GN1600 F1 Network Storage System Quick Specification

Similar documents
AN1600 F1 Network Storage System Quick Specification

Acer AR320 F2 Specifications

GW2000h w/gw175h/q F1 specifications

Acer AR320 F1 specifications

Acer AT310 F2 Specifications

Acer AN1600 F1 Network Storage System Specifications. Product Front view

Acer AT110 F2 Specifications

Altos T310 F3 Specifications

Acer AC100 Server Specifications

GW2000h w/gw170h/d/q F1 specifications

Altos R320 F3 Specifications. Product overview. Product views. Internal view

GR585 F1 specifications

Acer AW2000h w/aw170h F2 Specifications

Acer AT115 F1 Specifications

NEC Express5800/R120e-1M System Configuration Guide

Acer AR320 F1 Specifications. Product Front View

Acer AW2000ht w/ AW170htx F1 Specifications

NEC Express5800/R120d-2M Configuration Guide

Acer AR160 F1 Specifications. Product Front View

Acer AW2000h w/ AW170hx F1 Specifications

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Cisco Connected Safety and Security UCS C220

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco UCS C200 M2 High-Density Rack-Mount Server

NEC EXPRESS5800/R320a-E4 Configuration Guide

Acer AR380 F1 Specifications. Product Front View

NEC Express5800/R120e-2E Configuration Guide

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

NEC EXPRESS5800/R320b-M4 Configuration Guide

Cisco MCS 7835-H2 Unified Communications Manager Appliance

NEC EXPRESS5800/R320a-E4 Configuration Guide

Cisco UCS C24 M3 Server

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide

Intel IP Network Server NSI2U

Fujitsu PRIMERGY TX100 S2 Server

Pegasus 5 Series. Ernitec Smart Backup. Massive Power. Optimized for Surveillance. Battery Backed 12Gbps Raid Controller.

NEC Express5800/R120h-2E System Configuration Guide

NEC Express5800/R120f-1M System Configuration Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

High Performance Computing

NEC EXPRESS5800/GT110d-S Configuration Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

The Cisco MCS 7835-H2 can run any of the following Cisco applications:

B A. AW3000 Front View

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

Cisco MCS 7825-I1 Unified CallManager Appliance

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

NEC Express5800/B120f-h System Configuration Guide

Cisco MCS 7825-H3. Supported Cisco Applications

NEC Express5800/B110d Configuration Guide

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

NEC EXPRESS5800/E110d-1 Configuration Guide

NEC Express5800/R120d-1M Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC Express5800/GT110e Configuration Guide

Figure 1 shows the appearance of Huawei FusionServer RH8100 V3 Rack Server. The RH8100 V3 provides three front I/O modules:

NEC EXPRESS5800/R320c-M4 Configuration Guide

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

NEC Express5800/D120h System Configuration Guide

NEC Express5800/GT110e-S Configuration Guide

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

NEC EXPRESS5800/R140b-4 Configuration Guide

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Data Sheet PRIMERGY RX330 S1. Dual Socket Quad-Core AMD Opteron 2000 series based Rack Server - Standard server with high performance at low price

Cisco MCS 7816-H3 Unified Communications Manager Appliance

Cisco MCS 7815-I2 Unified CallManager Appliance

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

NEC Express5800/R120h-1M System Configuration Guide

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

SUN SERVER X2-4 SYSTEM

NEC Express5800/B120e-h System Configuration Guide

Data Sheet Fujitsu Server PRIMERGY CX250 S2 Dual Socket Server Node

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

NEC Express5800/GT110e-S Configuration Guide

ftserver 3300 Service Bulletin

Data Sheet Fujitsu PRIMERGY TX100 S3 Server

HP ProLiant DL360 G7 Server - Overview

Streamlined feature-rich ATX UP serverboard. The most scalable I/O expandability

Data Sheet Fujitsu PRIMERGY RX4770 M2 Server

Data Sheet Fujitsu PRIMERGY TX100 S2 Server

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Change Log. 05/16/2014 Original release 2014 LENOVO. ALL RIGHTS RESERVED.

Acer AB2x280 F1 Server Blade Specifications

Cisco HyperFlex HX220c M4 Node

Intel Entry Server Board SE7221BA1-E

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

NEC Express5800/T110h-S System Configuration Guide

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

Oracle Database Appliance X6-2L

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

QuickSpecs HP ProLiant ML150 Generation 2

NEC Express5800/R120h-1E System Configuration Guide

Xcellis Workflow Extender (R520) Site Planning Guide

NEC Express5800/B120d-h System Configuration Guide

Transcription:

Product Overview Gateway GN1600 F1 storage system is a cost-effective storage solution, powered by Microsoft Windows Storage Server offering an easy way for storage centralization, file sharing, data protection, and remote access. Processors and chipset 2 x Intel Xeon E5620 processors (2.4 GHz, 12 MB L3 cache, 5.86 GT/s, DDR3-1066, 80 W, HT) Intel 5520 Chipset Memory Type DDR3-1333 Registered (R) with ECC capabilities Maximum memory by O/S 32 GB # of sockets 12 Minimum (standard) memory on 6 GB (2 GB x 3) system Network controller Integrated Intel 82576EB dual-port Gigabit Ethernet controller Storage 1 Maximum capacity Up to 12 x 3.5" Hot pluggable SAS/SATA HDD capacity Up to 24 TB raw internal SATA Up to 7.2 TB raw internal SAS Minimum capacity 300 GB x 2 internal SAS HDD External storage Optional 2 Storage controller LSI SAS MegaRAID SAS PCIe 2.0 x16 9260-16i with 16-internal ports, 512 MB, supporting RAID 0/1/10/5/50/6/60 Expansion slots Seven PCI-Express slots Two PCI-Express Gen 2.0 x8 slots (in x4 connector; left) One PCI-Express Gen 2.0 x16 slot (in x8 connector left) Three PCI-Express Gen 2.0 x8 slots (in x4 connector; right*) One Gateway Flex I/O (PCIe Generation 2.0 x8 connector (left) *Right hand side PCI-Express space has limitation for low-profile card, length within 5.6 Operating System Microsoft Windows Storage Server 2008 R2, Standard x64 edition Management Gateway Smart Console Gateway Smart Server Manager 1. Storage capacity depends on sku selected 2 External storage is available through fiber channel connection for additional storage devices 1

ibmc management controller, supporting base board management and KVM-over-IP LSI MSM (MegaRAID Storage Manager) on-line utility is the OS level utility for data volume RAID configuration LSI WebConsole utility is a ROM-based utility provided by HBA FW for data volume RAID configuration Windows Disk Management is OS built-in feature on Windows Storage Server 2008 R2 Microsoft Windows Storage Server Administration Tools Deployment/serviceability BIOS Update Tool IPMI Firmware Update Tool Input/output interface Front Rear Power button HDD activity indicator LED PSU failure LED PS/2 Mouse port Serial port Two Gigabit LAN ports (RJ-45) Power indicator LED Two LAN activity LEDs (LAN1, LAN2) System status/fault indicator LED Two USB 2.0 ports Video port ID LED button Chassis/form factor Management port (RJ-45) (dedicate management NIC) 2U rack optimized up to 12 hot-pluggable 3.5" SAS/SATA HDDs Power supply 2 x 720 W 80 PLUS Gold level efficiency power supply (redundant/ hot-plug) Regulatory compliance standards EMC CE (Class A) Safety CB GS Dimensions 438.4(w) x 705 (D) x 88.1 (H) mm (17.26 x 27.76 x 3.47 inches) Form factor 2U rack optimized 2

Product Overview 1. PCIe/Flex I/O expansion 7 slots in total 2. Riser card supporting PCIe, PCI (LAN card), and Flex I/O expansion 3. Intel Xeon processor 5600 series 4. 12 DDR3 dual-channel s (6 per CPU), ECC support 3 5. 2 x 720W 80 PLUS Gold level efficient PSU (1+1 redundant/hot pluggable) 6. 3+1 redundant system fans 7. SAS/SATA backplane 8. Front status indicators and power button 9. 12 hot-pluggable 3.5 SAS/SATA HDDs 3 Maximum memory capacity is 32 GB per system by Operating System. 3

What s New in GN1600 F1 1. Windows Storage Server R2 Friendly User Interface Customization Standard-alone NAS OOBE Single Instance Storage Performance improvement SCOM management pack support isci software version 3.3 Performance improvement SCOM management pack support Bitlocker BranchCache-Hosted Cache support Additional language support 2. 16 port RAID card support Pre-configured skus 1 Processor Memory Type HDD RAID HBA 1 E5620 6 GB Stand-along storage 2x 300 GB SAS LSI MegaRAID 9260-16ix1 2 E5620 6 GB Stand-along storage 2x 600 GB SAS LSI MegaRAID 9260-16ix1 3 E5620 6 GB Stand-along storage 2x 1 TB SATA LSI MegaRAID 9260-16ix1 4 E5620 6 GB Storage gateway 2x 2 TB SATA LSI MegaRAID 9260-16ix1 1. 16-port 6 Gb/s SAS RAID adapter is now available for FG SKU starting from January, 2011 Features and Benefits Unified storage acting as file server Centralized information keeper in network with Microsoft based storage operating system to manage, protect, and expand. Efficient operations Expansion as needed and stay in storage industry standards SME budget with enterprise storage level features Works together with Gateway Smart Setup and Gateway Smart Manager for faster installation and setup. Microsoft Management Console user interface from Windows storage operating system enable you to use existing features such as iscsi and SIS 4 allowing less maintenance and faster backup. Leveraging industry HDD standards SAS/SATA standards and extend to external storage through fibre channel connections. Powered by latest Intel processors and DDR3 memory protecting your investment and resources years to come. Designing from server infrastructure by using server processors, industry standard HDDs, interconnections, DDR3 memory, and hot-plug 4 SIS: Single Instance Storage can recover up to 35% of disk capacity by reducing the number of redundant files. 4

redundant power supply, GN1600 F1 is equipped with enterprise level features such as file de-duplication, snapshots, and distributed file system replication. 5

Standard Features Gateway Smart Server Manager Offers 24-7 monitoring for system health and performance. Delivering proactive event management features including system event logging, event handling from e-mail and SNMP Trap (PET) alerting. Allowing remote control from KVM and Power control. Satisfying management in web-based UI, role-based administration, and automated management scripts. Gateway Smart Console Web-based management utility to simplify system management with embedded ibmc System monitoring and alerting, event handling, remote power control and KVM-over-IP. Gateway Smart Console is OS independent, and offers virtual media through floppy, ODD, and removable disk. Out-of-band (OOB) management regardless OS status. Gateway Recovery Utility A friendly and an intuitive system recovery utility to return to its original factory state. Supports over twenty some different languages. Wizard step by step guiding through the complete recovery processes. Gateway Resource Kit Comprehensive system information in one single disk including System drivers, LAN, RAID, and iscsi Target Client utilities, and User Guide. GN1600 F1 features Windows Storage Server R2 Operating System Microsoft Windows Storage Server 2008 R2, Standard x64 Edition operating system provides file storage and print server capabilities for client and server computers in your network environment. Storage appliances running Windows Storage Server 2008 R2 can be used in failover clusters, providing high availability storage for application servers and file storage. Single Instance Storage (SIS) v2 File Server Optimization Remote Administration in Heterogeneous Environments SIS reduces the amount of storage used by data by replacing multiple identical copies with logical links to a single source copy. Windows Storage Server 2008 R2 is tuned to provide better performance in a file server role, realizing as much as an 8% performance gain in file system operations. Remote administration of Windows Storage Server 2008 R2 appliances can be done from Internet Explorer using an ActiveX control, and from non-microsoft browsers using a Java control. 6

Print Services Windows Storage Server 2008 R2 offers performance enhancements for the Print Services role. Distributed File System (DFS) Namespace and Replication Windows Storage Server 2008 R2 can provide DFS support for file sharing for WANs and satellite offices Microsoft iscsi Software Target Microsoft iscsi Software Target provides centralized, software-based and hardware-independent iscsi disk subsystems in storage area networks (SANs). You can use iscsi Software Target, which includes a Microsoft Management Console (MMC) snap-in, to create iscsi targets and iscsi virtual disks. You can then use the Microsoft iscsi Software Target console to manage all iscsi targets and virtual disks created using iscsi Software Target. Microsoft iscsi Software Target 3.2 provides the following features: Server Manager Integration Improved CHAP Secret Storage ERL0 Compliant Manage your Microsoft iscsi Software Target from Server Manager. Microsoft iscsi Software Target 3.2 uses a more secure and customizable storage method for CHAP secrets. Connection and session reinstatement is now fully ERL0 compliant. Microsoft Management Console Microsoft Management Console (MMC) is an extensible common presentation service for management applications. MMC unifies and simplifies day-to-day system management tasks. It hosts tools and displays them as consoles. These tools, consisting of one or more applications, are built with modules called snap-ins. The snap-ins also can include additional extension snap-ins. Microsoft Management Console enables system administrators to create special tools to delegate specific administrative tasks to users or groups. Microsoft provides standard tools with the operating system that perform everyday administrative tasks that users need to accomplish. Task Orientation Integration The tools being defined to work with MMC are task oriented in nature they cater to the task being performed rather than merely displaying the raw objects that can be manipulated. Also, because administrators can customize their own tools, using pieces from various vendors, they can create tools that contain only the UI they need to complete their tasks. The UI for all the management tasks an administrator must perform are collected into a single console. As new applications are added to a computer or network, their administration is integrated into the existing administration common console. 7

Customization of Consoles Administrators can create custom consoles tailored to their particular management needs. This is useful in enterprise environments that divide administrator groups according to duties. For example, you can create a custom console for software installation and maintenance, another one for scripts administrators, another one for security Group Policy, and so on. Delegation Overall Interface Simplification Extensibility Administrators can easily modify existing tools to create new tools with reduced functionality and less complex views of the tool namespace, and then give these tools to others. A person who receives such a tool is presented with a simpler, more manageable view of the tasks they are being asked to perform. All tools built for MMC, from Microsoft or third-party software vendors, will have a similar appearance, making it easier for users to use all tools after learning one. Because you can mix and match tools from any vendor, you can use the best tool from each management product category. MMC also enables a single piece of software to provide functionality across the interface in a consistent manner. Developers can extend the base functionality of MMC snap-ins by creating extension snap-ins. This allows software vendors to reuse Microsoft tools without writing a lot of code. Various mechanisms are available for extending snap-ins, including extending the namespace, context menus, toolbars, Property pages, and creating Wizard 97-style pages. System Specifications Processor Type Two Intel Xeon E5620 DP Quad-Core (2.4 GHz, 12 MB L3 cache, 5.86 GT/s, DDR3-1066, 80 W, HT) Features Socket Intel QuickPath Interconnect up to 6.4 GT/s, each direction. Per link Support Intel 64 Technology, Enhanced Intel SpeedStep Technology, Intel Simultaneous Multi Threading, Intel Virtualization Technology Support Registered LV DDR3 Two LGA1366 sockets 8

NOTE: 1. For optimum performance, when two processors are installed, both must be of identical revision, core voltage, and QPI/core speed. When only one processor is installed, it must be in the Processor Socket 1. The other socket must be empty. Processors must be populated in sequential order. Processor Socket 1 must be populated before Processor Socket 2. 2. System thermal solution is capable of supporting up to TDP 95W Intel Xeon 5600 EP processors. (include standard, HE) Cache Memory 12MB Shared L3 cache Chipset North Bridge Intel 5520 Chipset South Bridge ICH10R Memory Type DDR3 1066/1333MHz Registered memory sockets Twelve slots Capacity Maximum memory Minimum memory Memory Protection Registered : 1 GB, 2 GB, 4 GB Registered memory: 32 GB Registered meory: 6 GB ECC, Mirroring, Lockstep Mode, x8 SDDC, Sparing NOTE: 1. Support ECC, Independent channel ode, mirroring, sparing, sparing mode, lockstep mode, x4/x8 SDDC 2. Support memory scrubbing 3. Support Error reduction (BIOS will isolate the faulty and does not enable it when system detects the faulty 4. Event log/monitoring: Single/multi-bit ECC error 5. Mixing of Registered memory and Unbuffered ECC memory is NOT supported. Networking Controller Integrated single dual-port Intel 82576EB Gigabit Ethernet Controllers (Dual Port 10/100/1000) Ports 2 ports 9

Network interface Compatibility Virtualization acceleration Manageability Connector Cable support Data transfer method Network transfer rate 10Base-T / 100Base-TX / 1000Base-TX IEEE 802.3 Ethernet interface for 10BASE-T, IEEE 802.3ab Ethernet interface for 1000BASE-T, IEEE 802.3u Ethernet interface for 100BASE-TX, Intel I/O Acceleration Technology NC-SI, SMBus PXE, iscsi Boot RJ-45 CAT 5e wire One lane (x1) 10Base-T (half-duplex) 10 Mb/s 10Base-T (full-duplex) 20 Mb/s 100Base-TX (half-duplex) 100 Mb/s 100Base-TX (full-duplex) 200 Mb/s 1000Base-TX (half- and full-duplex) 2000 Mb/s Graphics Controller Integrated Matrox G200 graphics Embedded graphics controller (ibmc) Video memory 8MB Supported resolution 1440x900 32b@ 60Hz 8:5 aspect ratio 1280x1024 32b@ 60Hz 5:4 aspect ratio Storage Controllers Six on-board 3Gb/s SATA ports, 7-pin with RAID 0, 1, 5, 10 support Expansion slots Controller Left-side Riser: - 1 Flex I/O - 1 PCI-E x16 connector (w/ Gen2 x8 link) - 2 PCI-E x8 connector (w/ Gen2 x4 link) Right-side Riser: - 3 PCI-E x8 connectors (w/ Gen2 x4 link) 10

NOTE: 1. The signaling bit rate of PCI Express is 2.5Gbit/s one direction per lane for Gen 1 and 5.0 Gbit/s one direction per lane for Gen 2. 2. Indicates the number of physical electrical lanes running to a PCIe connector 3. Default bus assignment (in decimal). Inserting cards with PCI bridges may alter the actual bus assignment number. 4. Slots are enumerated differently based on the operating system. Microsoft operating systems enumerate Device ID by bus starting from the lowest bus to the highest. Back I/O Panel Two PS2 ports Two USB 2.0 ports Two RJ45 connectors (Dual Gigabit NIC) with Activity and Link indicators One RJ45 (dedicate management NIC) with Activity and Link indicators One Serial port (DB-9) One SVGA Video port (DB-15) System ID LED/Button NOTE: Parallel port is NOT supported Language Support English German French Italian Spanish Chinese (traditional) Yes Yes Yes Yes Yes Yes 11

Technical Specifications Form Factor 2U rack-optimized Dimensions (W x D x H) Weight Metric Units (mm) Imperial Units (inch) Maximum (all processors, memory, hard disk drives, power supplies installed) Minimum (Two processor, two PSU, single memory, no hard disk drive installed) 438.4 x 705 x 88.1 mm 17.26 x 27.76 x 3.47 inches 38.0 kg (84 lb) 27.5 kg (60.62 lb) Front Control Panel Power button Power indicator LED HDD activity indicator LED Two LAN activity LEDs (LAN1, LAN2) PSU failure LED System status/fault indicator LED Rear I/O bracket 2 x PS2 ports 2 x USB 2.0 ports 1 x Serial port 2 x RJ45 connectors (Dual Gigabit NIC) with Activity and Link indicators 1 x RJ45 (dedicate management NIC) with Activity and link indicators 1 x SVGA Video port (DB-15) 1 x ID LED button Storage On-board SATA Controller Intel 82801JR (ICH10R) I/O Controller Hard disk drive Form factor 3.5 Type Hot-plug SATA/SAS Hot-plug FDD Not support 3.5 SATA hard disk drive Maximum 24TB (12x 2TB 3.5 SATA HDD) Full Function / dummy carrier 12

Simulaneous drive transfer channels Transfer rate synchronous (maximum theoretical) 6 channels 3Gb/s per channel Data transfer method Non RAID mode RAID mode Drive support SAS/SATA Data transfer modes Legacy model Combined mode Protocol SAS/SATA Feature NCQ (Native Command Queuing) AHCI (Advanced Host Controller Interface) RAID (Redundant Array of Independent Disks) RAID level supported 0, 1, 5, 6, 10, 50, and 60 with hardware RAID adapter RAID feature Supports multiple logical volumes Setup through ROM based Array Configuration Utility Installation scripting support RAID OS support Windows Storage Server 2008 R2 Hard disk drive bays 3.5 hard disk drive Maximum: 12 bays Hot plug Interface PS2 Keyboard 1 PS2 Mouse 1 Parallel Serial port N/A 1 rear side 1 on-board (9-pin connector) USB 2.0 ports Front USB N/A Rear USB 2 13

Internal USB One Type A USB connector Three 2x5 pin Intel FPIO USB pin headers (total 5 ports) Input Requirements (per power supply) Range line voltage Rated input current Rated input frequency Rated input power 100~240 VAC 9 A~4A 50 to 60 Hz 720W Power supply Supplier to propose power budget for PSU spec setting 720W (100V-240V) gold level 90% high-efficiency power supply. Hot plug power supply module (Gold level) BTU (Maximum) Server Power cord 3276 BTU/hr 6 highline (IEC-IEC) power cord System Cooling Support 10 to 35 C (50 to 95 F) environment Two CPU heat-sink (2U height) supporting Intel Xeon processors up to TDP 95W Support memory full-populated configuration Support up to 12*SAS/SATA HDDs 3+1 hot plug, redundant system fans with PWM controlled MB Thermal Feature System fans support PWM fan speed control with SMART FAN feature Common used for Gateway 2U server platforms Compliance Windows Hardware Logo Program Requirements ACPI 3.0b PCI-E 2.0 for Gen2 PXE 2.1 WOL SMBIOS 2.6.1 IPMI 2.0 System inlet temperature Operating 10 to 35 C (50 to 95 F) at sea level with an altitude derating of 1.0 C per every 305 m (1.8 F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft) 14

Relative humidity (non-condensing) Non-operating Operating Non-operating -40 to 70 C (-40 to 158 F). 8 to 90% relative humidity (Rh), 28 C (82.4 F) maximum wet bulb temperature, non-condensing 5 to 95% relative humidity (Rh), 38.7 C (101.7 F) maximum wet bulb temperature, non-condensing Acoustic noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23 C ambient environment. Noise emissions were measured in accordance with ISO 7779 Idle LWAd LpAm 5.1BA 40dBA Operating LWAd LpAm 5.7BA 44dBA EMI Considerations Emissions Classification (EMC) Adequate EMC shielding to meet Class A of EMC requirements (FCC, CE, BSMI) Chassis seams have features to enhance grounding Motherboard mounting features provides grounding Normative standards : CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 FCC rating Class A Normative standards EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements Regulatory Compliant Standard EMC 5 CE (Class A) Safety 6 CB and GS 5 Compliance availability varies by region and country. 15

Power Supply Specification 720W Power Supply Operational Input Voltage Range (Vrms) Frequency Range (Nominal) (Hz) Nominal Input Voltage (Vrms) Max. Rated Output Wattage Nominal Input Current (A rms) Max. Rated Input Wattage Rating (Watts) Max. Rated VA (Volt-Amp) Efficiency (%) at Max. Rated Output Wattage 100 to 240 60/50 100 120 208 200 220 230 240 720 720 720 720 720 720 720 8.46 6.97 3.80 3.87 3.74 3.5 3.29 846.0 836.4 790.4 774.0 822.8 805.0 789.6 837.54 828.03 774.59 758.52 806.34 788.9 773.81 88.12 89.49 90.95 90.74 91.51 91.92 92.27 Power Factor 0.99 0.99 0.98 0.98 0.98 0.98 0.98 Leakage Current (ma) Max. Inrush Current (A peak) Max. Inrush Current Duration (ms) Max. British Thermal Unit Rating (BTU/hr) 0.17 0.19 0.29 0.31 0.35 0.37 0.41 17.24 19.41 18.52 16.88 16.48 20.47 22.54 4.62 4.58 4.61 4.62 4.64 4.63 4.64 2456.64 2456.64 2456.64 2456.64 2456.64 2456.64 2456.64 16

RAID Volume and Setup Layout Default 2 HDDs RAID Volume and system partition Default 8 HDDs RAID Volume and system partition Default 12 HDDs RAID Volume and system partition 17

Memory Specifications Each processor has three memory channels (1, 2 and 3) and each channel has two slots - A (Px1A, 2A, 3A in blue) and B (Px1B, 2B, 3B in black). So, the system has a total of twelve memory slots. The memory slots support DDR3-1333 registered/unbuffered ECC memory modules, but it s not allowed to mix R and U in a system. For all memory modes, the slot A in each channel should be populated first. If slot A is empty, slot B can t be used. NOTE: When you are using a single-processor server, you should install the memory module into P11A to P13B slots when CPU is installed in CPU1 socket. The P21A to P23B slots are enabled when a second CPU is installed on the CPU2 socket. For the system to function, modules must be installed following the slot sequence listed below. module of the same type, size and manufacturer must be installed in the same colored slots. Independent mode: Single processor configuration (subjected to change if any update) Total Physical 1B 1A 2B 2A 3B 3A Memory 2GB 2GB 4GB 2GB 2GB 6GB 2GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 4GB 4GB 8GB 4GB 4GB 12GB 4GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 8GB* 6 8GB 16GB 8GB 8GB 24GB 8GB 8GB 8GB 32GB 8GB 8GB 8GB 8GB 6 8 GB memory availability varies by region and country. 18

Dual processor configuration (subjected to change if any update) Total P1 P2 Physical 1B 1A 2B 2A 3B 3A 1B 1A 2B 2A 3B 3A Memory 4GB 2GB 2GB 6GB 2GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 16GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 18GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 24GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 8GB 4GB 4GB 12GB 4GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 32GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 19

Mirroring or Lockstep mode: Mirroring mode & Lockstep mode need the channel 1 & channel 2 with identical s. 1A and 2A should be the same type, size and manufacturer. 1B and 2B memory should be the same type, size and manufacturer. Channel 3 is no function in this mode. Same rule is applied to the CPU2 memory channel 1, 2, 3. For mirroring mode, the memory contains a primary image and a copy of the primary image. Therefore, the effective size of memory is reduced by at least one-half. Single processor configuration Total Physical Memory 1B 1A 2B 2A 4GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 8GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 16GB 7 8GB 8GB 32GB 8GB 8GB 8GB 8GB 3B 3A Dual processor configuration Total P1 P2 Physical 1B 1A 2B 2A 3B 3A 1B 1A 2B 2A 3B 3A Memory 4GB 2GB 2GB 8GB 2GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 16GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 8GB 4GB 4GB 16GB 4GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 32GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 16GB 8 8GB 8GB 7 7 8 GB memory availability varies by region and country. 8 8 8 GB memory availability varies by region and country. 20

32GB 8GB 8GB 8GB 8GB Sparing mode In this mode, if the system detects degrading memory and did not crash, the data in the failed channel will be copied to the spare channel. The failed channel is then isolated and the spare channel becomes active. However, any uncorrectable error that happens before the isolation will still cause the system to stop normal operation. Channel 3 is the spare channel. Therefore, the effective size will be reduced by one-third. Follow the population rules described in the independent mode. Sparing mode requires that all three channels use identical s. 1A, 2A and 3A should be the same type, size and manufacturer, likewise for 1B, 2B and 3B. The same rule applies to processor 2. Single processor configuration Total Physical 1B 1A 2B 2A 3B 3A Memory 6GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 12GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 24GB* 8GB 8GB 8GB Dual processor configuration Total P1 P2 Physical 1B 1A 2B 2A 3B 3A 1B 1A 2B 2A 3B 3A Memory 6GB 2GB 2GB 2GB 12GB 2GB 2GB 2GB 2GB 2GB 2GB 18GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 24GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 2GB 12GB 4GB 4GB 4GB 24GB 4GB 4GB 4GB 4GB 4GB 4GB 36GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 4GB 21

Storage The GN1600 F1 chassis was designed to support twelve 3.5" SAS/SATA hot-swappable hard drives. As a system, ach server board supports the use of three SATA drives. A single SATA backplane works to apply system-based control for power and fan speed functions. RAID setup is limited to a three-drive scheme (RAID cannot be spread across all twelve drives). Hard Disk Drive Support Drive Quantity Bay Supported Required Controller Supported 3.5 SATA/SAS hard drive Up to 12 0 11 1* 16-port SAS RAID card NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the host bus adapter (HBA) or controller. 22

Power Specifications 720W Power Supply Operational Input Voltage Range (Vrms) Frequency Range (Nominal) (Hz) Nominal Input Voltage (Vrms) Max. Rated Output Wattage Nominal Input Current (A rms) Max. Rated Input Wattage Rating (Watts) Max. Rated VA (Volt-Amp) Efficiency (%) at Max. Rated Output Wattage 100 to 240 60/50 100 120 208 200 220 230 240 720 720 720 720 720 720 720 8.46 6.97 3.80 3.87 3.74 3.5 3.29 846.0 836.4 790.4 774.0 822.8 805.0 789.6 837.54 828.03 774.59 758.52 806.34 788.9 773.81 88.12 89.49 90.95 90.74 91.51 91.92 92.27 Power Factor 0.99 0.99 0.98 0.98 0.98 0.98 0.98 Leakage Current (ma) 0.17 0.19 0.29 0.31 0.35 0.37 0.41 Max. Inrush Current (A peak) Max. Inrush Current Duration (ms) Max. British Thermal Unit Rating (BTU/hr) 17.24 19.41 18.52 16.88 16.48 20.47 22.54 4.62 4.58 4.61 4.62 4.64 4.63 4.64 2456.64 2456.64 2456.64 2456.64 2456.64 2456.64 2456.64 23

Options 9 Memory 2GB 3.5 HDD SAS 600 GB Samsung 2GB, R, M393B5673EH1-CH9, DDR3-1333 600GB, Seagate 3.5" SAS, 15K RPM, Cheetah 15K.7, 6Gb/s, 16MB SAS 300 GB SATA 1 TB SATA 2 TB SAS RAID/FC HBA SAS RAID Card 300GB, Seagate 3.5" SAS, 15K RPM, Cheetah 15K.7, 6Gb/s, 16MB 1TB, Nearline 7200RPM, 3Gb/s, 32MB 2TB, Nearline 7200RPM, 3Gb/s, 32MB LSI SAS MegaRAID MegaRAID SAS 9260-16i, bulk, LSI Castor, 16 internal ports 2108 IC, 512MB, PCI-E 2.0 x 8, RAID 0/1/10/5/50/6/60 FC HBA FC HBA Qlogic SANblade QLE2462 Dual Port 4-Gbps Fibre Channel to PCI Express Host Bus Adapter, 2ch, 4Gb FC HBA, PCI-E x4, Dual LC ports Qlogic SANblade QLE2460 Single Port 4-Gbps Fibre Channel to PCI Express Host Bus Adapter, 1ch, 4Gb FC HBA, PCI-E x4, Single LC port (w/ both std & low profile bracket) 9 Options are subject to change without notice. Please contact authorized Gateway representative for latest available options. 24

Revision History Date version Note/changes 2009/07/28 1-0-0 First release 2010/12/31 2-0-0 1) Minor wording and format updates 2) Now supported Windows Storage Sever 2008 R2 3) Added Windows Storage Server 2008 R2 features in specification 4) Maximum storage increased to Up to 24 TB raw internal SATA Up to 7.2 TB raw internal SAS 5) Added LSI SAS MegaRAID SAS PCIe 2.0 x16 9260-16i with 8-internal ports, 512 MB, supporting RAID 0/1/10/5/50/6/60 (default bundle in system configuration) 6) Removed 1 GB memory support 2011/01/06 2-0-1 Added 3 more skus (600 GB, 2TB, and 4 TB) In a continuing effort to improve the quality of our products, information in this document is subject to change without notice. Images shown are only representations of some of the configurations available for this model. Availability may vary depending on region. Microsoft and Windows are registered trademarks of Microsoft Corporation. Intel, the Intel logo, Pentium, Xeon and Xeon Inside are trademarks of Intel Corporation. 2010. All rights reserved. 25