Driver C 35W 7/8/5mA flexc SR ADV ADVACED series Product description Independent constant current ED Driver Adjustable output current between 7, 8 and,5 ma Max. output power 35 W Up to 87.5 % efficiency ominal life-time up to 5, h For luminaires of protection class I and protection class II For luminaires with M and MM as per E 6598, VDE 7 and VDE 7 Temperature protection as per E 6347--3 C5e 5-year guarantee Housing properties Casing: polycarbonate, white Type of protection IP Interfaces Input terminals: screw terminals Output terminals: 45 push terminals Functions Overload protection Short-circuit protection o-load protection Overtemperature protection Burst protection voltage kv Surge protection voltage kv ( to ) Surge protection voltage kv (/ to earth) Typical applications For spot light and downlight in retail and hospitality application For panel light and area light in office and education application È Standards, page 4 Wiring diagrams and installation examples, page 4 www.tridonic.com
Driver C 35W 7/8/5mA flexc SR ADV ADVACED series Technical data Rated supply voltage 4 V AC voltage range 98 64 V Max. input current (at 3 V, 5 Hz, full load).9 A eakage current (at 3 V, 5 Hz, full load) < 4 µa Mains frequency 5 / 6 Hz Overvoltage protection 3 V AC, h Max. input power 4 W Typ. power consumption (at 3 V, 5 Hz, full load) 4 W Min. output power 7.5 W Max. output power 35 W Typ. efficiency (at 3 V / 5 Hz / full load) 87.5 % λ (at 3 V, 5 Hz, full load).95 Output current tolerance 5 ± % Max. output current peak 3 output current + % Max. output voltage 6 V THD (at 3 V, 5 Hz, full load) < % Output F current ripple (< Hz) ± 5 % Time to light (at 3 V, 5 Hz, full load).5 s Turn off time (at 3 V, 5 Hz, full load).5 s Hold on time at power failure (output) s Ambient temperature ta (at life-time 5, h) 4 C Storage temperature ts -4... +8 C Dimensions x W x H 59.4 x 8 x 34 mm 6 Ordering data Type 5,5 tc 45 4,5 33 34 33 8 Article number Ø 86 Packaging, carton Packaging, low volume Packaging, high volume Weight per pc. C 35W 7/8/5mA flexc SR ADV 87563 pc(s). 8 pc(s)., pc(s)..73 kg Specific technical data Type Output current Min. forward voltage Max. forward voltage Max. output power Typ. power consumption (at 3 V, 5 Hz, full load) Typ. current consumption (at 3 V, 5 Hz, full load) Efficiency (at 3 V, 5 Hz, full load) Efficiency (at 3 V, 5 Hz, min. load) Max. casing temperature tc Ambient temperature ta max. 7 ma 5. V 5. V 35 W 4 W 8 ma 87.5 % 83.5 % 7 C -... +5 C open C 35W 7/8/5mA flexc SR ADV 8 ma. V 44. V 35 W 4 W 8 ma 87.5 % 8.5 % 75 C -... +5 C - ADV Type A,5 ma 6.5 V 33.5 V 35 W 4 W 9 ma 86. % 8. % 75 C -... +5 C - ADV Type A Test result at,5 ma. Output current is mean value. 3 Test result at 5 C. 4 Type A is a short circuit plug ( Ω). 5 Test result at default output current. I-out Resistor 4 www.tridonic.com
ACCES- SORIES ADV Plug for output current Product description Ready-for-use resistor to set output current value Compatible with ED Driver serie C flexc ADV; not compatible with I- (generation ) and I- (generation ) Resistor is base isolated When using your own resistors, make sure the resistor must be isolated Resistor power.5 W Current tolerance ± % additional to output current tolerance Hot plug of the resistor is not permitted For detailed current setting see table Specific technical data of the respective ED Driver and chapter 3.8 Current setting Ordering data Type Article number Colour of X area Colour of Y area X Y 9 Marking 5,5 4,5 xxxx xxxx 7,5 3,5 Resistor value 3,5 Packaging bag Weight per pc. ADV Plug Type A Y 877 Yellow Yellow A, Ω pc(s).. kg www.tridonic.com 3
. Standards E 555 E 6598- E 6-3- E 6-3-3 E 6347- E 6347--3 E 6547 E 6384. Glow wire test according to E 6347- with increased temperature of 85 C passed. Secondary wires (ED module) The output wiring can be done with a cross section of.5.5 mm². Strip 8.5 9.5 mm of insulation from the cables to ensure perfect operation of the push-wire terminals. wire preparation:.5.5 mm² 8.5 9.5 mm 3.3 oose wiring Press down the push button and remove the cable from front.. Thermal details and life-time. Expected life-time Expected life-time Type Current ta 4 C 5 C 7 ma tc 6 C 7 C ife-time 5, h 3, h C 35W 7/8/5mA flexc SR ADV 8 ma,5 ma tc 65 C 75 C ife-time 5, h 3, h tc 65 C 75 C ife-time 5, h 3, h The ED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than %. 3.4 Fixing conditions Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire. Is not suitable for fixing in corner. 3. Installation / wiring 3. Circuit diagram euchte uminaire > mm > mm >5 mm 4 V 5/6 Hz The ED module and all contact points within the wiring must be sufficiently insulated against 3 kv surge voltage. ED 3. Wiring type and cross section + + ED ED ô ô SEC PRI C... SR ADV Mains supply wires The wiring can be in stranded wires with ferrules or solid. For perfect function of the cage clamp terminals the strip length should be 4 5 mm for the input terminal. The max. torque at the clamping screw (M3) is. m. 3.5 Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Mains leads should be kept apart from ED Driver and other leads (ideally 5 cm distance) Max. lenght of output wires is m. Incorrect wiring can damage ED modules. To avoid the damage of the Driver, the wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). The current ion has to be installed in the accordance to the requirement of low voltage installation. Through wiring of mains is for connecting additional ED Driver only. Max. permanent current of 3 A may not be exceeded. max. =. mm min. =. mm.5.5 4 5 3.6 Replace ED module. Mains off. Remove ED module 3. Wait for seconds 4. Connect ED module again Hot plug-in or output switching of EDs is not permitted and may cause a very high current to the EDs. www.tridonic.com 4
3.7 Current setting 7 ma: All terminals open 8 ma: Terminal and connected with Ω wire (max. 6 cm length) or resistor ADV Plug Type A BR (article number: 877) ADV Type A + ED ED + ED ED 4. Power factor vs load Power factor,99,98,97,96,95,94,93,9 5 6 7 8 9 4.3 Input power vs load 45,5 ma: Terminal and connected with Ω wire (max. 6 cm length) or resistor ADV Plug Type A BR (article number: 877) ADV Type A 3.8 Mounting of device + ED ED Input power [W] 4 35 3 5 5 5 6 7 8 9 Max. torque for fixing:.5 m/m4 4. Electrical values 4.4 Input current vs load Test at 3 V 5 Hz. 4. Efficiency vs load Efficiency [%] 9, 89, 87, 85, 83, 8, 79, 77, 75, 5 6 7 8 9 Input current [ma] 75 5 5 75 5 6 7 8 9 www.tridonic.com 5
4.5 THD vs load THD [%] 9 8 7 6 5 4 3 5 6 7 8 9 7 ma 8 ma 5 ma 4.6 Maximum loading of automatic circuit breakers Automatic circuit breaker type C C3 C6 C B B3 B6 B Inrush current Installation Ø.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm.5 mm Imax Time C 35W 7/8/5mA flexc SR ADV 4 5 63 8 4 3 38 48 5 A 3 µs 4.7 Harmonic distortion in the mains supply (at 3 V / 5 Hz and full load) in % THD 3. 5. 7. 9.. C 35W 7/8/5mA flexc SR ADV < < 6 < 4 < 3 < < 5. Functions 6. Miscellaneous 5. Short-circuit behaviour In case of a short circuit on the output side (ED) the ED Driver switches off. After elimination of the short-circuit fault the ED Driver will recover automatically. 5. o-load operation The ED Driver works in burst working mode to provide a constant output voltage regulation which allows the application to be able to work safely when ED string opens due to a failure. 5.3 Overload protection If the output voltage range is exceeded the ED Driver will protect itself and ED may flicker. After elimination of the overload, the nominal operation is restored automatically. 5.4 Over temperature protection The ED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded, the Driver switch off. It restarts automatically. The temperature protection is activated typically at C above tc max. 6. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 6598- Annex Q (informative only!) or EEC 33-Annex A, each luminaire should be submitted to an isolation test with 5 V DC for second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least MΩ. As an alternative, IEC 6598- Annex Q describes a test of the electrical strength with 5 V AC (or.44 x 5 V DC). To avoid damage to the electronic devices this test must not be conducted. 6. Conditions of use and storage Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -4 C up to max. +8 C The devices have to be within the specified temperature range (ta) before they can be operated. 6.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services ife-time declarations are informative and represent no warranty claim. o warranty if device was opened. www.tridonic.com 6