K-Space Trajectories and Spiral Scan

Similar documents
Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Development of fast imaging techniques in MRI From the principle to the recent development

Role of Parallel Imaging in High Field Functional MRI

Sources of Distortion in Functional MRI Data

Evaluations of k-space Trajectories for Fast MR Imaging for project of the course EE591, Fall 2004

Steen Moeller Center for Magnetic Resonance research University of Minnesota

MRI Physics II: Gradients, Imaging

Advanced Imaging Trajectories

FOV. ] are the gradient waveforms. The reconstruction of this signal proceeds by an inverse Fourier Transform as:. [2] ( ) ( )

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Compressed Sensing for Rapid MR Imaging

IMAGE reconstruction in conventional magnetic resonance

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

Sampling, Ordering, Interleaving

Image reconstruction using compressed sensing for individual and collective coil methods.

Sampling, Ordering, Interleaving

Constrained Reconstruction of Sparse Cardiac MR DTI Data

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

NeuroImage. Spiral imaging in fmri. Gary H. Glover. Review. Contents lists available at SciVerse ScienceDirect

Spiral keyhole imaging for MR fingerprinting

2D spatially selective excitation pulse design and the artifact evaluation

G Practical Magnetic Resonance Imaging II Sackler Institute of Biomedical Sciences New York University School of Medicine. Compressed Sensing

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Functional MRI in Clinical Research and Practice Preprocessing

Spatially selective RF excitation using k-space analysis

EE290T: Advanced Reconstruction Methods for Magnetic Resonance Imaging. Martin Uecker

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Spiral Imaging: A Critical Appraisal

SPM8 for Basic and Clinical Investigators. Preprocessing

Motion Artifacts and Suppression in MRI At a Glance

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

High-Resolution Time-Resolved Contrast-Enhanced MR Abdominal and Pulmonary Angiography Using a Spiral- TRICKS Sequence

Partial k-space Recconstruction

Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Basic fmri Design and Analysis. Preprocessing

design as a constrained maximization problem. In principle, CODE seeks to maximize the b-value, defined as, where

Partial k-space Reconstruction

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

Fast, Iterative Image Reconstruction for MRI in the Presence of Field Inhomogeneities

Efficient Sample Density Estimation by Combining Gridding and an Optimized Kernel

Parallel Magnetic Resonance Imaging (pmri): How Does it Work, and What is it Good For?

Sparse Spectral Deconvolution Algorithm for Noncartesian MR Spectroscopic Imaging

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

High Fidelity Brain Connectivity Imaging

ADVANCED RECONSTRUCTION TECHNIQUES IN MRI - 2

Computational Aspects of MRI

Spread Spectrum Using Chirp Modulated RF Pulses for Incoherent Sampling Compressive Sensing MRI

Fast Isotropic Volumetric Coronary MR Angiography Using Free-Breathing 3D Radial Balanced FFE Acquisition

Midterm Review

Joint estimation and correction of geometric distortions for EPI functional MRI using harmonic retrieval

Non-Cartesian Parallel Magnetic Resonance Imaging

Exam 8N080 - Introduction MRI

Tradeoffs and complexities in model-based MR image reconstruction

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

Non-Cartesian Reconstruction

Journey through k-space: an interactive educational tool.

Motion Robust Magnetic Susceptibility and Field Inhomogeneity Estimation Using Regularized Image Restoration Techniques for fmri

Referenceless Interleaved Echo-Planar Imaging

MultiSlice CAIPIRINHA Using View Angle Tilting Technique (CAIPIVAT)

An Iterative Approach for Reconstruction of Arbitrary Sparsely Sampled Magnetic Resonance Images

Nuts & Bolts of Advanced Imaging. Image Reconstruction Parallel Imaging

COBRE Scan Information

What is pmri? Overview. The Need for Speed: A Technical and Clinical Primer for Parallel MR Imaging 8/1/2011

Parallel Imaging. Marcin.

M R I Physics Course

A practical acceleration algorithm for real-time imaging

This Time. fmri Data analysis

Dynamic Autocalibrated Parallel Imaging Using Temporal GRAPPA (TGRAPPA)

Automatic Correction of Echo-Planar Imaging (EPI) Ghosting Artifacts in Real-Time Interactive Cardiac MRI Using Sensitivity Encoding

Accelerated parameter mapping with compressed sensing: an alternative to MR fingerprinting

k y 2k y,max k x 2k x,max

XI Signal-to-Noise (SNR)

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

Zigzag Sampling for Improved Parallel Imaging

PHASE-ENCODED, RAPID, MULTIPLE-ECHO (PERME) NUCLEAR MAGNETIC RESONANCE IMAGING

Faster 3D Vocal Tract Real-time MRI Using Constrained Reconstruction

Dynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories

Reconstruction Strategy for Echo Planar Spectroscopy and Its Application to Partially Undersampled Imaging

Motion Correction in fmri by Mapping Slice-to-Volume with Concurrent Field-Inhomogeneity Correction

Motion Artifact Suppression in MRI Using k-space Overlap Processing ABSTRACT

Magnetic Resonance Angiography

An Introduction to Image Reconstruction, Processing, and their Effects in FMRI

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

Imaging Notes, Part IV

The SIMRI project A versatile and interactive MRI simulator *

DYNAMIC magnetic resonance imaging (MRI), which captures

Fast Dynamic MRI for Radiotherapy

Motion artifact reduction technique for dual-contrast FSE imaging

Automatic Gradient Preemphasis Adjustment: A 15-Minute Journey to Improved Diffusion-Weighted Echo-Planar Imaging

High Spatial Resolution EPI Using an Odd Number of Interleaves

VD-AUTO-SMASH Imaging

Compressed Sensing And Joint Acquisition Techniques In Mri

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Combination of Parallel Imaging and Compressed Sensing for high acceleration factor at 7T

Flexible Retrospective Selection of Temporal Resolution in Real-Time Speech MRI Using a Golden-Ratio Spiral View Order

Transcription:

K-Space and Spiral Scan Presented by: Novena Rangwala nrangw2@uic.edu 1 Outline K-space Gridding Reconstruction Features of Spiral Sampling Pulse Sequences Mathematical Basis of Spiral Scanning Variations of Spiral-Out Sampling Hardware Considerations Comparison with Rectilinear Sampling An Application 2

Types of K-Space K 3 Sampling of K-SpaceK 4

Other Non-Cartesian : Circular (Zhou 1998) 5 Other Non-Cartesian : Rosette (Noll 1997) 6

Reconstruction of Non-Cartesian Sampled Data (Gridding( Gridding) Sampled data Convolution in k-space k Rectilinearly resample data Normal reconstruction ( c) ( s) S ( mδ k) = S( k ) g( mδk k ) Δk i i i i Choice of convolution function depends upon processing time and interpolation accuracy 7 Why use Non-Cartesian? Effectively faster scanning possible Efficient coverage of k-spacek Off-resonance spins result in blurring in spiral scans, rather than geometric distortion Usually robust to motion 8

The Spiral Trajectory Developed by Ahn CB, et al.,, 1986 Samples k-space k data in a spiral manner Effectively collects a circular window 9 Some Features Allows a flexible tradeoff between the number of shots, and amount of data per shot Can be combined with MRI techniques 2-D D readout function in X and Y Central over-sampling reduces sensitivity to motion Adjustable echo time 10

The Basic Pulse Sequence 11 Some Math Let k x = k cosθ and k y = k sinθ The spiral trajectory: k(t) = λθ(t) For alias-free sampling satisfying the Nyquist criterion radially, λ = N shot 2π L To satisfy the azimuthal Nyquist requirement, γ 0 2 2 GL = Δυ π 12

Some more Math The maximum k-space k radius is defined by k max N = 2L From the equation for the spiral trajectory, we can get, θ k max max = = λ π N N So what happens if the math isn t t right?? shot 13 Aliasing (B): TR=500ms, TE=2.5ms, FA=90 o, FOV=24cm, 10mm slice, N=200, N shot =32, Δυ=±62.5kHz, T acq =8.129ms, SR=120 T/m/s m/s,, G 0 =12.2mT/m, λ=0.21/cm (C): λ=0.38/cm, T acq =4.8ms (D): G 0 =22 mt/m, acq =4.8ms T acq 14

Off-Resonance Blur Blurring, due to off-resonance effects, increases with T acq Approaches to reduce blurring (a) Decrease FOV: Introduces aliasing (b) Increase N shot : Increases scan time (c) Increase Δx: : Decreases spatial resolution 15 Blur 16

Dealing with Image Blur Deconvolution Frequency-segmented correction Time-segmented correction Simulated phase-evolution evolution rewinding (SPHERE) Block regional off-resonance correction (BRORC) 17 Variations of Spiral-Out Sampling Variable-density spirals with (a) Undersampling of edges: Samples the center with Nyquist freq., time-efficient efficient (b) Oversampling of k-space: k Samples the edges at Nyquist freq., no aliasing Source: Santos, 2006 18

Variations (Contd.) Reversed Spiral (Spiral-In) and Spiral-In/Out trajectories Spiral-In/Out is a Spiral-In followed by a conventional Spiral-Out readout Source: Glover, 2001 19 Variations (Contd.) Twisting Radial Line (TWIRL): a combination of radial and spiral scanning (Jackson,( 1992) 20

Variations (Contd.) RARE + Spiral (Block, 1997) 21 Variations (Contd.) 3-Dimensional Spiral (Yen 2000) 22

Hardware Considerations Eddy currents are compensated for by adjusting the location of the A/D window relative to the spiral readout gradient Some gradient amplifier designs give poorer fidelity for spiral waveforms blurring, shading or rotating of images 23 Comparison with Rectilinear Sampling Over-samples the center of k-space, k so it is fairly motion insensitive Less number of shots required, therefore time-efficient efficient Can be used with other techniques in MR 24

Comparison with Rectilinear Sampling (Contd.) Image Blurring due to off-resonance effects Aliasing from objects extending outside the FOV Longer reconstruction time Generally restricted to applications with small FOVs,, where the effects of blurring are comparatively less 25 Spiral In-Out Scanning in CSI (Kim, 2003) Used spiral-out out-in trajectory over conventional spiral-out, to reduce phase accumulated due to gradient moments Motion similar to respiratory movement was induced TR=1500ms, TE=144ms, 30cm FOV with 10cm PRESS box, 32x32 matrix, 0.5s readout with 2min scan time, motion was 1cm/sec in Y-Y direction. 26

Spiral In-Out Scanning in CSI (Kim, 2003) Spiral-Out Spiral-In trajectory is more efficient than cartesian phase encoding as well as conventional spiral scan to reduce motion effects in CSI. 27 References Ahn CB, Rew CY, Kim JH, et. al,, Proc. Soc. Mag. Reson.. Med.,, 2: 935-936 936 (1985) Ahn CB, Kim JH, Cho ZH, High-Speed Spiral-Scan Scan Echo Planar NMR Imaging - I, IEEE Trans. Med. Imag.,, MI-5, 2-72 7 (1986) Bernstein MA, King KF, Zhou XJ, Handbook of MRI Pulse Sequences, Elsevier Academic Press, USA, 2004. Block W, Pauly J, Nishimura D, RARE Spiral T2-Weighted Imaging, Magn. Reson.. Med.,, 37:582-590 590 (1997) Glover GH, Lee AT, Motion Artifacts in fmri: Comparison of 2DFT with PR Methods, Magn. Reson.. Med.,, 33:624-635 635 (1995) Glover GH, Law CS, Spiral-In/Out BOLD fmri for Increased SNR and Reduced Susceptibility Effects, Magn. Reson.. Med.,, 46:515-522, 522, 2001 Jackson JI, Nishimura DG, Macovski A, Twisting Radial Lines with Application to Robust Magnetic Resonance Imaging of Irregular Flow, Magn. Reson.. Med.,, 25:128-139 139 (1992) Kim DH, Adalsteinsson E, Spielman DM, Spiral-Out Spiral-In CSI, Proc. Intl. Soc. Magn. Reson. Med.,, 11 (2003) Lauterbur PC, Image Formation by Induced Local Interactions: Examples involving g Nuclear Magnetic Resonance, Nature,, 242:190-191 191 (1973) Noll DC, Multi-shot shot Rosette for Spectrally-Selective Selective MR Imaging, IEEE Trans. Med. Imag.,, 16:372-377 377 (1997) Santos JM, Cunningham CH, et al., Single Breath-Hold Whole-Heart MRA using Variable-Density Spirals at 3T, Magn. Reson.. Med.,, 55:371-379 379 (2006) Zhou X, Liang ZP, Gewalt SL, et. al., A Fast Spin-Echo technique with Circular Sampling, Magn. Reson.. Med.,, 39:23-27 27 (1998) 28