Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Similar documents
Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Shared LOM support on Modular

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Dell 1741M Converged Network Adapter FCoE Boot from SAN Guide

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

Configuring Direct-Connect between a DR Series System and Backup Media Server

Using Dell Repository Manager with Dell OpenManage Essentials

Lifecycle Controller with Dell Repository Manager

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Teradici APEX 2800 for VMware Horizon View

Setting Up Replication between Dell DR Series Deduplication Appliances with NetVault 9.2 as Backup Software

Deploying Solaris 11 with EqualLogic Arrays

Dell Wyse Datacenter for VMware Horizon View Cloud Pod Architecture

Dell Appliance for Wyse

Access Control Policies

FluidFS Antivirus Integration

Wired + Wireless Cloud-managed Campus Reference Architecture

Web Service Eventing Support for Hardware Inventory and Monitoring

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Support Matrix

SUU Supporting the DUP Dependency

Using Lifecycle Controller to Configure UEFI Secure Boot and OS Deployment

Running Milestone XProtect with the Dell FS8600 Scale-out File System

Efficient Video Distribution Networks with Multicast: IGMP Querier and PIM-DM

Optimizing I/O Identity and Applying Persistence Policy on Network and Fibre Channel Adapters

VRF lite for Dell Networking N-Series

Remote Power Management of Dell PowerEdge M1000e with Chassis Management Controller (CMC) Using Windows Remote Management (WinRM)

LSI SAS i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information

Dell PowerEdge R920 System Powers High Performing SQL Server Databases and Consolidates Databases

Configuring a Dell EqualLogic SAN Infrastructure with Virtual Link Trunking (VLT)

Dell PowerEdge VRTX Networking Deployment Guide for Microsoft Lync and Dell Mobility

Wired + Wireless Cloud-managed Campus Deployment Guide Branch, Small Campus and Distributed Sites

Dell Reseller Option Kit Important Information

Release Notes. Dell Server Management Pack Suite For CPS. Version 5.1.1

Best Practices for Configuring an FCoE Infrastructure with Dell Compellent and Cisco Nexus

Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

Dell PowerVault Network Attached Storage (NAS) Systems Running Windows Storage Server 2012 Troubleshooting Guide

Deploying Dell PowerConnect 8100 and Cisco Catalyst Switches

Stacking Dell PowerConnect 10G Switches: M8024-k, 8024, 8024F

Deploying Dell Networking MXL and PowerEdge M IO Aggregator with the FC FlexIO Module in a Cisco MDS Environment

Advanced Performance Tuning for Dell EqualLogic Auto-Replication

High-Performance Graphics with VMware Horizon View 5.2

Performance Baseline for Deploying Microsoft SQL Server 2012 OLTP Database Applications Using EqualLogic PS Series Hybrid Storage Arrays

Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager Installation Guide

Active System Manager Release 8.2 Installation Guide

Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager Installation Guide

Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches, and Dell Compellent Storage Array

Dell Networking FC Flex IOM: Deployment of FCoE with Dell FC Flex IOM, Brocade FC switches and Dell Compellent Storage Array

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

Best Practices for Configuring Data Center Bridging with Windows Server and EqualLogic Storage Arrays

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Quick Start Guide

Dell SupportAssist Version For Dell OpenManage Essentials Quick Start Guide

Dell PowerConnect and FTOS - Flow Control and Network Performance

Dell Networking MXL and M IOA FC-FlexIO Direct Connect Storage Deployment Guide

Dell Data Protection for VMware Horizon View Infrastructures

Management Station Software Version 7.3 Installation Guide

Remote and Branch Office Reference Architecture for VMware vsphere with Dell PowerEdge VRTX

Dell PowerEdge T620 Getting Started Guide

Active System Manager Release Installation Guide

Active Fabric Manager Installation Guide 1.5

PowerEdge FX2 FN I/O Module VLT Deployment Guide

FCoE Cookbook for HP Virtual Connect

Citrix XenDesktop with Provisioning Server for VDI on Dell Compellent SC8000 All Flash Arrays for 3,000 Users

Stacking Dell Force10 MXL 10/40G Blade Switches

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center Essentials

Active System Manager Version 8.0 Quick Installation Guide

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

Dell Server Deployment Pack Version 2.0 for Microsoft System Center Configuration Manager User's Guide

Active Fabric Manager. Release Notes 1.5. June 2013

OpenManage Integration for VMware vcenter Using the vsphere Client Quick Install Guide Version 2.0

Dell PowerEdge R720 and R720xd Getting Started Guide

Overview of Microsoft Private Cloud with Dell EqualLogic Storage Arrays

Dell PowerVault MD Storage Array Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And Microsoft System Center

Dell PowerEdge T420 Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Dell Fabric Manager Deployment Guide 1.0.0

Dell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials Installation Guide

Virtual Machine Protection with Dell EqualLogic Virtual Storage Manager v4.0

Lifecycle Controller 2 Release 1.0 Version Readme

ClearPass NAC and Posture Assessment for Campus Networks

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Dell Server Management Pack Suite Version For Microsoft System Center Operations Manager And System Center Essentials User s Guide

Dell EqualLogic Storage Management Pack Suite Version 5.0 For Microsoft System Center Operations Manager And System Center Essentials User s Guide

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

FS8600 Snapshot and Volume Cloning Best Practices

Microsoft SharePoint Server 2010 on Dell Systems

Dell Networking S5000: Deployment of a Converged Infrastructure with FCoE. Deployment/Configuration Guide

Active System Manager Release 8.2 Compatibility Matrix

Accelerate SQL Server 2014 In-Memory OLTP Performance with Dell PowerEdge R920 and Express Flash NVMe PCIe SSDs

Dell Repository Manager Version 1.8 Troubleshooting Guide

Virtual Desktop Infrastructure with Dell Fluid Cache for SAN

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

Dell Lifecycle Controller Integration For Microsoft System Center Configuration Manager Version Installation Guide

Dell Force10 Z9000 System. Quick Start Guide. Regulatory Model: Z9000

UCS Engineering Details for the SAN Administrator

Sizing and Best Practices for Deploying Microsoft Exchange Server 2013 with Dell Compellent Storage Arrays

Managing and Protecting a Windows Server Hyper-V Environment using Dell EqualLogic PS Series Storage and Tools

VMware Infrastructure 3.5 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

Dell EMC Networking S4148-ON and S4128-ON

Transcription:

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets CLI Config Sheets Dell Networking Engineering November 2013 A Dell Deployment and Configuration Guide

Revisions (required) Date Description Authors / Editors Nov 2013 Initial release Kevin Locklear, Ed Blazek 2013 Dell Inc., All rights reserved. Except as stated below, no part of this document may be reproduced, distributed or transmitted in any form or by any means, without express permission of Dell. You may distribute this document within your company or organization only, without alteration of its contents. THIS DOCUMENT IS PROVIDED AS-IS, AND WITHOUT ANY WARRANTY, EXPRESS OR IMPLIED. IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY DISCLAIMED. PRODUCT WARRANTIES APPLICABLE TO THE DELL PRODUCTS DESCRIBED IN THIS DOCUMENT MAY BE FOUND AT: http://www.dell.com/learn/us/en/19/terms-of-sale-commercial-and-public-sector Performance of network reference architectures discussed in this document may vary with differing deployment conditions, network loads, and the like. Third party products may be included in reference architectures for the convenience of the reader. Inclusion of such third party products does not necessarily constitute Dell s recommendation of those products. Please consult your Dell representative for additional information. Trademarks used in this text: Dell, the Dell logo, Dell Boomi, Dell Precision,OptiPlex, Latitude, PowerEdge, PowerVault, PowerConnect, OpenManage, EqualLogic, Compellent, KACE, FlexAddress, Force10 and Vostro are trademarks of Dell Inc. Other Dell trademarks may be used in this document. Cisco Nexus, Cisco MDS, Cisco NX- 0S, and other Cisco Catalyst are registered trademarks of Cisco System Inc. EMC VNX, and EMC Unisphere are registered trademarks of EMC Corporation. Intel, Pentium, Xeon, Core and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron, AMD Phenom and AMD Sempron are trademarks of Advanced Micro Devices, Inc. Microsoft, Windows, Windows Server, Internet Explorer, MS-DOS, Windows Vista and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell and SUSE are registered trademarks of Novell Inc. in the United States and other countries. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Citrix, Xen, XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware, Virtual SMP, vmotion, vcenter and vsphere are registered trademarks or trademarks of VMware, Inc. in the United States or other countries. IBM is a registered trademark of International Business Machines Corporation. Broadcom and NetXtreme are registered trademarks of Broadcom Corporation. Qlogic is a registered trademark of QLogic Corporation. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and/or names or their products and are the property of their respective owners. Dell disclaims proprietary interest in the marks and names of others. 2 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets revision 1.0

Table of contents Revisions (required)... 2 1 Dell Networking MXL and PowerEdge M I/O Aggregator Module switches in Cisco Nexus 5000 series FCoE environment... 5 1.1 Cisco Nexus 5000 series configuration fabric mode... 6 1.2 Dell Networking MXL CLI configuration for FIP Snooping... 9 3 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets revision 1.0

Internal 10/1 Gb Fixed QSFP Ports I/O BayOne I/O Bay Two Dell Networking MXL and Dell PowerEdge M I/O Aggregator Port Mapping QSFP+ 2x40Gb QSFP+ 8x10GB SFP+ (breakout) SFP+ 4x10Gb 10G-BaseT 4x10Gb FC8 x 4 56 55 54 53 53 52 52 52 52 51 51 51 51 50 50 50 50 49 49 49 49 49 QSFP+ 2 X 40Gb QSFP+ 8 X 10GB SFP+ (breakout) SFP+ 4 X10Gb 10G-BaseT 4 X 10Gb FC8 x 4 48 47 46 45 45 44 44 44 44 43 43 43 43 42 42 42 42 41 41 41 41 41 QSFP+ 2 X 40Gb QSFP+ 8 X 10GB SFP+ (breakout) SFP+ 4 X10Gb 10G-BaseT 4 X 10Gb FC8 x 4 40 39 38 37 37 36... 35... 34... 33 33... Internal 10 / 1 GB interfaces 32 32 32 32 32 31 31 31 31 31............... 2 2 2 2 2 1 1 1 1 1 Figure 1 Port mapping for MXL and IOA 4 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config

1 Dell Networking MXL and PowerEdge M I/O Aggregator Module switches in Cisco Nexus 5000 series FCoE environment Figure 2 Dell MXL and IOA with Cisco Nexus 5000 series fabric mode topology 5 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config

1.1 Cisco Nexus 5000 series configuration fabric mode Enable features, configure all pre-planned VSAN s, VLAN s, and VFC s (see planning matrix) - Side 1 (SAN A) 1. Enable feature fcoe to allow the FC ports to function. 2. Feature npiv allows multiple device logins through the same physical port 3. Feature lacp enables the LACP protocol for portchannels (LAGs) feature fcoe feature npiv feature lacp Enable features, configure all pre-planned VSAN s, VLAN s, and VFC s (see planning matrix) - Side 2 (SAN B) 1. Enable feature fcoe to allow the FC ports to function. 2. Feature npiv allows multiple device logins through the same physical port 3. Feature lacp enables the LACP protocol for portchannels (LAGs) feature fcoe feature npiv feature lacp 1 st (SAN A) Cisco Nexus 5548 Configuration 4. Create a new VSAN - instantiate it in the VSAN database. 5. Configure regular ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN 6. Instantiate but do not configure the upstream portchannel (LAG) to the core /aggregation switch 7. Instantiate but do not configure the downstream port-channel (LAG) to the IOA vsan database vsan 2 vlan 20,30-32, 88 vlan 1000 fcoe vsan 2 interface port-channel 1 interface port-channel 20 8. Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the IDRAC page for the server. (in this example 2 different server s CNA s are configured) interface vfc101 bind mac-address 5C:F9:DD:16:EF:07 interface vfc102 bind mac-address 5C:F9:DD:16:EF:21 2 nd (SAN B) Cisco Nexus 5548 Configuration 4. Create a new VSAN - instantiate it in the VSAN database. 5. Configure regular ethernet VLANs, and then the FCoE VLAN is created with an assignment to its respective VSAN 6. Instantiate but do not configure the upstream port-channel (LAG) to the core /aggregation switch 7. Instantiate but do not configure the downstream port-channel (LAG) to the IOA vsan database vsan 3 vlan 21,30-32,88 vlan 1001 fcoe vsan 3 interface port-channel 2 interface port-channel 21 8. Create the VFC interface to bind to the servers CNA FIP MAC address. This can be located in the CMC WWN table or the IDRAC page for the server. (in this example 2 different server s CNA s are configured) interface vfc201 bind mac-address 5C:F9:DD:16:F0:10 interface vfc202 bind mac-address 5C:F9:DD:16:F1:7E 9. Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC port(s) that will be used. vsan database vsan 2 interface vfc101 vsan 2 interface vfc102 vsan 2 interface fc2/1 vsan 2 interface fc2/2 9. Move back into the VSAN database and create entries for the new VFC just created and create entries for the FC port(s) that will be used. vsan database vsan 3 interface vfc201 vsan 3 interface vfc202 vsan 3 interface fc2/1 vsan 3 interface fc2/2 6 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config

Side 1 (SAN A) 10. Configure the needed port-channels/lags/trunks. There will be one going upstream to the core/ aggregation switch, and one going downstream to the IOA/MXL. interface ethernet 1/1-2 channel-group 20 mode active description FCoE_downlink_to_IOA-MXL interface ethernet 1/9-10 channel-group 1 mode active description Ethernet_uplink_to_7K Side 2 (SAN B) 10. Configure the needed port-channels (LAGs)/Trunks. There will be one going upstream to the core/ aggregation switch, and one going downstream to the IOA/MXL. interface ethernet 1/1-2 channel-group 21 mode active description FCoE_downlink_to_IOA-MXL interface ethernet 1/9-10 channel-group 2 mode active description Ethernet_uplink_to_7K 1 st (SAN A) Cisco Nexus 5548 Configuration 11. Configure the port-channels with the applicable settings which will then automatically apply to the individual ethernet interfaces if done in this order. VLAN 30-32, and 88 are example ethernet VLAN s just to show how these are applied in this configuration. VLAN 20 is the native VLAN applicable to the port-channel that is being used for FCoE, however the default VLAN of the switch can be used in this case and this is not required to be configured. VLAN 1000 is the FCoE VLAN and this must be configured for FCoE traffic to traverse from the FSB to the Nexus 5k and then to storage. interface port-channel 1 description port-channel_eth9+10_to_7k switchport mode trunk switchport trunk allowed vlan 30-32,88 interface port-channel 20 description portchannel_eth1+2_to_ioa-mxl switchport mode trunk switchport trunk native vlan 20 switchport trunk allowed vlan 20,1000 2 nd (SAN B) Cisco Nexus 5548 Configuration 11. Configure the port-channels with the applicable settings which will then automatically apply to the individual ethernet interfaces if done in this order. VLAN 30-32, and 88 are example ethernet VLAN s just to show how these are applied in this configuration. VLAN 21 is the native VLAN applicable to the port-channel that is being used for FCoE, however the default VLAN of the switch can be used in this case and this is not required to be configured. VLAN 1001 is the FCoE VLAN and this must be configured for FCoE traffic to traverse from the FSB to the Nexus 5k and then to storage. interface port-channel 2 description port-channel_eth9+10_to_7k switchport mode trunk switchport trunk allowed vlan 30-32,88 interface port-channel 21 description portchannel_eth1+2_to_ioa-mxl switchport mode trunk switchport trunk native vlan 21 switchport trunk allowed vlan 21,1001 12. Turn on or enable the FC ports that are applicable to this configuration. interface fc2/1-2 12. Turn on or enable the FC ports that are applicable to this configuration. interface fc2/1-2 7 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config

Configure Zoning with Cisco Nexus in switch mode (NPIV)- Side 1 (SAN A) 13. Configure applicable zones that will match the blade server CNA s (2 are used in this example) to applicable FC port(s) going to storage. zone1san_a is the example name being used here but this name is at the discretion of the administrator pwwn <hh...hh> is applicable to the PWWN of the CNA zone name zone1san_a vsan 2 member pwwn <20:01:5c:f9:dd:16:ef:07> member pwwn <20:01:5c:f9:dd:16:ef:21> member interface fc2/1 member interface fc2/2 1 st (SAN A) Cisco Nexus 5548 Configuration 14. Create a zoneset that will group all the applicable zones together and allow for the group activation. set1san_a is just an example name for this configuration 15. Activate the zoneset zoneset name set1san_a vsan 2 member zone1san_a zoneset activate name set1san_a vsan 2 Check that the applicable zoneset and zones are now active Show zoneset active results Zoneset name set1san_a vsan 2 zone name zone1san_a vsan 2 * fcid 0x850000 [interface pwwn 20:01:5c:f9:dd:16:ef:07] * fcid 0x850100 [interface pwwn 20:01:5c:f9:dd:16:ef:21] * fcid 0x850200 [interface fc2/1 swwn 20:41:54:7f:ee:53:3e:80] * fcid 0x850300 [interface fc2/1 swwn 20:42:54:7f:ee:53:3e:80] Configure Zoning with Cisco Nexus in switch mode (NPIV)- Side 2 (SAN B) 13. Configure applicable zones that will match the blade server CNA s (2 are used in this example) to applicable FC port(s) going to storage. zone1san_b is the example name being used here but this name is at the discretion of the administrator 2 nd (SAN B) Cisco Nexus 5548 Configuration pwwn <hh...hh> is applicable to the PWWN of the CNA zone name zone1san_b vsan 3 member pwwn <20:01:5c:f9:dd:16:f0:10> member pwwn <20:01:5c:f9:dd:16:f1:7e> member interface fc2/1 member interface fc2/2 14. Create a zoneset that will group all the applicable zones together and allow for the group activation. set1san_b is just an example name for this configuration 15. Activate the zoneset zoneset name set1san_b vsan 3 member zone1san_b zoneset activate name set1san_b vsan 3 Check that the applicable zoneset and zones are now active Show zoneset active results Zoneset name set1san_b vsan 3 zone name zone1san_a vsan 3 * fcid 0x850000 [interface pwwn 20:01:5c:f9:dd:16:f0:10] * fcid 0x850100 [interface pwwn 20:01:5c:f9:dd:16:f1:7e] * fcid 0x850200 [interface fc2/1 swwn 20:41:54:7f:ee:56:55:40] * fcid 0x850300 [interface fc2/1 swwn 20:42:54:7f:ee:56:55:40] 8 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config

1.2 Dell Networking MXL CLI configuration for FIP Snooping Enable features, configure all pre-planned VLAN s, and other commands - Side 1 (SAN A) Enable FIP-snooping feature Enable LLDP protocol Configure service-class dynamic dot1p feature fip-snooping exit service-class dynamic dot1p Enable features, configure all pre-planned VLAN s, and other commands - Side 2 (SAN B) Enable FIP-snooping feature Enable LLDP protocol Configure service-class dynamic dot1p feature fip-snooping exit service-class dynamic dot1p 1 st (SAN A) Dell Networking MXL (FIP-Snooping) Configuration Configure default VLAN for switch if needed, this is the global untagged VLAN for the switch default vlan-id 20 default vlan-id 21 Configure the downstream or server facing switch ports. interface range te 0/1-2 portmode hybrid switchport dcbx port-role auto-downstream spanning-tree pvst edge-port Configure the upstream or FCF switch facing individual external ports to be part of a portchannel interface range te 0/51-52 port-channel-protocol LACP port-channel 1 mode active no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream 2 nd (SAN B) Dell Networking MXL (FIP-Snooping) Configuration Configure default VLAN for switch if needed, this is the global untagged VLAN for the switch Configure the downstream or server facing switch ports. interface range te 0/1-2 portmode hybrid switchport dcbx port-role auto-downstream spanning-tree pvst edge-port Configure the upstream or FCF switch facing individual external ports to be part of a portchannel interface range te 0/51-52 port-channel-protocol LACP port-channel 1 mode active no advertise dcbx-tlv ets-reco dcbx port-role auto-upstream Configure the upstream port-channel interface port-channel 1 portmode hybrid switchport fip-snooping port-mode fcf Configure the upstream port-channel interface port-channel 1 portmode hybrid switchport fip-snooping port-mode fcf 9 Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config