INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000 This document describes the basic steps for installing your BV10-100 or BV10-1000. For detailed information about the BV10-100/1000, see the Ethernet Performance Endpoints BV10-100 and BV10-1000 User Guide. In this document This document contains the following sections: Section Page Front Panel Description 2 Installing the Units in a Rack 3 Connecting the Power 4 Connecting the Test Interface Ports 8 Connecting the Management Interfaces 11
2 Installation Instructions for the BV10-100/1000 Front Panel Description The following figures show the locations of all connectors, ports, and s available on the front panel of the BV10-100 and BV10-1000 units. BV10-1000 version Test port s Speed Link/Activity LAN port s Speed Link/Activity Console port Status Test port LAN port Power BV10-1000 version Electrical Test port s Speed Link/Activity LAN port s Speed Link/Activity Optical Test port Console port Status Test port LAN port Power Link/Activity Laser Optical Test port s
Installation Instructions for the BV10-100/1000 3 Installing the Units in a Rack The BV10-100/1000 can be mounted in a rack using the rack mount accessory kit (ordered separately). The accessory kit shelf holds up to four BV10-100/1000s. To install the BV10-100/1000 in a rack: 1 Attach the brackets of the supplied shelf unit to your rack using the supplied screws. 2 If cables have been attached to the BV10-100/1000, disconnect all of them as well as the ground lug from the unit. 3 Slide the unit into the desired slot from front to back. 4 With the unit completely inserted into the slot, tighten the thumb screw at the back of the unit. Thumb screw 5 Connect all cables and the ground lug, as explained in the next sections.
4 Installation Instructions for the BV10-100/1000 Connecting the Power The BV10-100/1000 is available with either an external brick AC power supply or an integrated DC power supply. Both AC and DC units are shipped with a grounding lug and hardware attached. The external brick AC power supply receives AC power through an IEC C14 power cord and delivers it to the BV10-100/1000 through a DC barrel type coaxial power connector. Acceptable AC input is 100-240VAC / ±10 %; 50-60Hz. Typical output voltage of the external brick AC power supply to the BV10-100/1000 is 9V DC. As soon as the BV10-100/1000 is connected to a live power supply, the POWER turns on. (If the POWER does not turn on, there is a power failure at the source or the unit is damaged.) The STATUS indicates whether or not the unit is ready for use. If the STATUS is not on, the unit is booting up. If it is green, red, or orange, the unit has booted. Grounding the BV10-100/1000 The BV10-100/1000 is shipped with a ground lug and hardware attached to the back of the unit. The grounding hardware consists of a washer with external teeth facing the unit and a locking nut. You will need to supply a #6 AWG wire. WARNING The BV10-100/1000 DC version is intended to be grounded. Ensure that the unit is connected to earth ground during normal use.
Installation Instructions for the BV10-100/1000 5 Ground lug AC unit Ground lug and hardware Ground lug DC unit Ground lug and hardware How to ground the BV10-100/1000 To ground the BV10-100/1000: 1 Loosen the locking nut on the grounding lug. 2 Using a #6 AWG wire, twist the wire around the lug so that it is touching the flat surface of the washer. The wire must be twisted between the washer and the locking nut. 3 Tighten the locking nut. 4 Connect the other end of the wire to the ground distribution network. Connecting the BV10-100/1000 to an AC Power Source This section explains how to connect power to a BV10-100/1000 equipped with AC power. How to connect an AC unit To connect the BV10-100/1000 to an AC power source: 1 Connect the supplied AC power cord to the BV10-100/1000 side panel through an IEC C14 connector. 2 Connect the other end of the power supply to the DC barrel-type coaxial power connector on the BV10-100/1000.
6 Installation Instructions for the BV10-100/1000 Connecting the BV10-100/1000 to a DC Power Source This section explains how to connect power to a BV10-100/1000 equipped with DC power. The unit is equipped with either +24V DC or -48V DC. WARNING Powering a BV10-100/1000 +24V DC unit with a -48V power source will permanently damage the unit. The +24V input range is 20-32V. WARNING Powering a BV10-100/1000-48V DC unit with a +24V power source will permanently damage the unit. The -48V input range is 40-72V. How to connect a DC unit To connect the BV10-100/1000 to a DC power source: 1 Using 14-16 AWG copper insulated wires and the supplied connector, insert the two stripped wires into the connector and tighten the screws firmly. Be sure to respect the polarity. The positive supply wire lead (40-72V for a -48V unit or 20-32V for a +24V unit) must be on the right side of the lug and the negative supply wire on the left side. The following figures show the -48V and +24V DC units. -48V DC Unit: Supplied connector Negative (-) supply wire lead on the left Positive (+) supply wire lead on the right
Installation Instructions for the BV10-100/1000 7 +24V DC Unit: Supplied connector Negative (-) supply wire lead on the left Positive (+) supply wire lead on the right 2 Connect the plug to one of the two DC input connectors on the BV10-100/1000 unit and tighten the screws firmly. 3 Connect the other end of the wires to the DC power source. CAUTION The DC input feeds to the equipment must be protected by 20A rated maximum breaker provided as part of the building installation. 4 To add a redundant DC power source on the BV10-100/1000, repeat step 1 through step 3.
8 Installation Instructions for the BV10-100/1000 Connecting the Test Interface Ports The BV10-100 provides an electrical 10/100Mbps Ethernet Test interface. The BV10-1000 provides an electrical 10/100/1000Mbps Ethernet Test interface and an optical SFP laser Ethernet Test interface. The two BV10-1000 Test interfaces are mutually exclusive. Management through the Test port The BV10-100/1000 can be managed in-band through the Test port. In-band management is provided for key tasks, such as basic configuration and software upgrades, in situations where the Management port is not accessible. It is important to note that in-band management through the Test port should be performed with low traffic volume so that management responses have minimal impact on test traffic. With high traffic volume, management responses might add jitter/latencey or dropped packets to results. The console in-band enable disable command controls in-band management on the Test port. By default, in-band management on the Test port is enabled. The following test activities are automatically disabled during software upgrade on the Test port: Smart Loopback TWAMP Light Responder UDP Echo Responder Ethernet OAM Handling State and configuration settings are preserved and restored when the software upgrade is complete and the BV10-100/1000 is rebooted.
Installation Instructions for the BV10-100/1000 9 Connecting the Electrical 10/100/1000Mbps Ethernet Test Interface BV10-100 The BV10-100/1000 has one electrical RJ-45 port for 10Base-T, 100Base-TX, and 1000Base-T testing capability. Note: 1000Base-T is available on the BV10-1000 only. Electrical 10/100Mbps BV10-1000 Electrical 10/100/1000Mbps How to connect the electrical test interface To use the 10/100/1000Mbps electrical interface for testing or management, connect the 10/100/1000Mbps electrical signal to the BV10-100/1000 10/100/1000Mbps port using a CAT 5 or better unshielded twisted pair (UTP) cable with an RJ-45 connector.
10 Installation Instructions for the BV10-100/1000 Connecting the Optical SFP 1000Mbps Ethernet Test Interfaces The BV10-1000 provides an optional optical port for 1000Base-SX/LX/ ZX testing capability. The optical port is a Small Form Factor Pluggable (SFP) slot type that uses an LC connector. CAUTION To ensure that the maximum receiver level is not exceeded, an attenuator might be needed. Optical SFP 1000Mps How to connect the optical test interface To use the 1000Mbps optical interface for testing or management: 1 Insert one of the following SFP modules into the optical slot. Rate 1000Base-X 850nm 1000Base-X 1300nm 1000Base-X 1550nm Description SFP module for 1000Base-SX short wavelength laser connection SFP module for 1000Base-LX long wavelength laser connection SFP module for 1000Base-ZX extended wavelength laser connection 2 Carefully connect the optical fiber cables to the SFP IN and OUT ports. To ensure good signal quality, make sure that the optical fiber connector is fully inserted into the optical connector port. Note: To ensure that the maximum receiver power level is not exceeded, an attenuator must be used.
Installation Instructions for the BV10-100/1000 11 Connecting the Management Interfaces You can connect the Management interface either locally using the Console port or remotely using the LAN port. Connecting the Console Port BV10-100 Console port Connecting a PC to the Console port, a standard RS-232 DE-9F DCE connection (commonly known as DB-9), provides local access to the BV10-100/1000 user interface. The connection configuration is 9600bps, 8 data bits, no parity, 1 stop bit (9600/8-N-1). The Console port is always enabled for CLI use. Console port BV10-1000 Console port Console port How to connect the Console port To connect locally to the BV10-100/1000 using the Console port, connect a PC to the Console port using an RS-232 straight cable with a DB-9 connector.
12 Installation Instructions for the BV10-100/1000 Connecting the Ethernet LAN Port BV10-100 LAN port Connecting a typical management network to the 10/100Mbps Ethernet LAN port provides remote access to the BV10-100/1000 command line interface (CLI). Either Telnet or SSH can be used and must be enabled. To connect to the LAN port using Telnet or SSH, the IP address must be known. The default address for the LAN port is IP address: 10.10.10.10 Netmask: 255.255.0.0 BV10-1000 LAN port 10/100Mbps Ethernet LAN port 10/100Mbps Ethernet LAN port How to connect the LAN port To connect remotely to the BV10-100/1000 using the LAN port, connect both the BV10-100/1000 LAN port and the remote PC to the same Management network using a standard straight through Ethernet cable with an RJ-45 connector.