MiCOM Alstom P14N, P14D, P94V

Similar documents
Agile P24xM. Grid Solutions. Protection and Control. Motor Management Series. Metering and Monitoring. Advanced Communications.

GRID/PRSHT/MU320/EN/1.2014/GBR/1894 ALSTOM All rights reserved.

MiCOM P14x AREVA T&D. Feeder Management Relays

MiCOM P14x. Feeder Management Relays

MiCOM P521. Fast feeder differential protection

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

MiCOM P521. Fast Feeder Differential Protection

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

Substation Automation Products. Line differential protection RED670 Relion 670 series

MiCOM P14x. Feeder Management Relays. Protection Relays

MiCOM Agile P541 & 542. Grid Solutions. High-speed current differential unit protection. Key Benefits. Key Features. Current Differential Protection

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

GE Multilin 350 Feeder Protection Relay Specifications

Content REF615 Technical Presentation

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

SOLKOR-N (7SR18) Feeder Differential Protection. Make the ight choice! Choose EYROLLE Protection

Current Matters. The Device issue. Siemens Protection Devices Ltd. In-depth looks at some of our best and most versatile products to date

Power systems 5: Protection

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

MiCOM P122C Time-Overcurrent Protection

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

MiCOM Agile P345 & P348

Three phase and earth fault overcurrent relays

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Products Portfolio. Pole mounted Vacuum Recloser

Protection and Control REX640 Product Presentation

Protection relays.

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

MiCOM P12x/y. Three phase and earth fault overcurrent relays

MMLG 01, 02, 03, 04 MMLB01

MiCOM P12x/y AREVA T&D. Three phase and earth fault overcurrent relays

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Earth-fault Relay SPAJ 110 C. Product Guide

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

(1) Description of Operation 7SR224 Recloser Controller

MiCOM Agile P642, P643, P645

MiCOM Agile P543-P546

Feeder/ Motor Protection Relay VAMP 40

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Perfect protection smallest space

TWO-WINDING TRANSFORMER DIFFERENTIAL

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Feeder protection relay SPAA 121 C. Product Guide

Equipment Strategy For High Voltage Circuit Breakers

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Bus Bar Protection Relay B-PRO 4000

MiCOM P220, P225 and P226C

Substation automation products. MicroSCADA Pro for substation automation

MiCOM P111. Three phase and earth fault overcurrent relays

ELG4125: System Protection

Benefits, offering and references

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

THE INTEGRATED TESTING SOLUTION

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Maximize protection. Sepam series 10, 20, 40, 60, 80. Modular range of digital protection relays

7SR21 & 7SR22 Argus Overcurrent Relay Energy Management

VIP 40/45 VIP 400/410

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Feeder Protection REF615 Ver Technical Presentation. ABB Oy Distribution Automation. Prashant Ganoo Regional Product Marketing Manager

Power Systems Communications Implementation of IEC61850 in a Substation Environment

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

Siprotec 7ST61 / 7ST63

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

Modular Smart Grid Power Systems Simulators (Utilities)

Product Families and Positioning. Protection Portfolio

Application Notes on Generator Protection Schemes

ABB Inc. Instructions REF 550 Advanced Feeder Protection System

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

7SR11 and 7SR12 Description of Operation

7SR11 & 7SR12 Argus Overcurrent Relay Energy Management

Mics KERYS FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS KER/GB-2004/1

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

SEL Time-Domain Link (TiDL ) Technology

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

TFS 2100 Traveling Wave Fault Location System

Protective Relays & SCADA Systems

Content FPC 400. USER MANUAL Apr Feeder F3 Motor M4 Busbar B3 Transformer T4

A low-cost, economical solution for distribution feeder protection

Electrical Integration with Smart Communication

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

RELAYABLE POWER. AQ-200 series protection, control, measurement and monitoring IEDs

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

Digital Substation Unrestricted Siemens AG 2017 siemens.com/digital-substation

MiCOM P13x AREVA T&D. Feeder Management Relays

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Transcription:

MiCOM Alstom P14N, P14D, P94V The P14N non-directional feeder, P14D directional feeder and P94V voltage & frequency IEDs bring the design rigour and technology of transmission applications to the entire utility and industrial market. P40 Agile feeder management IEDs The footprints of both the device physical size and the lifecycle environmental impact have been minimised using state-of-the-art design, component, and process selection. Agile solutions from Alstom are ideal for new-build and retrofit alike. AGILITY, VERSATILITY MiCOM P40 Agile IEDs provide an integrated solution for the complete protection, control and monitoring of electrical power systems. Application for overhead lines, underground cables, busbars, breakers, transformers, reactors, distributed generation and motors is supported, right from distribution (as primary protection) to transmission voltage levels (as back-up). The IEDs are suitable for application in solidly-earthed, resistance-earthed and Petersen coil systems alike. THE PERFECT BALANCE: STANDARDISED AND ADAPTABLE With a wide range of protection functions as standard, MiCOM P14N, P14D and P94V IEDs also offer additional pre-configured applications for smaller generators and a choice of functionality applicable to overhead lines. This allows the user to conveniently scale the application, which is then readily adapted via simple enable/disable feature selection in the configuration menu. The IEDs offer a universal wide-range power supply, universal 1 A/5 A CT inputs (software selectable), and universal binary inputs the latter with programmable pickup thresholds. Harmonisation at just one ordering option is often possible, easing the task of creating standard cubicle designs and strategic spares holding. CUSTOMER BENEFITS Novel Draw-out Versatile Powerful logic, protection and communications Cost effective IEC 61850 and DNP3 Ethernet solution High impedance downed conductor element boosts the safety of the public and livestock Alstom s user-centric access tool S1 Agile used as the single PC tool for all MiCOM NERC compliant cyber security (1) Only with sensitive earth fault CT option (2) HIF high impedance (downed conductor) fault Grid-SAS-L3-Agile-2759-2014_11-EN. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper.

FUNCTIONAL OVERVIEW The numbers in the table denote the number of elements or stages available

MICOM ALSTOM P14N, P14D, P94V INTUITIVE USER INTERFACES The front-panel interface (shown in Figure 1) allows direct IED interaction. A USB front port offers enhanced access by laptop computers. Integrated user function keys and tri-colour programmable LEDs provide a cost-effective solution for control and annunciation. Numerous, optional, modern communication protocols, including IEC 61850, ensure interfacing to upper-level Supervisory, Control, Automation or Data Acquisition systems. FIGURE 1 P40 Agile front panel interface Slot-in user labelling 30TE (MiDOS SIZE 6) Additonal four tri-colour programmable LEDs Function keys with tricolour status LEDs ENVIRONMENTAL RESPONSIBILITY The IEDs are manufactured in a lead-free soldering process using lead-free components. Power dissipation is the lowest among comparable products, easing concern on station batteries. Even the product weight (including packaging) has been optimised to lessen the transit carbon footprint. All such actions boost the ecoresponsibility demonstrated in the Product Environment Profile (PEP). The product does not require any resident battery. CYBER-SECURITY The sophistication of protection schemes, coupled with the advancement of technology, increasingly leads to devices and substations being interconnected with open networks, such as the internet or corporate-wide networks. This introduces a potential security risk making the grid vulnerable to cyberattack, which could in turn lead to electrical outage. To secure communication within such environments, MiCOM P14N, P14D and P94V offer NERC-compliant cyber security. ASSET LIFE EXTENSION In addition to new-build, P40 Agile IEDs can be used to refurbish legacy protection schemes. As MiCOM P14N and P14D are pin-to-pin compatible with KCGG14x and KCEG14x respectively, they can simply be plugged-in to the K relay cases for an easy upgrade. This draw-out and substitute strategy dramatically reduces the refurbishment time and cost. HARDWARE All models offer: Space-saving 4U height and 20TE (4 ) or 30TE (6 ) case sizes A front USB port and a rear RS485 port Power-up diagnostics and continuous self-monitoring Wide choice of opto-isolated binary inputs and output relays N/O (form A) and N/C (form B) watchdog contacts The PEP shows claims for raw material depletion, energy depletion, water depletion, global warming potential, ozone depletion, photochemical ozone creation, air acidification, and hazardous waste production. QUALITY BUILT-IN Quality Built-In methodology is applied throughout the development and manufacturing of the IEDs. Parts stress analysis in R&D, rigorous component supplier selection, and a shipping carton compliant with ISTA protection requirements all are examples of best-practice to maximise long-life reliability. All circuit boards have harsh environmental coating, to resist moisture, salt, corrosive atmosphere and industrial ambient pollution as standard. Circuit board production uses in-circuit tests, boundary scanning, built-in self-test, automated optical inspection, and X-ray scanning to achieve maximum test coverage. Figure 2 depicts the software scalability of models, within the overall superset of the range functionality. The strong P40 family identity offers high customer familiarity, with minimal training requirements. FIGURE 2 P40 Agile application scalability

FIGURE 3 Example P40 Agile standard hardware (P14D) HARDWARE OVERVIEW *Ethernet models will have 8DI / 8DO

MICOM ALSTOM P14N, P14D, P94V PROTECTS ASSETS, PROTECTS PERSONNEL, PROTECTS THE PUBLIC, PROTECTS THE ENVIRONMENT 30TE models can accommodate: An optional IRIG-B port for time synchronising An additional RS485/K-Bus port An optional Ethernet port for IEC 61850 or DNP3.0 protocol Optional additional binary I/O: 5 inputs/4 outputs, or 3 inputs/4 outputs (for H7 TCS schemes) - model dependent The profile can be chosen to optimise the protection, without constraining the feeder s loadability. If a standard curve is not suitable for the application, the user can program and upload a custom variant. There are two standard earth fault elements, each with four independent stages. The first is the EF1 Measured element which operates from the quantity flowing directly into the relay s earth (IN) input. The second standard earth fault element (EF2) operates from a residual current that is derived internally by a mathematical summation of the three phase currents. The sensitive earth fault (SEF) order option fits a sensitive CT, designed for systems whose earth fault current is constrained. A core balance CT should be used to drive this SEF CT input. FIGURE 4 Example hardware options available in case size 30TE All CT connections have integral shorting, when the IED is withdrawn from the case. This affords additional safety to personnel who may be working near live apparatus. FEEDER PROTECTION Ethernet, graphical programmable logic and proven protection, measurement and control algorithms from Alstom s modular MiCOM P40 are native in the new range. Phase and Earth Fault Overcurrent Six independent stages are available for each phase overcurrent element. In addition to definite time and predefined IDMT curve selection, P14N and P14D support user programmable curves for customised operation and resetting. FIGURE 5 IEC and ANSI/IEEE inverse-time curve profiles

Special applications Load encroachment (blinder), cold load pick-up logic, second harmonic inrush blocking, broken conductor protection, RMS thermal overload protection, wattmetric earth fault, fault locator, auto reclose and check synchronising are built-in. High Impedance Earth Fault (HIF) Innovative high impedance earth fault algorithms improve the detection of downed conductors which have fallen on surfaces with high resistivity (eg. sand, dry scrubland, trees). This helps the utility to save human lives, protect nearby animals and lessen the risk of vegetation fires caused by prolonged arcing. Prior to the advent of HIF, such faults may not have been detectable by conventional earth fault methods, due to the extremely low and/or sporadic current flow. Wattmetric Directional Earthfault (WDE) An earth fault in an unearthed 3-phase system causes the phase voltage in the other two phases to increase. This in turn will cause arcing at the fault location. Many distribution systems use a Peterson coil to compensate, thus eliminating the arcing problem. The introduction of a Peterson coil creates difficulties for determining the direction of the fault. Standard directionalising techniques used by conventional feeder protection devices are not adequate. Wattmetric Directional Earthfault (WDE) is used in this scenario to protect compensated networks. DISTRIBUTED GENERATION PROTECTION Voltage controlled and voltage restrained overcurrent Voltage-dependent protection boosts sensitivity and reduces tripping times for faults on weaker systems, such as those with a high prevalence of distributed generation. The timing characteristic can be set as either definite time or IDMT. Power Two stages of power protection are provided and each stage can be independently configured to operate as over power or under power, forward or reverse directional and active or reactive. Two stages of sensitive power protection are provided and these can be independently selected as reverse power, over power or low forward power. FIGURE 6 Typical current waveform trace recorded for a downed conductor The wide range of setting options permits application of any frequency based load shedding or islanding scheme. Four stages of rate of change of voltage protection elements are also available, which offer an alternative approach to implement load-shedding schemes. LOGIC AND CONTROL CAPABILITIES All aspects of MiCOM P40, and MiCOM P40 Agile IED configuration are managed using the MiCOM S1 Agile software. Under / Over voltage Under/over voltage protection may be configured to operate from either phase-phase or phase-neutral quantities. Three independent stages with definite time elements are available; one of the stages can also be configured with an inverse characteristic. Check synchronising The check synchronising feature has predictive close control, to ensure that the CB contacts touch at the instant of synchronism, minimising the stress on plant assets when parallelling. TRANSFORMER PROTECTION P14N and P14D devices offer the required current protection with second harmonic blocking, thermal overload protection and instantaneous restricted earth fault element (REF). REF detects transformer winding earth faults, and may be configured as high impedance or low impedance biased differential. Negative sequence overcurrent protection can be set non-directional or directional (forward/reverse) and offers detection of remote phase-phase and phase earth faults BUSBAR PROTECTION Phase fault over current can be applied in a high impedance differential protection scheme for busbars, fitted with external stabilising resistors and non-linear resistors (Metrosils). Alternatively, a peer-to-peer hard-wired or Ethernet scheme can achieve blocked overcurrent unit protection for busbars. LOAD SHEDDING AND RESTORATION Nine stages each of frequency protection are available (except P14N). Each may measure in over-, under-, rate of change, frequency supervised rate of change or average rate of change mode. FIGURE 7 MiCOM S1 Agile: a powerful and intuitive PC-toolsuite Circuit breaker control Circuit breaker control is available from the front panel user interface, optically isolated inputs and remotely via the substation communications. Three function keys are available for direct actions instigated by users. The F-keys operate in two modes, normal and toggled, and activate associated signals in PSL that are used to customise the application or operative mode.

MICOM ALSTOM P14N, P14D, P94V Programmable Scheme Logic (PSL) Powerful graphical logic allows the user to customise the protection and control functions. It is also used to program the optically isolated inputs, relay outputs and LEDs. The logic includes OR, AND and MAJORITY gates, timers, and set/reset latch functions, with the ability to invert the inputs and outputs, and provide feedback. The PSL imposes no delay on logic throughput, using concurrent processing being used instead of sequential equations and avoiding any logic race issues. FIGURE 8 Programmable Scheme Logic SUPERVISORY AND CONDITION MONITORING FUNCTIONS Depending on the hardware base, two stage circuit breaker failure protection, CT / VT supervision, circuit breaker condition monitoring and trip circuit supervision are available. Supervision of the trip circuit in both circuit breaker open and closed states can be realised using the optically isolated inputs and programmable scheme logic. Full compliance to the benchmark H7 supervision scheme is available as a hardware option. MEASUREMENTS, RECORDING, AND POST-FAULT ANALYSIS All events, fault and disturbance records are time tagged to a resolution of 1ms. Up to 2048 time-tagged event records are stored in the flash memory and can be extracted using the communication ports or viewed on the front panel display. Records of the last 10 faults are stored in the flash memory. The internal disturbance recorder has up to 9 analogue channels, 32 digital channels and 1 time channel. The memory capacity is approximately 50 records for a typical 0.5 s duration. The measurements provided, which may be viewed in primary or secondary values, can be accessed via the front panel LCD display, or the communications ports. LOCAL AND REMOTE COMMUNICATIONS Two communication ports are standard: a rear port providing remote communications and a front port for substation staff. The front USB port allows the programming of settings, configuration of the programmable scheme logic, extraction and viewing of event, disturbance and fault records, viewing of measurements and the instigation of control functions. Any of the protocols listed below can be chosen at the time of ordering: Courier / K-Bus Modbus IEC 60870-5-103 DNP 3.0 (RS485 serial or Ethernet) IEC 61850 (100 Mbit/s Ethernet) IEC 61850 or DNP 3.0 over Ethernet are available when the optional Ethernet port is ordered in 30TE models. The copper physical link option uses RJ45 connectors, the fibre option uses LC connectors. IEC 61850 offers highspeed data exchange, peer-to-peer communication, reporting, disturbance record extraction and time synchronisation. MiCOM P40 Agile offers 32 virtual inputs, and best-in-class GOOSE performance. An optional second rear Courier port is available, designed typically for local engineering workstation access, or for dial-up modem access when the main port is reserved for SCADA. THE INCLUSION OF FUNCTION KEYS, ANCILLARY SUPERVISION AND TRI-COLOUR LED ANNUNCIATION SAVES CUBICLE SPACE

MICOM ALSTOM P14N, P14D, P94V For more information please contact Alstom Grid: Alstom Grid Worldwide Contact Centre www.alstom.com/grid/contactcentre/ Phone: +44 (0) 1785 250 070 MiCOM P40 Agile: Novel Draw-out Versatile Visit us online: www.alstom.com Grid-SAS-L3-Agile-2759-2014_11-EN. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper.