masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08

Similar documents
OPERATIONAL MANUAL FOR 85XX

Operator s Manual. masibus

Masibus Automation And Instrumentation Pvt. Ltd.

SINGLE-CHANNEL PROCESS INDICATOR series 8001

/8 DIN Universal Process Indicator

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Tempco Instruction Manual

Wall-/Pipe Mounted Universal Process Indicator

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

HART UNIVERSAL TEMPERATURE TRANSMITTER

masibus DIGITAL CONTROLLER 5002U Ref No: m55a/om/101 Issue No: 08 Operator s Manual Operator s Manual Page 1 of 20

STA SIL 2 and SIL 3 Capable Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

Trident and Trident X2 Digital Process and Temperature Panel Meter

C160 Wall-/Pipe Mounted Universal Process Indicator

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

/8 DIN Motorized Valve Controller

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Model No Universal Input Indicator Start-up Guide

HART UNIVERSAL TEMPERATURE TRANSMITTER

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

DIGITAL PROCESS CONTROLLER

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Trident & Trident X2 PD765

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Temperature/Process Controllers Manual

Model 620A Maintenance and Calibration

CDD4 Duct Carbon Dioxide Transmitter

CARLO GAVAZZI Automation Components

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

UNIVERSAL TEMPERATURE TRANSMITTER

100mm Process Indicator Recorder

Temperature, Process &

Contents. Temperature & Process Measurement Indicators Setup Guide

IN-uP4 Universal Input Indicator.

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

CHAPTER 1. Introduction Introduction 3

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

SX90 Process Controller

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Intrinsically Safe Temperature Concentrator System

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

IN-uP4 (Rev 1) Universal Input Indicator, Panel Mount.

CONTENTS. Chapter 1...Description. Chapter 2...Installation. Chapter 3...Operation. Chapter 4...Calibration. Chapter 5...

CDD Carbon Dioxide Transmitter

DPR 100 A/B Analog Scales

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

From lab to production, providing a window into the process. Universal Input Indicator Start-up Guide. Operating Manual.

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

Temperature Meter Model Instruction Manual

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

LE ELECTRONICS Pvt. Ltd.

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

CDD4 Series Room CO2 Transmitter Installation Instructions

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

LBVR1718. Description. Features channel paperless recorder

ControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

ProSense DPM2 Series. Digital Panel Meter. User Manual. for process, temperature and resistance input signals. Models: DPM2-AT-HL DPM2-AT-2R-HL

dual-line 6-dIGIt process MeteR

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

LAUREL ELECTRONICS, INC.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

DUAL-LINE TEMPERATURE METER

Digital Panel Meters Modular signal s conditioner Type USC-DIN

The CAL range of temperature controllers

Modular Panel Meter Series EDM 35

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

L40 UNIVERSAL ANALOG INPUT DIGITAL PANEL METER OWNERS MANUAL

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

P/N /02 Rev. C ECO # Model 1440 Microprocessor-based Temperature Controller Installation and Operation Manual

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

iothinx 4500 Series (45MR) Modules

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Specification for temperature sensor calibration setup

LCI User Manual mantracourt.com

Omni + User Manual. Dual Setpoint Temperature Controller with Programmable Input & TIMER. Omni 96+ Omni 72+ Omni 48+ TMR TMR TMR

Temperature Measurement

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Universal Process Controller

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

Temperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S

ControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

UNIVERSAL PROCESS INDICATOR / CONTROLLER Model No. : UT-102

Control instruments GUARDIAN 2 - GUARDIAN 3

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

4511 MODBUS RTU. Configuration Manual. Universal trip amplifier. No. 4131MCM100(1402)

Transcription:

INTRODUCTION This is a micro-controller based Universal Transmitter which retransmits the Universal Inputs given, into the required Voltage or current. This instrument provides isolation at 4 levels: (a) (b) (c) (d) SPECIFICATIONS MODEL TYPE DISPLAY Between input and Power supply Between output and Power supply. Between input and output. Output to Output. : DISPLAY SCALING:-1999 to 9999 : Universal Transmitter with Dual Retransmission Output. : 4 digit, 0.3", 7- segment red LED DISPLAY RANGE : RTD : -199.9 TO 850.0 C Linear : -1999 to 9999 (selectable) T/C : as per sensor KEYS NO. OF INPUT : 3 Keys (ENT, SEL & ESC) : One I/P TYPES : - T/C : E, J, K, T, B, R, S, N RTD : Pt100, 3-WIRE Linear : -10-20mV, 0-100mV, 0-2V, 0.4-2V, 0-5V, 0-20mA, 1-5V, 4-20 ma, 0-10 VDC I/P ACCURACY : ± 0.1% of Full Scale. I/P RESOLUTION : As Per Input table. RESPONSE TIME : 75 msec. LINEARIZATION METHOD : Through Software, using 9 th order Coefficients. NO OF OUTPUTS : Two (O/P-2 is Optional). O/P TYPES : 4-20mA, 0-20mA, 1-5V, 0-5V, 0-10VDC (At a time Either Voltage or Current o/p will be provided for each channel, that will be factory set) CALIBRATION COLD JUNCTION : Through Front panel COMPENSATION : By software. OVER RANGE O/P : 5% above F.S. (Not applicable for Voltage Inputs) PROTECTION CMRR NMRR THERMOCOUPLE BURN OUT OPERATING SUPPLY : Short ckt. & Open ckt. (At output) : > 120 db : > 50 db POWER CONSUMPTION: < 10 W ISOLATION ISOLATION LEVEL MOUNTING DIMENSION OPERATING TEMPERATURE OPERATING RH Dimensions 55 mm : (Programmable scaling) : 85-265 VAC or 18-30 VDC (Optional). : Three port isolation I.e. between input/ output/ power supply. : 1500 VAC/ 500VDC@2000 Mega ohms between input, outputs and power supply : DIN Rail : 55 (W) x 75 (H) x 110 (D) mm : 0 to 55 deg C : 40 to 95 % RH Non condensing O/P LOAD O/P ACCURACY NO. OF RELAY OUTPUT (Optional) RELAY RATING : 750 Ohms max (For Current O/Ps) 4000Ohms min (For Voltage O/Ps) : ± 0.25% of Full Scale. : Two : 2A/230VAC TRANSMITTED POWER SUPPLY : 24VDC @ 30 ma, with Short circuit Protection Page 1 of 6

Front Panel ENTER / SCROLL Key This key is used to start menu, scroll through the menu and save values. SEL / SHIFT Key This key is used to select the menu options, for shifting the digit of the selected parameters and for Ambient display in Run Mode for TC Input. ESC / INC/ ACKNOWLEDGEMENT Key Menu Function List PROG ST-1 HY-1 0 TO 100 ST-2 HY-2 0 TO 100 This key is used to revert back to the parent menu from the sub menu levels and Increment the selected digit. This key is also used as Acknowledgement key for Alarm/trip type relay. Set point value for relay-1 Set point value for relay-2 T/C: E, J, K, T, B, R, S, N. CONF RTD: Pt100 3-WIRE. IPTY Linear: -10-20mV, 0-100mV, 0-2V, 0.4-2V, 0-5V, 0-20mA, 1-5V, 4-20, 0-10V. INP Zero Input Zero Value Span Input Span Value DP 0-3 UNIT C, F, K OUT rtr OPNO 1, 2 4 20mA, 0 20mA, 1-5V, 0-5V, OPTY 0-10VDC * Percentage of Output OPLO (O/P Low limit will be limited to this configured 0-25 % of O/P Span) * Percentage of output (O/P Hi limit will be limited to OPHI this configured 75-100 % of O/P Span) rely Page 2 of 6 CAL ADV AMB OPSC UPSC/DNSC DIR DIR/REV RLNO 1, 2 OPSE UP,dw LOGC HI,low C AL ALARM,,OPEN LTCH YES,NO FILT 0-60 Sec FSET Give Default password for factory settings PASS Change Password SQRT YES/NO TOUT 10-300 SEC SPAN INP ZERO OPNO 1, 2 OUT ZERO SPAN VER 1 UT1.1 * Output will not be scaled but only limit to this configured % of output. Parameter Description CONF CALI INP OUT ADV VER AMB IPTY Zero Span DP UNIT OPNO OPTY OPLO OPHI OPSC DIR FILT FSET PASS SQRT TOUT Configuration Mode Calibration Mode Input type Parameter Settings Output type Parameter Settings Advance Parameter Settings Software Version Ambient Input Type Input Zero Input Span Decimal Point Engineering Units Output Channel No Output Type * Percentage of the O/P Zero range * Percentage of the O/P Span range Up/down Scale one sensor open Forward/Reverse Output Digital Filter Factory Setting Password Square root Time out From the Menu (10 to 300 Sec)

OVER UNDR OPEN WAIT CERR SERR AERR Ferr rely RLNO OPSE LOGC C AL LTCH rtr ST-1 HY-1 ST-2 HY-2 Input Ranges Input Signal Above Span Input Signal Below Zero Sensor Burned Calibration In Process Error in Calibration Setting Error ADC Error Factory setting Error Relay Relay number Open sensor Relay control Logic Configure alarm Latch Retransmission Set point for relay one Hysteresis for Relay one Set point for Relay two Hysteresis for Relay two Input Range Resolution E TC -200 to 1000 C # 0.1 C J TC -200 to 1200 C # 0.1 C K TC -200 to 1370 C # 0.1 C T TC -200 to 400 C 0.1 C B TC 450 to 1820 C 1 C R TC 0 to 1750 C 1 C S TC 0 to 1750 C 1 C N TC -200 to 1300 C # 0.1 C RTD Pt100-200 TO 850 C 0.1 C -10 to 20 mv -1999 to 9999 Counts 1 Count 0 to 100 mv -1999 to 9999 Counts 1 Count 0 to 2 V -1999 to 9999 Counts 1 Count 0.4 to 2 V -1999 to 9999 Counts 1 Count * 0 to 20 ma -1999 to 9999 Counts 1 Count * 4 to 20 ma -1999 to 9999 Counts 1 Count 0 to 5 V -1999 to 9999 Counts 1 Count 1 to 5 V -1999 to 9999 Counts 1 Count 0 to 10 V -1999 to 9999 Counts 1 Count Note : # Resolution 1 C After 999.9 C. * Connect 100R 0.1% Resistance at I/P. Page 3 of 6 Using Menu To enter into the menu mode, Press the ENT key. Display will show PASS and asking for password.. Press SEL key to enter password. Display will show 0000. Now press SEL key to edit password. Now last digit will start blinking. Now edit password digit by INC (ESC). In this case pressing SEL (SHIFT) key will shift the blinking to the next digit. Press ENT key to give password. o If password is correct, then display will be steady instead of blinking. Press ENT key to enter in menu mode. o If password is wrong then unit will directly enter in RUN mode. Scroll through the menu options using the ENT Key Prog, Conf, Cal and Ver1. Select the option by pressing the SEL key. Scroll the sub menu options using ENT key. Select the particular option by pressing the SEL key. Use the ESC key to exit from the submenu, back to the parent menu levels. To change the displayed value, press the SEL key again. Now according to the option selected, o o If it s a text message the whole display blinks together Else if it s a numeric value the first digit starts blink. In this case pressing SEL (SHIFT) key will shift the blinking to the next digit. Change the display settings using INC (ESC) key and SHIFT (SEL) key. Press the ENT key to save the setting. Press the ESC key and you will be in the parent menu option. Program Menu Set point for relay-1. Hysteresis for relay-1.(0-100) Set point for relay -2. Hysteresis for relay-2.(0-100) Configuration Menu Input Selection Input Type Selection Input Zero Setting Input Span Setting Decimal Point Setting (Only for Linear Inputs) Engineering Unit Setting ( C, F or K, only for TC and RTD inputs) Output Selection 1. Retransmission:- Output Channel Selection for Setting (1 or 2) Output Type Selection (0 20 ma, 4-20 ma, 0-5 V, 1-5 V, 0 10 V that will be provided as factory setting) Output Low Setting (Minimum 0.0 25.0 %) Output High Setting (Maximum 75.0-100.0 %) Output Upscale / Downscale Setting for OPEN input Output direction Setting (Direct / Reverse) 2. Relay:- Relay No. Selection for Setting purpose (1 or 2) Relay Upscale / Downscale Setting for OPEN input Selection for Operating relay above (high) or below (low) set point. Selection of relay type i.e. Alarm or Trip or Open Latch selection whether Latch yes or No Latch only if alarm type relay is selected. Refer Table no. 1 for detailed relay logic.

Advance Options Digital filtering (Range: 0 to 60.0 second) Factory Setting- To retrieve the factory setting. Password Setting Square Root (No / YES, for Linear inputs only) For Square Root, Output will be come as per PV = SQRT[ { (input reading config. IP Zero) / (config. IP Span Config. IP Zero) } * Config. OP Span ] + Config. OP Zero Time Setting for Come back to RUN mode on no key operation (Range: 10 to 300 second) Calibration Menu Ambient Calibration (For TC only) Input Calibration o Input Zero Calibration (For RTD only) o Input Span Calibration Output Calibration o Output Channel Selection for calibration o Output Zero Calibration o Output Span Calibration Software Version o Version Number of the Software Calibration Procedure Calibration for the unit is to be carried out by an experienced engineer only. Reference used for the calibration should be of high accuracy (0.1% better) and good stability. After Giving correct Password Press the Enter Key to enter into the menu levels (Scroll along using the Enter Key itself. From it select CAL using the SELECT Key).Here we have 3 options Amb, INP, and OUT. Scroll along using the Enter Key and select the required option using the SELECT Key. Ambient Calibration: Once you enter the ambient calibration option the ambient temperature sensed by the device is shown. Now to calibrate it press the Select Key that blinks the digits one by one on each press, use the Increment Key to change the value from 0-9. Adjust the values as required and press the Enter Key to save the value. Exit from the menu levels using the Inc/Esc Key. Now we have both Input and output calibration. Input Calibration: Here calibration is done only after entering span value(for RTD Zero & Span value sequentially). For this we require a source with good stability and resolution. Any of the inputs can be calibrated at any point within the entered range. The Inputs are divided into Six groups. Calibrating any of the inputs of a group will calibrate all the other inputs of the same group. The groups are: Group0: ETC, JTC, KTC, TTC, NTC, and 0-100mV. Group1: BTC, RTC, STC, -10-20mV. Group2: RTD. Group3: 0-5V, 1-5V. Group4: 0-2V, 0.4-2V,0-20mA, 4-20mA. Now select the INP from the menu feed the Zero input value for zero calibration (For RTD only) and enter the Zero calibration option using the Select Key. Now change the values as required using the select and Inc Key. Save the value using the Enter Key and Exit one level back using the Inc/Esc Key. Scroll to the Span calibration using the Enter key, Press Select Key to enter into the span calibration. Feed the span input for calibration and change the values as required and press Enter to perform calibration, Here it show a Wait Message until it completes the calibration Procedure. It automatically saves and applies the calibration parameters now. Exit the menu level using the Inc/Esc Key. (There is no need for repetition of calibration except RTD inputs) Output Calibration Calibration is done only after entering both zero and span values sequentially for separate channels. For this we require a DMM of 6 1/2 Digit or more resolution. Input is not required while retransmission output calibration. Calibration of current or voltage (that depends on provided factory setting) is done in described manner. In menu, first select the channel that has to be calibrated, monitor the output of that corresponding channel using DMM (Digital Multi meter). The voltage /current terminals are common and its selection is provided in factory setting. To calibrate the output, enter the zero option and correct the value you see on the display with the value you see in the DMM. Do the same for the Span too. Now select channel 2 and monitor the output of second channel and repeat the same steps as performed for the first channel output. It s recommended to calibrate 0-20mA for current type output or 0-10V for voltage type retransmission output, which again depends on provided factory setting. WIRING DETAIL Note: 18-30 VDC is Optional Supply. TERMINAL POSITION DETAIL Page 4 of 6

Note: Mount the unit vertically and keep little distance in between each unit. TABLE NO. 1:- Relay Logic Without acknowledge key pressed ALARM LATCH/ RELAY/LED NORMAL ABNORMAL UP DOWN ACK IN ABNORMAL NORMAL ACK IN NORMAL LED OFF FLASH FLASH OFF - STEADY OFF LATCH YES RELAY OFF ON ON OFF - OFF OFF HIGH LED OFF FLASH FLASH OFF - OFF OFF LATCH NO RELAY OFF ON ON OFF - OFF OFF LED OFF FLASH OFF OFF - STEADY OFF RELAY OFF ON OFF OFF - ON OFF LED OFF FLASH OFF FLASH - STEADY OFF LATCH YES RELAY OFF ON OFF ON - OFF OFF LOW LATCH NO LED OFF FLASH OFF FLASH - OFF OFF RELAY OFF ON OFF ON - OFF OFF LED OFF FLASH OFF OFF - STEADY OFF RELAY OFF ON OFF OFF - ON OFF With acknowledge key pressed ALARM LATCH/ RELAY/LED NORMAL ABNORMAL UP DOWN ACK IN ABNORMAL NORMAL ACK IN NORMAL HIGH LED OFF FLASH FLASH OFF STEADY STEADY OFF LATCH YES RELAY OFF ON ON OFF OFF OFF OFF LED OFF FLASH FLASH OFF STEADY OFF OFF Page 5 of 6

LATCH NO RELAY OFF ON ON OFF OFF OFF OFF LED OFF FLASH OFF OFF STEADY STEADY OFF RELAY OFF ON OFF OFF ON ON OFF LED OFF FLASH OFF FLASH STEADY STEADY OFF LATCH YES RELAY OFF ON OFF ON OFF OFF OFF LOW LATCH NO LED OFF FLASH OFF FLASH STEADY OFF OFF RELAY OFF ON OFF ON OFF OFF OFF LED OFF FLASH OFF OFF STEADY STEADY OFF RELAY OFF ON OFF OFF ON ON OFF Note: if open type relay is selected then relay and LED will be ON when OPEN condition, while it will remain off if not in OPEN condition. Ordering Code: Model UT - 94 Input Type APS No. Of AO & type Relay X XX X X X 1 E U1 85-265VAC 1 One 1 4-20mA N None 2 J U2 18-30VDC 2 two 2 0-20mA S Single 3 K 3 1-5VDC D Dual 4 T 4 0-5VDC 5 B 5 0-10VDC 6 R 7 S 8 N 9 Pt-100,3W C 4-20mA D 0-20mA E 1-5VDC F 0-5VDC G 0-10VDC W 0.4 to 2 X -10-20mV Y 0-100mV Z 0-2V Page 6 of 6