Electronic timer CT-AHD.22

Similar documents
Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-ERS.21

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Three-phase monitoring relay

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Messaging module CP-C MM

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Redundancy unit CP-A RU

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Power supply CP-C 24/5.0

Power supply CP-E 24/10.0 Primary switch mode power supply

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Contact protection relay

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Power supply CP-C 24/5.0

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.11

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.31

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Accessories for pluggable interface relays CR-M Sockets

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Pluggable interface relays CR-P Pcb relays

em4 Accessories Digital expansions

TU531, TU532 Terminal Unit

Output Voltage* (nom.)(adjustable)

DI572 Digital Input Module

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

AI531 Analog Input Module

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

DC561, digital input/output module,

Output Voltage* (nom.)(adjustable)

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

AO523 Analog Input Module

AO561 Analog Output Module

AI561 Analog Input Module

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TF501, TF521 Terminal Bases

MINI-PS AC/10-15DC/8

02/11/2015

DI561 Digital Input Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DC562, digital input/output module,

DC541 Digital Input/Output Module

DC522 Digital Input/Output Module

DX561 Digital Input/Output Module

Power Supply HARTING pcon

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

AX522 Analog Input/Output Module

TRIO-DIODE/12-24DC/2X10/1X20

CM597 Ethernet Communication Module

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

Electronic timers CT range

AX521 Analog Input/Output Module

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Transcription:

2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W timing d R: yellow LED V output relays energized e Circuit diagram f Function diagram Features Rated control supply voltage 24 48 V DC, 24 240 V AC Single function timer OFF delay 7 time ranges (0.05 s 100 h) in one device 2 c/o contacts (250 V / 5 A) Control input: voltage related triggering, polarized, capable of switching a parallel load 2 LEDs for status indication Width of only 17.5 mm Light grey enclosure in RAL 7035 Approvals A UL 508, CAN/CSA C22.2 No.14 D GOST K CB scheme pending E CCC pending Marks a CE b C Tick pending Order data Type CT-AHD.22 Rated control supply voltage 24 48 V DC, 24 240 V AC Time range Output Control input 0.05 s 100 h 2 c/o contacts voltagerelated triggering Order code Application With their structural form and their width of 17.5 mm only, the CT D range timers are ideally suited for installation in distribution cabinets. Operating mode The CT AHD.22 with 2 c/o contacts and offers 7 time ranges, from 0.05 s to 100 h. The time delay range is rotary switch selectable on the front of the unit. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit.

Function diagram(s) B OFF delay with auxiliary voltage This function requires continuous control supply voltage for timing. If control input A1 Y1/B1 is closed, the output relay energizes immediately. If control input A1 Y1/B1 is opened, the time delay starts. The green LED flashes during timing. When the selected time delay is complete, the output relay de energizes and the flashing green LED turns steady. If control input A1 Y1/B1 recloses before the time delay is complete, the time delay is reset and the output relay does not change state. Timing starts again when control input A1 Y1/B1 re opens. If control supply voltage is interrupted, the output relay de energizes and the time delay is reset. A1-A2 A1-Y1/B1 15-18, 25-28 15-16, 25-26 green LED t < t 2CDC 252 107 F0206 t = adjusted time delay Connection diagram(s) A1 Y1/ B1 A1 15 25 15 25 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 2CDC 252 116 F0b06 15 16/18 1. c/o contact 25 26/28 2. c/o contact A1 A2 Rated control supply voltage U S 24 48 V DC or 24 240 V AC A1 Y1/B1 Control input Wiring instructions Parallel load to control input possible / allowed L(+) A1 Y1/B1 2CDC 252 102 F0b06 A2 N(-) 2

Technical data Data at T a = 25 C and rated values, if nothing else indicated Input circuits - Supply circuit Rated control supply voltage U S A1 A2 24 240 V AC A1 A2 24 48 V DC Rated control supply voltage tolerance 24 240 V AC 15...+10 % 24 48 V DC 15...+10 % Typical current / power consumption 24 V DC 230 V AC 115 V AC 24 48 V DC 24.12 ma / / / 24 240 V AC / 31.30 ma / 19.89 ma / Rated frequency Frequency range AC Power failure buffering time DC; 50/60 Hz 47 63 Hz min. 30 ms Input circuits - Control circuit Control input, control function A1 Y1/B1 start timing external Kind of triggering voltage related triggering Resistance to reverse polarity Polarized Capable of switching a parallel load Maximum cable length to the control inputs Minimum control pulse length Control voltage potential yes yes yes 50 m 100 pf/m 30 ms see rated control supply voltage U S Current consumption of the control input 24 V DC 0.92 ma 230 V AC 6.49 ma 115 V AC 3.27 ma Timing circuit Kind of timer Single function timer OFF delay with auxiliary voltage Time ranges 0.05 s 100 h Recovery time Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states 0.05 1 s, 0.5 10 s, 5 100 s, 0.5 10 min, 5 100 min, 0.5 10 h, 5 100 h < 50 ms Δt < 0.005 %/V Δt < 0.06 %/ C Control supply voltage / timing U: green LED V: control supply voltage applied Control supply voltage / timing U: green LED W: timing Relay status R: yellow LED V: output relay energized Output circuits Kind of output 15 16/18 Relay, 1. c/o contact 25 26/28 Relay, 2. c/o contact Contact material Rated operational voltage U e Derating Cd free 250 V 3

Output circuits Minimum switching voltage / Minimum switching current 12 V / 100 ma Maximum switching voltage / Minimum switching current see load limit curve / see load limit curve Rated operational current I e (IEC 60947 5 1) AC12 (resistive) at 230 V 5 A AC15 (inductive) at 230 V 3 A Mechanical lifetime Electrical lifetime Short circuit resistance, maximum fuse rating (IEC/EN 60947 5 1) DC12 (resistive) at 24 V DC13 (inductive) at 24 V n/c contact n/o contact 5 A 2 A 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles (AC12, 230 V, 4 A) 6 A fast acting 10 A fast acting General data Duty time 100 % Repeat accuracy (constant parameters) Δt <± 0.5 % Dimensions (W x H x D) Weight Mounting position Minimum distance to other units 17.5 x 80 x 58 mm (0.69 x 3.15 x 2.28 inches) approx. 65 g (approx. 0.14 lb) normal operation mode horizontal none vertical Mounting DIN rail (EN 60715), snap on mounting without any tool Degree of protection enclosure / terminals IP50 / IP20 any none Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule Screw connection 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) rigid 2 x 0.5 1.5 mm 2 / 1 x 0.5 4 mm 2 (2 x 20 16 AWG) / (1 x 20 12 AWG) 7 mm (0.28 inches) 0.5 0.8 Nm Environmental data Ambient temperature range operation 20...+60 C storage 40...+85 C Damp heat, cyclic (IEC/EN 60068 2 30) Vibration, sinusoidal (IEC/EN 60068 2 6) Shock, half sine (IEC/EN 60068 2 27) 6 x 24 h cycles, 55 C, 95 % RH 4 m/s 2, 20 cycles, 10...150...10 Hz 100 m/s 2, 11 ms Isolation data Rated isolation voltage U i Output circuit 1 / Output circuit 2 300 V Input circuit / Output circuit 300 V 4

Isolation data Rated impulse withstand voltage U imp (type test) (IEC/EN 60664 1, VDE 0110) Power frequency withstand voltage test (Test voltage, routine test) between all isolated circuits 4 kv; 1.2/50 µs between all isolated circuits 2.5 kv, 50 Hz, 1 s Basic insulation (IEC/EN 61140) Input circuit / Output circuit 300 V Protective separation (IEC/EN 61140, VDE 0106 part 101 and part 101/A1) Pollution degree (IEC/EN 60664 1, VDE 0110, UL 508) Overvoltage category (IEC/EN 60664 1, VDE 0110, UL 508) Input circuit / Output circuit 250 V 3 III Standards / Directives Product standard EMC Directive Low Voltage Directive RoHS Directive IEC 61812 1, EN 61812 1 + A11, DIN VDE 0435 part 2021 2004/108/EC 2006/95/EC 2002/95/EC Electromagnetic compatibility Interference immunity IEC/EN 61000 6 1 IEC/EN 61000 6 2 electrostatic discharge (ESD) IEC/EN 61000 4 2 Level 3 (6 kv / 8 kv) electromagnetic field (HF radiation resistance) IEC/EN 61000 4 3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000 4 4 Level 3 (2 kv / 5 khz) powerful impulses (Surge) IEC/EN 61000 4 5 Level 4 (2 kv L L) HF line emission IEC/EN 61000 4 6 Level 3 (10 V) Interference emission IEC/EN 61000 6 3 IEC/EN 61000 6 4 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 5

Technical diagrams Load limit curve AC voltage [V] resistive load 2CDC 252 122 F0206 DC voltage [V] resistive load 2CDC 252 121 F0206 AC current [A] DC current [A] AC load (resistive) DC load (resistive) Derating factor F Derating factor F 1.0 0.9 0.8 0.7 2CDC 252 124 F0206 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ for inductive AC load Contact lifetime Switching cycles 250 V resistive load 2CDC 252 123 F0206 Switching current [A] 6

Dimensions in mm 0.69 17,5 0.2 5 58 2.28 43,4 1.71 80 3.15 45 1.77 2CDC 252 130 F0b06 CT-AHD.22 Synonyms Used expression Alternative expression(s) Used expression Alternative expression(s) 2 c/o contacts 1 DPDT / 2 SPDT voltage related wet / non floating Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x You can find the documentation in the internet under www.abb.com/lowvoltage R Control Products R... 7

STOTZ KONTAKT GmbH As part of the on going product improvement, reserves the right to modify the characteristics of the products described in this document. The information given is non contractual. For further details please contact (www.abb.com/contacts) the company marketing these products in your country. Document number: 2CDC 111 054 D0201 (12/2007) Eppelheimer Strasse 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products