Lucid arena pro LED luminaire

Similar documents
Operation, installation and service instructions. Lucid nova pro LED luminaire

Installation manual plugs and connectors with screw connection (16/32 A)

SolConeX extra-low voltage flange socket

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

icore Kiosk system Installation Guide

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

SolConeX Wall-Mounted Socket, 16 A

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating instructions. Switching amplifier DN0210 DN / / 2015

Fog machine PT Users Manual

HST -S1 Switching element (Translation of Original Manual)

PV Module Installation Instructions

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Operating Instructions

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

POCKET MULTIMETER Model No: MM18

Operating instructions. Speed monitor D / / 2014

1 Channel Strobe Controller ORDERCODE 40226

Large Police Light 100W ORDERCODE 80361

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

HV-CS kv Edge Mount Triaxial Jack

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating instructions Evaluation system for flow sensors VS / / 2013

MBE Mounts and Adapters

TA18 active subwoofer. user manual

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

LED Pixel Rail 40 RGB LED strip. user manual

DuoFern Multiple Wall Controller

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

MDM 011-Z1 Regen Resistor

Model 2657A-LIM-3 LO Interconnect Module

XCU Fusion. 316L stainless-steel dual imager camera. Installation Manual

Model 7705 Control Module

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

IPCB42501 / IPCB42551

TPC25 active crossover. user manual

Promopar ORDERCODE 30120

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

LED SPIDER MOVING HEAD LIGHT

Model 2380 Rack-Mount Kit

...easy to operate with ProHomeIPC. IP-Kamera OC 800 Quick Start Guide

High Power Electronic Gear Installation and operation Guide

Gobo Projector XP 80W

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

HST -TS1 Guard-locking mechanism (Translation of Original Manual)

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

DC-D2212R / DC-D2212WR

B63/ NS MS. EtherNet/IP LINK

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

LED W RGBA User Manual

TA12 full-rangespeaker. user manual

Weathersafe Vision. Installation & Operating Instructions

DC-D4213RX DC-D4213WRX

LED Shoe Box light FEATURES AND BENEFITS: ORDERING MATRIX: LED SHOE BOX LIGHT:

Orbital smart Tunable Downlight

Operating instructions. Standstill monitor A / / 2011

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

NXT4 Three phase meter for commercial, industrial and advanced residential applications

D-Pack 6 Classic ORDERCODE 50315

SOLARIMMERSION IV Advanced Installation Manual v1.9

HD40H(X) Performance Series Camera. User Guide

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Installation and safety instructions for devices for conveying air/gas mixtures

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model No. ET-JPF200BE

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Installation Instructions

PHOS mini OPERATING INSTRUCTIONS

VDLPROM5 SET WITH DMX CONTROL BOX + 4 COLOUR CHANGERS

RТTH DUAL ROOM SWITCH

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

2260B-RMK-Series Rack Mount Kit

LIGHT BRICK - 12 X 3W TRI-COLOUR

GRP Flameproof Visual Signal Xenon or Steady LED

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Portable Sampler MAXX TP5 W / P / C

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating Manual. icam100

Model 2380 Rack-Mount Kit

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Flexoled FTP3HP RGB LED DMX Driver

Table of contents 2 / 8

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Transcription:

Operation, installation and service instructions Lucid arena pro LED luminaire Please read these instructions before installing the luminaires, using them for the first time, storage or handling. These installation and service instructions, edition 13.03.2017 apply to the Lucid arena pro LED luminaire 1

Introduction Dear customer, Many thanks for buying this product from us and for the trust you have placed in us. Please read these operating, installation and service instructions carefully before using the product. These instructions are aimed at suitable qualified persons (e.g. electricians, installers or engineers) tasked with installation and maintenance of this product. It applies for all versions of the Lucid arena pro LED luminaire. LED luminaire in the Lucid arena pro range are intended for professional use indoors. Technical personnel must be familiar with all technical electrical directives and safety precautions, and apply these appropriately in each case. These instructions are not suitable or intended for users and consumers without specialist technical knowledge. For questions concerning handling the luminaire, which are not answered in these instructions, please contact: LIGHTS 4 Europe GmbH & Co. KG Gaildorfer Str. 6 71522 Backnang Germany Telephone +49 7191 323020 Telefax +49 7191 323029 Email: info@lights.de We wish your every success with our product and hope you enjoy saving energy 2

Product description & applications The LED luminaire in the Lucid arena pro range come complete with an integrated power supply / driver for operating the luminaire. The Lucid arena pro is suitable for professional use in industrial, production and warehouse buildings and for working areas. The Lucid arena pro is subject to quality checks in accordance with European standards. The luminaire stand out not only because of their modern design, but above all because of a number of special technical features, which guarantee the best possible technical performance. These include highly-efficient lens optics, high-quality housing materials, constant current control, temperature monitoring, as well as lifelong regulation of luminous flux. The working temperature of -30 to 40 C facilitates a wide range of applications. 3

Labels To help precise identification of the product, you will find information about the model and item number on the type plate. We recommend you make a note of this information so it is available if you have any questions later. This will help us handle your query more quickly. Symbols By using the CE mark, the manufacturer confirms that the product conforms to the applicable, product specific European directives. The ENEC sign is the conformity sign for electrical products agreed upon by the verifying authorities in the European Union. It stands for conformity with the European safety standards, especially the EN 60598 and thus also with German VDE 0711. The ENEC sign is displayed in connection with the identity characters for the national verifying authority (the 10, for example, stands for the VDE) and often with the own logo of the respective institute. The VDE sign documents the safety and compliance to standards of an electrical product with respect to electrical, mechanical, thermal, toxic and other hazards. A manufacturer may only use the VDE sign on his products after the test has been performed and a corresponding certificate has been issued. None of the components in this product exceeds the permissible thresholds for use of hazardous materials in accordance with the RoHS directive 2011/65/EU All electrically conductive housing components in the equipment are connected to the protective conductor system of the fixed electrical installation, which is at earth potential. The symbol may be carried if the safety of all external parts of the luminaire, especially the glass plate, against thrown balls has been ensured and demonstrated. An electrical product marked with this symbol may not be disposed of in domestic waste. The IP protection classification system categories the level of protection which a housing for electrical devices offers against solids (e.g. dust) and liquids (water, oil etc.). IP66 means 6 = dust-proof and 6 = Protected against heavy spray water 4

Installation - general safety instructions CAUTION - DANGER OF ELECTROCUTION Only appropriate technical personnel may work on electrical systems. There is a risk of fatal electrocution. Before working on electrical systems and switching units, they should be removed from the power supply and secured against accidental re-connection. Before touching conductive components and cables, use appropriate equipment to confirm they are actually isolated from the power supply. First read the operating instructions through completely, as they contain important information for correct fitting and operation. Any damage caused by non-compliance with these operating instructions invalidates the warranty/guarantee! We do not accept any liability for direct or consequential damages! We do not accept any liability for personal or property damage caused by improper use or noncompliance with the safety instructions! In these cases, the warranty/guarantee is invalidated! The product may not be opened (please also read the instructions in the chapter MAINTENANCE). The light source in these luminaires is not replaceable. When the light source has reached the end of its life, the whole light must be replaced Do not install the product on a damp or conductive surface. To avoid any hazard, a damaged outer flexible lead on this light may only be replaced by the manufacturer, their representative or a comparable qualified person. Only install the product in switched-off mode. Only install the product in intended electrical systems and voltage ranges. Check and compare the information on this on the product s type plate. If a fault occurs, disconnect the product from the mains power supply and any other connected devices. Then ensure neither can be switched on again accidentally. If you cannot guarantee that the product can be operated without any danger, disconnect the product immediately from the mains power supply and any other connected devices. Once more, ensure neither can be switched on again accidentally. It is not possible to guarantee that the product can be operated without any danger when, for example, the housing or power cable is damaged, or if any foreign objects have penetrated it. Use suitable, approved power cables and cable connectors / clips of an adequate size. Make sure the cables sit firmly in the connectors. Any loose or exposed cables represent an extremely high risk of electric shock and fire. When working under roofs, on masts or any other high fitting sites, ensure you are on a solid base by using approved, certified ladders, or risers, as well as fall protection for personnel, tools and the product to be installed. Cordon off the area under the installation area adequately. 5

Preparation for fitting Only fit the luminaire to a solid surface, e.g. masonry. Depending on the surface, use suitable screws and dowels. The luminaire may only be installed when disconnected from the mains power supply. It is not enough to switch off the luminaire switch! Switch off all poles of the mains electrical power supply by removing the associated circuit fuse or switching off the circuit breaker. Ensure these cannot be switched on again without authorisation, e.g. with a warning sign. Also switch off the associated earth leakage circuit breaker. Check the mains cable to ensure it is not live, e.g. with a suitable measuring device. After unpacking the luminaire, loosen the clamping screws on the side of the bracket by about 5 mm using an Allen key and put the bracket in an upright position. Please make sure that the connecting cable is not clamped between the bracket and the heat sink. Afterwards tighten the bracket again. Bracket in transport position Put bracket in a vertical position 6

Fitting Assemble the LED luminaire with at least two stainless steel fastening screws with a diameter of 6 mm. The drilling distance between the holes is 200 mm. Then connect the existing, flexible connection cable for mains supply on the product to the existing power supply on site, protected in an external power distribution box (not included), with at least the same protection type (IP66) as the product, in accordance with the following illustration. Cable end sleeves should be used with multicore flexible cables. For the connection terminal, we recommend using a 3 pole, insulated connector from the WAGO 294 series for a nominal cross section of 2.5 mm² and a nominal voltage of at least 500 V, meeting the VDE directives 0700 (EN 60 335-1), VDE 0613 (EN 60 998) and VDE 0711 (EN 60 598-1) for use in devices and lights up to 24 A. After the LED luminaire has been aligned all the screws must be tightened. Please take care not to damage the power cable when aligning the LED luminaire. Check that the screws are tightly in place once a year. Wiring diagram Neutral [N] (blue) Live [L] (brown or black) Grounding [PE] (yellow/green) 7

Assembly instructions for twin holder As a variant for the assembly of luminaires from the Lucid arena pro series its possible to combine two luminaires. For this we offer the twin holder with the item No. 19500. By buying the Twin holder you will receive following parts: 1 x holder Twin stainless steel rust-free - material - 1.4301 2 x screws M6 x 20/DIN 912 4 x washers Ø 6,4 / DIN 125, Form A 2 x self-locking nuts, DIN 985, A2 Assembly the Twin holder 1. Take two single LED luminaires out of the box and dismantle the assembly bracket. Do not discard the bracket and screws. 2. Fix the respective LED luminaire to the Twin holder using the screws provided. Please observe the correct sequence: - Spacer - "Twin" holding bracket - small washer - Circlip - Fastening screw 3. Screw the assembly bracket onto the Twin holder using the assembly material provided (screw packaging). 1. 3. 2. Assembly work may only be carried out by expert personnel. 8

Temperature measuring point (tc) The maximum temperature of 80 C at the marking shown in the illustration may not be exceeded. By maintaining the maximum temperature at the tc position it is ensured that components will become hotter than permitted. When the temperature gets too high, sufficient cooling must be provided or the luminaire must be switched off. Temperaturmesspunkt (tc) 9

Maintenance, care and cleaning This product requires no maintenance and so does not contain any components which can be checked or replaced by the user. The light source in the luminaires cannot be replaced. In the event of damage, the complete light unit must be replaced. The product is fitted with appropriate safety precautions, which show unauthorised opening (safety screws). In the event of unauthorised opening of the device or removal of the type plate, any guarantee rights will be invalidated. We recommend carrying out regular checks of the screws and the cabling, as well as a visual inspection of the housing and the diffuser for penetration by foreign bodies or superficial damage. During maintenance, the product should be disconnected from the power supply and steps take to ensure it cannot be switched on again accidentally. We recommend cleaning with a damp, soft, lint-free cloth. Do not use abrasive sponges or aggressive cleaners. During cleaning, the product should be disconnected from the power supply and steps take to ensure it cannot be switched on again accidentally. Please note the general safety instructions in the chapter INSTALLATION. Disposal The Lucid arena pro has been developed and manufactured using high-quality materials and components. The symbol means that this product falls under the European directive 2002/96/EG gilt. Please familiarise yourself with the relevant directives relating to the separate collection of old electric and electronic equipment in your country. Please observe the applicable regulations in your country, and do not dispose of disused equipment in domestic waste. Proper disposal of your old devices protects the environment and people from potential negative consequences and contributes towards conserving valuable resources. 10

Technical data Lucid arena pro 120 / 118 W 11

12

Technical data Lucid arena pro / 115 W 13

14

Guarantee period 1. The guarantee period is 2 years, where an extension to the guarantee was not agreed for an extra fee at the time of purchase. This starts when the product is delivered to the end user. Any claims under guarantee must be made in writing. 2. To validate a guarantee claim, the receipt must be presented, on which the delivery or purchase data is clearly visible. In the event of a claim under guarantee, the device should be sent to your specialist retailer or to the following address: LIGHTS 4 Europe GmbH & Co. KG (in the following LIGHTS ) Gaildorfer Str. 6 D-71522 Backnang Email: info@lights.de All design, material and manufacturing faults are covered by the guarantee. 3. The guarantee excludes any faults or deficiencies relating to the following points: a) Failure to follow the operating and safety instructions. b) Natural wear and tear. c) External factors such as transport damage, damage caused by impact, shock or over heating, as well as chemical or electro-chemical factors such as those caused by water, acids or improper use. d) Repairs or alterations carried our by non-authorised third parties. e) Use of unsuitable accessories. f) Unauthorised opening of the housing g) Removal of the type plate 4. The following are also excluded: Damage caused by improper handling, fitting or maintenance of the luminaires (see fitting instructions), damage caused by excessive force, fire, vandalism or accidental damage. 5. LIGHTS will resolve any faults within the guarantee period in consultation with the specialist retailer. This will take the form either of a repair of replacement of the component in question. Parts removed become the property of LIGHTS. Any further claims, of any kind, in particular claims for damages are excluded. 6. The following are excluded from the guarantee: a) Costs for removal / fitting of the faulty or repaired luminaires b) Costs for sending back the faulty luminaires 7. LED luminaire from LIGHTS are subject to ongoing development with regard to technical progress. For this reason, in the event of a repair or a replacement, the design of the repaired or replaced light may not correspond to the original design of the light subject to the claim, but it may be of equal or higher quality in terms of its properties and features. LIGHTS reserves the right to change guarantee periods, fixed price arrangements and conditions without prior notice. However, guarantees with a valid registration before the time of the change remain unaffected by this. LIGHTS reserves the right to make the final decision with regard to the validity of a guarantee claim. 15

Legal notices These operating instructions contain the information required for appropriate use. Knowledge and observance contained in these operating instructions are a condition of safe use and for safety in operation. These operating instructions cannot consider every possible application. The LED luminaires are intended for use indoors. In addition, we would like to point out that the contents of these operating instructions are not part of, or represent a change to, a prior or existing agreement, consent or legal relationship. The operating instructions contain information, which is copyright protected. Production of photocopies, or translations into another language, are not allowed without prior written permission from LIGHTS 4 Europe GmbH & Co. KG - Germany. LED-Luminaire and light sources from LIGHTS 4 Europe GmbH & Co. KG are subject to ongoing development with regard to technical progress. 16