SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

Similar documents
SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Readme SiVArc V14 SP1 Update 6

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC. SIMATIC Logon V1.6. Security information 1. Conditions for secure operation of SIMATIC Logon 2. User management and electronic signatures 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

Siemens Drives & PLCs

SIMATIC. Industrial PC Microsoft Windows 10. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Optional package printer driver V1.4

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

PD PA AP How To Configure Maxum II TimeServer Access

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC NET. Industrial Remote Communication TeleService TS Gateway. Preface. Application and properties. Installation, commissioning and operation 2

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

SIMATIC. Process Control System PCS 7 Symantec Endpoint Protection 11.0 Configuration. Using virus scanners 1. Configuration 2. Commissioning Manual

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0 Update 1) Security information 1. Preface 2. Basics 3

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SINETPLAN Siemens Network Planner

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

B.Data V6.0 SP1 Installation SIMATIC. B.Data V6.0 SP1 Installation. Introduction 1. Installing B.Data. Setting up B.Data Web

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect. Preface. Connecting the SINEMA RC Server to the WAN 1

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Process Historian Administration SIMATIC. Process Historian V8.0 Update 1 Process Historian Administration. Basics 1. Hardware configuration 2

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

SIMATIC. TIA-Portal SIMATIC Visualization Architect. Security information 1. Basics 2. Installation 3. Elements and basic settings 4

Plant Automation Accelerator 2.1 Readme (Online)

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

MindSphere. MindConnect IoT Extension Getting Started. Introduction to MindSphere. Prerequisites 2. Preparations 3. MindConnect IoT Extension

SIMATIC. PCS 7 Process Control System CFC Readme V9.0 SP2 Upd2 (Online) Security information 1. Overview 2. Notes on Installation 3.

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

SIMATIC. PCS 7 process control system PCS 7 Basis Library Readme V9.0 (Online) Security information 1. Overview 2. Notes on installation 3

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

SIMATIC. Process Historian 2014 SP2 SIMATIC Process Historian. Process Historian - Installation Notes 1. Process Historian - Release Notes

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. PCS 7 Process Control System Support and Remote Dialup. Security information 1. Preface 2. Support and Remote Dialup 3.

SIMATIC IPC DiagMonitor SIMATIC. Industrial PC. SIMATIC IPC DiagMonitor. Introduction. SIMATIC IPC DiagMonitor. software components.

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC. Process Control System PCS 7 SFC Visualization (V9.0 SP2) Security information 1. What's new in SFV? 2. SFC Visualization (SFV) 3

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMATIC IPC227D Bundles, SIMATIC. IPC277D Bundles SIMATIC. Embedded Automation SIMATIC IPC227D Bundles, SIMATIC IPC277D Bundles.

SIMATIC. Process Control System PCS 7 Compendium Part D - Operation and Maintenance (V8.2) Security information 1. Preface 2

SIMATIC. Process Control System PCS 7 Software update with utilization of new functions. Security information 1. Preface 2.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC Industrial PC. Panel Drivers and Tools V1.3 PDT IFP Monitor Standard. Preface. Panel Drivers and Tools software. IPC Configuration Center

Settings. Prior information notice 1. Introduction to "Settings" 2. User rights in "Settings" 3. Settings interface 4.

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

MCIS DNC Cell/Plant SINUMERIK. Motion Control Information System MCIS DNC Cell/Plant. Introduction 1. Prerequisite. Installation 3.

SIMATIC. S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory. Preface. Documentation guide. Memory areas and retentive memory

SIMATIC. STEP 7 (TIA Portal) Global library "Sample Library for Instructions" Disclaimer. Basic information on the library.

Class: POptions 1 COMOS. Platform Class documentation POptions_dll. Programming Manual 04/2014 A5E AA

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

COMOS. Operations MRO. Introduction 1. Maintenance objects 2. "General maintenance" plugins 3. "Events" plugin 4. "Resources" plugin 5

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC HMI. WinCC V7.4 SP1 WinCC/Audit. WinCC/Audit - Installation Notes 1. WinCC/Audit - Release Notes 2. WinCC/Audit - Documentation.

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Continuous Function Chart Getting. Started SIMATIC. Process Control System PCS 7 Continuous Function Chart Getting Started.

Examples for SIMATIC IPC Support. Package for VxWorks SIMATIC. Industrial PC Examples for SIMATIC IPC Support Package for VxWorks

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

SIMATIC. Process Control System PCS 7 V7.0 SP1 Security Information Note: Setting up antivirus software. Preface. Using virus scanners 2

Transcription:

Safety instructions 1 Initial startup: Commissioning the operating 2 system SIMATIC Industrial PC Microsoft Windows Embedded Standard 7 Restoring the factory settings of the operating system and 3 partitions (Restore) Configuring and updating the operating system 4 Functional scope depending on the data storage medium 5 Operating Instructions 11/2017 A5E42312666-AB

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Digital Factory Postfach 48 48 90026 NÜRNBERG GERMANY A5E42312666-AB P 11/2017 Subject to change Copyright Siemens AG 2017. All rights reserved

Table of contents 1 Safety instructions... 4 1.1 Industrial Security... 4 1.2 Disclaimer for third-party software updates... 5 1.3 Notes on protecting administrator accounts... 5 2 Initial startup: Commissioning the operating system... 6 3 Restoring the factory settings of the operating system and partitions (Restore)... 7 4 Configuring and updating the operating system... 9 4.1 Changing the region and formats of the operating system... 9 4.2 Changing the display language of the operating system... 10 4.3 Updating the operating system... 11 4.4 BitLocker with Trusted Platform Module (TPM)... 11 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF)... 12 4.5.1 The Enhanced Write Filter (EWF)... 12 4.5.2 File Based Write Filter (FBWF)... 12 4.5.3 Comparison between EWF and FBWF... 13 4.5.4 Requirement of enabling EWF... 13 4.5.5 Configuring EWF in a command line window... 14 4.5.6 Configuring EWF with the SIMATIC IPC EWF Manager... 14 4.5.7 Configuring FBWF in a command line window... 15 5 Functional scope depending on the data storage medium... 16 Index... 18 Operating Instructions, 11/2017, A5E42312666-AB 3

Safety instructions 1 1.1 Industrial Security Industrial Security Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit (http://www.siemens.com/industrialsecurity). Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under (http://www.siemens.com/industrialsecurity). See also Technical Support (https://support.industry.siemens.com) 4 Operating Instructions, 11/2017, A5E42312666-AB

Safety instructions 1.2 Disclaimer for third-party software updates 1.2 Disclaimer for third-party software updates This product includes third-party software. Siemens AG only provides a warranty for updates/patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG. Otherwise, updates/patches are undertaken at your own risk. You can find more information about our Software Update Service offer on the Internet at Software Update Service (http://www.automation.siemens.com/mcms/automation-software/en/software-updateservice). 1.3 Notes on protecting administrator accounts A user with administrator privileges has extensive access and manipulation options in the system. Therefore, ensure there are adequate safeguards for protecting the administrator accounts to prevent unauthorized changes. To do this, use secure passwords and a standard user account for normal operation. Other measures, such as the use of security policies, should be applied as needed. Operating Instructions, 11/2017, A5E42312666-AB 5

Initial startup: Commissioning the operating system 2 An operating system with installed device drivers and SIEMENS software products is already installed on your device in the delivery state. After the initial startup, you can make the following personal settings using the menu: Set the display language and region Create a user account Requirements No USB data storage media are connected to the device. For devices with optical drives: There is no data storage medium in the optical drive. A keyboard, a mouse and a monitor are connected to the device. The default settings in the BIOS Setup are unchanged before the operating system is commissioned. Procedure NOTICE Operational safety of the device and system in danger Faulty or interrupted commissioning of the operating system can put the operational safety of your device and the system at risk. Therefore, note the following: Do not switch off the device during commissioning. 1. Switch on the device. 2. The operating system sets up automatically. During this process, the device can restart several times. 3. Wait until you are prompted to select the language. 4. Type in the product key as required. The product key is located on the "Certificate of Authenticity" label (COA label) or on an enclosed "Certificate of Authenticity Card". 5. Follow the instructions on the screen. Once the user has logged on for the first time and the Windows user interface has loaded, the operating system is fully operational. 6 Operating Instructions, 11/2017, A5E42312666-AB

Restoring the factory settings of the operating 3 system and partitions (Restore) The Restore function restores the factory settings of the target system (which means the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). You can quickly restore your device if it is damaged. Setting Boot mode Note We recommend that you restore the target system in the Boot mode that was set in the delivery state. You can find information on this in the operating instructions of the device. You can restore the target system in the following two boot modes: UEFI mode (GPT volume): To support new features, such as TPM 2.0 and volumes larger than 2 TB, the operating system must be restored in the way that it boots in UEFI mode. For this purpose, the provided USB stick must also be booted in UEFI mode. The target system is then set up with a GPT volume and boots in UEFI mode. Legacy mode (MBR volume): To support certain extensions and functions, such as older PCI(e) cards, EWF (Enhanced Write Filter), and older software products, the operating system must be restored to boot in Legacy mode. For this purpose, the provided USB stick must also be booted in Legacy mode. The target system is then set up with an MBR volume and boots in Legacy mode. Requirements If the data of partition D: (Data) should be retained during restore (see section "Selecting the partitions to be restored"), be aware of the following requirement: The complete target system is partitioned as in the delivery state. The target system is restored in the Boot mode that was set in the delivery state. You can find information on the delivery state in the operating instructions of the device. Operating Instructions, 11/2017, A5E42312666-AB 7

Restoring the factory settings of the operating system and partitions (Restore) Procedure Note In order for the device to boot from the provided USB stick, this may have to be set in the BIOS settings. You can find information on this in the operating instructions of the device. NOTICE Risk of data loss Files, user settings as well as existing authorizations and license keys are lost when a restore is performed! Back up your data before restoring. 1. Insert the provided USB stick into the device. 2. Restart the device. 3. Boot with the provided USB stick in the Boot mode you have set beforehand. 4. In the Windows Boot Manager, select the option "Restore Microsoft Windows..." and confirm the selection. The Restore program from Siemens starts after a few seconds. 5. Follow the instructions on the screen. Note the following information: Selecting the partitions to be restored Option: "Restore complete system disk" Use this option if you want to restore the entire target system, including the partitions C: (System) and D: (Data). Option: "Restore existing system partition only" Use this option if you are want to restore only the C: (System) and the boot functionality. The partition D: (Data) and all data stored there is retained. 8 Operating Instructions, 11/2017, A5E42312666-AB

Configuring and updating the operating system 4 4.1 Changing the region and formats of the operating system Changing the settings of the logged-in user account 1. Select: "Control Panel > Region and Language". 2. Make the desired changes in the following tabs: "Formats" "Location" "Keyboards and Languages" Changing the system account and the standard user account settings You can change the settings for the display language, region and formats of the system account (for example, the display language in the user login dialog) and the settings of the standard user account (default setting for new users). The settings of the registered user are copied to the system account and the standard user account for this purpose. 1. Select: "Control Panel > Region and Language". 2. Make the desired changes in the following tab: "Administrative" Operating Instructions, 11/2017, A5E42312666-AB 9

Configuring and updating the operating system 4.2 Changing the display language of the operating system 4.2 Changing the display language of the operating system The provided USB stick contains display languages for the operating system and tools for changing these display languages. Note Observe the licensing conditions Note the license terms for using Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 8" document provided and on the system drive under: \Windows\System32\license.rtf Procedure Note In order for the device to boot from the provided USB stick, this may have to be set in the BIOS settings. You can find information on this in the operating instructions of the device. 1. Insert the provided USB stick into the device. 2. Restart the device. 3. Boot from the provided USB stick. The Restore program from Siemens starts after a few seconds. 4. Select the option "Manage language packages" from the selection menu. 5. Make the desired changes. 10 Operating Instructions, 11/2017, A5E42312666-AB

Configuring and updating the operating system 4.3 Updating the operating system 4.3 Updating the operating system As described in the section "Industrial Security (Page 4)", we recommend updating the operating system as soon as the appropriate updates are available. Requirements You have administrator rights for the system. The device is connected to the Internet. Procedure 1. Select "Control Panel > Windows Update > Check for updates". Windows determines the updates that are not installed. 2. Then start the download and installation process. 4.4 BitLocker with Trusted Platform Module (TPM) "BitLocker" drive encryption can be used together with the "Trusted Platform Module" (TPM). To be able to use TPM, the TPM functionality must be activated in the BIOS setup and the operating system must be booted in UEFI mode. NOTICE Risk of data loss if the password is lost If the password for data encryption is lost, it will no longer be possible to decrypt the data, for example, after a BIOS update. Please store your passwords with care and protect them from unauthorized access. Operating Instructions, 11/2017, A5E42312666-AB 11

Configuring and updating the operating system 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF) 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF) 4.5.1 The Enhanced Write Filter (EWF) The Enhanced Write Filter is a configurable write filter, which makes it possible to assign write-protection to individual partitions of data storage media, such as memory cards or SSDs. Among other things, the EWF can be used to minimize write access to flash drives. This is important because the number of write cycles is limited with flash drives, such as SSDs, CompactFlash cards or CFast cards. We recommend using the EWF when using these flash drives. Note EWF is disabled in the delivery state. Note that memory is reduced when EWF is enabled. NOTICE Risk of data loss with enabled EWF When the EWF is enabled, all changes made to the C: partition (system) after the boot process are lost when the device shuts down. Proceed as follows to prevent this situation: Make the changes to the C: partition (System) only when EWF is disabled. or: If the EWF is enabled, back up the changes made to the C: partition (System) in a command line window with the command ewfmgr c: -commit. 4.5.2 File Based Write Filter (FBWF) In contrast to EWF, the file-based write filter works on the data level. When you enable FBWF, the folders C:\FBWF and D:\FBWF are authorized for writing by default. Note FBWF is disabled in the delivery state. Note that memory is reduced when FBWF is enabled. 12 Operating Instructions, 11/2017, A5E42312666-AB

Configuring and updating the operating system 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF) 4.5.3 Comparison between EWF and FBWF EWF Protects the partitions based on sectors Can be use together with HORM or compressed NTFS FBWF Protects all files and folders of a partition, except for those defined in the exception list. Can be configured more flexibly than EWF. Enables direct copying without rebooting NOTICE Risk of data loss when several write filters are enabled simultaneously The write filters EWF and FBWF are integrated in the operating system. If several write filters are active on one partition at the same time, data loss may occur. This may damage the machine or plant. Make sure that you only activate one write filter for each partition. 4.5.4 Requirement of enabling EWF If you want to enable EWF, disable automatic changeover of daylight saving time and standard time. Follow these steps: 1. Select "Control Panel > Date and Time". 2. In the "Date and Time" tab, click on the "Change time zone..." button. 3. Enable the "Automatically adjust clock for Daylight Saving Time" option and confirm the change. Operating Instructions, 11/2017, A5E42312666-AB 13

Configuring and updating the operating system 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF) 4.5.5 Configuring EWF in a command line window 1. Open a command line window with administrator rights. 2. To configure EWF, enter the following commands: Function Command Note Write-protect drive C: Power on ewfmgr c: -enable There has to be a space after the drive letter and colon. Write-protect drive C: disable: ewfmgr c: There has to be a space after -commitanddisable The changed data are applied. the drive letter and colon. Modified files on drive C: apply ewfmgr c: -commit There has to be a space after the drive letter and colon. Display information about the ewfmgr c: EWF drive Display help ewfmgr /h Note The EWF command ewfmgr c: -commitanddisable may not be used with the option -live. 3. Restart the device. The settings made are then applied. 4.5.6 Configuring EWF with the SIMATIC IPC EWF Manager 1. Select "Start > All Programs > Siemens Automation > SIMATIC > EWF-Manager > EWF-Settings". 2. Make the desired settings. 3. Restart the device. The settings made are then applied. 14 Operating Instructions, 11/2017, A5E42312666-AB

Configuring and updating the operating system 4.5 Enhanced Write Filter (EWF) and File Based Write Filter (FBWF) 4.5.7 Configuring FBWF in a command line window 1. Open a command line window with administrator rights. 2. To configure FBWF, enter the following commands: Function Command Note Display current FBWF status fbwfmgr /displayconfig Enable FBWF after the next fbwfmgr /enable restart Copy protected files fbwfmgr /commit c: \Test.txt Add/remove items in the exception list: Add file Add folder Remove file Remove folder Calling the help function fbwfmgr /? 3. Restart the device. Only existing files and folders can be entered in the exception list. fbwfmgr /addexclusion C: \Test.txt There has to be a space after the drive letter and colon. fbwfmgr /addexclusion C: \Test folder There has to be a space after the drive letter and colon. fbwfmgr /removeexclusion C: \Test.txt There has to be a space after the drive letter and colon. fbwfmgr /removeexclusion C: \Test folder There has to be a space after the drive letter and colon. The changes for direct write access take effect after a restart. You can find a detailed guide to FBWF on the Internet (http://msdn.microsoft.com/enus/library/aa940926(winembedded.5).aspx). Operating Instructions, 11/2017, A5E42312666-AB 15

Functional scope depending on the data storage 5 medium The overview shows the most important device functions under Windows Embedded Standard 7 based on the data storage medium medium that has been ordered: Function HDD / SSD version Memory card version.net Framework Available, V3.5 Available, V3.5 Accessories Available Available Aero background Available Available Backup and Restore Available Available Bluetooth Available Available Dialog box filter Available Available DirectX and Windows Device Experience Available, V11 Available, V11 Domain services Available Available Driver database Available Not available Driver frameworks Available Available Encrypted File System (EFS) Available Available Enhanced Write Filter Available Available Fax and Scan Available Available File Based Write Filter (FBWF) Available Available Fonts 134 48 Help and Support Engine Available Available Hibernate Once Resume Many (HORM) Available Available Image Mastering API V2 Available Available IME Base Components Available Available Internet Explorer Available, IE 11 Available, IE 11 Internet Information Server (IIS) Available,V7.0 Available, V7.0 Language (Standard) English 1 English 1 Mobility Center Available Available Network and Sharing Center Available Available Network Diagnostics Available Available Pagefile Available Available Printing Utilities and Management Available Available Registry Filter Available Available Remote Assistance Available Available Remote Client Available Available Remote Desktop Available Available SIMATIC IPC DiagBase Available Available Speech Available Not available System Management Administrative Tools Available Available 16 Operating Instructions, 11/2017, A5E42312666-AB

Functional scope depending on the data storage medium Function HDD / SSD version Memory card version Telnet Server Available Available User Account Control Available Available Windows Explorer Shell Available Available Windows Firewall Available Available Windows Installer Available Available Windows Media Player Available, V12 Available, V12 Windows PowerShell 2.0 Available Available Windows Search and Natural Language 6 Available Available Windows Security Center Available Available Windows Update Available Available Wireless Networking Available Available 1 Read the license agreements for Windows Embedded Standard 7. Operating Instructions, 11/2017, A5E42312666-AB 17

Index B Boot mode Legacy mode, 7 UEFI mode, 7 C Certificate of Authenticity, 6 COA label, (Certificate of Authenticity) D Delivery state, 7 Display languages of the operating system Changing, 10 E Enhanced Write Filter, (EWF) EWF, 12 Configuring in a command line window, 14 Configuring with the SIMATIC IPC EWF Manager, 14 EWF and FBWF Comparison, 13 F FBWF, 12 Configuring in a command line window, 15 File Based Write Filter, (FBWF) G GPT volume, 7 M MBR volume, 7 O Operating system Setting the region and formats, 9 Updating, 11 P Product key, 6 R Restore, 7 S Standard user account, 9 Switching on, 6 System account, 9 T Target system, 7 Trusted Platform Module, (TPM) U UEFI mode Restore, 7 Update Operating system, 11 L Legacy mode Restore, 7 18 Operating Instructions, 11/2017, A5E42312666-AB