SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets MODEL NUMBER: SMART1200LCD Highlights Supports a half-load (350W) up to 14.3 min. during power outage Supports a full load (700W) up to 4.0 min. during power outage High 97% efficiency in line power mode Features 8 protected NEMA 5-15R outlets Offers automatic voltage regulation (AVR) LCD screen reports real-time UPS and power status Package Includes SMART1200LCD UPS Provides reliable 1200VA/700W power protection for your desktop computer, network workstation, audio/video components or media center. Protects against surges, line noise, blackouts and brownouts. Description The SMART1200LCD SmartPro LCD 120V, 1200VA/700W Line-Interactive Uninterruptible Power Supply provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss. USB cable DB9 serial cable Telephone cable Mounting hardware Owner s Manual Eight NEMA 5-15R outlets protect against surges, as well as provide up to 14.3 minutes of UPS battery support at half load (350W) and 4.0 minutes of support at full load (700W). Automatic voltage regulation (AVR) corrects severe undervoltages as low as 75V and overvoltages as high as 147V without using any battery power. EMI/RFI noise filtering improves your equipment s performance and prevents damage. A 870-joule surge suppression rating protects your equipment from harmful power surges. NEMA 5-15P plug with 6-foot cord connects to any NEMA 5-15R socket. Large rotatable LCD screen shows real-time input voltage, overload, AVR and battery statuses at a glance. Alarm sounds to indicate power loss or low battery. With Tripp Lite s free PowerAlert software (available via free web download), the SMART1200LCD enables safe unattended system shutdown and file saves in case of a prolonged power failure. Features Reliable Battery Backup Provides 1200VA/700W high-performance power protection for desktop computers, audio/video components, media centers and other electronics 1 / 6
Supports 50% load (350W) up to 12 minutes and full load (700W) up to 4 minutes Audible alarm indicates loss of utility power or low battery Battery access door enables hot-swappable, user-replaceable internal batteries Optimized Outlets 8 NEMA 5-15R outlets provide battery backup and protect against surges or spikes that can harm equipment or data Automatic Voltage Regulation (AVR) Corrects undervoltages as low as 75V and overvoltages as high as 147V without drawing battery backup power Rotatable LCD Status Screen Large LCD screen shows real-time input voltage, overload, AVR and battery statuses Rotates for easy viewing in both horizontal and vertical installations Dimmer option controls brightness level AC Line, Tel/DSL and Ethernet Surge Suppression Surge suppression rating of 870 joules protects connected equipment and data from harmful power surges Built-in RJ-45 jacks protect single-line tel/dsl or network Ethernet connection EMI/RFI Line Noise Filtering Removes electromagnetic and radio frequency interference that can disrupt or damage your equipment s performance USB and DB9 Communication Ports and Free PowerAlert Software HID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and Mac OS X USB and DB9 serial ports work with Tripp Lite PowerAlert software (available for free download at www.tripplite.com/poweralert) to enable safe, unattended system shutdown and file saves during prolonged power failure DB9 port also supports contact closure messaging for AC Present and AC Fail status Flexible Installation Options NEMA 5-15P plug with 6-foot cord connects to any NEMA 5-15R socket Adapts to vertical or horizontal installation without special hardware Includes 2U brackets for rack-mount installation Specifications 2 / 6
OVERVIEW UPC Code 037332126122 OUTPUT Output Volt Amp Capacity (VA) 1200 Output kva Capacity (kva) 1.2 Output Watt Capacity (Watts) 700 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Output Voltage Regulation (Line Mode) Output Voltage Regulation (Battery Mode) 110V; 115V; 120V 115v nominal output in battery mode 60 Hz -18%, +8% +/- 5% Output Receptacles (8) 5-15R Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) Sine wave PWM sine wave INPUT Rated input current (Maximum Load) Nominal Input Voltage(s) Supported UPS Input Connection Type Input Circuit Breakers 7A 120V AC 5-15P; Right-Angled 10A UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Recommended Electrical Service Input Phase 15A 120V Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) 4.0 min. (700w) 14.3 min. (350w) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Internal UPS Replacement Battery Cartridge Expandable Runtime Less than 4.5 hours from 10% to 90% See RBC Selector for replacement battery information No 3 / 6
VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 Overvoltage Correction Input voltages between 128 and 147 are reduced by 12% Undervoltage Correction Input voltages between 92 and 107 are boosted by 14% Severe Undervoltage Correction Input voltages between 75 and 92 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Switches Alarm Cancel Operation Audible Alarm LED Indicators Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting; STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS Operating Mode Display / CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling, Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen configuration options Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD interface (see manual) Front panel LCD display SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 870 UPS AC Suppression Response Time UPS Dataline Suppression UPS Dataline Suppression Details EMI / RFI AC Noise Suppression Instantaneous 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet 168 joules; Compatible with POE applications Yes PHYSICAL Included Mounting Accessory Description Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) Pair of mounting ears enable tower and 2-4 post rackmount installation Rackmount 3.49 x 17.33 x 10.68 8.86 x 44.02 x 27.13 Rack Height (U Spaces) 2 Minimum Required Rack Depth (inches) 13.7 Minimum Required Rack Depth (cm) 34.80 UPS Power Module Weight (lbs.) 26.56 4 / 6
UPS Power Module Weight (kg) 12.05 Shipping Dimensions (hwd / in.) 7.300 x 15.100 x 21.300 Shipping Dimensions (hwd / cm) 18.54 x 38.35 x 54.10 Shipping Weight (lbs.) 28.5000 Shipping Weight (kg) 12.93 UPS Housing Material ABS Primary UPS Height (mm) 886 Primary UPS Width (mm) 4,402 Primary UPS Depth (mm) 2,713 ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Up to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 80 AC Mode Efficiency Rating (100% Load) 97% COMMUNICATIONS Communications Interface Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility Contact closure; DB9 Serial; USB (HID enabled) Supports detailed monitoring of UPS and site power conditions; DB9 provides contact-closure notification of AC Present (pins 1,9 connected) and AC Fail (pins 1,8 connected) For local monitoring via the UPS s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert USB and DB9 Serial cabling included Supports Watchdog application, OS and hard-reboot restart options for remote applications LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) 4 milliseconds (AC to battery mode); 1 millisecond (Battery to AC mode) 75 147 SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) Green Energy-Saving Features Cold-start operation supported Greater than 95% efficiency - GREEN UPS CERTIFICATIONS 5 / 6
UPS Certifications UPS Certification Details Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA) UL1778: 2014 R8.15 5TH EDITION; CSA-C22.2 NO. 107.3-14 3RD EDITION; FCC Part 68 Certification Number 5WSWP00B001; Industry Canada Certification Number 3449-001, REN: 0.1 WARRANTY Product Warranty Period (U.S. & Canada) Product Warranty Period (Latin America) Product Warranty Period (International) Product Warranty Period (Mexico) Connected Equipment Insurance (U.S., Canada & Puerto Rico) 3-year limited warranty 3-year limited warranty 2-year limited warranty 3-year limited warranty $250,000 <a class="insurancelink" href="//www.tripplite.com/support/insurance-policy">ultimate Lifetime Insurance</a> 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies 6 / 6