Green Computing: Datacentres

Similar documents
Green Computing: Datacentres

MSYS 4480 AC Systems Winter 2015

Topics. CIT 470: Advanced Network and System Administration. Google DC in The Dalles. Google DC in The Dalles. Data Centers

Green Data Centers A Guideline

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Server room guide helps energy managers reduce server consumption

Data Center Fundamentals: The Datacenter as a Computer

Warehouse-Scale Computers to Exploit Request-Level and Data-Level Parallelism

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Planning a Green Datacenter

Green Computing and Sustainability

Meeting the Energy Efficiency and Financial Challenges in IT. Liam Newcombe BCS Data Centre Specialist Group Secretary

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

Virtualization and consolidation

MEASURE MONITOR UNDERSTAND

Efficiency of Data Center cooling

CSE 124: THE DATACENTER AS A COMPUTER. George Porter November 20 and 22, 2017

Will it one day be green to shun the internet?

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Google s Green Data Centers: Network POP Case Study

CS 61C: Great Ideas in Computer Architecture (Machine Structures) Lecture 17 Datacenters and Cloud Compu5ng

EU Code of Conduct on Data Centre Energy Efficiency. Endorser Guidelines and Registration Form. Version 3.1.0

DCIM Data Center Infrastructure Management Measurement is the first step

EP s approach to Power & Energy efficiency in DCs & paradigms

18 th National Award for Excellence in Energy Management. July 27, 2017

How High-Density Colocation and Enhanced Visibility Improve Business Performance

A Computer Scientist Looks at the Energy Problem

Session 6: Data Center Energy Management Strategies

Data centers control: challenges and opportunities

Increasing Data Center Efficiency through Metering and Monitoring Power Usage

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

Rittal Cooling Solutions A. Tropp

84 kw, Tier 3, Direct Expansion, 937 ft 2

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Energy Usage in Cloud Part2. Salih Safa BACANLI

1.0 Executive Summary. 2.0 Available Features & Benefits

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

Power Monitoring in the Data Centre

Overcoming the Challenges of Server Virtualisation

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Lecture 20: WSC, Datacenters. Topics: warehouse-scale computing and datacenters (Sections )

Switch to Perfection

Data Centre Energy Efficiency Product Profile

LOT 9 and MANDATE 462 DISCUSSION

ΕΠΛ372 Παράλληλη Επεξεργάσια

Total Modular Data Centre Solutions

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Case study on Green Data Center. Reliance Jio Infocomm Limited

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Data Center Infrastructure Management (DCIM) By Jesse Zhuo

Scalable, Secure. Jason Rylands

FREEING HPC FROM THE DATACENTRE

Addressing Data Center Efficiency Lessons Learned From Process Evaluations of Utility Energy Efficiency Programs

Results of Study Comparing Liquid Cooling Methods

APC APPLICATION NOTE #74

Trends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Pros and Cons of Various DC Distribution Architectures

EUROPEAN DATA CENTRE STANDARDS

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Recapture Capacity for Existing. and Airflow Optimization

How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Thermal management. Thermal management

World Class. Globally Certified. High Availability.

Data Center Energy and Cost Saving Evaluation

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Case Study Leicester City Council

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Reliable, Energy Efficient, and Cost-Effective On-site Cogeneration and Back-up Power System for a Mission Critical Data Center

DATA CENTRE CODES AND STANDARDS

Warehouse-Scale Computing

1.0 Executive Summary

Microsoft s Cloud. Delivering operational excellence in the cloud Infrastructure. Erik Jan van Vuuren Azure Lead Microsoft Netherlands

DATA CENTER COLOCATION BUILD VS. BUY

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

COOLING WHAT ARE THE OPTIONS AND THE PROS AND CONS FOR THE VARIOUS TYPES OF DATACENTRES SERVER AND COMMS ROOMS

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Building Management Solutions. for Data Centers and Mission Critical Facilities

Newave s approach for protecting mission critical application

IT Level Power Provisioning Business Continuity and Efficiency at NTT

Application of Green Technology For Data Centre

The Evolving Data Center

DCIM Data Center Infrastructure Management

Rolf Brink Founder/CEO

The Greening of Services

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

Data Centres - Today s Changing Landscape. Tony Day Global Director Data Centre Projects & Professional Services for APC by Schneider Electric

Industry leading low energy evaporative fresh air cooling.

White Paper RiZone The Rittal Management Software for IT infrastructures

M+W Group s Visionary Delta Datacenter

CLOSE CONTROL AIR CONDITIONERS DATA CENTERS DESIGN SIDE NOTES

Transcription:

Green Computing: Datacentres Simin Nadjm-Tehrani Department of Computer and Information Science (IDA) Linköping University Sweden Many thanks to Jordi Cucurull For earlier versions of this course material January 22, 2018 1

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups 2

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Chapter 4 and 5 of the 1 st Edition of the e-book on the course web (2009) 3

Datacentres Datacenters are buildings where multiple servers and communication gear are co-located because of their common environmental requirements and for physical security needs, and ease of maintenance. Barroso and Hölzle Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer - An Introduction to the Design of Warehouse-Scale Machines. Morgan & Claypool Publishers, 2009 (120 pages). Note: a 2013 2 nd Edition of this book (156 pages) is also available with more Google-oriented updates. Most of the basic material in the 2009 is still worthwhile to study. 4

Datacentre energy consideration Data centres total energy consumption in 2012 was about 270 TWh, which was about 2% of the global electricity consumption and they had a growth rate of over 4% per year during 2007-2012. W. Van Heddeghem, et al. Trends in worldwide ICT electricity consumption from 2007 to 2012, Computer Communications, Volume 50, Elsevier, 2014.

Viral cat videos warming the planet? Not only energy consumption but also GHG emissions relevant https://www.theguardian.com/environment/2015/sep/25/ser ver-data-centre-emissions-air-travel-web-google-facebookgreenhouse-gas GeSI 2015 report: Now we find that ICT can finally decouple economic growth from emissions growth 6

Green peace clicking green (2017) The report has mixed messages of what is getting better and what is getting worse IT sector is already estimated to consume approximately 7% of global electricity 7

IT Architectural overview Server Check out virtual tours e.g. https://www.youtube.com/watch?v=zxsoygn_v7a 8 Image (left) under CC license by MrLinsky on Wikimedia

Energy use at a datacentre Datacentre overhead Server consumption From Luiz André Barroso and Urs Hölzle, 2009, Data (Right chart) from one Google facility 2007.

Power and cooling systems 10 Graphic provided courtesy of DLB Associates

Power system components Primary switchgear Breakers for protection Transformers (10-20kV to 110-600V) Diesel generators Switched on in case of utility power failure Uninterruptible Power Supply (UPS) Batteries for short term energy provision Functionality Switch energy source between mains power (from utility) and power from Diesel generators Sustain system power with batteries during mains power failure Power feed conditioning 11

Power system components Power Distribution Units (PDUs) Break a higher voltage line into several circuits 200-480V line to many 110-230V circuits that feed the servers A ground short (in server or power supply) will only break one circuit Distribute energy to each rack Provide redundancy (A-side, B-side) so that with a power supply failure fast switching can take place 12

Cooling system Computer Room Air Conditioning (CRAC) Blows cold air under the floor plenum Cold air moves to front of server racks (cold aisle) Cold air flows through server racks Warm air is expelled in the back (warm aisle) 13

Cooling: operational range Datacentre cannot operate without cooling CRAC units cool the room's air Liquid coolant is pumped from chillers or cooling towers Coils are kept cool (12-14 ºC) with liquid coolant Warm air is pushed through the coils by fans Cold air (16-20 ºC) is moved to the floor plenum Air reaches the servers at 18-22 ºC 14

Free cooling Much more efficient than chillers Cool the coolant to much lower temperatures before reaching the chiller Cooling tower Glycolbased radiator Fans to push air from outside 15 Image (left) under CC license by Frobles on Wikimedia Image (right) under CC license by cbpowerindustrial on Flickr

Redundancy and reliability Redundancy for fault tolerance and during maintenance Applied to both power and cooling systems Configurations: N+1, N+2, 2N Type Availability Description Tier I 99.67% Single path for power & cooling. No redundancy (N) Tier II 99.74% Single path for power & cooling. Redundancy (N+1) Tier III 99.98% Tier IV 99.995% Tier Classification (ANSI/TIA 942) Multiple paths for power & cooling (only one active). Concurrently maintainable. Redundancy (N+1) Multiple active paths for power & cooling. Redundancy in both paths (min (N+1)) W.Pitt Turner IV, J.H.Seader, K.G.Brill. Tier classifications define site infrastructure performance, Uptime Institute, White Paper 16

Container-based datacentres Highly efficient cooling http://news.microsoft.com/features/microsoft-research-project-puts-cloud-in-oceanfor-the-first-time/#sm.0000q5ts4lqgfez110wem1gb0ig5o

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives 18

Sources of efficiency losses Power systems Element Losses Transformers 0.50% UPSs 7-12% Highly efficient UPSs 3% Low-voltage power (110-220V) cables 1-3% Cooling Fans that move cool and warm air Mix of cool and warm air during long paths Too low temperature selection 25-27 ºC better than targeted 20 ºC 19

Energy efficiency metrics Power Usage Effectiveness (PUE) Proposed by The Green Grid association Efficiency of the IT support infrastructure PUE= Total facility power Total IT equipment power Historic data: PUEs between 1.5 and 2.0 Google, Microsoft, Apple have reported PUEs around 1.1X C. Beladi. Green Grid datacenter power efficiency metrics: PUE and DCiE. White paper. 2008 Recent data: https://www.google.com/about/datacenters/efficiency/internal/ 20

Location matters One quarter of Singapore data centers have PUE higher than 3, Japan and Australia claim average PUE of 2.2 and 2.25 respectively (APAC datacenter survey, April 2013) Facebook Luleå: 1.08 (Computer Sweden, 7 Feb 2013) Image: https://www.facebook.com/luleadatacenter

Facebook live dashboard https://www.facebook.com/forestcitydatacenter/app_288655784601722

What about Europe? Data from the 2017 EU study performed by JRC on 268 datacenters in Europe http://www.mdpi.com/1996-1073/10/10/1470/htm

Big reductions? Not really

Energy efficiency metrics PUE has to be used carefully Example: Server fans in IT-PAC Microsoft datacentre container module Facility power IT equipment power IT-PAC airflow management is improved Server fans are no longer required PUE increases Overall energy consumption reduced despite PUE increase Other aspects must be taken into account http://www.datacenterknowledge.com/archives/2011/01/31/microsoft-eliminates-server-fans-despite-pue-hit/ 25

Energy efficiency metrics Green Grid's Datacentre Performance Efficiency (DCPE) DCPE= Amount of computational work Total energy used Barroso and Hölzle propose: DCPE = 1/PUE. 1/SPUE. Computation/Total energy to electronics Computing efficiency IT equipment efficiency Building facilities efficiency 26

Energy efficiency metrics Server Power Usage Effectiveness (SPUE) Efficiency of the IT infrastructure Losses in power supply, voltage regulator modules, server fans SPUE= Total server input power Total useful power Useful power Consumption of electronics directly involved in computation E.g. motherboard, disks, CPU, DRAM... Servers have SPUEs between 1.6 and 1.8 (Barroso & Hölzle 2009) State of the art servers should be less than 1.2!!! 27

Energy efficiency metrics Total Power Usage Effectiveness (TPUE) Show efficiency of electromechanical overheads. TPUE= PUE SPUE Example: 2.0 PUE 1.6 SPUE TPUE= 2.0 1.6= 3.2 For each productive Watt another 2.2 W consumed!!! 28

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives 29

Load and energy efficiency Most of the time spent in no energy-efficient load regions Activity profile of 5000 Google servers in 6 months Image from Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer 2009. 30

Load and energy efficiency Almost no time in idle state In low load there are several hundreds of queries Load spread out over all available servers Optimised for performance and/or availability Sustainable approach Concentrate load in a few servers Switch off unused servers But!!! More software complexity Energy for data distribution 31

Recall from lecture 2 Consumption proportional to the load Ideal linear function without constants 120 100 Energy (%) 80 60 40 20 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) Ideal energy proportional server Traditional server Traditional server data based on data from Barroso and Hölzle 2009. 32

Energy proportional computing Capacity to adapt consumption to load Device Dynamic power CPU 3.0x Memory 2.0x Disks 1.3x Network switches 1.2x More hardware improvements are required!!! Meanwhile only option is to switch off hardware!!! 33

Energy spent: revisited CPU a larger proportion of energy costs than that reported in 2009! Luiz André Barroso and Urs Hölzle. The Datacenter as a Computer, 2 nd Edition 2013

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives 35

Current specifications ENERGY STAR Program Requirements for Computer Servers 2.0 (Dec 2013) Includes active consumption as opposed to just idle consumption Requirements for Datacenter Storage 1.0 establishes maximum consumption of storage products 2014: Microsoft joined Facebook to lead the Open Compute Project on servers http://blogs.technet.com/b/microsoft_blog/archive/2014/01/27/ microsoft-contributes-cloud-server-designs-to-the-open-computeproject.aspx 36

EU Code of Conduct for Datacentres European action to reduce consumption of datacentres Best practices for datacentres operators V3.0 Guide (Feb 2011) Operators register and commit to their application Roles of applicant Participant Operator of datacentre or equipment in it Commitments Annual reporting of energy consumption Implementation of some of the best practices Endorser Supports the initiative and participants http://iet.jrc.ec.europa.eu/energyefficiency/ict-codes-conduct/datacentres-energy-efficiency 37

EU Code of Conduct for Data Centres Scope of the best practices Datacentre utilisation, management and planning IT equipment and services Cooling Datacentre power equipment Other equipment Building Monitoring Best practice expected implementation Immediate During software install or update During new IT introduction or replacement During building of datacenter or retrofit Optional 38

This lecture Datacentre design Efficiency metrics Energy-proportional computing Initiatives Seminar groups 39

We start the first Seminar (Sem 0) in the next slot!