Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

Similar documents
32MP Gateway. Overview and Configuration Manual

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

Air-Cooled Series R Chiller

CONTROLS. Quantum HD. Heavy Duty Performance In High Definition

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

What is the Carrier ChillerVu series counterflow application?

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

Deaerator and Surge Tank Control

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

Product Data. Features/Benefits. 50RLP Water Source Heat Pumps System Control Panel

4-step Chiller and Heat Pump Controller

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

CTC Low Temperature Process Chillers

Carrier Hong Kong Limited. Carrier Comfort Network. - optimizes the performance of HVAC Systems & is the premier solution for Building Control

Driving Proactive Facility Operations with Automated HVAC Diagnostics

YK CENTRIFUGAL LIQUID CHILLER

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Instruction Manual HID-2

GP SERIES Packaged Chillers

The Future. Today. YZ MAGNETIC BEARING CENTRIFUGAL CHILLER

Andover ContinuumTM Infinet II

User Guide. FreeCool : Free Cooling unit V1.1 ENGY-SVU001A-GB

ENCLOSURE HEAT DISSIPATION

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

MOLLIER DIAGRAM CAN BE IMPROVED!

FCU-4 FAN COIL CONTROLLER

ALTERNATING RELAYS & CONTROLLERS ARM Series

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

19XR CONTROLS UPGRADE with Optional VFD control

State-of-the-Art Technology

Fle F xs le y xs s y C s on C tr on oller

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Application Engineering

Key Features and Benefits

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

APPLIED SYSTEM AWS FAMILY FOR LARGE APPLICATIONS PRODUCT LEAFLET. Capacity from 600 to 2,010kWr. Engineered for flexibility and performance

FX2-CHILLER. Digital Control. Operations Manual

INFO GMM EC. Advanced controls system for ECOSS. The New Choice In Evaporative Cooling

PEH-WSC CONTROLS UPGRADE with Optional VFD control

MicroTech II Vertical Self-contained Systems Unit Controller

Pump Controls for Water and Wastewater. PUMP Vision. UNIVERSAL PUMP CONTROLLER, RTU, and DATA LOGGER

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC. February 17, 2010 Revised

FX 2 Instruction Manual

OM Operation and Maintenance Manual. Intelligent Equipment for Daikin Applied Trailblazer Air-cooled Scroll Chiller. Models: AGZ-D and AGZ-E

SSW06. Soft Starters.

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Sales and Engineering Data Sheet ED

High Resolution (1280x800) LCD Display Touchscreens are NEMA 4 IP66 rated (enclosure only) Pre-loaded with MCS-CONNECT

BACnet. b3867 Terminal Controllers

CenterPoint Energy Retro-Commissioning Program Application

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Building Management Solutions. for Data Centers and Mission Critical Facilities

LC-1 Level Controller & Flow Monitor

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

BACnet. b3810 Series Local Controllers

CGWN/CCUN indoor liquid chillers The compact AquaStream² solution

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Technologic 502 Variable Speed Pump Controller

Andover ContinuumTM. b3850 Series Terminal Controllers

Digistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V

clarity 3 Programmable Controller

Installation and Start-Up Instructions

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

Bell & Gossett. Technologic 500 Pump Controller. Bulletin D-125. The Most Reliable and Affordable Solution for Variable Speed Pumping Systems.

FCU-4 FAN COIL CONTROLLER

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

RTAA CONTROLS UPGRADE

Retro-Commissioning Report

Let s take a look at the central vacuum conveying control choices we have today.

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

BACnet MS/TP Interface User s Guide

Building Management Systems (BMS) Back to Basics. Presented By: Andrew Smith Leader Building Technologies A.G. Coombs Advisory

Model HM-535 Power Supply Installation and Service Instructions

BAS Chillers 8/15/2016. Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August 10, 2016

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Performance and Efficiency

that may have a direct effect on your bottom line. The question

MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

Product Manual SZ2141

MicroTech 2000 Water Source Heat Pump Unit Controller

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Intelligent Controller. Sigma Control 2

Lab and Central Plant Controller

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Transcription:

Engineering Data SED: 8012 Group: Centrifugal Chiller Date: March 2002 Supercedes: New Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers Model WSC/WDC 2002 McQuay International

Control Features WSC/WDC Chillers Feature MicroTech II Controls McQuay has incorporated the latest microprocessor technology into the MicroTech II control system to give you the ultimate in chiller control. The control includes many energy-saving features not found in any other microprocessor system on the market today. MicroTech II controller's innovative design will help keep your chiller running efficiently... day in, day out, for years to come. Figure 1, Unit Controller and Operator Interface Touch Screen The Unit Controller and Operator Interface Touch Screen mounted on a chiller unit are shown to the left. Note that the touch screen panel is on an adjustable arm so that it can be positioned comfortably for the operator. Also note that the right side of the panel contains a built-in floppy drive from which data can be conveniently download. These are but a few of the thoughtful touches built into this control system to optimize ease of operation, reliability, and efficient operation. Figure 2, Compressor Controller A major feature of the McQuay MicroTech II controller is the distributed control scheme. The picture to the left shows the compressor control panel (with cover removed) mounted at the rear of the unit adjacent to the compressor itself. Its purpose, logically enough, is to operate and control the compressor. Stacked above it in the system architecture is the unit controller and Operator Interface Touch Screen. If the Interface Touch Screen and/or unit controller is out of service, the chiller can continue to operate on the compressor controller alone. This feature provides unprecedented reliability in a chiller control system. This panel also contains the oil pump contactor and overload.

MicroTech II Features and Benefits FEATURE Easy integration into Building Management System via Protocol Selectability. Easy to read, adjustable, 10 inch, Super VGA Color Touchscreen operator interface Plottable historic trend data Precise ± 0.2 F chilled water control Proactive pre-alarm correction of unusual conditions allows chiller to stay online Automatic control of chilled water and condenser water pumps Controls up to four stages of tower fans and modulation of tower fan or bypass valve Twenty-five previous alarms along with the operating conditions at the time of the fault are stored in memory Multiple language capability metric, in-lb BENEFIT Designer is open to select any BAS supplier using an industry standard protocol and MicroTech II control will interface with it. Operators can observe chiller operation at a glance and easily select various screens and change set points Water temperatures, refrigerant pressures, and motor load plots can provide valuable information for energy conservation Provides stability in chilled water system Activates alarm and modifies chiller operation to provide maximum possible cooling Integrated lead/lag and automatic engagement of backup pump Optimum integrated control of cooling tower water based on system conditions Invaluable asset in trouble shooting Great asset for world-wide applications Designed with the System Operator in Mind Reliable, economic use of any chiller depends on easy operator interface. That s why operation simplicity was one of the main considerations in the development of MicroTech II controller. The operator interface with the chiller is through a 10 inch, Super VGA color monitor with touch-screen capability. The operator can clearly see the entire chiller graphically displayed with all of the key operating parameters viewable on the screen. Other screens, such as alarm history, are easily accessed through touch screen buttons. Competitive screw chiller controllers do not have this level of sophistication. See the following page for the initial home screen. By constantly monitoring chiller status, the MicroTech II controller will automatically take proactive measures to relieve abnormal conditions or shut the unit down should a fault occur. For example, if a problem occurs in the cooling tower and discharge pressure starts to rise, the controller will automatically hold the load point and activate an alarm signal. A further rise in pressure will initiate compressor unloading in an effort to maintain the setpoint pressure. Should the pressure continue to rise, the unit will shut off at the cutout pressure setting.

The MicroTech II controller's memory retains a snapshot of faults including all the operating conditions at the time of the shutdown, and the time/date stamp. The controller's memory (no batteries required) can retain and display the cause of the current fault and the last twenty-five fault conditions. This method for retaining the fault, and operating conditions at the time of the fault, is extremely useful for trouble shooting and maintaining an accurate record of unit performance and history. MicroTech features a two-level password security system to provide protection against unauthorized use. Figure 3, MicroTech II Controller Home Screen The Home Screen shown above is usually used as the primary viewing screen. It gives real time data on unit status, water temperatures, chilled water set point and motor amp draw. In other words it very clearly answers the vital question-is the chiller operating properly? Should an alarm occur, a red button appears on the top of the screen (a remote signal is also available). Pressing this button accesses the Active Fault Screen that gives complete fault information and from which the fault can be quickly and easily cleared.

Changing Set Points The mystery of changing set points is a thing of the past. Look at how easy the job becomes with the McQuay MicroTech II. For example to change the chilled water set point, press SET from any screen, then press the WATER button (natural choice) and this screen appears, press button #1, Leaving Water Temperature, and you are ready to go. The left side of the screen even gives a complete description of the set point including the available range of settings. Trend Logging Ever wonder how your chiller performed last week? Were you holding chilled water temperature? What kind of cooling load did the chiller have? The McQuay MicroTech II can reach back in the past, thanks to its huge memory, and plot water temperatures, refrigerant pressures, and motor load. These values can also be downloaded through a convenient floppy drive, located right in the Interface Panel, and pasted into a spreadsheet for further evaluation.

MicroTech II Controller Increases Chiller Operating Economy Many standard features have been incorporated into MicroTech II control in order to improve the operating economy of McQuay centrifugal chillers. In addition to replacing normal relay logic circuits, we ve enhanced the controller's energy saving capabilities with the following features: Direct control of water pumps. Optically isolated digital output relays provide automatic lead-lag of the evaporator and condenser pumps, permitting pump operation only when required. User-programmable compressor soft loading. Prevents excessive power draw during pull down from high chilled-water temperature conditions. Chilled-water reset. Accomplished directly on the unit by maintaining a constant return water temperature by resetting the leaving water temperature based on the return water temperature. A remote 4-20ma or 1-5 VDC BAS signal can also be used to reset the leaving water directly. Raising the chilled water set point during periods of light loads dramatically reduces electrical consumption. Demand limit control. Maximum motor current draw can be set on the panel or can be adjusted from a remote 4-20ma or 1-5 VDC BAS signal. This feature controls maximum demand charges during high usage periods. Condenser water temperature control. Capable of four stages of tower fan control plus an optional analog control of either a three-way tower-bypass valve or variable speed tower-fan motor. Stages are controlled from condenser-water temperature. The three-way valve can be controlled to a different water temperature or track the current tower stage. This allows optimum chilled water plant performance based upon specific job requirements. Staging Options (Multiple Chiller Installations). Lead-lag and load-balance: the MicroTech II controller is capable of compressor lead-lag decisions and balancing compressor loads between McQuay chillers using defaults or operator defined staging. Plotting Historic Trends. Past operation of the chiller can be plotted as trend lines and even downloaded to spread sheets for evaluation. A valuable tool for optimizing efficiency. Nonvolatile Memory Since the MicroTech II controller's memory is nonvolatile, battery backup to protect the programs and settings in case of power loss is unnecessary. Versatile Communications Capabilities Give You Even More Control For complete flexibility there are three ways to interface with the MicroTech II controller: 1. Direct entry and readout locally at the controller's operator interface panel on the unit 2. Direct entry as above plus digital and analog input/output signals for certain functions such as: Enable run input Alarm signal output 4-20ma or 0-5 VDC input for chilled water reset and load limiting Pump and tower fan control. Analog output for variable speed fan or tower bypass 3. Interface with Building Automation System with Standard Protocol Selectability with full read and write capability.

Building Automation Systems All MicroTech II controllers and system controllers are capable of communications providing seamless integration and comprehensive monitoring, control and two-way data exchange with industry standard protocols LonMARK or BACnet. Here are just a few of the many points on a WSC/WDC chiller that are available remotely through one simple, low cost interface. Operating Parameters Entering/leaving water temperatures Refrigerant temperatures and pressures Motor amps as a percent of RLA Hours of operation and number of starts Chilled water and demand limit setpoints Cause and conditions for last 25 active alarms Protection/Cycling Conditions High and low refrigerant pressures Oil pressure differential Motor condition from embedded sensors System water pump failures High discharge temperatures Starter fault Condenser water pump control relay Water flow through the condenser should be discontinued when the chiller is inoperative. Continuous flow through a cooling tower, without inclusion of building heat in the water, will overcool condenser water if tower bypass is not employed and will unnecessarily depress the chiller s refrigerant pressure. Where energy conservation is desirable, shutting off condenser water flow when the chiller is not operating provides a practical, inexpensive method of saving power. Alarm circuit Terminals are provided in each unit control panel to supply 24-volt AC power to an external alarm circuit. A 25 VA low amp draw relay coil can be connected to these terminals. The coil will be deenergized when any of the unit or system s protective controls function. The alarm is not included. Post Office Box 2510, Staunton, Virginia USA 24402-2510 800-432-1342 www.mcquay.com