AIRNET 11Mb CPE BRIDGE. Installation Guide

Similar documents
WL-5450AP & WL-5460AP Wireless Access Point. User s Guide

802.11a/b/g Access Point. User s Guide

2.4 GHz IEEE g 54Mbps Wireless LAN 2-WAY Access Point

802.11b/g Access Point WL-8000AP

WL-5420AP. User s Guide

Quick Installation Guide

Quick Installation Guide

XG-520 Wireless b/g Portable Router. User s Manual

Wireless LAN Access Point

Wireless g AP. User s Manual

Wireless b/g Portable Router. User s Guide

R2 BaseStation. Quick Installation Guide

802.11a g Dual Band Wireless Access Point. User s Manual

CE MARK WARNING LIMITED WARRANTY

R1 Extender. Quick Installation Guide

MULTIBAND Dual Radio V4

R2 Extender. Quick Installation Guide

Wireless LAN Access Point

Wireless G Broadband Travel user manual Model

Wireless LAN Access Point

Chapter 1 Introduction

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR-CPE90

Quick Installation Guide

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR CPE-80

Wireless Bridge User Manual. Version 1.0

Table of Contents. Chapter 1Introduction Package Contents Features Specifications Physical Description...

WUG2690 User s Manual

A Division of Cisco Systems, Inc. Dual-Band. GHz g a. Dual-Band. Wireless A+G. Access Point. User Guide WIRELESS WAP55AG. Model No.

CWA-854HT 54 Mbps Wireless-G High Transmission Access Point User s Guide

A Division of Cisco Systems, Inc. GHz g. Wireless-G. User Guide. Exterior Access Point WIRELESS WAP54GPE. Model No.

LevelOne. User Manual. WAP Mbps PoE Wireless AP V3.0.0

AP-Ext-N User Manual

11b/g Wireless Outdoor Multi- Client Bridge/AP

IEEE b/g/n Wireless Outdoor CPE. Quick Installation Guide

802.11b+g Wireless LAN USB Adapter. User Manual

WL556E Portable Wireless-N Repeater

EnGenius EAP N Multi-Function AP/Repeater

ZAC / ZAC ZAC Wireless Access Point

Dolphin-M. User s Manual

ZAC / ZAC ZAC Wireless Access Point

Wireless 11n Smart Repeater AP (1T1R)

11Mbps Wireless LAN Smart Station Adapter

11a/b/g Outdoor Wireless Multi-Client Bridge/AP. User s Manual Version: 2.1

Raylink WISP AP Controller User Guide Ver. 1

11Mbps Wireless LAN Smart Access Point

High Power g Wireless USB Adapter USER MANUAL 1.0.0

NM6000 User's guide v1.2

Figure 35: Active Directory Screen 6. Select the Group Policy tab, choose Default Domain Policy then click Edit.

Chore-Tronics Mobile Server

Installation Guide BS11 BS52 / BS51 BS52/23 / BS51/23 BS5432 / BS5431 BS5432i / BS5431i BS5411i / BS2411i SU51 / SU51/23 Revision 2.

Part I: External Installation Direction

Light Mesh AP. User s Guide. 2009/2/20 v1.0 draft

Table of Contents. Page ii

Wireless Access Point

LiteStation2 LiteStation5 User s Guide

D-Link AirPlus G DWL-G700AP

APC-100. IEEE g Wireless USB Adapter. User s Guide v1.0

AIRNET 54Mb b/g High Power USB Adapter. User s Manual

WH-9200AP a/b/g Dual Radio Wireless Base Station. User s Manual

XAVi Technologies Corporation Tel: Fax: F, No. 129, Hsing Te Road, Sanchung City, Taipei County 241, Taiwan

Federal Communication Commission Interference Statement

GRE AMERICA, INC. Wireless LAN USB Client Instllation

airhaul Nexus sb3010

Wi-Fi homeplug LN-554. User Manual

IEEE g Wireless PC Card. User s Guide

EnGenius M2000 Wireless Outdoor Access Point / Client Bridge / Mesh User Manual Version: 1.0

Chapter 1 Introduction

WL 5011s g Wireless Network Adapter Client Utility User Guide

PRODUCT OVERVIEW... 6 INSTALLATION...

EAP N Multi-Function AP/Repeater

WiFi Setup Guide. Overview. Before you start

AirCruiser G Wireless Router GN-BR01G

Quick Installation Guide

Installation Guide BS 100/200/300 Series

Wireless-G Router User s Guide

RE.41.LGTW - L-gateway - Modular IoT Base Station Quick Installation Guide

Wireless Access Point

OUTDOOR INSTALLATION WARNING

WLA-5000AP Access Point Mode

Wireless LAN Device Series CPE2615. User Manual. v

Cube Camera with Fixed Lens Hardware Manual D11, D12. Ver. 2013/05/17

Security SSID Selection: Broadcast SSID:

Wireless LAN Device Series CPE2615. User Manual. v

Hardware overview. Package contents V-M200, documentation, three antennas, and power supply.

OSBRiDGE 24XL(i) Configuration Manual. Firmware 2.05b9

LP-2396K Outdoor 2.4GHz Wireless AP/CPE/Bridge

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 12/2012

Wireless Broadband Router

CERIO Corporation OW-310N2

pakedgedevice&software inc.

BOSSW221. User Manual

PowerStation2 LiteStation2 LiteStation5 User s Guide

54Mbps g Wireless LAN. CardBus PC Card. user manual

MIMO Wireless Broadband Route r User s Manual 1

FCC Warning statement:

EOC User s Manual. Wireless Outdoor Access Point & Client Bridge V1.0

11g Wireless Client Bridge/AP. User s Manual Version: 1.36

User Manual of 5.8G Outdoor CPE

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. Access Point WIRELESS WAP54G (EU/LA/UK) Model No.

Owner s Instruction Manual

Transcription:

AIRNET 11Mb CPE BRIDGE Installation Guide

Copyright 2005 by Netkrom Technologies Inc. All rights reserved. This publication conveys information that is the property of Netkrom Technologies Inc. It shall not be copied, reproduced or duplicated in whole or in part without the express written permission of Netkrom Technologies Inc. The information contained herein is subject to change without notice. Document version 1.0 Published by Netkrom Technologies Inc. SALES Address: Netkrom Technologies Inc. 3152 NW 72nd Ave Miami, FL 33122 U.S.A. Phone: +1 305-4182232 Fax: +1 305-4182232 Email: sales@netkrom.com TECHNICAL SUPPORT Address: Netkrom Technologies Inc. 3152 NW 72nd Ave Miami, FL 33122 U.S.A. Phone: +1 305-4182232 Fax: +1 305-4182232 Email: support@netkrom.com INTERNET Web: www.netkrom.com Limited Warranty Netkrom Technologies Inc. Limited Warranty Netkrom Technologies Inc. ( Netkrom ) makes the following limited warranty. This limited warranty extends to the original consumer purchaser and to no other purchaser or transferee. Limited One (1) Year Parts and Labor Warranty for Netkrom CPE Unit. Netkrom warrants this product and its parts against defects in materials and/or workmanship for a period of one (1) year after the date of original retail purchase. During this period, Netkrom will repair or replace a defective product or part without charge to you. Warranty Conditions The above LIMITED WARRANTY is subject to the following conditions: 1.Warranty extends only to products distributed by Netkrom. 2.Warranty extends only to defects in materials and/or workmanship as limited above. Warranty extends only to defects which occur during normal use and do not extend to damage to products or parts which results from alternation, repair, modification, faulty installation or service by anyone other than an Authorized Netkrom Service Center; damage to products or parts caused by accident, abuse, or misuse, or maintenance, mishandling, misapplication, or use in violation of instructions furnished by us; damage which occurs in shipment or any damage caused by acts of God, such as lightening or line surges. 3.You must retain your bill of sale or provide other proof of purchase. 4.Any replacement parts furnished at no cost to the purchaser in fulfillment of this warranty are warranted only for the unexpired portion of the original warranty.

Obtaining Warranty Service If your Netkrom product is still under warranty, visit the Netkrom website at www.netkrom.com/rma.htm to request a return merchandise authorization ( RMA ) number. An RMA number will be issued and emailed to you. Authorized Netkrom Service Centers or Netkrom will not accept any returned product without an RMA number. Ship the product to Netkrom, postage prepaid, together with your bill of sale of other proof of purchase, your name, address, description of the problem(s), and the RMA number you have obtained from Netkrom. All products returned for warranty service must be carefully packaged in the original packing materials. ALL WARRANTY REQUIRED TO BE IMPLIED BY STATE LAW ARE EXPRESSLY LIMITED TO THE DURATION OF THE LIMITED WARRANTY SET FORTH ABOVE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. WITH THE EXCEPTION OF ANY WARRANTIES REQUIRED TO BE IMPLIED BY STATE LAW AS HEREBY LIMITED, THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES. IN NO EVENT SHALL Netkrom BE LIABLE FOR SPECIAL, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, INCLUDING, WITHOUT LIMITATION, DAMAGE TO THE PROPERTY CAUSED BY ANY DEFECT IN THIS PRODUCT, INCONVENIENCE, LOSS OF GOODWILL, LOST PROFITS OR REVENUE, LOSS OF USE OF THIS PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF SUBSTITUTIVE EQUIPMENT, DOWNTIME COSTS OR CLAIMS OF ANY PARTY DEALING WITH PURCHASER FOR SUCH DAMAGES, RESULTING FROM THE USE OF THIS PRODUCT, OR ANY OTHER LEGAL THEORY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE. For more information, please call (305) 4182232 Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modifications made to this equipment may void a user s authority to operate this equipment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation.

Table of Contents Section 1: Introduction...1 System Overview...1 Safety Precautions...1 Important Notes...2 Section 2: Before You Begin...3 Verify Contents of Installation Kit...3 Tools and Hardware Needed...3 Section 3: Selecting a Location for the CPE...4 Section 4: Installing the Netkrom CPE Unit...5 Assemble the CPE...5 Mount the CPE...6 Connect the Cat 5 Cable to Power Supply and PC... 8 Aim the CPE... 8 Secure the CPE and Cable... 9 Section 5: Configuring the Netkrom CPE Unit...11 Operation Mode...11 LOGIN...11 STATUS...12 System...12 System Log...13 Statistics...14 Active Clients...14 Basic Settings...15 Advanced Settings...16 Security...19 Access Control...21 Site Survey...22 WDS Setting...22 TCP/IP...23 Basic...23 Web Redirection...25 DHCP Relay...25 SNMP...26 OTHER...28 Upgrade Firmware...28 Reboot...28 Save/Reload Settings...29 Password...30

Section 1: Introduction Pag 1 The Netkrom CPE Unit offers a cost-effective alternative to accessing the Internet or a corporate network through expensive dedicated phone lines or fiber networks. It provides the high-performance, cost effective LANto-LAN (local area network) and LAN-to-WAN (wide area network) connectivity that is ideally suited for a wireless network or wireless Internet access. System Overview Wireless data is transmitted from a base station antenna to a receiving antenna called the Netkrom CPE Unit, or CPE for short. ( CPE stands for customer premises equipment. ). The radio signals used to send and receive data from the CPE is a line of sight signal, meaning that data can only be sent or received if there is an unobstructed path between the central Base Station or remote antenna and the Netkrom CPE Unit. Safety Precautions WARNING! Serious injury or death can occur if proper safety precautions are not taken during the installation of this equipment. The U.S. Consumer Product Safety Commission advises consumers to use the following precautions when installing an antenna.

Site Selection: Pag 2 Select a safe site to install the CPE. The distance between any power lines and the installation site should be at least one and one-half times the height of the CPE and mast assembly. Make the distance even greater, if at all possible. Since all overhead power lines look somewhat alike, consider them all dangerous and stay well away from them. If you have power lines in the area, call your local electric utility for assistance. CPE Mounting: NEVER work alone; always have someone near who can summon help. Certain clothing may provide a degree of safety, but don't depend on it for your life (rubber boots or shoes, industrial rubber gloves and a long sleeve shirt or jacket). Check weather conditions. Be sure that it hasn't rained recently and that the lawn is not wet or muddy. Make sure that rain or thunderstorms are not predicted for the day you decide to install the CPE. The wind can blow the CPE into a nearby power line. Don't install or remove CPE in moderate or heavy winds. If you need to use a ladder, make sure it is made of non-conductive (non-metallic) material. (This is a safety rule that you should follow whenever you're working with electrical equipment.) If possible, have someone present who has been trained in electric shock first aid. CPE Installation: Properly assemble the CPE according to instructions (do this where the CPE is to be put up). Once the CPE is up in full vertical position, securely fasten it by tying it to the side of the house or by using guy wires. Ground the CPE according to the National Electrical Code. Rooftop Installations: DO NOT assume that just because you're on a roof, you're isolated from ground. You may still be electrocuted or fall off the roof. Important Notes Read all instructions prior to installing any of the enclosed equipment. Pay particular attention to the warnings associated with the installation of the CPE. It is highly recommended that the installation of this equipment is done by a trained professional if you are not experienced with installation of communications equipment. Tampering with or breaking the seal on Netkrom CPE Unit back plate voids any warranty coverage on the CPE and will result in full equipment charge to the customer.

Section 2: Before You Begin Pag 3 Verify Contents of Installation Kit Take a moment to ensure you have all of the following parts in your Netkrom CPE Unit installation kit before you begin installing the CPE. If any parts are missing, please contact Netkrom at 305-4182232 CPE BRIDGE ONLY 1. AIRNET CPE Bridge Unit 2. Antenna Mounting bracket (include: stainless steel U-Bolts, Flange Nuts, and saddle clamps) 3. PoE Injector with 100-240v Power supply 4. Product CD CPE BRIDGE POINT TO POINT KIT 1. (02) AIRNET CPE Bridge Unit 2. (02) Antenna Mounting bracket (include: stainless steel U-Bolts, Flange Nuts, and saddle clamps) 5. (02)Wall Mount Bracket 3. (02)PoE Injector with 100-240v Power supply 4. (02)75 UTP Cat5 Outdoor Cable 5. (02)Product CD Tools and Hardware Needed The following tools will be needed to assemble and mount your CPE: Crescent wrench, channel locks, or a small pipe wrench Phillips head screw driver Pipe and other hardware on which to mount the CPE (See Mount the CPE on page 6 for illustration.) Cable ties and other hardware with which to secure the exterior Cat 5 cable to the CPE and building (See Secure the CPE and Cable on page 9 for illustration.)

Section 3: Selecting a Location for the CPE Pag 4 It is very important to position the Netkrom CPE and its antenna(s) to ensure the highest possible data transfer speed in all kinds of weather and in all seasons. The Netkrom CPE operates on a radio frequency of 2.4 GHz and must be line-of-sight (LOS) with its clients. Hills, buildings, trees and large vehicles must not block the signal path. Trees are especially troublesome as they may allow the signal to pass easily in winter when leaves are off, but may block the signal in the other seasons. Choose a location on the roof, tower, mast or wall for your Netkrom CPE and antenna(s) so that it has a clear shot to your base station or remote point. The closest client may not necessarily have the best path if it is blocked by hills, buildings or trees. Ensure that the signal path to each client has sufficient Fresnel zone clearance with respect to the ground or other obstacles near the path. Check the Netkrom FAQ s under Radio Propagation for more information on Fresnel zone clearance. Ensure that your mounting location is less than 100 meters from the computer, hub, switch or router location. (Maximum length of CAT-5 cable is 100 meters) Determine the building entry point ahead of time to prevent problems later.

Section 4: Installing the Netkrom CPE Unit Pag 5 This section describes how to assemble and mount your Netkrom CPE Unit. Assemble the CPE Note: Tampering with or breaking the seal on the back plate of your CPE voids any warranty coverage on the CPE. Do the following to assemble the CPE: 1. Attach the mounting bracket to the back of the CPE using the four hex screws provided. (Do not overtighten the screws.) Note: The bracket in the illustration above shows the normal orientation which allows the CPE to be pointed up towards the base station antenna. However, if you live somewhere that would require you pointing the CPE down towards the base station antenna (for example, you are on the side of a mountain in view of the base station antenna below), reverse the bracket so the Netkrom CPE Unit can be tilted downward when you aim the CPE in a later step. 2. Remove the U-bolt and pipe bracket assembly from the pink plastic. Place the washer, lock washer and nut to each side of the bolt, and then tighten until the bolts are approximately 1/4" from the end. Note: Do not tighten the screws all the way because you will need to adjust the CPE direction in a later step.

Mount the CPE Pag 6 WARNING: Netkrom strongly recommends you have a trained professional do the installation if you do not have experience installing communications equipment. If you choose to install this equipment yourself, you do so at your own risk. Do the following to mount the CPE: 1. Review the safety precautions on page 3, and make sure you have all the tools and equipment needed to install the CPE. 2. Mount the CPE in the Wall Mount Bracket and point the CPE in the approximate direction of the base station antenna or other CPE for point to point mode, then hand-tighten the nuts on the U-bolt. 3. Mount the CPE to the top of the pipe or other support and point the CPE in the approximate direction of the base station antenna or other CPE for point to point mode, then hand-tighten the nuts on the U- bolt. Note: Do not tighten the screws all the way because you will need to adjust the CPE direction in a later step.

Pag 7 4. Attach the external Cat 5 cable to the back of the CPE: place the round cable connection on the cable with the round jack on the back of the CPE, gently twist the cable until it slides down, then tighten the locking ring by turning it to the right (clockwise) until it is finger-tight. The connector has a guide key and can only go on one way. Note: It is important to keep all connections clean and dry. While the connection is water resistant, getting moisture or debris in the connection will reduce or prevent transmission speed. 1 2 Note: Do not secure the exterior Cat 5 cable to the CPE or to the building at this time. You will do this after you have completed aiming the CPE in a later step. 5. Run the exterior Cat 5 cable from the CPE into the house. Determine the Cat 5 cable length needed inside the house to reach from the wall where it enters the house to the computer. Add some slack (about 3 feet) then coil the excess Cat 5 cable. DO NOT CUT OFF THE EXCESS CABLE. WARNING! If a hole is to be made in the exterior wall of the building, use extreme caution to avoid interior wiring, plumbing and other potential hazards. If the installer is not absolutely sure of the location of potential hazards, consult a qualified electrical contractor to install the exterior Cat 5 cable. 3

Connect the Cat 5 Cable to Power Supply and PC Pag 8 Do the following to connect the CPE to the power supply and to your PC: 1. Connect the end of the exterior Cat 5 cable to the of the Power over Ethernet - PoE Injector connection marked DATA/ POWER OUT (CPE). (The PoE Injector supplies the power (Direct Current) needed to get the signal to your PC.) 2. Connect the power cord to the power supply, then connect one end of the power supply to the PoE Injector (see illustration above) and plug the power cord into a 110-240v outlet. 3. Do one of the following to connect the PoE Injector to your PC. IMPORTANT NOTE: Be sure to use the correct cable when connecting the PoE Injector to your PC or network hub. Your Internet service will not function if you use the wrong cable! If you are connecting the CPE directly to your computer, connect one end of the Cross-Ever Cat 5 cable to the open connector on the PoE Injector and the other end of the Cross-Ever Cat 5 cable to the Ethernet card in your PC. Cross-Over Cable If you are connecting the CPE to a hub or router so multiple computers can share Internet access, connect one end of the Regular Cat 5 cable to the open connector on the PoE Injector and the other end Regular Cat 5 cable to the hub or router.

Pag 9 Regular Cable Aim the CPE You will need to aim the Netkrom CPE Unit directly at the Base Station or remote antenna to achieve maximum data speed. Do the following to aim the CPE: 1. Make sure the CPE is loosely mounted, the exterior Cat 5 cable is connected to the CPE the exterior Cat 5 cable is plugged into the ANT side of the PoE Injector, and the PoE Injector is plugged in. Note: You do not need to plug the Interior Cat 5 cable into your PC network interface card to aim the CPE, but you must have the Cat 5 cable connected to the PoE Injector and the PoE Injector plugged in for your CPE to acquire the signal from the base station antenna. 2. Locate the base station antenna and aim your CPE directly toward it. Secure the CPE and Cable Do the following to secure the CPE and cable: 1. When you have completed aiming the CPE, tighten the CPE mounting bracket securely so the CPE won t move in the wind or other weather. 2. Secure the Cat 5 cable the mounting pipe or other support using wire ties or other suitable hardware.

Pag 10 3. Secure the Cat 5 cable to the outside of the house with the cable clamps and 1" stainless steel screws or other suitable hardware. Note: Create a drip loop wherever the cable changes from vertical to horizontal to prevent water from traveling down the cable and into the building. Drip Loop Drip Loop Drip Loop Note: Be careful when bending the cable in cold temperatures so the outer jacket doesn t crack. 4. Pull any excess cable into the building (except for the drip-loops), and then weather seal the hole around the Cat 5 cable by applying a quality exterior grade sealant entirely around the Cat 5 cable at the point where it enters the house. 5. Keep the remainder of the Cat 5 cable kink-free by coiling any extra cable inside and securing it with a black wire tie.

Section 5: Configuring the Netkrom CPE Unit Pag 11 Operation Mode This device provides four operational applications with Access Point, Bridge, Client (Ad-hoc) and Client (Infrastructure) modes, which are mutually exclusive. for CPE Outdoor Application, only configure in two modes: Point to Point Bridge Refer to the illustration below. While acting as Bridges, CPE in building 1 (with Station 1 being associated to) and CPE in building 2 (with Station 2 being associated) can communicate with each other through wired or wireless interface (with WDS). Thus Station 1 can communicate with Station 2 and both Station 1 and Station 2 are able to access the Internet if only CPE in building 1 or CPE in building 2 has the Internet connection. To set the operation mode to Bridge, please go to Wireless --- Basic Settings, in the Mode field click the down arrow to select AP mode. And go to Wireless --- WDS Settings to enable WDS. Note: Please make sure both CPE in building 1 and CPE in building 2 are set to the same ESSID and channel CPE Client Infrastructure If set to Client (Infrastructure) mode, this device can work like a wireless station when it s connected to a computer so that the computer can send packets from wired end to wireless interface. Refer to the illustration below. This station (CPE plus the connected computer 1) can associate to another Access Point (Base Station), and then can have the Internet access if the other Access Point (Base Station) has the Internet connection. To set the operation mode to Client (Infrastructure), please go to Wireless --- Basic Settings, in the Mode field click the down arrow to select Client mode, and then select Network Type as Infrastructure.

Login Pag 12 1. Start your computer. Connect an Ethernet cable between your computer and the Wireless Access Point. 2. Make sure your wired station is set to the same subnet as the Wireless Access Point, i.e. 192.168.100.12. 3. Start your WEB browser. In the Address box, enter the following: HTTP://192.168.100.252 The configuration menu is divided into four categories: Status, Wireless, TCP/IP, and Other settings. Click on the desired setup item to expand the page in the main navigation pane. The setup pages covered in this utility are described below. Status In this screen, you can see the current settings and status of this Access Point. You can change settings by selecting specific tab described in below. System

System Alias Name Uptime Firmware Version Wireless Configuration Wireless Mode SSID Channel Number: Encryption Associated Clients BSSID You can assign a unique name to this Access Point. The alias name is especially important for identification when there are more than one Access Point is applied in a network. The time period since the device was up. The current version of the firmware installed in this device. Pag 13 There are four modes supported, Access Point, Client (Ad-hoc and Infrastructure), and Bridge. The default mode is Access Point. If you want to change to bridge mode, please go to Wireless/WDS Setting to enable the WDS function. Sensitive and must not exceed 32 characters. A device will not be permitted to join the BSS unless it can provide the unique SSID. An SSID is also referred to as a network name because essentially it is a name that identifies a wireless network. The number of channels supported depends on the region of this Access Point. All stations communicating with the Access Point must use the same channel. WEP Encryption (Wired Equivalent Privacy) is set to Disabled by default. When WEP is enabled, data packet is encrypted before being transmitted. The WEP prevents data packets from being eavesdropped by unrelated people. By using WEP data encryption, there may be a significant degradation of the data throughput on the wireless link. Displays the total number of clients associated to this AP. You can have up to 64 clients to associate to this Access Point. BSSID displays the ID of current BSS, which uniquely identifies each BSS. In AP mode, this value is the MAC address of this Access Point. TCP/IP Configuration IP Protocol br0 IP Address br0 Subnet Mask br0 Default Gateway br0 MAC Address Display the method to get the IP of this AP, which could be obtained by Fixed-IP or DHCP-client. Current IP address for this Access Point Current Subnet mask for this Access Point Default Gateway for this Access Point The MAC Address for this Access Point System Log This page display log events with time when events happened, log events types, log sources and the description for events themselves. System manager can use the system log to trace when problems occur.

Pag 14 Statistics The Statistics table shows the packets sent/received over wireless and Ethernet LAN respectively. Active Clients This page display wireless stations that are associated to this Access Point, with information of their MAC addresses, transmitted/received packets, transmitting rate, power saving mode, and expired time. Press Refresh to get the latest information.

Pag 15 Basic Settings This page includes all primary and major parameters. Any parameter change will cause the device to reboot for the new settings to take effect.

Pag 16 Alias Name: Maximum 32 characters alpha-numeric You can assign a unique name to this Access Point. The alias name is especially useful for identification when there are more than one Access Point is applied in a network. Disable Wireless LAN Interface: Check the box to disable the Wireless LAN Interface, by so doing, you won t be able to make wireless connection with this Access Point in the network you are located. In other words, this device will not be visible by any wireless station. Mode: This Wireless Access Point can support four modes AP, Client (Adhoc), Client (Infrastructure), and Bridge. The default is set to AP mode. In the Mode field Click the pull down arrow then you can change it to Client mode. To change to Bridge mode, you will have to set to AP mode, and go to Wireless/WDS setting to enable WDS. Network Type: When in Client mode, you can select between Ad-Hoc and Infrastructure. SSID: The SSID differentiates one WLAN from another, therefore, all access points and all devices attempting to connect to a specific WLAN must use the same SSID. It is case-sensitive and must not exceed 32 characters. A device will not be permitted to join the BSS unless it can provide the unique SSID. An SSID is also referred to as a network name because essentially it is a name that identifies a wireless network. Channel Number: Allow user to set the channel manually or automatically. If set channel manually just select the channel you want to specify. If Auto is selected, user can set the channel range to have Wireless Access Point automatically survey and choose the channel with best situation for communication. The number of channels supported depends on the region of this Access Point. All stations communicating with the Access Point must use the same channel. From Channel: To Channel: When select Auto in Channel Number, you have to set a range of channels for the Access Point to automatically survey and choose the channel for optimal performance. Allowed Clients Enter a number ranging from 1 to 64. Apply Change Reset Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. Advanced Settings It is not recommended that settings in this page to be changed unless advanced users want to change to meet their wireless environment for optimal performance.

Pag 17 Authentication Type Fragment Threshold To provide a certain level of security, the IEEE 802.11 standard has defined two types of authentication methods, Open System and Shared Key. With Open System authentication, a wireless PC can join any network and receive any messages that are not encrypted. With Shared Key authentication, only those PCs that possess the correct authentication key can join the network. By default, IEEE 802.11 wireless devices operate in an Open System network. Wired Equivalent Privacy (WEP) data encryption is used when the wireless devices are configured to operate in Shared Key authentication mode. If the Access Point is using "Open Authentication, then the wireless adapter will need to be set to the same authentication mode. Shared Authentication is used when both the sender and the recipient share a secret key. Select Auto for the network adapter to select the Authentication mode automatically depending on the Access Point Authentication mode. Fragmentation mechanism is used for improving the efficiency when high traffic flows along in the wireless network. If your 802.11g Wireless LAN PC Card often transmit large files in wireless network, you can enter new Fragment Threshold value to split the packet. The value can be set from 256 to 2346. The default value is 2346.

Pag 18 RTS Threshold RTS Threshold is a mechanism implemented to prevent the Hidden Node problem. Hidden Node is a situation in which two stations are within range of the same Access Point, but are not within range of each other. Therefore, they are hidden nodes for each other. When a station starts data transmission with the Access Point, it might not notice that the other station is already using the wireless medium. When these two stations send data at the same time, they might collide when arriving simultaneously at the Access Point. The collision will most certainly result in a loss of messages for both stations. Thus, the RTS Threshold mechanism provides a solution to prevent data collisions. When you enable RTS Threshold on a suspect hidden station, this station and its Access Point will use a Request to Send (RTS). The station will send an RTS to the Access Point, informing that it is going to transmit the data. Upon receipt, the Access Point will respond with a CTS message to all station within its range to notify all other stations to defer transmission. It will also confirm the requestor station that the Access Point has reserved it for the time-frame of the requested transmission. If the Hidden Node problem is an issue, please specify the packet size. The RTS mechanism will be activated if the data size exceeds the value you set.. The default value is 2347. Warning: Enabling RTS Threshold will cause redundant network overhead that could negatively affect the throughput performance instead of providing a remedy. Beacon Interval DTIM Period Data Rate Preamble Type Broadcast SSID Tx Power Level This value should remain at its default setting of 2347. Should you encounter inconsistent data flow, only minor modifications of this value are recommended. Beacon Interval is the amount of time between beacon transmissions. Before a station enters power save mode, the station needs the beacon interval to know when to wake up to receive the beacon (and learn whether there are buffered frames at the access point). DTIM stands for Delivery Traffic Indication Message. A DTIM is a countdown field informing clients of the next window for listening to broadcast and multicast messages. When the access point has buffered broadcast or multicast message for associated clients, it sends the next DTIM with a DTIM Period value. Access point clients hear and awaken to receive the broadcast and multicast messages. The default DTIM period is 3. By default, the unit adaptively selects the highest possible rate for transmission. Select the basic rates to be used among the following options: Auto, 1, 2, 5.5, or 11 Mbps. For most networks the default setting is Auto which is the best choice. When Auto is enabled the transmission rate will select the optimal rate. If obstacles or interference are present, the system will automatically fall back to a lower rate. A preamble is a signal used in wireless environment to synchronize the transmitting timing including Synchronization and Start frame delimiter. In a "noisy" network environment, the Preamble Type should be set to Long Preamble. The Short Preamble is intended for applications where minimum overhead and maximum performance is desired. If in a "noisy" network environment, the performance will be decreased. Select enabled to allow all the wireless stations to detect the SSID of this Access Point. Select the power level to transmit packets.

IAPP Apply Change Reset Pag 19 To enable IAPP means that Access Points will communicate across the backbone network, so that mobile stations can roam between them. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. Security Here you can configure the security of your wireless network. Selecting different method will enable you to have different level of security. Please note that by using any encryption, by which data packet is encrypted before transmission to prevent data packets from being eavesdropped by unrelated people, there may be a significant degradation of the data throughput on the wireless link. Encryption: None ( Encryption is set to None by default. ) If None is selected, you can still select to Use 802.1x Authentication and Enable MAC Authentication. To Enable MAC Authentication means to use client MAC address for authentication with RADIUS server If both Use 802.1x Authentication and Enable MAC Authentication are selected, the RADIUS Server will check MAC Authentication first; if the MAC Authentication passes, the 802.1x Authentication will be skipped. If not, the RADIUS Server will proceed to check the 802.1x Authentication. Encryption: WEP If WEP is selected, users will have to Set WEP keys either manually, or select to Use 802.1x to make the RADIUS server to issue the WEP key dynamically.

Pag 20 Set WEP key Use 802.1x Authentication Click the Set WEP Keys will prompt you a window to set 64bit or 128bit Encryption. Select HEXif you are using hexadecimal numbers (0-9, or A-F). Select ASCII if you are using ASCII characters (case-sensitive). Ten hexadecimal digits or five ASCII characters are needed if 64-bit WEP is used; 26 hexadecimal digits or 13 ASCII characters are needed if 128-bit WEP is used. If Use 802.1x is selected, then the Set WEP Key won t be usable. If Use 802.1x is selected, the Enable RADIUS Client will be automatically selected too. If Use 802.1x is selected and WEP is selected in Encryption field, then the authentication mechanism to the RADIUS Server will be TTLS. Encryption: WPA WPA: If WPA is selected, users will have to select the Authentication modes between WPA-RADIUS and Preshared Key, both modes need to have TKIP selected. (AES is not functional at present.) Pre-shared Key Pre-Shared-Key serves as a password. Users may key in a 1 to 63 characters string to set the password or leave it blank, in which the 802.1x Authentication will be activated. Make sure the same password is used on client's end. There are two formats for choice to set the Pre-shared key, i.e. Passphrase and Hex. If Hex is selected, users will have to enter a 64 characters string. For easier configuration, the Passphrase format is recommended. Group Key Refresh Time Enter the number of seconds that will elapse before the group key change automatically. The default is 300 seconds.

Pag 21 Apply Change Reset Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. Access Control When Enable Wireless Access Control is checked, only those clients whose wireless MAC addresses listed in the access control list can access this Access Point. If the list contains no entries with this function being enabled, then no clients will be able to access this Access Point. Enable Wireless Access Control MAC Address Comment Apply Change Reset Delete Selected Check the checkbox to enable this function. Enter the MAC Address of a station that is allowed to access this Access Point. You may enter up to 20 characters as a remark to the previous MAC Address. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. To delete clients from access to this Access Point, you may firstly check the Select checkbox next to the MAC address and Comments, and press Delete Selected.

Delete All Reset To delete all the clients from access to this Access Point, just press Delete All without selecting the checkbox. If you have made any selection, press Reset will clear all the select mark. Pag 22 Site Survey Site survey displays all the active Access Points and IBSS in the neighborhood. When you are in the client mode, you can select one AP to associate. Press Refresh to get the latest information. WDS Setting To enable WDS function will let this AP enter Bridge Mode. Two APs in bridge modes can communicate with each other through wireless interface. That is, two stations associated to different AP in bridge mode can communicate with each other. Enable WDS Add WDS AP MAC Address Apply Change Reset Current WDS AP List Delete Selected Delete All Reset Check the checkbox to enable WDS. Enter the MAC Address for the new Access Point to participate the WDS with this Access Point. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. The added Access Points for participating WDS with this Access Point are shown. You can delete the WDS Access Points listed above by marking the checkbox. You can delete all of the WDS Access Points listed above. Press to discard the data you have entered since last time you press Apply Change.

TCP/IP Pag 23 Basic In this page, you can change the TCP/IP settings of this Access Point, select to enable/disable the DHCP Client, 802.1d Spanning Tree, and Clone MAC Address. IP Address Subnet Mask Default Gateway DHCP Client This field can be modified only when DHCP Client is disabled. If your system manager assigned you static IP settings, then you will have to enter the information provided. Enter the information provided by your system manager. Enter the information provided by your system manager. To enable the DHCP Client will let the Access Point obtain IP address automatically from DHCP Server in the network.

802.1d Spanning Tree To enable 802.1d Spanning Tree will prevent the network from infinite loops. Infinite loop will happen in the network when WDS is enabled and there are multiple active paths between stations. Pag 24 Clone MAC Address Web Server Port: Apply Change Reset You can specify the MAC address of your Access Point to replace the factory setting. The web server provides the configuration service to manage this Access Point. Generally the web server port is set to 80. You can change it in this field. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change.

Web Redirection Pag 25 If Web Redirection is enabled, unauthorized clients associating to this AP will be re-directed to the specified Redirection URL when they are trying to access the Internet. Web Redirection Redirection URL Open Address 1 Open Address 2 Open Address 3 Open Address 4 Apply Change Reset Click the Enable/Disable radio button to enable/disable the function of Web Redirection. This URL (Universal Reference Locator) must be a complete one, which means you can not leave out URL protocol - http:// before the full domain name, i.e. http://www.mycompany.com. Or the web redirection will not work properly. The IP address for the URL you entered in the previous field. The IP address for your ISP s DNS. Other open IP address allowed to be connected to. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change. DHCP Relay The DHCP Relay Agent that relays Dynamic Host Configuration Protocol (DHCP) messages between DHCP clients and DHCP servers on different IP networks. The DHCP Relay Agent is compliant with RFC 1542, "Clarifications and Extensions for the Bootstrap Protocol." For each IP network segment that contains DHCP clients, either a DHCP server or a computer acting as a DHCP Relay Agent is required.

Pag 26 DHCP Relay DHCP Server Apply Change DHCP Relay is disabled by default factory. Clicking the radio button to enable DHCP relay. Enter the IP address of the DHCP server if you are using it. Press to save the new settings on the screen. SNMP SNMP is an application-layer protocol widely used to facilitate the exchange of management information between network devices. By using SNMP-transported data, network administrators can more easily manage network performance, find and solve network problems, and plan for network growth.

SNMP Setup Server Trust Host IP Trust Trap IP Agent Port Read Community Write/ReadCommunity Trap Port Trap Community Trap Version Click the radio button to enable/disable the SNMP server. You have to enable this function first to set the following settings. Enter the IP address of the NMS (Network Monitoring Stations). The NMS is the only host PC that is allowed to access this AP. If this filed is left blank, it means that every host PC is allowed to access the AP if only its Community string is correct. Enter the IP address of the SNMP Trap Receiver. Leave it blank to disable the SNMP trap function. Enter the SNMP listening port. Enter the communicty string for the NMS to read only this AP s MIB. Enter the communicty string for the NMS to read/write this AP s MIB. Enter the remote Trap Receiver port. Enter a trap community string that is used as a password for the Trap Receiver. Pag 27 SNMP Trap version 1 and 2 are both supported. Select your preference. Trap Activity Sent on redirect Sent on Auth Success (Authorization success) Sent on Auth Failure (Authorization failure) Sent WEP key failure Sent on acct failure Sent on boot Sent on reboot Sent on web start Send a trap to the Trap Receiver (already defined in the TrustTrap IP) when a station (wireless client) is redirected to the default web site. Send a trap to the Trap Receiver (already defined in the Trust Trap IP) when a station (wireless client) gets authorization from the 802.1x server (or RADIUS server). Send a trap to the Trap Receiver (already defined in the Trust Trap IP) a wireless client fails to get authorization from the 802.1x server (or RADIUS server). Send a trap to the Trap Receiver (already defined in the Trust Trap IP) when a wireless client fails to associate to the AP because of wrong WEP keys. Send a trap to the Trap Receiver (already defined in the Trust Trap IP) when the accounting server of a wireless client is invalid or fails. Send a trap when the AP has booted. Send a trap when the AP is asked to reboot itself. Send a trap once the AP web server is ready for use.

OTHER Pag 28 Upgrade Firmware 1. Download the latest firmware from your distributor and save the file on the hard drive. 2. Start the browser, open the configuration page, click on Other, and click Upgrade Firmware to enter the Upgrade Firmware window. Enter the new firmware s path and file name (i.e. C:\FIRMWARE\firmware.bin). Or, click the Browse button, find and open the firmware file (the browser will display to correct file path). 3. Click Reset to clear all the settings on this page. Or click Upload to start the upgrade. Reboot Click Reboot button to do warm system reboot of this device.

Save/Reload Setting Pag 29 This function enables users to save the current configurations as a file (i.e. config.dat) To load configuration from a file, enter the file name or click Browse to find the file from your computer. Save Settings to File: Click SAVE.. to save the current configuration to file. When prompted the upper left screen, select Save this file to disk, and the upper right screen will prompt you a dialog box to enter the file name and the file location. Load Settings From File: Click Browse if you want to load a pre-saved file, enter the file name with the correct path and then click on Upload. Or click Browse to select the file.

Pag 30 Reset: Click to restore the default configuration. Password For secure reason, it is recommended that you set the account to access the web server of this Access Point. Leaving the user name and password blank will disable the protection. The login screen prompts immediately once you finish setting the account and password. Remember your user name and password for you will be asked to enter them every time you access the web server of this Access Point. User Name New Password Confirm Password Apply Change Reset Enter your new user name to access the web server. User name can be up to 30 characters long. User name can contain letter, number and space. It is case sensitive. Set your new password. Password can be up to 30 characters long. Password can contain letter, number and space. It is case sensitive. Re-enter the new password for confirmation. Press to save the new settings on the screen. Press to discard the data you have entered since last time you press Apply Change.