rigel 288 Electrical Medical Safety Analyser Key Features Applications

Similar documents
277 Plus Electrical Medical Safety Analyser

Rigel Electrical Safety Analyser

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers

Date received into service; / /.

Rigel Instruction Manual 331A575 Issue 2.0. Hand-Held Electrical Safety Analyser. October Seaward Group Issue 2.0

Innovating together produces better biomedical test solutions. Innovating Together

Rigel Medical Product Brochure Medical Test Equipment. rigelmedical.com

LOW WEIGHT, SMALL SIZE,

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

The new ClareHAL Series. Keeping electrical products safe.

PrimeTest 250+ PrimeTest 250+ Users Professional PAT Testers Service Engineers Facilities Managers.

Apollo+ Series. Why buy the new Apollo+ Series? Apollo+ Series Users:

Portable Appliance Testing: Choosing the right tester for you

PRODUCT RANGE MEDICAL TEST EQUIPMENT FROM

The new Clare HAL Series. Keeping electrical products safe. Experts in what we do.

PRODUCT RANGE MEDICAL TEST EQUIPMENT FROM

ClareHAL 104 Electrical Safety Tester

METREL Measuring and Regulation Equipment

Pro Logger II. Designed and manufactured in Australia.

DeltaGT MI 3309 BT Instruction manual Ver. 1.4, Code no

TRANSMILLE PRODUCT GUIDE 2015/16 PROVIDING SOLUTIONS IN CALIBRATION WORLDWIDE. www. transmille.com

Electrical Safety Analyzers

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18

Seaward Supernova Elite

Operating Instructions

PAT-Cal 2 TECHNICAL MANUAL

ESA615 Electrical Safety Analyzer

MI 3360 OmegaPAT XA Technical info

Portable Appliance Tester KT75 OPERATORS MANUAL

Operating Instructions

GammaGT MI 3311 Instruction manual Ver. 2.0, Code no

MI 3360 OmegaGT XA Main features

A COMPACT GUIDE TO SAFETY TESTING: PROTECTION CLASSES

PAT300 Series Portable Appliance Testers User Manual

SigmaGT MI 3310 / MI 3310A Instruction Manual Version: 2.2, HW 2, Code no

Tried. Tested. Trusted. Rigel. Hand-Held SPO2 Simulator. Instruction Manual

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 1 Print Date February 2012 Date: 6/12 Revision/Date: 1 Page Count: 9

PROFESSIONAL, TOUGH ELECTRICAL LABEL PRINTING

AB MSAI Research Labs Pvt. Ltd., 201, IInd Floor, Aggarwal Cyber Plaza, Netaji Subhash Place, Pitampura, Delhi

Medical Device Testing Explained

Apollo 600 Table of Contents

Please use the Q & A utility to ask us any questions concerning the material being presented.

ATRT-03 S2. automatic, 3-phase transformer turns ratio tester

Solar Installation PV100 Operating Instructions

Features and Benefits

Rigel Multi-Flo. The infusion pump analyzer that can double your test capacity. Key Benefits n Double the test capacity per each channel

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

Spring 2014 FLUKE. Thermometer. Fluke VT04. Special promotions on all Fluke Multifunction Installation Testers. The Most Trusted Tools in the World.

Apollo 500. Table of Contents

PROFITEST INSTALLATION

Seaward Europa Plus. Portable Appliance Tester. Instruction Manual 302A550. December Seaward Electronic Ltd. Issue 2

Clare Safe Check 8. Electrical Safety Tester. Operating Manual. Instructions 309A550. November Clare Instruments Issue 2

MI 3394 CE MultiTester XA

Tri-Phase. true 3-phase transformer turns ratio tester

Dielectric Withstand and Ground Bond Testers

Seaward Supernova Plus

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Testing Instruments Manufactured by

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

EZCT-2000C Plus. current transformer test set. Vanguard Instruments Company, Inc.

TRF-250. automatic, 250V, 3-phase transformer ratio finder. Vanguard Instruments Company, Inc.

TRF-250A. automatic, 3-phase transformer turns ratio finder

ATRT-03B S2. automatic, 3-phase transformer turns ratio tester. Vanguard Instruments Company, Inc.

8100 SERIES ADVANCED 8.5 / 7.5 DIGIT MULTIMETER. www. transmille.com

Instructions 309A553. August Clare Instruments Issue 2

SL2400 Compact Monitor

Fully-Automated, Multi-Functional Electrical Safety Compliance Analyzers

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Operating Instructions

FULLTEST3 Rel ELECTRICAL SPECIFICATIONS Accuracy indicated as [ readings + (number of digits * resolution)] at 23 C 5 C <80 HR

CT-8000 S3. digital circuit breaker analyzer

3156 LEAK CURRENT HiTESTER

FULLTEST3 Rel of 11/11/14

User's Guide. Extech AM A AC Analog Clamp Meter

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

TRF-250. automatic, 3-phase transformer turns ratio finder

Fluke Connect Modules Technical Data

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

PRIMETEST PRIMETEST. Operating Instructions

CT-8000 S3 digital circuit breaker analyzer

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Clare Safetest Manufacturing (UK / Europe)

91370 SL2600 Compact Monitor

Micro-Ohmmeter Model 6292

MACROTESTG1 Innovative multifunction Earth Ground Resistance and Earth Resistivity tester with Touch-screen display

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

AS/NZS 3760:2003 Appliance Safety Testing Guide ELECTRICAL APPLIANCE & SAFETY TESTING. Dedicated to the Safety Testing Needs of Australia

PROFITEST. Testing Protective Measures MASTER TESTER INSTALLATION

EZCT-2000C current transformer test set

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Auto-Ohm 200 S3 / DMOM-200 S3 / DMOM-600 True DC Digital Micro-Ohmmeters

ELECTROM INSTRUMENTS

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

SigmaCheck. Fully Featured Eddy Current Conductivity Meter ET NDE

User s Guide. 600A AC Clamp Meter. Model 38387

vpad-mini Electrical Safety Analyzer Operating Manual

Advanced Test Equipment Rentals ATEC (2832)

Operating Instructions

Transcription:

rigel 288 Electrical Medical Safety Analyser Key Features Versatile Test in Accordance with the leakage requirements of IEC/EN 60601-1, AAMI and NFPA, IEC 62353 (VDE 0751-1) using separate IEC 60601 and AAMI Body Model Hand-held Using purpose designed robust enclosure, the Rigel 288 is truly hand-held, easy to hold single handedly and enables one hand operation and navigation Easy to use A full graphic, monochrome LCD display (1/4 VGA minimum) in combination with an integral alpha-numeric ABCD-key-board. Manual and Automatic test modes Able to perform UTS (Unique Test Sequence) and allows fully automatic, semi automatic and fully manual testing. The Rigel 288 is the FIRST universal truly hand-held medical electrical safety tester to combine the features of an automatic / manual tester with a data logging / asset management facility. A compact lightweight design and long life battery power reduces downtime between tests, making the instrument totally practical and highly portable for multi site use. In addition to IEC 60601-1 and AAMI / NFPA 99, the Rigel 288 tests to the new standard for in-service and after repair testing of medical electronic devices, currently drafted in as the IEC 62353. The Rigel 288 s large internal memory facilitates the storage of test results for safety audit and traceability purposes. Comprehensive database software is available to ensure fast and easy download of test results, managing your asset database, creation of test sequences, scheduling of Preventative Product Maintenance and producing test certificates. Wireless connection means that stored data can be transferred immediately and directly from the tester to PC-based record keeping systems at the touch of a button. The highly versatile Rigel 288 represents the next generation of electrical medical safety analysers. User definable test routines, Users have the ability to amend the default programs or create new programs by copying the preset test programs. Each program will have a unique Identifier. Multiple Applied Part function This feature gives the user the capability of testing up to 10 individual Applied Parts from different Modules or classes e.g. BF and CF class, or Bf ECG and Bf SPO2 module. Internal Asset management facilities Store up to 10,000 test records, custom test routines, visual inspections and performance tests and download to and from PC via Blue Tooth Interface. Applications Routine testing of Medical Electrical Equipment Service tool for Performance Testing Asset Management Fast and efficient testing of IEC leads Earth bond testing on (Medical) Installations and non Medical Equipment

The Market Place The market for hand-held medical safety testers is soon to change with the imminent introduction of a new standard for in-service and after-repair testing of medical electronic devices. The new standard is currently in draft as IEC 62353 and expected to become the general guideline for in-service / after-repair testing. At present, the IEC 60601-1 standard is used as a reference in many countries as local guidelines do not always exist for in-service and after-repair testing. The Rigel 288 combines the current IEC 60601-1 and AAMI/NFPA leakage requirements with the new IEC 62353. The Rigel 288 is the first hand-held tester to combine graphics with an alphanumeric keyboard and Blue Tooth connection to various peripherals such as RFID, Label Printer, barcode scanners, PDA's and PC's. This will allow for high flexibility in the field. Also Available from : Rigel 266 Plus Manual Safety Analyser Rigel 277 Plus Automatic Safety Analyser Rigel 311 NIBP Simulator Rigel 322 SPO2 Simulator Rigel 333 Patient Simulator Rigel 344 Defibrillator Tester Rigel 355 Ventilator Tester Rigel 601 Plus MediGuard Software Application Custom Test Settings The unique setup in the Rigel 288 not only allows you to configure your own test sequences or modify existing ones to suit your specific needs, the Rigel 288 also provides the unique feature to configure your own visual or acceptance test routines prior to an electrical safety test. These could be simple instructions to the user, observations required for your own maintenance procedures such as checking for certain labels, software versions and upgrades etc. In addition, you can configure post safety test procedures such as recording readings during a performance test on a patient monitor (SPO2, NIBP, ECG, Temperature, IBP etc), Defibrillators (Energy, Synch time, Charge time etc) and so on. These features make the Rigel 288 a truly versatile service tool to ensure all test data is captured and processed in one single test record thus maximising the traceability and allowing full flexibility in the field. Test n Tag Compatible Our Test n Tag system allows you to print customised Thermal PASS / FAIL Labels. The benefits of using the Test n Tag printer are: Robust and durable labels Resistant to most solvents used in the medical sector Free opportunity to advertise your logo and company details or emergency telephone number with every item you Test n Tag. Automatic barcode generation to provide easy use of the barcode scanner thus speeding up your test time. The unique test n tag label provides test status and retest due date, barcode and asset ID number, and person conducting the test. Also Available From the Seaward Group: Portable Appliance Testers IEC Lead Tester Insulation Resistance Testers RCD Testers Earth Loop Impedance Testers Installation Testers Multimeters Current Clamps Hipot Testers Earthbond Testers Micro Ohmmeters To find out more about these products, please; email: sales@rigelmedical.com, call: +44(0)191 5878730 or visit www.rigelmedical.com

Comprehensive PC Software The Rigel 288 is compatible with a new and comprehensive download software package capable of producing asset management records and work schedules. Use the software to configure a number of Rigel 288 s at the same time to ensure that all engineers work to the same test routines. Create customer test routines including test protocols for testing Patient Monitors (NIBP, SPO2, ECG etc.), Defibrillators etc. Test protocols can be easily uploaded to the Rigel 288 using either the blue tooth or RS 232 connection. Unique use of ICONS The Rigel 288 features a hi resolution graphic back lit display which not only provides highly visible and easy to follow menu structures but also allows the user to operate the tester using intuitive icons to speed up their test routines. Below are of some of the icons used in the Rigel 288: Use your Rigel 288 to collect readings during functional testing to collect not only the electrical safety test record but also the performance of the Medical Device. The complete PPM in one single record. Furthermore, the software allows you to produce certificates both via the printer and email to make sure test records are kept for future reference. Key Features 1. Windows Explorer type user interface - layout 2. Download from Rigel 288 to PC via BT or RS 232 3. Upload from PC to Rigel 288 via BT or RS 232 4. Create Test Routines and configure multiple testers 5. Output of database to Excel / Access. 6. Database function 7. Test schedule function 8. Printing of Test Certificate 9. Store Test certificate as HTML for easy email application Settings Print Help Edit Delete Save Rigel 288 Design Philosophy The Rigel 288 has been designed to address the increasing demand for smaller more comprehensive test equipment within the Healthcare Industry. What better way than to combine such tester with the new International In- Service Test required as per IEC 62353. The challenge was to combine the benefits of the size and weight of a smaller hand-held and portable Analyser with the test power and convenience of a larger bench-mounted automatic safety analyser. Today s industry demands test equipment that can save time and cost, thus offering greater flexibility. These factors have all been taken into account during the development of the Rigel 288. The test capabilities and functionality exceed that of most common bench mounted safety analysers yet the instrument is only a fraction of the size and weight. No other safety tester on the market offers a hand-held enclosure with the test capabilities of that of an automatic safety analyser; including IEC 60601 and IEC 62353 leakage tests, up to 10 Patient Connections, alpha numeric keyboard, graphic user interface, large internal memory, Blue Tooth communication, asset management facilities, user configurable Performance Tests and more. We believe that the new Rigel 288 is set to become the new standard in Electrical Medical Safety Testing. Patient Connection Single Fault Condition

SEAWARD GROUP FILES PATENT FOR NEW EARTH CONTINUITY TEST Seaward Group, parent company of has developed a new method of carrying out earth continuity tests undertaken as part of the process to verify the electrical safety of portable Medical and Domestic Appliances. The Seaward Group has filed a patent application for the new test technology that uses a dual current high intensity test to overcome contact resistance problems or other situations where weak conductor connections may inhibit protective earth testing with conventional test currents such as 1A or 200mA. The patent recognises that a 200mA test current is rapidly becoming the International Standard for in-service testing and testing after repair of Medical Electronic Equipment such as the imminent IEC 62353. However, the new concept has been specially designed to help overcome variations in measurement that can be caused by contact resistance between the test probe and the device under test, for example, when measuring continuity of tarnished or corroded parts often seen in the commonly used detachable IEC power cable. The unique technology introduced by Seaward Group enables valid earth continuity tests to be carried out using battery powered testers and is being incorporated into the new Rigel 288 hand held electrical medical safety analyser. The innovative new Rigel 288 has been specifically designed to provide a hand-held test solution for those demanding versatility and portability yet not compromising the validity of tests being carried out. The Rigel 288 meets the in-service and post-repair test demands of the IEC 60601 standard, as well as being prepared for the new IEC 62353 standard for in-service testing of Medical Devices. Electrical Safety Tests performed Earth bond* Insulation Specific to IEC 60601-1; Earth Leakage Enclosure Leakage Patient Leakage Patient Auxiliary Patient F-type Specific to pr IEC 62353 VDE 0751; Equipment Leakage (Direct, Differential and Alternative Method) Applied Part Leakage (Direct and Alternative Method) Specific to AAMI & NFPA; Patient Leakage AP-GND Patient Leakage AP-CASE Patient Leakage AP- AP Patient Leakage AP- ALL (AAMI / NFPA) Custom tests can be created using a variation or combination of the above. * Using unique patented technology proving hi-current (>25A) test capability

RIGEL 288 SPECIFICATIONS Earth Continuity Method 2 wire technique, using 'zero' lead function. Test Current >+200mA, -200mA DC into 2 ohms Max Test Voltage 4-24V rms o/c (6V for IEC 60601 tests) Measuring Range (low range) 0.001 0.999 ohms @ 0.001 ohms resolution Measuring Range (mid range) 1.00 9.99 ohms /@ 0.01 ohms resolution Measuring Range (high range) 10.0 19.9 ohms @ 0.1 ohms resolution ± 3% of reading + 10 m ohms Insulation Resistance Measurement EUT to Earth / Ground, EUT to AP, AP to Ground Voltage 250V DC, 500 V DC @1mA. Range (low range) 0.01Mohms - 20 Mohms (low range) ± 5% of reading +2 counts Range (high range) 20Mohms 100Mohms (high range) ±10% +2 counts Resolution 0.01Mohms Direct Leakage Measurement Measuring Range 4µA to 9999µA ± 5% or reading +2 counts Mains on A.P. voltage F-type only @ 110% of mains Measuring Device As per IEC 60601-1 requirements Measurement Type Separate AC & DC for Patient (-Auxiliary) Leakage to IEC 60601 True RMS for all remaining Leakage tests Benefits The Rigel 288 is a small comprehensive electrical safety analyser and is designed to comply with IEC 60601-1, AAMI / NFPA-99 and IEC 62353. The Rigel 288 has been designed with the customer s requirements in mind, offering the tests and usability they need. It is the right product at the right time. The Rigel 288 is the smallest and lightest comprehensive electrical safety analszer on the market making it easier to work effectively across multiple sites. Upgradeable to meet test requirements. The customer only pays for what they need. Rigel 288 includes: Calibration Certificate Carrying Case Earth bond test probe with clip Earth bond clip lead Patient Applied part module 10 Applied part adaptors Detachable 2 meter mains cable Blue Tooth USB dongle Electronic Instruction Manual Removable quick start card Differential Leakage Measurement Measuring Range 75µA to 9999µA ±5% of reading + 5 counts Measurement / display resolution1µa Measurement Type True RMS Measuring Device Similar frequency response characteristics to IEC 60601-1. Alternative Leakage Measurements: Test Voltage 250V at mains frequency Test Current 3.5 ma current limited Measurement Range 4µA to 9999µA Measurement Resolution 1µA Measurement ±5% of reading + 2 counts Measurement Type True RMS Measuring Device As per IEC 60601-1 Rigel Peterlee, SR8 2SW Tel: +44 (0) 191 5863511

RIGEL 288 SPECIFICATIONS Power Measurement Method VA rating. Range 0.1KVA 4KVA ±10% + 2 counts How to Order UK/Ireland version Euro/Schuko version French version Danish version Czech / Polish version USA version (110V 60Hz) Australian version 331A910 331A910 331A917 331A915 331A918 331A914 331A912 Mains Outlet Test Input voltage range: 0-300V AC, max current 16A Measures L E, N E & L N ± 5% of reading + 2 counts IEC Mains Lead Test Test Duration: 2s Test: Continuity of all conductors, Earth bond, Insulation & Polarity General Mains power 230 VAC ±10%, 50Hz +/- 1Hz 120 VAC ±10%, 60Hz +/- 1Hz (USA model) Battery 6 x 1.5V Alkaline AA Weights 1.6 kg including batteries Size (L x W x D) 270 x 110 x 75 mm / 10.5 x 4 x 3 Operating conditions 0' - 40'C, 0-90% RH - NC Storage environment -15' - +60'C Environmental Protection IP 40 Other variants available upon request Accessories: PC Download software Barcode scanner with embedded Blue Tooth Blue Tooth Test N Tag System Brain Cell Read / Write Scanner with embedded BlueTooth Download software for PDA (please check for availability) Blue Tooth Serial Adaptor Shipping Information: Packaging Weight Size Related Interest Rigel 266 Plus Rigel 277 Plus IEC 62353 Booklet IEC 60601 Booklet Corrugated cardboard box 3.4kg 410*290*220mm SEAWARD GROUP WORLD LEADERs IN SAFETY TEST AND MEASUREMENT Web: www.cropico.com Email: info@cropico.com FREE IEC GUIDES Cropico A PRACTICAL GUIDE TO IEC60601 Seaward test and measurement companies include: Hampton Road, CLARE Croydon, INDUSTRIAL SAFETY INSTRUMENTS CROPICO Surrey, United Kingdom, CR9 2RU PRECISION INSTRUMENTS Tel: +44 (0) 20 86844025 Fax: +44 (0) 20 86844094 A PRACTICAL GUIDE TO IEC62353 Available online www.rigelmedical.com RIGEL MEDICAL SEAWARD PORTABLE ELECTRICAL SAFETY INSTRUMENTS