IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Similar documents
IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI16, IO-DI16-L I/O Expansion Modules

Component identification

User safety and equipment protection guidelines

EX-RC1 Remote I/O Adapter

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

EX-RC1 Remote I/O Adapter

V E2B Snap-in I/O Module

EX-RC1 Remote I/O Adapter

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

V E1B Snap-in I/O Module

V E62B Snap-in I/O Module

V E5B Snap-in I/O Module

Micro-OPLC Installation Guide

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

High Speed Remote I/O Module

The identified danger could cause physical and property damage.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC V TR6/V350-J-TR6

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics controller model V T2.

V E4XB Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPLC Installation Guide

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E6B Snap-in I/O Module

Vision OPLC. V T38 Installation Guide. General Description

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

V E3XBW Snap-in I/O Module

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

V E3XB Snap-in I/O Module

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream HMI Panel. CPU-for-Panel

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

V TU24 V350-J-TU24

Vision OPLC V TR20

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC V TR20

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

UniStream CPU-for-Panel

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

V E3XB Snap-in I/O Module

High Speed Remote I/O Module

This guide provides basic information for Unitronics controllers V C30B and V T40B.

Vision OPLC V TR20/V350-J-TR20

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC. General Description.

Vision OPLC. General Description. Installation Guide V T34.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

FX1N-4EX-BD Input Expansion Board

FX1N-2EYT-BD Output Expansion Board

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Unitronics Devices and RS485 Table Of Contents

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Tempco Instruction Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Twido Programmable Controllers Discrete I/O Modules

FX1N JAPANESE SPECIFICATION UNITS

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PM Series Power Meter

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

FX2N-4AD-PT SPECIAL FUNCTION BLOCK

ACCESS 9340/9360 Meter Input/Output Module

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Speed monitor D / / 2014

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

SP6R Level Controller Operation Manual

Analog Voltage Combination Module

Conductive Level Controller

iologik 4000 Series (M) Modules

UniStream Uni-I/O Modules

Expansion Module HZS 541-1S

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Transcription:

IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs for temperature measurement. The interface between the module and the OPLC is provided by an adapter. The module may either be snap-mounted on a DIN rail, or screw-mounted onto a mounting plate. PT0 PT1 1 4 IO-PT4 5 PT OUT OF RANGE Component identification 1 Module-to-module connector 2 Status indicators 3 Input connection points, PT2 & PT3 4 Module-to-module connector port 5 Input connection points, PT0 & PT1 2 PT2 PT3 3 User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery, low voltage and EMC. Only a technician or engineer trained in the local and national electrical standards should perform tasks associated with the electrical wiring of this device. Under no circumstances will Unitronics be liable or responsible for any consequential damage that may arise as a result of installation or use of this equipment, and is not responsible for problems resulting from improper or irresponsible use of this device. All examples and diagrams shown in the manual are intended to aid understanding. They do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Only qualified service personnel should open this device or carry out repairs. Please dispose of this product in accordance with local and national standards and regulations. Check the user program before running it. Do not attempt to use this device with voltage exceeding permissible levels. Install an external circuit breaker and take appropriate safety measures against short-circuiting in external wiring. Failure to comply with appropriate safety guidelines can result in severe personal injury or property damage. Always exercise proper caution when working with electrical equipment. Unitronics Industrial Automation Systems 1

IO-PT4 I/O Expansion Module 11/00 Mounting the Module Mounting Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Provide proper ventilation by leaving a minimum space of 10mm between the top and bottom edges of the device and the enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. DIN-rail mounting Snap the device onto the DIN rail as shown below; the module will be squarely situated on the DIN rail. PT0 IO-PT4 + I +V -V -I PT1 PT OUT OF RANGE 93mm 3.5mm PT2 PT3 + I +V -V -I 44.5mm 14mm 60mm 80mm Screw-Mounting The figure on the next page is drawn to scale. It may be used as a guide for screw-mounting the module. Mounting screw type: either M3 or NC6-32. 2 Unitronics Industrial Automation Systems

11/00 IO-PT4 I/O Expansion Module 80mm 5.8mm 68.4mm 4mm 93mm 85mm 4mm (x2) Unitronics Industrial Automation Systems 3

IO-PT4 I/O Expansion Module 11/00 Connecting Expansion Modules An adapter provides the interface between the OPLC and an expansion module. To connect the I/O module to the adapter or to another module: 1 Push the module-to-module connector into the port located on the right side of the device. Note that there is a protective cap provided with the adapter. This cap covers the port of the final I/O module in the system. To avoid damaging the system, do not connect or disconnect the device when the power is on. Component identification 1 Module-to-module connector 2 Protective cap 1 2 Wiring Wire Size Use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ) for all wiring purposes. Wiring Considerations Do not use tin, solder or any other substance on the stripped wire that might cause the wire strand to break. We recommend that you use crimp terminals for wiring. Install at maximum distance from high-voltage cables and power equipment. General Wiring Procedures 1 Strip the wire to a length of 7±0.5mm (0.250 0.300 inches). 2 Unscrew the terminal to its widest position before inserting a wire. 3 Insert the wire completely into the terminal to ensure that a proper connection can be made. 4 Tighten enough to keep the wire from pulling free. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf m). Do not touch live wires. Double-check all the wiring before turning on the power supply. 4 Unitronics Industrial Automation Systems

11/00 IO-PT4 I/O Expansion Module Input Wiring Shields should be connected at the signal source. 2 wire connection PT100 3 wire connection PT100 PT0 + I +V -V -I PT1 IO-PT4 PT OUT OF RANGE PT2 PT3 PT100 4 wire connection Unitronics Industrial Automation Systems 5

IO-PT4 I/O Expansion Module 11/00 IO-PT4 Technical Specifications Max. current consumption Typical power consumption Status indicator (RUN) 35mA maximum from the adapter s 5VDC 0.09W @ 5VDC Green LED: Lit when a communication link is established between module and OPLC. Blinks when the communication link fails. Analog Inputs Number of inputs 4 Input type PT100 Input range -50 to 460 C Isolation None Resolution 12-bit (4096 units) Measurement resolution ±0.1 C. See Note 1. Conversion method Successive approximation Conversion time 40msec Input impedance 10MΩ minimum Auxiliary current for PT100 1.9mA Linearity error ±0.25 C (±0.05%) Temperature accuracy ±0.4 C Status indicators (OUT OF RANGE) Red LEDsLit when the corresponding input measures an analog value (temperature) outside of the permissible range. See Note 2. Connection options 2,3 or 4 wires Environmental IP20 Operating temperature 0 to 50 C Storage temperature -20 to 60 C Relative Humidity (RH) 5% to 95% (non-condensing) Dimensions (WxHxD) 80mm x 93mm x 60mm Weight 140.3g (4.94oz.) Mounting Either onto a 35mm DIN-rail or screw-mounted. Notes: 1. The input analog value represents the temperature value as follows: Analog value-262 Actual measured temperature: 26.2 C 2. The temperature values can also indicate certain faults as shown in the table below. Value Possible Cause -1000 C * Input temperature is out of the permissible range (under -50 C) * -I signal is not connected * Sensor is short-circuited 1000 C * Input temperature is out of the permissible range (over 460 C) * Sensor is not connected to input * +I or +V signals are not connected * -I and V signals are not connected 6 Unitronics Industrial Automation Systems

11/00 IO-PT4 I/O Expansion Module Addressing I/Os on M90 Expansion Modules Inputs and located on I/O expansion modules that are connected into an M90 OPLC are assigned addresses that comprise a letter and a number. The letter indicates whether the I/O is an input (I) or an output (O). The number indicates the I/O s location in the system. This number relates to both the position of the expansion module in the system, and to the position of the I/O on that module. Expansion modules are numbered from 0-7 as shown in the figure below. Adapter 0 1 2 3 4 5 6 7 Expansion module identification number The formula below is used to assign addresses for I/O modules used in conjunction with the M90 OPLC. X is the number representing a specific module s location (0-7). Y is the number of the input or output on that specific module (0-15). The number that represents the I/O s location is equal to: 32 + x 16 + y Examples Input #3, located on expansion module #2 in the system, will be addressed as I 67, 67 = 32 + 2 16 + 3 Output #4, located on expansion module #3 in the system, will be addressed as O 84, 84 = 32 + 3 16 + 4. EX90-DI8-RO8 is a stand-alone I/O module. Even if it is the only module in the configuration, the EX90-DI8- RO8 is always assigned the number 7. Its I/Os are addressed accordingly. Example Input #5, located on an EX90-DI8-RO8 connected to an M90 OPLC will be addressed as I 149, 149 = 32 + 7 16 + 5 Unitronics Industrial Automation Systems 7

8 Convenient I/O Modules Digital I/O (transistor) Digital I/O (relay) Analog I/O PT 100 IO-DI8-TO8 IO-DI16 IO-TO16 IO-DI8-RO4 IO-RO8 EX90-DI8-RO8* IO-AI4-AO2 I/O-PT4 Digital inputs (24VDC) 8 pnp/npn (source/sink) 16 pnp/npn (source/sink) 8 pnp/npn (source/sink) 8 pnp (source) Analog inputs 4 inputs 0-10V, 0-20mA, 4-20mA 4 PT100-50 to 460 C Analog input resolution 12 bit 12 bit Digital 8 pnp (source) 16 pnp (source) 4 relay 8 relay 8 relay Analog 2 ±10V, 0-20mA, 4-20mA Analog output resolution 12 bit + sign High-speed counter/ Frequency measurement One One One One * Stand-alone module. Other modules are used in conjunction with the EX-A1 adapter To order the expansion module that best fits your system, contact your local distributor. For a list of Unitronics distributors, check our website: http://www.unitronic.com/contact.htm