Statement of Volatility Dell PowerEdge R730 and R730XD

Similar documents
Statement of Volatility Dell DR6300, DR4300, and DR4300e

Xerox Brenva HD Production Inkjet Press Xerox FreeFlow Print Server Statement of Volatility

Xerox Versant 3100 Press Xerox FreeFlow Print Server. Statement of Volatility Version 1.0

Xerox Color 800i/1000i Press FreeFlow Print Server. Statement of Volatility Version 1.0

PQA600A Picture Quality Analyzer Declassification and Security Instructions

Statement of Volatility Xerox CiPress Production Inkjet System

PQA500 Picture Quality Analyzer Declassification and Security Instructions

Dell EMC PowerEdge Installation, Management and Diagnostics

Statement of Volatility Xerox igen TM 150 Digital Press

Dell PowerEdge T110 Systems. Hardware Owner s Manual

Providing Fundamental ICT Skills for Syrian Refugees PFISR

Xerox Iridesse Press Statement of Volatility. Month 00, 0000 <Part Number>

Dell PowerEdge R620. Owner's Manual. Regulatory Model: E16S Series Regulatory Type: E16S001

Statement of Volatility Xerox EX-P 1000i Print Server, Powered by Fiery for the Xerox Color 800i/1000i Press

Memory Overview. Overview - Memory Types 2/17/16. Curtis Nelson Walla Walla University

v02.54 (C) Copyright , American Megatrends, Inc.

Fujitsu LifeBook T Series

96RC-SAS-8P-PE-LS3. Test Report. This report is also applied to the following drives since they are same generation with very similar specification.

Dell EMC Ready Solution for VMware vcloud NFV 3.0 OpenStack Edition Platform

Side-by-side comparison of the features of Dell EMC idrac9 and idrac8

Accelerating Microsoft SQL Server Performance With NVDIMM-N on Dell EMC PowerEdge R740

Fujitsu Stylistic ST6000 Series

C th Gen. Intel Core i7 6U VME SBC. Aitech. Rugged 6U VME Single-Slot SBC 5 th Generation Intel Core i7 CPU

Dell PowerEdge R300 Systems Hardware Owner s Manual

Dell PowerEdge R300 Systems Hardware Owner s Manual

v02.54 (C) Copyright , American Megatrends, Inc.

COMPUTING. MVME8100 NXP QorIQ P5020 VME64x/VXS SBC. Data Sheet

Lifecycle Controller Platform Update in Dell PowerEdge 1 2 th Generation Servers

Towards an Heterogeneous Memory Channel with Hybrid Modules. Bill Gervasi October 2015

FUNCTIONS OF COMPONENTS OF A PERSONAL COMPUTER

Dell PowerEdge M830 Owner's Manual

Dell PowerEdge R710 Systems Hardware Owner s Manual

Intel Server Board SHG2 Troubleshooting Guide

Computer Organization. 8th Edition. Chapter 5 Internal Memory

Optimize your system designs using Flash memory

Lesson 6 Intel Galileo and Edison Prototype Development Platforms. Chapter-8 L06: "Internet of Things ", Raj Kamal, Publs.: McGraw-Hill Education

Statement of Volatility XEROX 700 Digital Color Press

BIOS Update Release Notes

Xerox EX 180 Print Server, Powered by Fiery Statement of Volatility. Month 0 <Part Nu

Statement of Volatility Xerox Wide Format IJP 2000

IDENTIFICATION OF VOLATILE AND NON-VOLATILE STORAGE AND SANITIZATION OF SYSTEM COMPONENTS JUNIPER NETWORKS SRX-SERIES SRX AP(DP)

Memory classification:- Topics covered:- types,organization and working

COM-RZN1D - Hardware Manual

Dell PowerEdge VRTX Storage Subsystem Compatibility Matrix

Capabilities and System Benefits Enabled by NVDIMM-N

Dell EMC PowerEdge Systems SUSE Linux Enterprise Server 15. Installation Instructions and Important Information

Dell PowerEdge R630. Owner's Manual. Regulatory Model: E26S Series Regulatory Type: E26S001

Xerox Color Press

Dell PowerEdge M630 Owner's Manual

RunBMC - A Modular BMC Mezzanine Card BUV - Bring Up Vehicle For BMC Mezzanine. Eric Shobe & Jared Mednick Hardware Engineer - Salesforce

ARDUINO YÚN MINI Code: A000108

Lifecycle Controller 2 Release 1.0 Version Readme

Chapter 3: Computer Assembly

Xerox WorkCentre Statement of Volatility Version 1.0

Dell PowerEdge R430. Owner's Manual. Regulatory Model: E28S Series Regulatory Type: E28S001

It also offers a RAM backed file system that will disappear on loss of power. NOT APPLICABLE. Memory Information and Procedures

BIOS Setup. User s Guide. (For Skylake-W Platform) Rev.1.1

Dell PowerEdge R330 Owner's Manual

Fujitsu LifeBook T Series

Chapter 4 Using BIOS 1

Fujitsu LifeBook T Series

BIOS Setup. User s Guide. (for Cavium Platform) Rev.0.2

Chapter 4 Main Memory

Security Features and Volatility Documentation

Dell PowerEdge R920 System Owner's Manual

Internal Memory. Computer Architecture. Outline. Memory Hierarchy. Semiconductor Memory Types. Copyright 2000 N. AYDIN. All rights reserved.

A. Windows 7 and USB driver installation

Dell PowerEdge T130 Owner's Manual

AT-501 Cortex-A5 System On Module Product Brief

Persistent Memory. High Speed and Low Latency. White Paper M-WP006

Fujitsu LifeBook A & V Series

Fujitsu LifeBook U Series

Statement of Volatility Xerox WorkCentre 4250/4260

Review Questions on Computer Basics

SOM Qseven Spec. System On Module. USER Manual V1.0

Microcontroller Systems. ELET 3232 Topic 11: General Memory Interfacing

Reliability, Availability, Serviceability (RAS) and Management for Non-Volatile Memory Storage

Dell PowerEdge FC430. Owner's Manual. Regulatory Model: E01B Series Regulatory Type: E01B002

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY

BIOS Update Release Notes PRODUCTS: DQ67SW, DQ67OW, DQ67EP (Standard BIOS)

Fujitsu LifeBook T Series

Fujitsu LifeBook A Series

Fujitsu LifeBook P Series

DIGITAL SYSTEM FUNDAMENTALS (ECE421) DIGITAL ELECTRONICS FUNDAMENTAL (ECE422)

Embedded BIOS. Features and Board Support Packages congatec AG 1

Dell PowerEdge M820 Systems Owner's Manual

BIOS SETUP UTILITY. v02.54 (C) Copyright , American Megatrends, Inc.

Lifecycle Controller Version User's Guide

Dell XC720xd Owner's Manual

DELL EMC NX WINDOWS NAS SERIES CONFIGURATION GUIDE

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Implementing Bootloaders on Renesas MCUs

Specification Manual

Fujitsu LifeBook N Series

NOVASCALE. NovaScale R430 F2. Hardware Owner's Manual REFERENCE 86 A1 62FD 00

BIOS Update Release Notes PRODUCTS: DQ67SW, DQ67OW, DQ67EP (Standard BIOS)

Dell Chassis Management Controller Version 3.0 for PowerEdge VRTX. Release Notes

v02.54 (C) Copyright , American Megatrends, Inc. BIOS SETUP UTILITY v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc.

v02.54 (C) Copyright , American Megatrends, Inc.

Transcription:

Statement of Volatility Dell PowerEdge R730 and R730XD Dell PowerEdge R730 and R730XD contains both volatile and non-volatile (NV) components. Volatile components lose their data immediately upon removal of power from the component. Non-volatile components continue to retain their data even after the power has been removed from the component. Components chosen as user-definable configuration options (those not soldered to the motherboard) are not included in the Statement of Volatility. Configuration option information (pertinent to options such as microprocessors, remote access controllers, and storage controllers) is available by component separately. The following NV components are present in the PowerEdge R730 and R730XD servers. Item Non-Volatile or Volatile Quantity Reference Designator Size Planar PCH Internal CMOS RAM Non-Volatile 1 U_PCH 256 Bytes BIOS Password Non-Volatile 1 U_PCH 16 bytes BIOS SPI Flash Non-Volatile 1 U_SPI_BIOS 16 MB idrac SPI Flash Non-Volatile 1 U_IDRAC_SPI 4 MB BMC EMMC Non-Volatile 1 U_EMMC 4 GB CPU Vcore Regulators Non-Volatile 2 U8003, U8043 512 Bytes Vmem Regulators Non-Volatile 2 U8011, U8051 512 Bytes System CPLD RAM Volatile 1 U_CPLD 1 KB System Memory Volatile Up to 12 per CPU CPU<2:1>_CH<3:0>_ D<2:0> Up to 64GB per DIMM Internal USB Key Non-Volatile Up to 1 N/A Varies (not factory installed) CPU Volatile 1 or 2 CPU1 / CPU2 Various idrac DDR Volatile 1 U_IDRAC_MEM 256MByte idrac Volatile 1 U_IDRAC 64 kbyte + registers 2x2.5" Backplane SEP internal flash Non-Volatile 1 U_SEP Flash:32KB+4KB EEPROM: 2KB Backplane External FRU Non-Volatile 1 U_BP_EEPROM 256 Bytes 4x3.5" Backplane 03-2016

SEP internal flash Non-Volatile 1 U_SEP Flash:32KB+4KB EEPROM: 2KB Backplane External FRU Non-Volatile 1 U_BP_EEPROM 256 Bytes 24x2.5" EXP/Backplane NVSRAM memory Non-Volatile 1 U_NVSRAM 1 Mb Flash memory Non-Volatile 1 U_FLASH 128 Mb Expander FRU image Non-Volatile 1 U_EXP_EEPROM 512 Bytes BP FRU image Non-Volatile 1 U_BP_EEPROM 256 Bytes 16x2.5" EXP/Backplane NVSRAM memory Non-Volatile 1 U_NVSRAM 1 Mb Flash memory Non-Volatile 1 U_FLASH 128 Mb Expander FRU image Non-Volatile 1 U_EXP_EEPROM 512 Bytes BP FRU image Non-Volatile 1 U_BP_EEPROM 256 Bytes 8x2.5" Backplane SEP internal flash Non-Volatile 1 U_SEP Flash:32KB+4KB EEPROM: 2KB 8x3.5" Backplane SEP internal flash Non-Volatile 1 U_SEP Flash:32KB+4KB EEPROM: 2KB Backplane External FRU Non-Volatile 1 U_BP_EEPROM 256 Bytes 12x3.5" EXP/Backplane NVSRAM memory Non-Volatile 1 U_NVSRAM 1 Mb Flash memory Non-Volatile 1 U_FLASH 128 Mb BP FRU image Non-Volatile 1 U_BP_FRU 256 Bytes Expander FRU image Non-Volatile 1 U_EXP_FRU 512 Bytes 18x1.8" Exp/Backplane NVSRAM memory Non-Volatile 1 U_NVSRAM 1 Mb Flash memory Non-Volatile 1 U_FLASH 128 Mb BP FRU image Non-Volatile 1 U_BP_EEPROM 256 Bytes Expander FRU image Non-Volatile 1 U_EXP_EEPROM1 512 Bytes H730, H830 PERCs

NVSRAM Non-volatile 1 U1033 128KB FRU Non-volatile 1 U1019 256B 1-Wire EEPROM Non-volatile 1 U1004 128B SPD Non-volatile 1 U22 256B SBR Non-volatile 1 U1020 8KB Flash Non-volatile 1 U1031 16MB ONFI Backup Flash Non-volatile 1 U1059 4GB SDRAM Volatile 5 U1043-U1047 512MB/1GB H330, H330M PERC NVSRAM Non-volatile 1 U1033 128KB FRU Non-volatile 1 U1019 256B 1-Wire EEPROM Non-volatile 1 U1004 128B SBR Non-volatile 1 U1020 8KB Flash Non-volatile 1 U3 16MB PCIe SSD Extension Card Switch Configuration EEPROM Non-Volatile 1 U2 256B IDSDM SPI Flash Non-Volatile 1 U2 8Mb MCU Non-Volatile 1 U6 512KB Left Ear - R730xd SPI Flash Non-Volatile 1 U_SPI_EEPROM 32Mb Main Control Panel -R730 SPI Flash Non-Volatile 1 U_SPI_FLASH 32Mb TPM Trusted Platform Module (TPM) Non-Volatile 1 U_TPM 128 Bytes idrac Quick Sync MCU MSP430 Non-Volatile 1 U_MSP430 128KB

Item Type (e.g. Flash PROM, EEPROM) Can user programs or operating system write data to it during normal operation? Purpose? (e.g. boot code) Planar PCH Internal CMOS RAM Battery-backed CMOS RAM No Real-time clock and BIOS configuration settings BIOS Password Battery-backed CMOS RAM Yes Password to change BIOS settings BIOS SPI Flash SPI Flash No Boot code, system configuration information, UEFI environment, Flash descriptor, ME idrac SPI Flash SPI Flash No idrac Uboot (bootloader), server management persistent store (i.e. IDRAC MAC Address, idrac boot variables), lifecycle log cache, virtual planar FRU and EPPID, rac log, system event log, JobStore, idrac Secure boot code, BMC EMMC emmc NAND Flash No Operational idrac FW, Lifecycle Controller (LC) USC partition, LC service diags, LC OS drivers, USC firmware CPU Vcore Regulators ROM No Operational parameters Vmem Regulators ROM No Operational parameters System CPLD RAM RAM No Not utilized System Memory DRAM Yes System OS RAM Internal USB Key Flash Yes General purpose USB key drive CPU Cache + registers Yes Processor cache + registers idrac DDR DRAM No idrac local memory idrac Cache + registers No Processor cache + registers 2x2.5" Backplane

SEP internal flash Integrated Flash+EEPROM No Firmware + FRU Backplane External FRU I2C EEPROM No FRU 4x3.5" Backplane SEP internal flash Integrated Flash+EEPROM No Firmware + FRU Backplane External FRU I2C EEPROM No FRU 24x2.5" EXP/Backplane NVSRAM memory Flash No FW config data Flash memory Flash No Firmware Expander FRU image I2C EEPROM No FRU BP FRU image I2C EEPROM No FRU 16x2.5" EXP/Backplane NVSRAM memory Flash No FW config data Flash memory Flash No Firmware Expander FRU image I2C EEPROM No FRU BP FRU image I2C EEPROM No FRU 8x2.5" Backplane SEP internal flash Integrated Flash+EEPROM No Firmware + FRU 8x3.5" Backplane SEP internal flash Integrated Flash+EEPROM No Firmware + FRU Backplane External FRU I2C EEPROM No FRU 12x3.5" EXP/Backplane NVSRAM memory Flash No FW config data Flash memory Flash No Firmware BP FRU image I2C EEPROM No FRU Expander FRU image I2C EEPROM No FRU

18x1.8" Exp/Backplane NVSRAM memory Flash No FW config data Flash memory Flash No Firmware BP FRU image I2C EEPROM No FRU Expander FRU image I2C EEPROM No FRU H730, H830 PERCs NVSRAM NVSRAM No Configuration data FRU FRU No Card manufacturing information 1-Wire EEPROM 1-Wire EEPROM No Holds default controller properties/settings SPD SPD No Memory configuration data SBR SBR No Bootloader Flash Flash No Card firmware ONFI Backup Flash ONFI Backup Flash No Holds cache data during power loss SDRAM SDRAM No Cache for HDD I/O H330, H330M PERC NVSRAM NVSRAM No Configuration data FRU FRU No Card manufacturing information 1-Wire EEPROM 1-Wire EEPROM No Holds default controller properties/settings SBR SBR No Bootloader Flash Flash No Card firmware PCIe SSD Extension Card Switch Configuration EEPROM SPI Flash EEPROM No (requires specialized SW) Configuration for PLX PCIe switch, setting registers IDSDM SPI Flash SPI Flash No Exclusively used by the controller

MCU Embedded Flash Yes Firmware Left Ear - R730xd SPI Flash SPI Flash No For field maintenance. Have License, Service Tag and system information. Main Control Panel - R730 SPI Flash SPI Flash No For field maintenance. Have License, Service Tag and system information. TPM Trusted Platform Module (TPM) EEPROM Yes Storage of encryption keys idrac Quick Sync MCU MSP430 Flash No idrac Quick Sync Communicate Protocol

Item How is data input to this memory? How is this memory write protected? How is the memory cleared? Planar PCH Internal CMOS RAM BIOS N/A BIOS only control 1) Set NVRAM_CLR jumper to clear BIOS configuration settings at boot and reboot system; 2) AC power off system, remove coin cell battery for 30 seconds, replace battery and power back on; 3) restore default configuration in F2 system setup menu. BIOS Password Keyboard N/A Place shunt on J_PSWD_NVRAM jumper pins 2 and 4. BIOS SPI Flash SPI interface via idrac Software write protected idrac SPI Flash SPI interface via idrac Embedded idrac subsystem firmware actively controls sub area based write protection as needed. Not possible with any utilities or applications and system is not functional if corrupted/removed. Not completely user clearable; however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface BMC EMMC NAND Flash interface via idrac Embedded FW write protected Not completely user clearable; however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface CPU Vcore Regulators NA Vmem Regulators NA System CPLD RAM Not utilized Not accessible Not accessible System Memory System OS OS Control Reboot or power down system Internal USB Key USB interface via PCH. Accessed via system OS No write protect Can be cleared in system OS CPU Various Various Power off idrac DDR idrac Firmware NA Power off idrac idrac Firmware NA Power off

2x2.5" Backplane SEP internal flash I2C interface via idrac Program write protect bit Backplane External FRU Programmed at ICT during production. Not WP 4x3.5" Backplane SEP internal flash I2C interface via idrac Program write protect bit Backplane External FRU Programmed at ICT during production. Not WP 24x2.5" EXP/Backplane NVSRAM memory Flash memory Expander FRU image I2C interface via expander BP FRU image I2C interface via idrac 16x2.5" EXP/Backplane NVSRAM memory Flash memory Expander FRU image I2C interface via Expander BP FRU image I2C interface via idrac 8x2.5" Backplane SEP internal flash I2C interface via idrac Program write protect bit 8x3.5" Backplane SEP internal flash I2C interface via idrac Program write protect bit Backplane External FRU Programmed at ICT during production. Not WP

12x3.5" EXP/Backplane NVSRAM memory Flash memory BP FRU image I2C interface via expander Expander FRU image I2C interface via idrac 18x1.8" Exp/Backplane NVSRAM memory Flash memory BP FRU image I2C interface via expander Expander FRU image I2C interface via idrac H730, H830 PERCs NVSRAM ROC writes configuration data to NVSRAM FRU Programmed at ICT during production. Not WP 1-Wire EEPROM ROC writes data to this memory SPD Pre-programmed before assembly SBR Pre-programmed before assembly Flash Pre-programmed before assembly. Can be updated using Dell/LSI tools ONFI Backup Flash FPGA backs up DDR data to this device in case of a power failure Flash can be cleared by powering up the card and allowing the controller to flush the contents to VDs. If the VDs are no longer available, cache can be cleared by going into controller bios and selecting Discard Preserved Cache.

SDRAM ROC writes to this memory - using it as cache for data IO to HDDs Cache can be cleared by powering off the card H330, H330M PERC NVSRAM ROC writes configuration data to NVSRAM FRU Programmed at ICT during production Not WP 1-Wire EEPROM ROC writes data to this memory SBR Pre-programmed before assembly Flash Pre-programmed before assembly. Can be updated using Dell/LSI tools PCIe SSD Extension Card Switch Configuration EEPROM The EEPROM image is preloaded at factory before assembly. Once assembled on the card, data can be entered via PLX Device Editor or PLX EEP DOS based tool. Device can be write protected via hardware pin. Alternatively, device contents can be write protected via WPEN bit in status register. System is not functional as intended if corrupted/removed. IDSDM SPI Flash SPI interface via idrac MCU USB3.0 interface via PCH, FW can be updated via idrac which runs on Linux N/A Left Ear - R730xd SPI Flash SPI interface via idrac Main Control Panel - R730 SPI Flash SPI interface via idrac TPM Trusted Platform Module (TPM) Using TPM Enabled operating systems SW write protected F2 Setup option

idrac Quick Sync MCU MSP430 I2C interface via idrac - It also auto-clears when power is applied. Power Supplies Item Non-Volatile or Volatile Quantity Reference Designator Size Type (e.g. Flash PROM, EEPROM) Can user programs or operating system write data to it during normal operation? Purpose? (e.g. boot code) How is data input to this memory? How is this memory write protected? How is the memory cleared? PSU FW Non-Volatile 1 per PSU Varies by PSU Part Number Up to 2MB which varies by part number Embedded microcontroller flash No Power Supply operation, power management data and fault behaviors Different vendors have different utilities and tools to load the data to memory. It can also be loaded by Dell Update Package from LC or OS (Windows and Linux) Protected by the embedded microcontroller. Special keys are used by special vendor provided utilities to unlock the ROM with various CRC checks during load. NOTE: For any information that you may need, direct your questions to your Dell Marketing contact. 2016 Dell Inc. Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.