. Follow the specifications for your /RS-422(485) signal converter when connecting termination resistance on the RS-422(485) terminal. The connection between the /RS-422(485) signal converter and target machine depends on the signal converter. Refer to its specifications when connecting the signal converter and target machine. 4

b. User-created Diagram 3 To connect the target machine and the PLC, use th recommended cable (and a pin adapter if necessary). Target Machine / Adapter Comments GP, PS-P, PC/AT(PL), PS-G (Mitsubishi: QC30R2 (3m) OR Diatrend: DQCABR2*-H (*m)) Be sure the cable type used/selected fits the target unit's serial I/F connector. Attaching a ferrite core will reduce the amount of noise in the cable (see the following diagrams.) Attach two ferrite cores to the cable, one at each end. Loop the cable once around each ferrite core. 9pin female Target Machine Mitsubishi QC30R2 Loop Ferrite Core Holders secure the ferrite core in place Mini DIN 6pin PLC Ferrite Core 3m 5

Mini DIN 6pin Target Machine Loop Diatrend DQCABR2*-H (*m) Ferrite Core Holders secure the ferrite core in place PLC Ferrite Core When you require a cable 3m or longer, use the Diatrend cable. Recommended Ferrite Core Maker :Seiwa Electronics Corporation 39mm 34mm 13mm 30mm Model :E04SR301334 You can use ferrite cores from other manufacturers, but make sure they are the same size as defined here. <Adaptor : Roas Co. Model No. ZA-403> Dsub 25pin male Lock-screw (mm) Dsub 9pin male Lock-nut (inch) 6 cm 6

3 Supported Device Addresses The following table lists the device address ranges you can enter from the Device Address Keypad. For actual device address ranges supported by the PLC, refer to the corresponding PLC manual. Supported device addresses differ from protocol to protocol and between PLC models. Device Bit Address Word Address 16 bit 32 bit Input Relay X0000-XFFFF X0000-XFFF0 *1 Output Relay Y0000-YFFFF Y0000-YFFF0 *1 Internal Relay M00000-M65535 M00000-M65520 *2 Latch Relay L00000-L65535 L00000-L65520 *2 Special Relay SM0000-SM9999 SM0000-SM9984 *2 Annunciator F00000-F65535 F00000-F65520 *2 Edge Relay V00000-V65535 V00000-V65520 *2 Step Relay S0000-S9999 S0000-S9984 *2 Link Relay B0000-BFFFF B0000-BFFF0 *1 Special Link Relay SB000-SBFFF SB000-SBFF0 *1 Timer (contact) TS00000-TS65535 Timer (coil) TC00000-TC65535 Retentive Timer (contact) SS00000-SS65535 Retentive Timer (coil) SC00000-SC65535 Counter (contact) CS00000-CS65535 Counter (coil) CC00000-CC65535 Timer (current value) TN00000-TN65535 Retentive Timer (current value) SN00000-SN65535 Counter (current value) CN00000-CN65535 Data Register *3 D00000:0-D65535:15 D00000-D65535 *4 Special Register *3 SD0000:0-SD9999:15 SD0000-SD9999 *4 Link Register *3 W0000:0-WFFFF:F W0000-WFFFF *5 Special Link Register *3 SW000:0-SWFFF:F SW000-SWFFF *5 File Register(Normal) *3 R00000:0-R65535:15 R00000-R65535 *4 0R0000:0-0R7FFF:F 0R0000-0R7FFF *5 1R0000:0-1R7FFF:F 1R0000-1R7FFF *5 File Register(0R-31R) *3 2R0000:0-2R7FFF:F 2R0000-2R7FFF *5...... 30R0000:0-30R7FFF:F 30R0000-30R7FFF *5 31R0000:0-31R7FFF:F 31R0000-31R7FFF *5 LH *6 LH *6 *1 To use as word address, the bit column (last column) must be 0. *2 To use as word address, must be multiple of 16. *3 When the bit write operation is performed, the Target Machine reads the PLC s corresponding word address and turns a bit ON, then send back to PLC. Do not write to the word address from the ladder program in the middle of this operation. *4 You can define a bit address by adding a colon followed by the bit position (0~15) at the end of the word. (e.g. D0100:8) *5 You can define a bit address by adding a colon followed by the bit position (0~F) at the end of the word. (e.g. W0001:A) 7

*6 16-bit and 32-bit data, High and Low, refer to data as defined in the following examples. Byte 16 bit Word 32 bit 0 7... 0 L (Low) 0 15... 0 L (Low) 1 15... 8 H (High) 1 31... 16 H (High) 8

4 Consecutive Device Addresses The following table lists the maximum number of consecutive addresses that can be read by each PLC. Refer to this table when using block transfers. To speed up data communication, use consecutive device addresses on the same panel screen. The following situations increase the number of times that the device is read, and reduces the data communication speed between the target machine and the PLC: when the number of consecutive addresses exceeds the maximum when an address is designated for division when different device types are used Device Input Relay (X) Output Relay (Y) Internal Relay (M) Latch Relay (L) Link Relay (B) Timer [contact] (TS) Timer [coil] (TC) Counter [contact] (CS) Counter [coil] (CC) Data Register (D) Link Register (W) File Register (R) Extended File Register (R) Timer [current value] (TN) Counter [current value] (CN) Max. Consecutive Address es Gap Span 2000 bits 15 bits 480 words 16 words 9

5 Environment Setup The following table lists the communication settings, recommended by Pro-face, for the target machine and Mitsubishi Melsec PLCs. For details, see Section 7 Driver Configuration, and Section 8 Protocol Configuration. Target Machine PLC Settings Serial Interface Mode 5 (Format 5 Protocol mode) Flow Control DTR(ER)/CTS Transmission Speed 19200 bps Baud Rate 19200 bps Driver Retry Count 2 Parity Bit Even Parity Check Parity Bit Stop Bit 2 bit Stop Bit 2 bit YES EVEN Data Length 8 bits Data Length 8 bits Rcv Timeout 10 sec TX Wait Time 0 msec Write possible in RUN mode Possible Checksum Yes Station No. 0 Station No. 0 Network No. 0 Network No. 0 Protocol PLC No. 255 PC No. 255 Request destination module I/O No. 1023 Request destination module station No. 0 10

(CPU Direct) Driver Protocol Target Machine PLC Settings Serial Interface Flow Control DTR(ER)/CTS Transmission Speed 19200 bps Baud Rate 19200 bps Retry Count 2 Parity Bit Even Parity Bit EVEN Stop Bit 1 bit Stop Bit 1 bit Data Length 8 bits Data Length 8 bits Rcv Timeout 10 sec TX Wait Time 0 msec Serial Communication Use Setting Send Wait Time None Write possible in RUN mode Possible Checksum Yes Station No. 0 Station No. 0 Network No. 0 Network No. 0 PLC No. 255 PC No. 255 Request destination module I/O No. 1023 Request destination module station No. 0 11

RS-422 (4-wire) Flow Control Target Machine GP, PS-P PC/AT(PL), PS-G Serial Interface RS-422 (4-wire) *1 None Mode PLC Settings 5 (Format 5 Protocol mode) Transmission Speed 19200 bps Baud Rate 19200 bps Retry Count Parity Check YES Parity Bit Even Driver Parity Bit EVEN Stop Bit 2 bit Stop Bit 2 bit Data Length 8 bits Data Length 8 bits Rcv Timeout TX Wait Time 10 sec 0 msec Write possible in RUN mode Possible Checksum Yes Station No. 0 Station No. 0 Network No. 0 Network No. 0 PLC No. 255 PC No. 255 Protocol Request destination module I/O No. Request destination module station No. 1023 0 2 *1 By using a /RS-422(485) signal converter, you can use RS-422 connections with PC/AT(PL Series) and PS Series Type G target machines. In such a configuration, make sure you set the Driver s Serial Interface to. 12

6 I/O Manager Configuration The driver and protocol, which enable communication between the target machine and the PLC, depends on the PLC type. For information on how to display the [New Driver Interface] dialog box, see the online help. 13

7 Driver Configuration To configure the communication settings of the serial driver in the target machine, use the [Driver Configuration] dialog box. Make sure the settings match those of the PLC. For an overview of the driver and protocol settings, see Section 5 Environment Setup. For information on how to display the [Driver Configuration] dialog box, see the online help. Manufacturer Displays the name of the PLC manufacturer. Interface Displays the type of serial connection used to connect the target machine to the PLC. COM Port Defines which COM port to use on the target machine, for connecting to the PLC. Select COM1 for PS Series Type G target machines. Connection is not possible using COM2. Serial Interface Defines the serial connection: or RS-422 (4-wire). For details about the supported connections, see Section 2 Diagrams. Flow Control Defines the signals that control the data flow. Transmission Speed Sets the communication speed in bits per second. This setting must match the PLC baud rate. Retry Count Defines the number of times the driver tries to send or receive data when there is an error. Parity Bit Sets either a parity bit [Even or Odd] for use in detecting communication errors, or [None] at all. Stop Bit Defines the stop bit: 1, 1.5, or 2 bits. Data Length Defines the length of each unit of data: 7 bit or 8 bit. 14

Rcv. Timeout Defines the length of time the target machine waits for a response before it outputs a timeout error or sends another communication. TX Wait Time Defines the number of milliseconds that the target machine waits, after receiving a communication packet, before sending a response. 15

8 Protocol Configuration To set up details about the communication process between the target machine and the PLC, use the [Protocol Configuration] dialog box. For an overview of the driver and protocol settings, see Section 5 Environment Setup. For information on how to display the [Protocol Configuration] dialog box, see the online help. Station No. Enter a value to identify the PLC unit. (0-31) Network No. Enter a value to identify the PLC network. (0-239, or 254) PLC No. Enter a value to identify the PLC on the network. (0-64, or 255) Request destination module I/O No. Enter a value to identify the module. (0-511, or 1023) Request destination module station No. Enter a value to identify the module station number. (0 to 31) 16

9 Device Address Configuration To set up a PLC variable in the Variable List, use the Device Address Keypad from the variable properties. See Section 3 Supported Device Addresses. For information on how to display the Device Address Keypad, see the online help. Device Lists the PLC s discrete and word device types. Address Enter the device address for the PLC variable. The keypad ensures that you enter the correct format for bit and word devices. 17