The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Similar documents
European Policies for Energy Efficiency in ICT Paolo Bertoldi European Commission DG JRC

EU Code of Conduct on Data Centre Energy Efficiency

EU Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.1.0

EU Code of Conduct on Data Centre Energy Efficiency. Participant Guidelines and Registration Form. Version 3.0.0

Code of Conduct on Data Centres Energy Efficiency. Registration Form for Endorsers

European Union Code of Conduct for Data Centres. Liam Newcombe BCS DCSG

European Code of Conduct on Data Centre Energy Efficiency

EUROPEAN DATA CENTRE STANDARDS

EN 50600, EU COC, EMAS AND EUROPEAN DATA CENTRE ENERGY EFFICIENCY MANAGEMENT

Trends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon

LOT 9 and MANDATE 462 DISCUSSION

INSPIRE status report

HPE Energy Efficiency Certification Service

DG CONNECT (Unit H5) Update on Data Centre Activities

2018 Best Practice Guidelines for the EU Code of Conduct on Data Centre Energy Efficiency

2017 Best Practice Guidelines for the EU Code of Conduct on Data Centre Energy Efficiency

NIS Directive : Call for Proposals

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

Intermediate Certificate in EU Code of Conduct for Data centres

PART IV GLOSSARY OF TERMS

Information sharing in the EU policy on NIS & CIIP. Andrea Servida European Commission DG INFSO-A3

Enforcing building codes for new and existing buildings. Dr. Zoran Morvaj

CEF e-invoicing. Presentation to the European Multi- Stakeholder Forum on e-invoicing. DIGIT Directorate-General for Informatics.

DATA CENTRE CODES AND STANDARDS

Guidelines 4/2018 on the accreditation of certification bodies under Article 43 of the General Data Protection Regulation (2016/679)

Global Specification Protocol for Organisations Certifying to an ISO Standard related to Market, Opinion and Social Research.

ENISA s Position on the NIS Directive

ARTICLE 29 DATA PROTECTION WORKING PARTY

ETSI GS OEU 006 V1.1.1 ( )

Copernicus Space Component. Technical Collaborative Arrangement. between ESA. and. Enterprise Estonia

Web-Accessibility as a human right

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

EP s approach to Power & Energy efficiency in DCs & paradigms

Directive on security of network and information systems (NIS): State of Play

COUNCIL OF THE EUROPEAN UNION. Brussels, 24 May /13. Interinstitutional File: 2013/0027 (COD)

Addressing Data Center Efficiency Lessons Learned From Process Evaluations of Utility Energy Efficiency Programs

ACCREDITATION: A BRIEFING FOR GOVERNMENTS AND REGULATORS

Server room guide helps energy managers reduce server consumption

Centre of Excellence in PM 2 (CoEPM 2 )

Package of initiatives on Cybersecurity

ISO / IEC 27001:2005. A brief introduction. Dimitris Petropoulos Managing Director ENCODE Middle East September 2006

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

2019 Best Practice Guidelines for the EU Code of Conduct on Data Centre Energy Efficiency

The European Single Electronic Format (ESEF)

European Union Agency for Network and Information Security

Green IT Strategies and Practices for a Sustainable Europe

The NIS Directive and Cybersecurity in

ETSI GS OEU 008 V1.1.1 ( )

Annual Report for the Utility Savings Initiative

cybersecurity in Europe Rossella Mattioli Secure Infrastructures and Services

Chain of Custody Policy. July, 2015

Revision of BREF documents in light of the Industrial Emissions Directive

Directive on Security of Network and Information Systems

EU-UNDP Capacity Building Programme on Climate Change

Brussels, 19 May 2011 COUNCIL THE EUROPEAN UNION 10299/11 TELECOM 71 DATAPROTECT 55 JAI 332 PROCIV 66. NOTE From : COREPER

Trends in data centre energy consumption under the European Code of Conduct for Data Centre Energy Efficiency

ACCREDITATION COMMISSION FOR CONFORMITY ASSESSMENT BODIES

D3.1 Validation workshops Workplan v.0

Google Cloud & the General Data Protection Regulation (GDPR)

BRE Global Limited Scheme Document SD 186: Issue No December 2017

BENCHMARKING PPP PROCUREMENT 2017 IN GABON

Call for Expressions of Interest

A GROWING CONCERN BUILT ENVIRONMENT

Progress and challenges with the establishment of MRV system in African Countries

Guidelines 1/2018 on certification and identifying certification criteria in accordance with Articles 42 and 43 of the Regulation 2016/679

CERTIFICATION BODY (CB) APPROVAL REQUIREMENTS FOR THE IFFO RESPONSIBLE SUPPLY (IFFO RS) AUDITS AND CERTIFICATION

Industry leading low energy evaporative fresh air cooling.

USDA ISO Guide 65 Program Accreditation for Certification Bodies

Repeatable IT Hub Rooms

Procurement on modernisation of the server platform of the municipality

Networking for Sustainability & Green Digital Charter

Green IT (ICT) (Accredited by British Computer Society)

IEA Network Standby Workshop. Toronto (Canada), March 8, 2013 Shailendra Mudgal BIO Intelligence Service

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

PEFC Certification System Netherlands - Certification Procedures

SAJ CHALLENGES IN SUSTAINABLE ENERGY MANAGEMENT SYSTEM DEVELOPMENT & IMPLEMENTATION

Eligibility & Certification Process ELIGIBILITY CONFIRMING ELIGIBILITY ELIGIBILITY CRITERION 1: BUILDING CHARACTERISTICS

Cybersecurity. Quality. security LED-Modul. basis. Comments by the electrical industry on the EU Cybersecurity Act. manufacturer s declaration

Discussion on MS contribution to the WP2018

Clean energy for NDCs: scaling up private financing

INSIDE THE PROTOTYPE BODENTYPE DATA CENTER: OPENSOURCE MONITORING OF OPENSOURCE HARDWARE

Accreditation Body Evaluation Procedure for AASHTO R18 Accreditation

Zero Defect Zero Effect (ZED) Certification Scheme Rating Process

Building an Assurance Foundation for 21 st Century Information Systems and Networks

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Coordination Meeting of Standardisation Activities for assessing the Environmental Impact of ICT

Cyber Security in Europe

Energy Solutions for Buildings

IOAS Operating Manual information and requirements specific to assessment against ISO/IEC 17065

Quality Assurance Procedure Use of Accreditation Body & FP Certification FZE Marks, Logos and Symbols

FSC STANDARD. Standard for Multi-site Certification of Chain of Custody Operations. FSC-STD (Version 1-0) EN

Audit Report. Scottish Bakers. 30 March 2015

European Commission Directorate General Enterprise and Industry INSTITUTIONAL FRAMEWORK ON

Toward Horizon 2020: INSPIRE, PSI and other EU policies on data sharing and standardization

Memo on Stakeholder Consultation on Article 10(2) of Directive 2012/19/EU

The European Policy on Critical Information Infrastructure Protection (CIIP) Andrea SERVIDA European Commission DG INFSO.A3

May Hands-on Guidance. Measurable Results. SUPPLIER EFFICIENCY PROGRAM

Public consultation on Counterfeit and Piracy Watch-List

Runway Safety Teams (RSTs) Description and Processes. Session 5 Presentation 1

Transcription:

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1

Why Data Centres? Continuing demand for IT services Rising DC electricity consumption projected: Western Europe: 56 TWh in 2007, projected to rise to 104 TWh in 2020 Expected to contribute substantially to the European Union (EU) commercial sector consumption Maximise energy efficiency of data centres to ensure the carbon emissions and energy consumption are mitigated 2

EU Codes of Conduct Led by European Commission Joint Research Centre Flexible mechanism to initiate and develop policy Forum for industry, experts and Member States Open and continuous dialogue on market and product performance Identify and focus on key issues and agree solutions Set ambitious voluntary standards and commitments 3

Past Successes Since 2002 Codes of Conduct on: External Power Supply Units Digital TV services Broadband Uninterruptible Power Supplies Lays groundwork which has been used by other European policies (e.g. Eco-Design) 4

Why a New Initiative? There is no EU regulatory or voluntary initiatives addressing the energy efficiency of data centres. This creates risk of confusion, mixed messages and uncoordinated activities Need for independent assessment and coordination tailored to European conditions such as the climate and energy markets regulation The new Code of Conduct provides a platform to bring together European stakeholders to discuss and agree voluntary actions which will improve energy efficiency 5

What is the Code of Conduct? Code of Conduct is a voluntary commitment of individual companies, which own or operate data centers (including colo), with the aim of reducing energy consumption (against a BaU scenario) through the adoption of best practices in a defined timescale. Energy efficiency targets are complemented by general commitments to monitor power and energy consumption, adopt management practices, switching off components not needed, and reducing energy consumption where possible 6

Aims To raise awareness among managers, owners, investors, with targeted information and material on the opportunity to improve efficiency. To provide an open process and forum for discussion representing European stakeholder requirements. To create and provide an enabling tool for industry to implement costeffective energy saving opportunities To develop a set of easily understood metrics to measure the current efficiencies and improvement. To produce a common set of principles in harmonisation with other international initiatives. To support procurement, by providing criteria for equipment (based on the Energy Star Programme specifications, when available, and other Codes of Conducts), and best practice recommendation for complex systems. 7

Scope The Code of Conduct covers: Data centres of all sizes server rooms to dedicated buildings Both existing and new IT power and Facility power Equipment procurement and system design The Code of Conduct is for: Participants: Data centre owners and operators Endorsers: Vendors, consultants, industry associations 8

Four Basic Scenarios Day to day operations (energy management) Normal replacement cycle/adding new servers Retrofit/ dedicated energy efficiency programme Designing new data centres 9

Working Groups Metrics and measurements How to measure and report efficiency Best Practice Establishing guidance and support Data collection & analysis Monitor and report on savings 10

Rules of Participation (1) For existing data centres partnership application start with an initial energy measurement, and energy audit to identify the major energy saving opportunities. An Action Plan must be prepared and submitted, once the Action Plan is accepted the Participant status in granted. Participant must implemented the Action Plan according to the agreed time table. Energy consumption must be monitored regularly, as described in the monitoring section. It is expected to see over time progresses in the energy efficiency indicator related to the data centre. 11

Rules of Participation(2) The revised retrofit and new build best practices will apply from 2011 onwards for new participants. A new construction data centre must be efficient according to the best practices from the start (design phase) and not wait to be retrofitted in the 36 months period. Energy monitoring shall start ASAP Clear identification of the type of operator & its responsabilities: Operator Colo Provider Colo Customer Managed Service Provider in Colo Managed Service Provider 12

Rules of Participation(3) The Commission will approve the plan submitted within 30 days, or explain its reasons for not approving and grant Participant status to the organisation. The Participant carries out its Action Plan, and reports at the completion of the actions to the Commission. The Commission will review the Participant 's report, and check whether it corresponds to the Action Plan. Mandatory regular (annual) reporting of monthly energy 13

Rules of Participation(4) All Participants have the obligation to continuously monitor energy consumption and adopt energy management in order to look for continuous improvement in energy efficiency. One of the key objectives of the Code of Conduct is that each Participant benchmark their efficiency overtime, using the Code of Conduct metric (or more sophisticated metrics of available) so to have evidence of continuous improvements in efficiency. 14

Best Practices Category Entire Data Centre Description Expected to be applied to all existing IT, Mechanical and Electrical equipment within the data centre New Software New IT Equipment Expected during any new software install or upgrade Expected for new or replacement IT equipment Build or retrofit 2010 onwards Expected for any data centre built or undergoing a significant refit of the M&E equipment from 2010 onwards Best Practice Intent: Neither a prescriptive nor exhaustive list of specific technologies Focussed on goals and processes Structured to allow the addition of new technologies 15

Best Practices Establish common vocabulary and terminology Provide operators with an understanding of the available technology options Their relative merits The processes they should establish The communication that is necessary The relationship between technology areas Most people are non-expert in some area(s) of the data centre Best Practices are guidance to operators on how they might improve energy efficiency Practices are scored 1-5 (min-max) based upon their likely energy use benefit Practices are ordered by score Practice scores are not intended to be summed for an overall score 16

Results Who is using the code? 58 Participants with 120 data centres 150+ MW of IT power Several large operators have stated their intent to participate Many organisations using the CoC internally Several data centre standards using the CoC best practices Data Centre Metrics 17 17

Progress so far What has worked? New build facilities Modular build Part load efficiency Air flow containment Existing facilities Air flow management IT equipment power management Regular review of cooling, set points etc Metering 18 18

Progress so far What has not worked? Environmental range Low temperature set points Low target IT intake temperature Narrow humidity control ranges Efficient software Still no metrics Hard to formally procure for something you can t easily measure Data Centre Metrics 19 19

Benefits for participants Participants will receive public recognition for their efforts, through the Code of Conduct promotion campaign, aimed at raising public awareness of energy issues. Participants may use the Code of Conduct logo publicising their energy saving actions and the contribution they are making to the environment. Participants that score a low energy for the data centre, will be allowed to indicate that are Code of Conduct Low Energy Champion and will be eligible for the annual Data Centre Awards (starts in 2011). The list of Participants, including a description of their specific contribution to energy saving will be published widely (brochure, Internet, etc.).. The Participant Data Centres may be included in promotional activities, such as Awards and the Catalogue. Participants will be invited to a Code of Conduct Stakeholder Forum to review progresses and further develop the Code of Conduct. The Code of Conduct Stakeholder Forum will meet regularly and at least once per year. 20

Participants 21

Data Analysis This analysis is taken from 89 confirmed Participant Status Data Centres, which in total represents approximately 1.5TWh of electricity consumed across Europe per year Based on 2008 energy consumption projections, this is equivalent to around 1.5% of the total energy consumed by the EU data centre industry. This cannot include new data centres which have no energy data to report. 22

Data Analysis Overview Total dataset 89 Total annual electricity consumption 1 518 696 000 kwh 1 519 GWh Average DC floor area 2 490 m 2 Average Rated IT load 2835 kw Average annual electricity consumption 17 064 000 kwh 17.1 GWh Average DCiE 57 % Minimum DCiE(excluding outliers [1] ) 37 % Maximum DCiE 91 % 23

Types of data centre 24

Efficiency 25

Efficiency Progresses 26

Temperature and humidity setpoints 27

28

Efficiency and data centre resiliency 29

Efficiency and temperature setpoints 30

Efficiency and electrical size 31

Conclusions There is increasing interest for the Cod eof Conduct among data centres operators This is the only independent pan european scheme in the EU to certify that a data centre has adopted energy efficiency best practices We collect DC data to track efficiency improvement over time We have now established an Annual Award for the best implementations 32

Thank You for Your Attention For more information contact paolo.bertoldi@ec.europa.eu http://re.jrc.ec.europa.eu/energyefficiency/html/standby_initiative_data_centers.htm 33