Energieverbrauch von Netzwerkkomponenten

Similar documents
IT CONTINUITY, BACKUP AND RECOVERY POLICY

Vendor Questions and Responses Ongwanada RFP #08-06

The Solution Requirements and considerations

Higher National Unit specification: general information

Internet Architecture and Protocol

19CSP075 Broadband Network Upgrade. Appendix C Final Acceptance Checklist (Example) Site Name: Inspector Name: Inspection Date: Acceptance Signature:

White paper adaptive IT infrastructures

Switch to Perfection

Network Service Assurance

ANSI/TIA/EIA-568-B Cabling Standard

Configuring Network Proximity

Internetworking Switching and Routing MODULE LEVEL 7 MODULE CREDIT POINTS 30 SI MODULE CODE (if known) Computer Systems & Networks

QINEO DATA MANAGER. Perfect welding machine management

NZQA unit standard version 2 Page 1 of 6. Demonstrate basic knowledge of telecommunications concepts

1 Energy Efficient Protocols in Self-Aware Networks

THE INTERCONNECTED NETWORK

Cisco CISCO Data Center Networking Infrastructure Design Specialist. Practice Test. Version

GPON Gigabit Passive Optical Network

WRTU54G-TM. Release Notes. Software Version (Maintenance Release 9) Wireless Router with Home Phone Adapter

Lecture: Chapter 1, Introduction to Computer Data

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

Module 15: Network Structures

Questions and Answers for Request for Proposal #03588

Contents. One Introduction 2. Two Installation 3 Front Panel Connecting Ports LEDs

CoolAVR TM New 3 rd party SCADA system For Basler DECS excitation control systems

S5 Communications. Rev. 1

Distributed System Chapter 16 Issues in ch 17, ch 18

Communication Technologies

GETTING CONNECTED Installation instructions for your NBN Modem Sagemcom 5356

ANLEITUNG / MANUAL EMU ALLROUNDER EMU PROFESSIONAL. Quality that counts. Made in Switzerland

Higher National Unit specification: general information

IT Services Performance Report

Chapter 4: Network Access. Introduction to Networks v5.1

Network+ Guide to Networks 7 th Edition

Master of Engineering in Internetworking Laboratory Guide

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

Booking a space on campus through Resource Booker

University of San Francisco Course Syllabus and Outline

PRACTICAL ROUTERS and SWITCHES for ENGINEERS and TECHNICIANS

MDC-20. Maximum Demand predictive Control. Description

Applied Information and Communication Technology

The Threaded Case Study

Gigabit-capable Passive Optical Networks (G-PON): Physical Media Dependent (PMD) layer specification Amendment 2

Preparing for JT Fibre

Internetworking Basics

SIMEAS Q80 quality recorder: Voltage quality starts with measurement.

Configuring Online Diagnostics

Peter Sharp RCDD IBI Group

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

WAN/MPLS SLA Fault Reporting

Data Communications. Connecting Devices

Planning a Green Datacenter

Level 1 Interconnection Services at MIX Annex A Technical and Organizational Specifications

A network is two or more computers, or other electronic devices, connected together so that they can exchange data.

Minnesota No-Fault Arbitration A Guide to the AAA s New Online Scheduling System Effective June 1, 2018

Senior Technical Consultant

Applications & Tools. Configuration Examples for SIMATIC S7-400H with PROFINET. SIMATIC S7-400H as of V6.0. Application Description January 2013

IT 341 Fall 2017 Syllabus. Department of Information Sciences and Technology Volgenau School of Engineering George Mason University

Chapter 9 Introduction to Networks

Module 16: Distributed System Structures. Operating System Concepts 8 th Edition,

Discussion of GPON technology application in communication engineering Zhongbo Feng

SCS. PoE Technology. - Milind Tamhane Vice President Manufacturing D-Link (India) Limited D-Link (I) Ltd. All rights reserved.

Fig. 1 Voice and data growth

Excel Power Distribution

Comparison Of Network Topologies For Optical Fiber Communication

This course prepares candidates for the CompTIA Network+ examination (2018 Objectives) N

Diagnosing Network Connectivity Problems

Lab Subnetting Network Topologies (Instructor Version)

QUALITY OF SERVICE AND THE EFFECTS OF DATA ENCRYPTION ON VSAT NETWORKS (GOVERNMENT NETWORKS)

Bob Warden. IP Metering and the Smart Grid WAN Revolution October 27, 2008

List of Abbreviations

UNIT OUTLINE. Network Engineering 304. Mr Iain Murray. Department of Electrical and Computer Engineering Curtin Engineering

ADC KRONE. Data Centre Design Considerations. TrueNet Engineered for Uptime

Introduction to Computer Networks INTRODUCTION TO COMPUTER NETWORKS

Trying to save power and putting Gigabit to the edge

Room Booking Instructions

ECM-1220 User s Manual

289H LSS Installation & Operations Manual Overview

iscsi Technology Brief Storage Area Network using Gbit Ethernet The iscsi Standard

Listing Space & Serviced Office Gotthardstrasse 26, 6300 Zug

Application Note. Data Center Standards and Layouts

COMPUTER NETWORKING. By: Dr. Noor Dayana Abd Halim

Silicon Valley Power Data Center Program Rebate Application

BCS THE CHARTERED INSTITUTE FOR IT BCS HIGHER EDUCATION QUALIFICATIONS BCS Level 5 Diploma in IT COMPUTER NETWORKS APRIL 2015 EXAMINERS REPORT

Provisioning: Configuring QoS for IP Telephony

LinchPin. Managed Service For IP VPN Networks. Web Site Telephone

PART IV. Internetworking Using TCP/IP

All configuration in this document refers to the EZ Setup section.

EXECUTIVE SUMMARY. Our Pedigree

Special Provision No. 683S27 June 2017

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

BUILDING AUTOMATION OF THE FUTURE

Ethernet DIA SLA Fault Reporting

Configuring UDLD. Understanding UDLD CHAPTER

ECE 333: Introduction to Communication Networks Fall 2001

E-Seminar. Storage Networking. Internet Technology Solution Seminar

Low Profile Hub. User Manual

Syllabus Revised 08/21/17

Jewish Federation of Metropolitan Chicago. Author DP 3/23/2010 5/17/2010 2/6/2012 Reviewer Approver Publisher

Transcription:

Bundesamt für Energiewirtschaft Forschungsprogramm Elektrizität ENGLISCHE VERSION Energieverbrauch von Netzwerkkomponenten Messbericht

Verteiler: 26/11/97 MK Ingenieure und Planer AG, Mitglied SIA/ASIC Forchstrasse 395, CH-8029 Zürich, Telephon 01 /387 11 22, Telefax 01 /387 11 00

Contents Abstract 1 1. Objectives and procedures 1 2. Description of networks 2 2.1 Topology of B&H network, Rehalp/Esslingen 2 2.2 Topology of SIG network, Geneva 2 3. Measurement concept 3 3.1 Structure of measurements / analyzed devices (B&H) 3 3.2 Structure of measurements / analyzed devices (SIG) 6 4. Results 7 4.1 Weekly & daily measurements (B&H) 7 4.2 Weekly measurement (SIG) 9 Measurement 1 (B&H, Rehalp EDP centre) Measurement 2 (B&H, Rehalp PABX centre) Measurement 3 (B&H, Esslingen EDP centre) Measurement 4 (SIG, Geneva, EDP centre) 5. Implementation 33 6. Acknowledgements 33 Appendices 35 Distribution list:messers Brüniger, Kistler, Huser, members of supporting group 26.11.1997, E Version 1, 2522.00 MK/CF/sf Ingenieure und Planer AG, Mitglied SIA/ASIC Forchstrasse 395, CH-8029 Zürich, Telephon 01 /387 11 22, Telefax 01 /387 11 00

Abstract Measurements of electricity consumption of network components (router, switch, multiplexer, micro repeater, media converter) were carried out in two modern networks with 82 and 1200 users respectively. It was established that the recorded power was constant in terms of time and does not depend on the data-flow quantity or network topology. The measured power was approx. 30% of the specifications in the product descriptions, and this could give rise to an over-dimensioning of infrastructure systems such as air-conditioning plants and uninterruptible power supply (UPS) units. 1. Objectives Goal The goal of this project is to record the electricity consumption of active network components and list initial criteria for improving energy efficiency. To achieve this, the electrical supply of major network components (switches, routers, multiplexers, micro-repeaters and media converters) was measured in an Ethernet and an ATM network. Procedure Measurements of the electrical power of network components were carried out during periods of high (daytime) and low (night-time) network system loads. The measurements were carried out on two networks: Basler & Hofmann (CISCO products) and Service Industriels de Genève (BAY products), in collaboration with Basler & Hofmann and Teleinform. 1

2. Description of networks 2.1 Topology of Rehalp / Esslingen network (B&H) Description of topology This description covers the application of the examined components in the B&H network: - The topology of Rehalp corresponds to that of Esslingen. A switch (2901) is used in the backbone, to which the individual storey switches are connected. The individual segments have been set up according to 10Base2 standard and linked via media converters (transceivers) with the storey switch (2802). - In the Esslingen topology, the storey switches (2802) are linked with the backbone switch (2901) via fibre. Since the CISCO switch does not possess any fibre ports, the individual uplinks opto-converters (transceivers) are pre-switched. (See diagram in Appendix A) Cabling, Rehalp In Rehalp, the cabling has been carried out by means of ThinWire-Ethernet. The individual strands are fed to distributors which are connected to the central node in the server room by means of fibre. Cabling, Esslingen In Esslingen, universal cabling infrastruction was used for wiring the building. The central node point is located in the server room. The storeys are cabled using fibre, and the individual storeys are linked via copper (category 5) from the distributors located on each storey. 2.2 Topology of (SIG) network, Geneva Description of topology The ATM backbone of the SIG network consists of 8 Centillion 100 and a number of 5000DN models manufactured by Bay Networks. For redundant reasons, two ATM C100 switches have been installed in the computer centre. The C100 switches in the basement and 3 rd storey provide switched Ethernet connections to the 5000DN Bay model. An ATM router (VNR) permits connection between the various virtual LANs. (See diagram in Appendix B). 3. Measurement concept 3.1 Structure of measurements / measured equipment in B&H network Overview 2

The tested components are depicted in colour in the B&H Network Topology diagram in Appendix A. Measurement 1 (yellow) Components Measurement 1 was carried out in the server room (SS) Rehalp: - CISCO 2514 router (VAX link) - CATALYST 2802 switch (storey switch) - CATALYST 2901 switch (backbone switch) - MR micro-repeater 122T transceiver Media converter Measurement 2 (green) Measurement 2 was carried out in the PABX centre (basement), Rehalp: - CISCO 2503 router (Esslingen link) - CISCO 2503 router (Internet link) IDNX Micro20 multiplexer (WAN link) Measurement 3 (blue) Measurement 3 was carried out in the server centre (basement), Esslingen: - CISCO 2503 router (Rehalp link) - CATALYST 2901 switch (storey switch) - IDNX Micro20 multiplexer (WAN link) Echo cancellor Choice of components Throughout the world, approximately 88% of Internet links use CISCO routers. Of these, some 60% concern the CISCO 2500 model (personal guess from M. Kistler). This indicates that the measurements were carried out on the most widely-used type of router. Measuring devices Each active component is connected to two measuring devices. This redundant method of measuring serves as a cross-comparison for precise measurement as well as helping to verify the measurement. The evaluation of the measurements was mainly based on the readings at the electrical clamps. Device 1 Connection of the clamps to the measuring wires, and link to a data logger. Device 2 Connection of EMU 1.x1M measuring device via direct wiring to the various components. Both measuring arrangements were transferred to a laptop via an interface, and recorded and displayed in table form. 3

Diagram of measuring arrangement Arrangement Duration of measurement Measurement cycle The intention was to carry out two measurements: Daily measurement: Measurement was carried out in the smallest possible intervals of 1 second. The readings were averaged, stored and recorded every 30 seconds. Weekly measurement: Measurements were carried out in the smallest possible intervals of 1 second. The readings were averaged, stored and recorded every 5 minutes. With both cycles, the maximum and minimum levels were also recorded for each active component. Evaluation For each of the three measurements an average was calculated using the integral. The course of the measurements was recorded graphically and the power was shown in watts [W]. Comparisons were made between the same components in the different topologies. Measurement periods Measurement 1 June 12 to 23, 1997 Measurement 2 July 24 June to 2, 1997 Measurement 3 July 2 to 11, 1997 Measured variable 4

Variable measured with the Chauvin Arnoux clamps: output 100 mv (=) / A (- ). With EMU energy metres, the variable was measured in kwh. 5

3.2 Structure of measurements and examined SIG devices Overview The measurement is depicted in colour in the SIG Network Topology in Appendix B. Components Measurement 4 (red) Measurement 4 was carried out in the computer centre of Service Industriels de Genève. Measurement period Measurement 4 June 23 to 30, 1997 6

4. Results 4.1 Weekly and daily measurements (B&H) Measurement capacity Explanations It was possible to measure five devices simultaneously. Measurement 1 It was only possible to use five channels for controlling the measurements obtained at the clamps. Only five EMU devices were available for carrying out measurements. Measurement 3 It was not possible to feed the IDNX multiplexer via an EMU for carrying out measurements. Similar readings as for measurement 2. Accuracy of EMU These devices are capable of measuring currents up to 32 A. The EMU is classified in precision category 2, i.e. +/- 0.5% tolerance. Accuracy of clamps The clamps used are capable of measuring currents up to 150 A. Their tolerance is 3%, though clamps show a greater deviation tendency with very low current levels. Power consumption Results, B&H network The results of the measurements were as follows The power consumption of the devices in permanent operation remains practically constant, regardless of the data-flow quantities, time of day or day of the week. It should also be noted that no significantly greater consumption fluctuations occur at weekends. The power consumption of the individual devices does not depend on the topology in which they are used. The readings obtained are approximately equivalent to 30% of the specifications indicated in the product descriptions. Comparison, B&H The table below shows the components used in the Basler & Hofmann network: 7

Model Indicated power Measured power Micro-repeater Media converter 3W 6W Catalyst 2802 switch 110W 40W Catalyst 2901 switch 264W 80W CISCO 2503 router 40W 15W CISCO 2514 router 40W 15W IDNX multiplexer 400W 110W Echo cancellor 12W In connection with these comparisons it should be noted that the components are not completely installed, but the power supply is indicated for completion installation. Comparison of power, Basler & Hofmann Work-desk devices Servers Active components Active components 30.0 kw, 10 hrs/day operation 1.5 kw, 24 hrs/day operation 2.3 kw (specified), 24 hrs/day operation 1.0 kw (measured) Since work-desk devices are switched off at night, their operating time is reduced, and their energy consumption is correspondingly lower. The proportion of the network components in the Basler & Hofmann network that was tested is equivalent to around 15% of the total annual consumption of the network. Significance Throughout Switzerland, operators of networks should be made increasingly aware of the annual energy consumption of network components. This means 8

that the application of energy management systems in networks should be more actively promoted. 4.2 Weekly measurement (SIG) Measurement 4 Explanations For cost reasons, Teleinform was unable to carry out daily measurements. No EMU devices were used in Geneva for cross-comparison purposes. Comparison, SIG The table below shows the components used in the Service Industriels de Genève network Mode 1 Indicated power Measured power ATM switch 300/600W 130W (redundant power supply) Bay model 950W 170W Power consumption Results, SIG network The results of the measurements were as follows: The power consumption of the devices in permanent operation remains practically constant, regardless of the data-flow quantities, time of day or day of the week. It should also be noted that no significantly greater consumption fluctuations occur at weekends. The power consumption of the individual devices does not depend on the topology in which they are used. The readings obtained are approximately equivalent to a quarter to a third of the specifications indicated in the product descriptions. With the Bay 5000 DN, the difference between specified and measured power is even more pronounced. 9

Measurement 1 Basler & Hofmann (Rehalp, EDP centre) 10

11

12

13

14

15

Measurement 2 Basler & Hofmann (Rehalp, PABX centre) 16

17

18

19

20

21

Measurement 3 Basler & Hofmann (Esslingen, EDP centre) 22

23

24

25

26

27

Measurement 4 Service industriels de Genève (computer centre) 28

29

30

31

5. Implementation Data The measurement data should be submitted to the two manufacturers (Cisco and Bay) for examination and evaluation purposes. In the same connection, the manufacturers should also be queried about possible developments. Should any relevant power variations exist between the manufacturers, a labelling procedure could be introduced in the same way as for end devices. Components which meet the criteria would be awarded a quality label, which would enhance transparency on the market. 6. Acknowledgements Swiss Federal Office of Energy At this juncture we wish to thank the Swiss Federal Office of Energy as principal for incorporating Basler & Hofmann into this project. Teleinform We would also like to thank Teleinform for its valuable assistance in connection with the various measurements carried out on the B&H network. Support group We received valuable tips and assistance from Messrs R. Bruniger and A. Huser. 32

33

Appendices A Diagram: Topology of B&H network B Diagram: Topology of SIG network 34

35

36