HP 5830 Switch Series. Installation Guide. Abstract

Similar documents
HP 5820X & 5800 Switch Series

HP 5500 HI Switch Series

HP 5500 HI Switch Series

HPE 5820X & 5800 Switch Series

HP A5120 EI & A5120 SI Switch Series. Installation Guide. Abstract

HPE PSR300-12A & PSR300-12D1

GVT QX-S6600 Series Ethernet Switches. Installation Guide

HP 527 Dual Radio ac Unified Wired-WLAN Walljack

HP 5500 EI & 5500 SI Switch Series

HP 1920 Gigabit Ethernet Switch Series

HP A10500 Switch Series. Installation Guide. Abstract

HP 10500/ G Unified Wired-WLAN Module

HP 6125 Blade Switch Series

HP A5120 EI Switch Series IRF. Command Reference. Abstract

H3C S5120-HI Switch Series

HPE FlexNetwork 5130 HI Switch Series

H3C S6520X-EI & S6520X-HI Switch Series

H3C Transceiver Modules and Network Cables

H3C S5560-EI Switch Series

HP 5820X & 5800 Switch Series IRF. Command Reference. Abstract

HPE FlexNetwork 5510 HI Switch Series

Managing Individual Components

H3C S5130S-EI Switch Series

Installing the Cisco SFS 3504 Server Switch

H3C S7508E-X Switch. Installation Guide. Hangzhou H3C Technologies Co., Ltd. Document version: 6PW

HP V1910 Switch Series

About the HP 830 Series PoE+ Unified Wired-WLAN Switch and HP 10500/ G Unified Wired-WLAN Module

Installing and Removing SDRAM and DRAM

H3C S12500 Routing Switch Series

Installing the Cisco Unified Videoconferencing 3545 MCU

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

About the Configuration Guides for HP Unified

HP 5920 & 5900 Switch Series

HP 5920 & 5900 Switch Series FAQ

SCSI Cable Installation Instructions

HP 5120 EI Switch Series

HP FlexFabric 5700 Switch Series

Maintaining E-Series Routers

Installing and Managing the Switch

HP High-End Firewalls

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Maintaining the ERX System

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Catalyst 6500 Series Wireless LAN Services Module Installation and Verification Note

Maintaining the ERX System

Power Supply and Fan Module Installation

Upgrading and Servicing Guide

H3C MSR X1[10-X1] Gigabit Ethernet Integrated Service Gateway

Upgrading and Servicing Guide

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

H3C SR6604/SR6608 Routers

Installing Power Modules

Replacing the Battery HP t5730 and t5735 Thin Clients

Installing the MWAM CHAPTER

PIX 520. PIX 520 Product Overview CHAPTER

HP 5920 & 5900 Switch Series

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

TRC-190 User s Manual

Installing the Cisco MDS 9020 Fabric Switch

Installation Manual. Table of Contents

hp uninterruptible power system r12000 xr models installation instructions

TRC-190 User s Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

HP A-F1000-A-EI/A-F1000-S-EI VPN Firewall

HP MSR93X Routers. Installation Guide. Part number: Document version: 6W

HP MSR Router Series. IPX Configuration Guide(V5) Part number: Software version: CMW520-R2513 Document version: 6PW

MX Voice Gateway Series. Installation Manual

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

Installation and Maintenance

Table of Contents Chapter 3 Installing the Switch

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Hardware Guide. EPIC Next Generation Firewall. USG6000 Unified Security Gateway V100R001. Give us a call:

HP 5920 & 5900 Switch Series

HP CX4 & XFP Interface Cards User Guide

Connect Router to the Network

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Upgrading and Servicing Guide

Installing a Network Module

HP FlexFabric 5700 Switch Series

Replacing the Power Supply

Installing and Upgrading Memory and Virtual Private Network Modules

Maintaining the Cisco Internet Router

HPE FlexNetwork 5510 HI Switch Series FAQ

Installation Job Aid for Avaya Virtual Services Platform 8400

Upgrading and Servicing Guide

Installing a Network Module

Upgrading and Servicing Guide

Quick Installation Guide 4 Slot Chassis-Based Switch

Upgrading and Servicing Guide

Installing the IPS 4345 and IPS 4360

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Replacing Cisco ASR 9000 Series Router Components

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

SCv3000 and SCv3020 Storage System. Owner s Manual

Preparing to Install the Cisco AS5350XM Universal Gateway

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Transcription:

HP 5830 Switch Series Installation Guide Abstract This document guides you through installation of HP A Series products, including installing the device, connecting to the network, hardware management, and troubleshooting. Part number: 5998-2058 Version 3 Document version: 6W100-20110720

Legal and notice information Copyright 2011 Hewlett-Packard Development Company, L.P. No part of this documentation may be reproduced or transmitted in any form or by any means without prior written consent of Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Contents Preparing for installation 1 Overview 1 Safety recommendations 1 Installation site requirements 2 Rack-mounting requirements 2 Installation tools 2 Installing the switch 3 Confirming installation preparations 4 Installing the switch in a 19-inch rack 4 Mounting bracket and cable management bracket kits 4 Rack mounting rail kit 5 Rack-mounting procedure 6 Identifying the mounting position 6 Installing the mounting brackets, chassis rails, and grounding cable (for the 48G model/48g TAA model) 7 Installing the mounting brackets, chassis rails, and grounding cable (for the 96G model/96g TAA model) 9 Rack-mounting the 48G model/48g TAA model switch 11 Rack-mounting the 96G model/96g TAA model switch 13 Grounding the switch 15 Grounding the switch with a grounding strip 16 Grounding an AC-powered switch through the PE wire 16 Installing/removing a fan tray 17 Selecting a fan tray 17 Installing a fan tray 18 Removing a fan tray 18 Installing/removing a power supply 19 Installing a power supply 19 Removing a power supply 20 Connecting the power cord 22 Connecting the 650W AC power supply (JC680A) 22 Connecting the 650W DC power supply (JC681A) 23 Installing/removing an interface card 23 Installing an interface card 23 Removing an interface card 24 Verifying the installation 25 Powering on the switch for the first time 26 Setting up the configuration environment 26 Connecting the console cable 26 Console cable 26 Connection procedure 26 Setting terminal parameters 27 Powering on the switch 30 Verification before power-on 30 Powering on the switch 30 Setting up an IRF fabric 32 IRF fabric setup flowchart 32 iii

Planning IRF fabric setup 33 Identifying the master switch and planning IRF member IDs 33 Planning IRF topology and connections 34 Identifying physical IRF ports on the member switches 35 Planning the cabling scheme 35 Configuring basic IRF settings 37 Connecting the physical IRF ports 37 Accessing the IRF fabric to verify the configuration 37 Maintenance and troubleshooting 39 Power supply failure 39 Fan failure 39 Configuration terminal problems 39 Support and other resources 41 Contacting HP 41 Subscription service 41 Related information 41 Documents 41 Websites 41 Conventions 42 Appendix A Technical specifications 44 Technical specifications 44 Panel views 45 48G model/48g TAA model panel views 45 96G model/96g TAA model panel views 46 Cooling system 47 Cooling system of the 48G model/48g TAA model 47 Cooling system of the 96G model/96g TAA model 49 Appendix B FRUs and compatibility matrixes 50 Hardware compatibility matrix 50 Hot swappable power supplies 50 Hot swappable fan trays 51 Interface cards 52 Appendix C Ports and LEDs 53 Ports 53 Console port 53 Management Ethernet port 53 10/100/1000Base-T Ethernet port 53 SFP port 54 SFP+ port 56 LEDs 58 System status LED 58 10/100/1000Base-T Ethernet port LED 58 SFP port LED 58 SFP+ port LED 59 Management Ethernet port LEDs 59 Interface card status LED 59 Index 60 iv

Preparing for installation Overview The HP 5830 Switch Series includes the models in Table 1: Table 1 Models in the HP 5830 Switch Series Product code HP description RMN Alias JC691A 48G Model Switch with 1 Interface Slot BJNGA-AC0001 5830AF-48G JG316A 48G TAA-compliant Model Switch with 1 Interface Slot BJNGA-AC0001 5830AF-48G TAA JC694A 96G Model Switch BJNGA-AC0002 5830AF-96G JG374A 96G TAA-compliant Model Switch BJNGA-AC0002 5830AF-96G TAA IMPORTANT: For regulatory identification purposes, the switches are assigned RMN. These regulatory numbers should not be confused with the marketing name HP 5830AF, or the product numbers JC691A, JG316A, JC694A, and JG374A. Safety recommendations WARNING! Read all of the safety instructions in the Compliance and Safety Guide supplied with your device before installation and operation. This section provides general recommendations. For more information see the Compliance and Safety Guide included with your device. Turn off all the power and remove all the power cables before opening the chassis. Unplug all power and external cables before moving the chassis. Locate the emergency power off switch before installation and shut off power immediately if necessary. Always wear an ESD-preventive wrist strap when installing the device. Do not stare into the open optical interface; the high power density light can burn the retina. Use a good grounding system to protect your device against lightning shocks, interferences, and ESD; this is essential to the operating reliability of your switch. Make sure the resistance between the chassis and the ground is less than 1 ohm. 1

Installation site requirements This section provides information about temperature and humidity, cleanness, and air quality requirements. You must maintain a proper temperature and humidity in the equipment room. Long-term high humidity may lead to bad insulation, electricity leakage, mechanical property changes, and metal corrosion. However, if the relative humidity is too low, captive screws may become loose as the result of contraction of insulation washers and static electricity may be produced in a dry environment to jeopardize the circuits. High temperature is the most undesirable condition, because it accelerates the aging of insulation materials and significantly lowers the reliability and service life of the switch. For the temperature and humidity requirements of different switch models, see Table 9 in Appendix A Technical specifications. Table 2 Dust concentration limit in the equipment room Substance Concentration limit (particles/m 3 ) Dust particles 3 x 104 (No visible dust on desk in three days) NOTE: Dust particle diameter 5 μm Table 3 Limits on harmful gases in the equipment room Gas Maximum concentration (mg/m 3 ) SO 2 0.2 H 2 S 0.06 NH 3 0.05 Cl 2 0.01 Rack-mounting requirements Before rack-mounting a switch, make sure the rack meets the following requirements: HP recommends that you mount a switch in an open rack. If you mount a switch in a closed rack, make sure there is a good heat dissipation system. Make sure the rack is steady enough to support the switch and accessories. Make sure the switch fits the rack size. Leave some spaces beside the left and right panels of the switch for chassis heat dissipation. Installation tools Phillips screwdriver P1-100mm, P2-150mm, and P3-250mm ESD-preventive wrist strap All these installation tools are user supplied. 2

Installing the switch CAUTION: Keep the tamper-proof seal on a mounting screw on the chassis cover intact. If you want to open the chassis, contact HP for permission. Otherwise HP shall not be liable for any consequence. Figure 1 Hardware installation flow Start Install to a specified position Ground the switch Install a fan tray Install a power module Connect the power cord Verify the installation Power on the switch Troubleshoot the switch Operating properly? Yes No Power off the switch No Install an interface card? Yes Verify the installation Operating properly? End Yes No Troubleshoot the switch 3

NOTE: When you install a 96G model or 96G TAA model switch, skip the procedure for installing an expansion interface card. The switch does not support expansion interface cards. Confirming installation preparations Before you install the switch, make sure: You have read "Preparing for installation" carefully and the installation site meets all the requirements. A 19-inch rack is ready for use. For how to install a rack, see the rack installation guide. Installing the switch in a 19-inch rack Mounting bracket and cable management bracket kits Table 4 Mounting bracket and cable management bracket kits Switch models Mounting brackets Cable management brackets Bracket view 48G model/48g TAA model One pair of 1U mounting brackets (supplied with the switch) N/A See Figure 2. 96G model/96g TAA model One pair of 2U mounting brackets (supplied with the switch) One pair (supplied with the switch) The mounting brackets and cable management brackets are secured together by default (see Figure 3). Figure 2 1U mounting bracket kit 4

Figure 3 2U cable management bracket and mounting bracket kit (1) Cable management bracket (2) Mounting bracket Rack mounting rail kit The switches come with a pair of chassis rails and a pair of slide rails. Figure 4 Chassis rail and slide rail kit for the 48G model/48g TAA model (1) Chassis rail (2) Slide rail The slide rails supplied with a 48G model or 48G TAA model switch are short. You can order a pair of long slide rails depending on your rack depth. For more information, see Table 6. 5

Figure 5 Chassis rail and slide rail kit for the 96G model/96g TAA model (1) Chassis rail (2) Slide rail Rack-mounting procedure You can install a switch in a 19-inch rack using different mounting positions. Figure 6 shows the rackmounting procedure. Figure 6 Rack-mounting procedure NOTE: If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate location, and fix the switch to the rack with the mounting brackets. Identifying the mounting position Table 5 Mounting positions Mounting bracket position Rear mounting (near the power supplies) Front mounting (near the network ports) Installing the mounting brackets, chassis rails, and grounding cable See "Installing the mounting brackets, chassis rails, and grounding cable (for the 48G model/48g TAA model)." See "Installing the mounting brackets, chassis rails, and grounding cable (for the 96G model/96g TAA model)." Installing the switch See "Rack-mounting the 48G model/48g TAA model switch." See "Rack-mounting the 96G model/96g TAA model switch." To mount the switch securely in a rack, use slide rails and chassis rails in addition to the mounting brackets. 6

Table 6 Minimum and maximum distances required between front and rear rack posts Switch model 48G model/48g TAA model 96G model/96g TAA model Mounting accessories Mounting brackets and short slide rails (supplied with the switch) Mounting brackets and long slide rails (optional) Mounting brackets and slide rails (supplied with the switch) Minimum distance between front and rear rack posts Maximum distance between front and rear rack posts 401 mm (15.79 in) 654 mm (25.75 in) 621 mm (24.45 in) 874 mm (34.41 in) 489 mm (19.25 in) 993 mm (39.09 in) Installing the mounting brackets, chassis rails, and grounding cable (for the 48G model/48g TAA model) Each of the 48G model and 48G TAA model switches has one front mounting position near the network ports and one rear mounting position near the power supplies. The switch also has one primary grounding point with a grounding sign and one auxiliary grounding point. Use the primary grounding point in most situations. If the primary grounding point fails or is not suitable for the installation site, use the auxiliary grounding point. Figure 7 Identifying the mounting and grounding positions 7 1 2 3 4 (1) Rear mounting position (2) Primary grounding point (3) Auxiliary grounding point (4) Front mounting position Attaching the mounting brackets and chassis rails to the switch chassis Use the following procedure for both sides of the chassis. To attach the mounting brackets and chassis rails to the switch chassis: 1. Align the mounting brackets with the screw holes in the rear mounting position (see Figure 8) or front mounting position (see Figure 9). 2. Use M4 screws supplied with the switch to fix the mounting brackets to the chassis.

3. If the mounting brackets are in the rear mounting position, align the chassis rails with the screw holes at the front of the side panels (see Figure 8). If the mounting brackets are in the front mounting position, align the chassis rails with the screw holes at the rear of the side panels (see Figure 9). 4. Use M4 screws (supplied with the switch) to fix the chassis rails to the chassis. Connecting the grounding cable to the switch chassis CAUTION: The primary grounding point and auxiliary grounding point are located on the left side panel. If you use either of the grounding points, you must connect the grounding cable to the grounding point before you mount the switch in the rack. To connect the grounding cable to a chassis grounding point: 1. Select a grounding point, for example, the primary grounding point. 2. Remove the grounding screws from the primary grounding point. (You can use the screws for connecting to the primary grounding point or the auxiliary grounding point.) 3. Align the two-hole grounding lug at one end of the cable with the grounding holes of the grounding point, insert the grounding screws into the holes, and tighten the screws with a screwdriver to fix the grounding lug to the chassis, as shown in Figure 8. Figure 8 Attaching the rear mounting brackets, chassis rails, and the grounding cable to the chassis 8

Figure 9 Attaching the front mounting brackets and the chassis rails to the chassis Installing the mounting brackets, chassis rails, and grounding cable (for the 96G model/96g TAA model) Each of the 96G model and 96G TAA model switches has one front mounting position near the network ports and one rear mounting position near the power supplies. The switch also has one primary grounding point with a grounding sign and one auxiliary grounding point. You use the primary grounding point in most situations. If the primary grounding point fails or is not suitable for the installation site, use the auxiliary grounding point. Figure 10 Identifying the mounting and grounding positions 1 2 3 4 (1) Rear mounting position (2) Primary grounding point (3) Auxiliary grounding point (4) Front mounting position Attaching the mounting brackets and chassis rails to the switch chassis Use the following procedure for both sides of the chassis. To attach the mounting brackets and chassis rails to the switch chassis: 1. Align the mounting brackets with the screw holes in the rear mounting position (see Figure 11) or front mounting position (see Figure 12). 9

2. Use M4 screws supplied with the switch to fix the mounting brackets to the chassis. 3. Align the chassis rails with the screw holes at the side panels (see Figure 11 and Figure 12). 4. Use M4 screws supplied with the switch to fix the chassis rails to the chassis. Connecting the grounding cable to the switch chassis CAUTION: The primary grounding point and auxiliary grounding point are located on the left side panel. If you use either of the grounding points, you must connect the grounding cable to the grounding point before you mount the switch in the rack. To connect the grounding cable to a chassis grounding point: 1. Choose a grounding point, for example, the primary grounding point. 2. Unpack the grounding cable and the grounding screws. (You can use the cable and screws for connecting to the primary grounding point or the auxiliary grounding point.) 3. Align the two-hole grounding lug at one end of the cable with the grounding holes of the grounding point, insert the grounding screws into the holes, and tighten the screws with a screwdriver to fix the grounding lug to the chassis, as shown in Figure 11. Figure 11 Attaching the rear mounting brackets, chassis rails, and the grounding cable to the chassis 10

Figure 12 Attaching the front mounting brackets and the chassis rails to the chassis Rack-mounting the 48G model/48g TAA model switch To attach the slide rails to the rack: 1. Identify the rack attachment position for the slide rails. 2. Install cage nuts (user-supplied) in the mounting holes in the rack posts. 3. Align the screw holes in one slide rail with the cage nuts in the rack post on one side, and use screws (user-supplied) to fix the slide rail to the rack, as shown in Figure 13. 4. Repeat the preceding step to attach the other slide rail to the rack post on the other side. Keep the two slide rails at the same height so the slide rails can fit into the chassis rails. Figure 13 Installing the slide rails Mounting the switch on the rack requires two persons. To mount the switch in the rack: 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 11

2. Verify that the mounting brackets and chassis rails have been securely fixed on the two sides of the switch. 3. Verify that the slide rails have been correctly attached to the rack posts. 4. Install cage nuts (user-supplied) to the front rack posts and make sure they are at the same level as the slide rails. 5. Supporting the bottom of the switch, align the chassis rails with the slide rails on the rack posts, as shown in Figure 14. Work with another person to slide the chassis rails along the slide rails until the mounting brackets flush with the rack posts. 6. Use appropriate screws to fix the mounting brackets to the rack, as shown in Figure 15. Make sure the front ends of the slide rails reach out of the chassis rails, as shown in callout 1 in Figure 15. Figure 14 Mounting the switch in the rack (I) 12

Figure 15 Mounting the switch in the rack (II) Rack-mounting the 96G model/96g TAA model switch To attach the slide rails to the rack: 1. Identify the rack attachment position for the slide rails. 2. Install cage nuts (user-supplied) in the mounting holes in the rack posts. 3. Align the screw holes in one slide rail with the cage nuts in the rack post on one side, and use screws (user-supplied) to fix the slide rail to the rack, as shown in Figure 16. 4. Repeat the preceding steps to attach the other slide rail to the rack post on the other side. Keep the two slide rails at the same height so the slide rails can fix into the chassis rails. 13

Figure 16 Installing the slide rails Mounting the switch to the rack requires two persons. To mount the switch to the rack: 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Verify that the mounting brackets and chassis rails have been securely fixed on the two sides of the switch. 3. Verify that the slide rails have been correctly attached to the rack posts. 4. Install cage nuts (user-supplied) to the front rack posts and make sure they are at the same level as the slide rails. 5. Supporting the bottom of the switch, align the chassis rails with the slide rails on the rack posts, as shown in Figure 17. Work with another person to slide the chassis rails along the slide rails until the mounting brackets flush with the rack posts. 6. Use appropriate screws to fix the mounting brackets to the rack, as shown in Figure 18. To ensure steadiness of the switch in the rack, make sure the front ends of the slide rails reach out of the chassis rails, as shown in callout 1 in Figure 18. 14

Figure 17 Mounting the switch in the rack (I) Figure 18 Mounting the switch in the rack (II) Grounding the switch WARNING! Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection. 15

The power input end of the switch has a noise filter, whose central ground is directly connected to the chassis to form the chassis ground (commonly known as PGND). You must securely connect this chassis ground to the earth so the faradism and leakage electricity can be safely released to the earth to minimize EMI susceptibility of the switch. You can ground the switch using one of the following methods, depending on the grounding conditions available at the installation site: Grounding the switch with a grounding strip Grounding an AC-powered switch through the PE wire The power and grounding terminals in this section are for illustration only. Grounding the switch with a grounding strip 1. Attach the two-hole grounding lug at one end of the grounding cable to a grounding point on the switch chassis. 48G model and 48G TAA model: see "Connecting the grounding cable to the switch chassis." 96G model and 96G TAA model: See "Connecting the grounding cable to the switch chassis." 2. Connect the OT terminal at the other end of the grounding cable to a grounding post on the grounding strip, and fasten the grounding cable to the grounding post with a hex nut. Figure 19 Connecting the grounding cable to a grounding strip 1 2 3 4 (1) Hex nut (2) OT terminal (3) Grounding post (4) Grounding strip Grounding an AC-powered switch through the PE wire If you ground an AC-powered switch through the PE wire of the power cable, make sure the following conditions are met: The power cable is a three-wire power cable that has a PE terminal. The ground contact in the power outlet is securely connected to the ground in the power distribution room or on the AC transformer side. 16

The power cable is securely connected to the power outlet. Figure 20 Grounding through the PE wire of an AC power cable Installing/removing a fan tray CAUTION: The switches have only one fan tray slot. To ensure good ventilation, make sure these conditions are met: Do not operate the switch without a fan tray. If the JC692A or JC693A fan tray has problems during operation, replace it within 8 minutes while the switch is operating. If the JC695A or JC696A fan tray has problems during operation, replace it within 6 minutes while the switch is operating. If you fail to replace the fan tray within the time limit, the switch generates alarms, the system LED flashes red, and the switch might be damaged. Selecting a fan tray The switches provide two types of fan trays with different airflow directions: from power side to port side and from port side to power side. Before you install a fan tray, check the airflow direction labeled on the fan tray and make sure the airflow of the chassis is appropriate to the installation site. When the switch is started up, the system records the airflow direction of the fan tray. After you replace the fan tray when the switch is operating, if the airflow direction of the new fan tray is not the same as the old one, the system displays the following trap and log information: System fan airflow direction is not preferred on slot x, please check it. If you confirm that the airflow direction of the new fan tray is correct, use the fan prefer-direction slot slot-number { power-to-port port-to-power } command in system view to change the preferred airflow direction. For more information about the cooling system and fan tray specifications of the switch, see "Cooling system" and "Table 13." For more information about the fan prefer-direction slot command, see HP 5830 Switch Series Fundamentals Command Reference. 17

Installing a fan tray 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Loosen the captive screws on the filler panel to remove the filler panel. 3. Unpack the fan tray and check that the fan tray model is correct. 4. Grasp the handle of the fan tray with one hand and support the fan tray bottom with the other, and slide the fan tray along the guide rails into the slot until the fan tray seats in the slot and has a firm contact with the backplane (see callout 1 in Figure 21 or Figure 22). To prevent damage to the fan tray or the connectors on the backplane, insert the fan tray gently. If you encounter resistance while inserting the fan tray, pull out the fan tray and insert it again. 5. Fasten the captive screw on the fan tray with a Philips screwdriver until the fan tray is securely fastened into the chassis (see callout 2 in Figure 21 or Figure 22). If the captive screw cannot be tightly secured, check the installation of the fan tray. Figure 21 Installing a fan tray (for the 48G model/48g TAA model) Figure 22 Installing a fan tray (for the 96G model/96g TAA model) Removing a fan tray 18

WARNING! Take out the fan tray after the fans completely stop rotating. To avoid an unbalanced fan causing loud noise, do not touch the fans, even if they are not rotating. To remove a fan tray: 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Loosen the captive screw of the fan tray with a Philips screwdriver until it is fully disengaged from the switch chassis. 3. Grasp the handle of the fan tray with one hand and pull the fan tray part way out the slot. Support the fan tray bottom with the other hand, and pull the fan tray slowly along the guide rails out of the slot. Put the removed fan tray in an antistatic bag for future use. Installing/removing a power supply The switches come with both power supply slots covered by filler modules. You can install one or two power supplies as needed. For more information about the power supplies available for the switches, see "Appendix B FRUs and compatibility matrixes." Installing a power supply 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Remove the power filler module from the power supply slot. 3. Unpack the power supply and check that the power supply model is correct. 4. Correctly orient the power supply with the power supply slot (see Figure 23 and Figure 24), grasp the handle of the module with one hand and support the module bottom with the other, and slide the module slowly along the guide rails into the slot. Follow the forward inertia of the power supply when inserting it into the chassis to ensure that the power supply has firm contact with the connectors on the backplane. 5. To prevent damage to the connectors inside the switch chassis, insert the power supply gently. If you encounter resistance while inserting the power supply, pull out the power supply and insert it again. If you cannot insert the power supply into the slot, re-orient the power supply rather than use excessive force to push it in. Figure 23 Installing a power supply (for the 48G model/48g TAA model) 19

Figure 24 Installing a power supply (for the 96G model/96g TAA model) Removing a power supply CAUTION: If the switch has two power supplies, removing one power supply does not affect the operation of the switch. If the switch has only one power supply, removing the power supply powers off the switch. To remove a power supply: 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Remove the power cord from the power supply. If the power supply is AC powered, directly unplug the power cord. If the power supply is DC powered, squeeze the tabs on the power cord connector with your thumb and forefinger and pull the connector out, as shown in Figure 25. 3. Hold the handle on the power supply with one hand, pivot the latch on the power supply with your thumb, and pull the power supply part way out of the slot, as shown in Figure 26 and Figure 27. 4. Supporting the power supply bottom with one hand, slowly pull the power supply out with the other hand. Put the removed power supply in an antistatic bag for future use. 5. If no power supply is to be installed, install the power filler module. 20

Figure 25 Removing the DC power cord (1) Press the tabs on the power cord connector with your thumb and forefinger (2) Pull the power cord connector out Figure 26 Removing the power supply (for the 48G model/48g TAA model) (1) Pivot the latch to the right with your thumb (2) Pull the power supply out 21

Figure 27 Removing the power supply (for the 96G model/96g TAA model) (1) Pivot the latch up with your thumb (2) Pull the power supply out Connecting the power cord Connecting the 650W AC power supply (JC680A) 1. Insert the female connector of the AC power cord supplied with the power supply into the ACinput power receptacle of the power supply. 2. Use a cable tie to secure the power cord to the handle of the power supply, as shown in Figure 28. 3. Connect the other end of the power cord to an AC power outlet. Figure 28 Connecting the 650W AC power supply (JC680A) (1) Cable tie (2) Tighten the cable tie to secure the power cord to the handle of the power supply 22

Connecting the 650W DC power supply (JC681A) 1. Unpack the DC power cord, identify the plug for connecting to the power supply, orient the plug with the power receptacle on the power supply, and insert the plug into the receptacle (see Figure 29). If you cannot insert the plug into the receptacle, re-orient the plug rather than use excessive force to push it in. 2. Use a cable tie to secure the power cord to the handle of the power supply, as shown in Figure 28. 3. Connect the other end of the power cord to the DC power source. Figure 29 Connecting the 650W DC power supply (JC681A) Installing/removing an interface card CAUTION: Do not touch the surface-mounted components directly with your hands. Do not use excessive force during the operation. Each of the 48G model and 48G TAA model switches provides an expansion interface slot covered with a filler panel. For the interface cards available for the switches, see "Appendix B FRUs and compatibility matrixes." Installing an interface card 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Loosen the mounting screws on the filler panel over the interface card slot at the front panel with a Phillips screwdriver and remove the filler panel. Keep the removed filler panel for future use. 23

Figure 30 Removing the filler panel over an interface card slot 3. Unpack the interface card. Gently push the interface card in along the slot guide rails until the interface card has close contact with the switch. 4. Tighten the captive screws with a Phillips screwdriver to fix the interface card. Figure 31 Installing an interface card (1) Slide the interface card into the slot (2) Tighten the captive screws Removing an interface card 1. Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well grounded. 2. Use a Phillips screwdriver to loosen the captive screws at both sides of the interface card completely. 3. Pull the interface card along the guide rails until it completely comes out of the switch chassis. 4. If no new card is to be installed, install the filler panel to prevent dust and ensure good ventilation in the switch. Figure 32 Remove an interface card 1 1 2 (1) Loosen the captive screws (2) Pull the interface card out of the slot 24

Verifying the installation Before you power on the switch, verify the following items are in place: There is enough space for heat dissipation around the switch, and the rack is stable. The grounding cable is securely connected. The correct power source is used. The power cords are properly connected. 25

Powering on the switch for the first time Setting up the configuration environment To set up the configuration environment, connect a terminal (a PC in this example) to the console port on the switch with a console cable. Figure 33 Network diagram for configuration environment setup Connecting the console cable Console cable A console cable is an 8-core shielded cable, with a crimped RJ-45 connector at one end for connecting to the console port of the switch, and a DB-9 female connector at the other end for connecting to the serial port on the console terminal. Figure 34 Console cable Connection procedure To connect a terminal device to the switch: 1. Identify the mark on the console port and make sure you are connecting to the correct port. 26

2. Plug the DB-9 female connector of the console cable to the serial port of the console terminal or PC. 3. Connect the RJ-45 connector to the console port of the switch. NOTE: The serial port on a PC does not support hot swapping. When you connect a PC to a powered-on switch, connect the DB-9 connector of the console cable to the PC before connecting the RJ-45 connector to the switch. When you disconnect a PC from a powered-on switch, disconnect the DB-9 connector of the console cable from the PC after disconnecting the RJ-45 connector from the switch. Setting terminal parameters To configure and manage the switch, you must run a terminal emulator program on the console terminal, for example, a PC. This section uses Windows XP HyperTerminal as an example. The following are the required terminal settings: Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None Emulation VT100 To set terminal parameters, for example, on a Windows XP HyperTerminal: 1. Select Start > All Programs > Accessories > Communications > HyperTerminal. The Connection Description dialog box appears. 2. Enter the name of the new connection in the Name field and click OK. Figure 35 Connection description 27

3. Select the serial port to be used from the Connect using list, and click OK. Figure 36 Setting the serial port used by the HyperTerminal connection 4. Set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None, and click OK. Figure 37 Setting the serial port parameters 5. Select File > Properties in the HyperTerminal window. 28

Figure 38 HyperTerminal window 6. On the Settings tab, set the emulation to VT100, and click OK. Figure 39 Setting terminal emulation in Switch Properties dialog box 29

Powering on the switch Verification before power-on Before powering on the switch, verify that: The power cord is properly connected. The input power voltage meets the requirement of the switch. The console cable is properly connected, the terminal or PC used for configuration has started, and the configuration parameters have been set. Powering on the switch Power on the switch (for example, an 5830AF-48G switch), and you can see the following information: System is starting... Booting Normal Extend BootWare... The Extend BootWare is self-decompressing...done! **************************************************************************** * * * HP A5830AF BootWare, Version 1.03 * * * **************************************************************************** Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P. Compiled Date : Feb 22 2011 CPU Type : XLS208 CPU L1 Cache : 32KB CPU Clock Speed : 750MHz Memory Type : DDR2 SDRAM Memory Size : 1024MB Memory Speed : 533MHz BootWare Size : 1024KB Flash Size : 64MB CPLD Version : 002 PCB Version : Ver.B BootWare Validating... Press Ctrl+B to enter extended boot menu... Starting to get the main application file--flash:/main.bin!......... The main application file is self-decompressing............... 30

..............Done! The oam application file is self-decompressing............done! System application is starting... User interface aux0 is available. Press ENTER to get started. Press Enter at the prompt. When the prompt <HP> appears, you can configure the switch. For more information about the configuration commands and CLI, see HP 5830 Switch Series Configuration Guides and HP 5830 Switch Series Command References. 31

Setting up an IRF fabric You can use HP IRF technology to connect and virtualize the switches into a virtual switch called an "IRF fabric" or "IRF virtual device" for flattened network topology, and high availability, scalability, and manageability. IRF fabric setup flowchart Figure 40 IRF fabric setup flowchart Start Plan IRF fabric setup Install IRF member switches Connect the grounding cable and power cords Power on the switches Configure basic IRF settings Connect the physical IRF ports Slave switches reboot and the IRF fabric is automatically established End To set up an IRF fabric: 32

Step 1. Plan IRF fabric setup. 2. Install IRF member switches. 3. Connect ground wires and power cords. Description Plan the installation site and IRF fabric setup parameters. Complete the following tasks: Planning IRF fabric setup Identifying the master switch and planning IRF member IDs Planning IRF topology and connections Identifying physical IRF ports on the member switches Planning the cabling scheme See "Setting up an IRF fabric." See "Grounding the switch" and "Connecting the power cord." 4. Power on the switches. N/A. 5. Configure basic IRF settings. 6. Connect the physical IRF ports. See HP 5830 Switch Series IRF Configuration Guide. Connect the physical IRF ports on the switches. Use SFP+ transceiver modules and fibers to connect 10-Gigabit SFP+ ports over a long distance, or use SFP+ cables to connect 10-Gigabit SFP+ ports over a short distance. All switches except the master switch automatically reboot, and the IRF fabric is established. Planning IRF fabric setup To plan for IRF fabric size and the installation site, choose the switch models and identify the number of required IRF member switches, depending on the user density and upstream bandwidth requirements. The switching capacity of an IRF fabric equals the total switching capacities of all member switches. As your business grows, you can plug a switch into an IRF fabric to increase the switching capacity without any topology change or replacement. Plan the installation site depending on your network solution, as follows: Place all IRF member switches in one rack for centralized high-density access. Distribute the IRF member switches in different racks to implement the ToR access solution for a data center. Identifying the master switch and planning IRF member IDs Determine which switch you want to use as the master for managing all member switches in the IRF fabric. An IRF fabric has only one master switch. You configure and manage all member switches in the IRF fabric at the command line interface of the master switch. NOTE: IRF member switches will automatically elect a master. You can affect the election result by assigning a high member priority to the intended master switch. For more information about master election, see HP 5830 Switch Series IRF Configuration Guide. 33

Prepare an IRF member ID assignment scheme. An IRF fabric uses member IDs to uniquely identify and manage its members, and you must assign each IRF member switch a unique member ID. Planning IRF topology and connections You can create an IRF fabric in daisy chain topology, or more reliably, ring topology. In ring topology, the failure of one IRF link does not cause the IRF fabric to split as in daisy chain topology. Rather, the IRF fabric changes to a daisy chain topology without interrupting network services. You connect the IRF member switches through IRF ports, the logical interfaces for the connections between IRF member switches. Each IRF member switch has two IRF ports: IRF-port 1 and IRF-port 2. An IRF port goes up when you bind the first member physical port to it. When connecting IRF member switches, you must connect the physical ports of IRF-port 1 on one switch to the physical ports of IRF-port 2 on its neighbor switch. The switches can provide 10-GE IRF connections through SFP+ ports, and you can bind several SFP+ ports to an IRF port for increased bandwidth and availability. NOTE: Figure 41 and Figure 42 show the topologies for an IRF fabric made up of three 48G model switches for IRF connections. The IRF port connections in the two figures are for illustration only, and more connection methods are available. Figure 41 IRF fabric in daisy chain topology 34

Figure 42 IRF fabric in ring topology Identifying physical IRF ports on the member switches Identify the physical IRF ports on the member switches according to your topology and connection scheme. Table 7 shows the physical ports that can be used for IRF connection. Table 7 Physical IRF port requirements Switch chassis 48G model/48g TAA model 96G model/96g TAA model Candidate physical IRF ports 2 fixed SFP+ ports on the front panel 2 SFP+ ports on the 10 GE SFP+ expansion interface card at the rear panel NOTE: You must purchase the expansion interface card separately. 10 fixed SFP+ ports on the front panel Planning the cabling scheme Use SFP+ cables or SFP+ transceiver modules and fibers to connect the IRF member switches. If the IRF member switches are far away from one another, choose the SFP+ transceiver modules with optical fibers. If the IRF member switches are all in one equipment room, choose SFP+ cables. Table 20 and Table 21 list the SFP+ transceivers and SFP+ cables available for IRF connections. The following subsections describe several HP recommended IRF connection schemes. All these schemes use a ring topology. IMPORTANT: In these schemes, all physical IRF ports are located on the same side. If physical IRF ports are on different sides, you must measure the distance between them to select an appropriate cable. 35

Connecting the IRF member switches in one rack Use short-haul and long-haul SFP+ cables to connect the IRF member switches (four switches in this example) in a rack as shown in Figure 43. The switches in the ring topology (see Figure 44) are in the same order as connected in the rack. Figure 43 Connecting the switches in one rack Figure 44 IRF fabric topology Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a ToR solution. Figure 45 shows an example for connecting four top of rack IRF member switches by using SFP+ transceiver modules and optical fibers. The topology is the same as Figure 44. Figure 45 Connecting top of rack switches 36

Configuring basic IRF settings After you install the IRF member switches, power on the switches, and log in to each IRF member switch (see HP 5830 Switch Series Fundamentals Configuration Guide) to configure their member IDs, member priorities, and IRF port bindings. Follow these guidelines when you configure the switches: Assign the master switch higher member priority than any other switch. Bind physical ports to IRF port 1 on one switch and to IRF port 2 on the other switch. You perform IRF port binding before or after connecting IRF physical ports depending on the software release. To bind the ports on an interface card to an IRF port, you must install the interface card first. For how to install an interface card, see HP LSPM2SP2P Interface Card User Guide. Execute the display irf configuration command to verify the basic IRF settings. For more information about configuring basic IRF settings, see HP 5830 Switch Series IRF Configuration Guide. Connecting the physical IRF ports Use SFP+ cables or SFP+ transceiver modules and fibers to connect the IRF member switches as planned. NOTE: Wear an ESD-preventive wrist strap when you connect SFP+ cables or SFP+ transceiver modules and fibers. For how to connect them, see SFP/SFP+/XFP Transceiver Modules Installation Guide. Accessing the IRF fabric to verify the configuration To verify the basic functionality of the IRF fabric after you finish configuring basic IRF settings and connecting IRF port: 1. Log in to the IRF fabric through the console port of any member switch. 2. Create a Layer 3 interface, assign it an IP address, and make sure the IRF fabric and the remote network management station can reach each other. 3. Use Telnet, web, or SNMP to access the IRF fabric from the network management station. (See HP 5830 Switch Series Fundamentals Configuration Guide.) 4. Check that you can manage all member switches as if they were one node. 5. Display the running status of the IRF fabric by using the commands in Table 8. Table 8 Displaying and maintaining IRF configuration and running status Task Display information about the IRF fabric Display all members configurations Display topology information about the IRF fabric Command display irf display irf configuration display irf topology 37

NOTE: To avoid IP address collision and network problems, configure at least one MAD mechanism to detect the presence of multiple identical IRF fabrics and handle collisions. For more information about MAD detection, see HP 5830 Switch Series IRF Configuration Guide. 38

Maintenance and troubleshooting Power supply failure When a power supply is operating properly, its status LED is green. If not, follow these steps to troubleshoot the power supply: 1. Check for overheating. Overheating can cause a power supply to enter the protection state. Make sure the switch is well ventilated. 2. Check for loose power cord connection, and reconnect the power cord. If the power cord is broken, replace it. 3. Verify that the power supply is fully seated in the slot. 4. Verify that the power source is supplying power at the correct voltage. 5. If the other power supply slot is empty, plug the power supply into the empty slot to check for an operating anomaly. 6. Plug a new power supply of the same model into the same slot, and connect it to the same power input end. If the new power supply can work properly, the old power supply has failed. Contact HP technical support to replace the old power supply. Fan failure When a fan tray is working properly, its status LED is green. If the LED is red or off, verify the following items: 1. The switch and the power supplies are working properly. 2. The air intakes and exhaust vents of the chassis are not blocked. If the problem persists, contact HP for help. Configuration terminal problems If the configuration environment setup is correct, the configuration terminal displays boot information when the switch is powered on. If the setup is incorrect, the configuration terminal displays nothing or garbled text. No terminal display If the configuration terminal displays nothing when the switch is powered on, verify the following items: The power supply is supplying power to the switch. The console cable is properly connected. The console cable works properly and the terminal settings are correct. Garbled terminal display If terminal display is garbled, verify that the following settings are configured for the terminal: Baud rate 9,600 Data bits 8 39

Parity None Stop bits 1 Flow control None Emulation VT100 40

Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/wwalerts After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. Related information Documents Websites To find related documents, browse to the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For related documentation, navigate to the Networking section, and select a networking category. For a complete list of acronyms and their definitions, see HP A-Series Acronyms. HP.com http://www.hp.com HP Networking http://www.hp.com/go/networking HP manuals http://www.hp.com/support/manuals HP download drivers and software http://www.hp.com/support/downloads HP software depot http://www.software.hp.com 41

Conventions This section describes the conventions used in this documentation set. Command conventions Convention Boldface Italic Description Bold text represents commands and keywords that you enter literally as shown. Italic text represents arguments that you replace with actual values. [ ] Square brackets enclose syntax choices (keywords or arguments) that are optional. { x y... } [ x y... ] { x y... } * [ x y... ] * &<1-n> Braces enclose a set of required syntax choices separated by vertical bars, from which you select one. Square brackets enclose a set of optional syntax choices separated by vertical bars, from which you select one or none. Asterisk-marked braces enclose a set of required syntax choices separated by vertical bars, from which you select at least one. Asterisk-marked square brackets enclose optional syntax choices separated by vertical bars, from which you select one choice, multiple choices, or none. The argument or keyword and argument combination before the ampersand (&) sign can be entered 1 to n times. # A line that starts with a pound (#) sign is comments. GUI conventions Convention Boldface > Description Window names, button names, field names, and menu items are in bold text. For example, the New User window appears; click OK. Multi-level menus are separated by angle brackets. For example, File > Create > Folder. Symbols Convention WARNING CAUTION IMPORTANT NOTE TIP Description An alert that calls attention to important information that if not understood or followed can result in personal injury. An alert that calls attention to important information that if not understood or followed can result in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information. An alert that contains additional or supplementary information. An alert that provides helpful information. 42

Network topology icons Represents a generic network device, such as a router, switch, or firewall. Represents a routing-capable device, such as a router or Layer 3 switch. Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports Layer 2 forwarding and other Layer 2 features. Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device. 43