NetSure 802 SERIES DC POWER SYSTEM

Similar documents
DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

GUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & Battery -48VDC 500A 26.8kW

Ordering Guide Compact Power Systems

Candeo SP Power System AP6C55AA User Manual

Liebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications

Connecting a Cisco Input Module

Cisco CRS 16-Slot Chassis Power Systems

Liebert Precision Power Center

TECHNICAL DESCRIPTION

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert STS2/PDU, Static Transfer Switch 2/Power Distribution Unit. A Streamlined Package For Power Distribution And Source Switching

Connecting a Cisco Output Module

NetSure -48 VDC Power System

DeltaV Electronic Marshalling for Migrations

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

Liebert. STS2/PDU, Static Transfer Switch 2/ Power Distribution Unit A Streamlined Package For Power Distribution And Source Switching

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

NetSure -48V DC Bulk Output Power System

DATA CENTER TRANSFORMATION: THE IMPACT OF EMERGING POWER ARCHITECTURES ON TODAY S DATA CENTERS

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Installation Manual. Integrated System. V-Series Power Family Doc. No , Issue 8 Published 11-Dec-09

Connecting a Cisco Reader Module

Integrated Battery Control System LBCS Step-by-Step Setup Guide

GPS 2436 Infinity Power System

GPS 4827 Infinity Power System

Documentation Supplement for Marine Smart-UPS SRT5KRMXLIM, SRT6KRMXLIM External Battery Pack SRT192RMBPM

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

PDI Modular Compact Remote Power Panel

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Electrical Demand Specification (Reference SOP: )

Power distribution solutions for the ProLiant DL580 G2 server

Surge Protective Devices. STV25K Series. Instruction Manual

High Voltage Power Supply (MMPS) - Troubleshooting Guide

EMC1600 Series Media Converter and Ethernet Extender Chassis

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

User Manual. PowerShift V1. Document # Version B

Vertiv Local Rack Access 18.5" LED LCD Console

FMP VDC RECTIFIER 42 Amps 2000 Watts

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

How do I... If you manage a datacenter, we have a solution for you.

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

4100/ VDC Converter Installation Instructions

Eaton DC Power Solutions

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Single and Double pole relays rated for 20 amps 120, 230, 277, and 347 volts

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Verizon Wiring Manual PowerShift. 10 January 2018

ControlWave Micro Digital Input / Output Modules

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

S-series Electronic Marshalling for Migrations

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Application Techniques CENTERLINE 2100 Motor Control Centers

IIM Warwick Court. Williamsburg VA REV 5

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

Uninterruptible Power Supplies

RT4F-110V/25A RECTIFIER

EnCell Battery Cell Monitor

ULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

ADDENDUM FOR 20, 27, & 28 OPTIONS

Jtec 10kA Miniature Circuit Breaker

SAVE THESE INSTRUCTIONS

16-Channel Input Digital Input Termination Card

GXT 2U Configuration Program

Chloride. FP-60z 5 160kVA 1ph / 3ph Industrial AC UPS System

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

VersaMax IP. Proficy Machine Edition. Publication Reference Chart

Click Desktop Kit. Click Desktop Kit

Building Energy Management Training Systems

Power. Ordering Guide

Installing the Cisco AS5400XM Universal Gateway

Liebert. EXL UPS 800 and 1200kVA Single Module and Multi-Module Systems

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

DECam PFC Power Distribution Chassis (Production Version)

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Analog Output Module Installation Instructions

Series 230 Automatic Transfer Switch

Data Manager Installation Guide

Quick Start Installation Guide

AirTest Model CN9000 Series Sensor Controller

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

MC 11 EB-2 Power supply cabinet with external bus, AC version

GPS 4830 Power System

Transcription:

NetSure 802 SERIES DC POWER SYSTEM Ordering Guide DRAFT

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Description The modular NetSure 802 power system is made up of an assortment of bays that can be configured to meet any large -48 Volt power requirement from 1000 A to 16,000 A. The basic power unit is a nominal 200 A rectifier capable of up to 220 amps each at current limit. The system accommodates up to 10 rectifiers per bay, and the bays can be configured for distributed or centralized applications. There are also bays configured to retrofit 200 amp and 400 amp ferro rectifiers with minimum AC infrastructure cost. Click on a page number below to jump to that page. To return to the Table of Contents, click on the header of any page. Table of Contents Step 1. Select System Frame(s), Main Bay or Supplemental Bay...3 Step 2. Optional - Select Distribution Frame...3 Step 3. Select Input Voltage Source (AC Input Source)...4 Step 4. Select Rectifier Model...4 Step 5. Optional - Select AC Service Cabinet (PDSC)...4 Step 6. Optional - Select Transient Voltage Surge Suppression (TVSS).................4 Step 7. Select Controller Accessory Cards...5 Step 8. Select LMS1000 Monitoring Options...5 Step 8a. Select LMS1000 Card/Software Options...6 Step 9. Select DC Distribution Device Types...7 Step 9a. Choose TPL Style Fuses...7 Step 9b. Choose GJ/218 Style Breakers...8 Step 9c. Choose Bullet-Type Circuit Breakers and Adapter Kit (continued)... 10 Step 9d. Choose TLS/TPS Fuses with Bullet-Type Fuse Holders...11 Step 11. Optional - Select Internal Return Bar (as needed)...13 Step 12. Optional - Select External Termination Bus Assembly...13 Step 13. Optional - Select External Return Bar Option...14 Step 14. Order Accessories (as needed)...15 NetSure 802 Power Bay Power Bay with Distribution Bay REQUESTER CONTACT INFORMATION: Name:* Title:* Company:* Email/Phone:* * These are required fields. Please complete. Please SAVE this form to your desktop. Then email the completed form to: AccountManagement.ESNA@VertivCo.com 200 A Ferro Retrofit Power Bay 400 A Ferro Retrofit Power Bay 2

DRAFT Step 1. Select System Frame(s), Main Bay or Supplemental Bay Select one, quantity of one per system. List 1 58214000001 List 2 58214000002 List 3* 58214000003 List 4* 58214000004 List 5* 58214000005 DESCRIPTION QTY. NOTES Main power/distribution frame, equip for individual AC feed per rectifier Main power/distribution frame, equip for bulk AC feed per frame Main power bay frame, 5 discrete AC inputs per bay (5 feed) for 400 A ferro retrofit application Main power bay frame, 2 discrete AC inputs per bay (2 feed) Main power bay frame, individual AC inputs per rectifier (10 feed) for 200 A Ferro retrofit applications or direct feed from existing AC PDSC (1) Main frame type required per system. Maximum of 10 rectifiers/bay. Must select AC service cabinet option in Step 5. (1) Main frame type required per system. Maximum of 10 rectifiers/bay. (1) Main frame type required per system. Maximum of 10 rectifiers/bay. (1) Main frame type required per system. Maximum of 10 rectifiers/bay. * Must be used with external main battery termination bars. Select quantity as needed per system. VERTIV List 11 58214000011 List 12 58214000012 List 13* 58214000013 List 14* 58214000014 List 15* 58214000015 DESCRIPTION QTY. NOTES Secondary power/distribution frame, equip for individual AC feed per rectifier Secondary power/distribution frame, equip for bulk AC feed per frame Secondary power bay frame, 5 discrete AC inputs per bay (5 feed) for 400 A ferro retrofit application Secondary power bay frame, 2 discrete AC inputs per bay (2 feed) Secondary power bay frame, individual AC inputs per rectifier (10 feed) for 200 A Ferro retrofit applications or direct feed from existing AC PDSC Order as required. Maximum of 10 rectifiers/bay. System can support up to (9) secondary frames as needed. Must select AC service cabinet option in Step 5. Order as required. Maximum of 10 rectifiers/bay. System can support up to (9) secondary frames as needed. Order as required. Maximum of 10 rectifiers/bay. System can support up to (9) secondary frames as needed. Order as required. Maximum of 10 rectifiers/bay. System can support up to (9) secondary frames as needed. Order as required. Maximum of 10 rectifiers/bay. System can support up to (9) secondary frames as needed. * Must be used with external main battery termination bars. Step 2. Optional - Select Distribution Frame Select quantity as needed if applicable. VERTIV List 16 58214000016 List 17 58214000017 List 18 58214000018 List 19 58214000019 List 22 58214000022 DESCRIPTION QTY. NOTES Distribution only bay (cable only bay) for use with external main battery termination bars, left or right expansion Distribution only bay with internal busbars (2nd bay), left or right expansion 1st distribution only bay with internal busbars, expansion to the right Expansion busbars for distribution only bay to bridge PDSC 1st distribution only bay with internal busbars, expansion to the left Order as required. System can support up to (5) distribution frames as needed. Order as required. System can support up to (5) distribution frames as needed. Order as required. System can support up to (5) distribution frames as needed. Only required if a PDSC is located between the power/distribution bay and the distribution only bay Order as required. System can support up to (5) distribution frames as needed. 3

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 3. Select Input Voltage Source (AC Input Source) Select Select one, quantity of one. List 0A 5821400000A 480 VAC, 3 phase input (4-wire circuit) List 0B 5821400000B 208 VAC, 3 phase input (4-wire circuit) DESCRIPTION QTY. RACK SPACE Step 4. Select Rectifier Model VERTIV DESCRIPTION QTY. RACK SPACE PICTORIAL n/a 486534003* High efficiency 200 amp esure rectifier R4812000Le (208 VAC), 3 phase input n/a 486532603* High efficiency 200 amp esure rectifier R4812000e (480 VAC), 3 phase input * 200 A is nominal rating. These units are capable of current limiting up to 220 A each. Step 5. Optional - Select AC Service Cabinet (PDSC) Must be selected if List 2 or List 12 was selected in Step 1. VERTIV List 30 58214000030 List 31 58214000031 List 32 58214000032 DESCRIPTION QTY. NOTES 480 VAC input bolt-on PDSC (22 kaic rated breakers) 480 VAC input bolt-on PDSC (65 kaic rated breakers) 208 VAC input bolt-on PDSC (65 kaic rated breakers) Select the quantity of cabinets needed by to total number of List 2 and List 12's needed in total. Select the quantity of cabinets needed by to total number of List 2 and List 12's needed in total. Select the quantity of cabinets needed by to total number of List 2 and List 12's needed in total. Step 6. Optional - Select Transient Voltage Surge Suppression (TVSS) Must be selected if Lists 2, 4, 12 or 14 were selected in Step 1. VERTIV List 35 58214000035 List 36 58214000036 List 37 58214000037 List 38 58214000038 DESCRIPTION QTY. NOTES 480 VAC input surge suppression for use in the PDSC cabinet 208 VAC input surge suppression for use in the PDSC cabinet 480 VAC input surge suppression for use in the power bays (List 4 and 14) 208 VAC input surge suppression for use in the power bays (List 4 and 14) For use with List 30 or 31 AC service cabinets only. (1) required for each AC service cabinet. For use with List 32 AC service cabinets only. (1) required for each AC service cabinet. For use with List 4 and 14 when equipped for 480 VAC input. For use with List 4 and 14 when equipped for 208 VAC input. 4

DRAFT LMS 1000 LORAIN MONITORING UNIT 1 1. MCA Circuit Card, (Primary Bay) List 1, 2, 3, 4, 5 Router Circuit Card (Secondary Bay) List 11, 12, 13, 14, 15 2 3 2. Optional LMS Main CPU Circuit Card, List 50 or Optional LMS Expansion CPU Circuit Card, List 63 3. Available MCA Input/Output (I/O) Circuit Cards: -- MCA Customer Alarm Relay Card (6 Form-C Contacts), List 70 -- MCA Analog Input/Output and Binary Input Circuit Card, List 71 Step 7. Select Controller Accessory Cards Select one, quantity of one, if desired. DESCRIPTION QTY. NOTES List 70 58214000070 MCA alarm relay card Provide (6) Form-C alarm user defined output relays. (Each primary frame is factory equipped with [2]). List 71 58214000071 MCA analog and binary I/O card Provide (4) binary inputs plus (1) analog input and (1) analog output signal. Step 8. Select LMS1000 Monitoring Options Select List 50 for all main bays (lists 1-5). Select list 63 for supplemental bays if required. VERTIV DESCRIPTION QTY. NOTES List 50 58214000050 LMS1000 main CPU card Order 1 list 50 for each main bay ordered (lists 1, 2, 3, 4 or 5). List 63 58214000063 LMS1000 CPU expansion card Requires the main CPU card. This option mounts into the LMS chassis slot for all supplemental bays to enable all LMS cards in expansion bays. NOTE: Refer to SAG586505000 for additional LMS options. 5

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 8a. Select LMS1000 Card/Software Options Select at least 1 analog card for battery monitoring (58650500020) and 1 binary card for battery disconnect status (58650500031). Order additional cards as necessary. LMS 1000 Cards Select quantity as needed n/a 58650500020 Four (4) channel analog input card DESCRIPTION QTY. NOTES Select the required amount and type of current limit resistor kits (List BA, BB, or BC) or in-line fuse kits (List BE, BF, or 535135) n/a 58650500021 Eight (8) channel temperature input card Select the required amount and type of temperature sensors (List ST or SU) n/a 58650500022 Eight (8) channel analog input card n/a 58650500023 Twelve (12) channel analog input card - battery cell voltage n/a 58650500030 Four (4) channel binary input card n/a 58650500031 Eight (8) channel binary input card n/a 58650500040 Four (4) channel Form-C relay output card n/a 58650500070 Modem circuit card Software Options Select as many below as required n/a 58650500078 LMS dual MCA interface software option Select the required amount and type of current limit resistor kits (List BA, BB, or BC) Select the required amount and type of in-line fuse kits (List BE, BF, or 535135) Select the required amount and type of current limit resistor kits (List BA, BB, or BC) or in-line fuse kits (List BE, BF, or 535135). n/a 58650500079 Gateway port software option Select the required amount and type of temperature sensors (List ST or SU). n/a 58650500086 TL1/X.25 software option n/a 58650500087 Power metering software option n/a 58650500090 TL1 (over Ethernet) software option Accessories Select as many below as required n/a 586505000BA Current limit resistor kit, 3/8" ring lug n/a 586505000BB Current limit resistor kit, splice n/a 586505000BC Current limit resistor kit, 5/16" ring lug n/a 586505000BE In-line fuse kit, 3/8" ring lug n/a 586505000BF In-line fuse kit, 5/16" ring lug n/a 535135 n/a n/a 586505000ST 586505000SU In-line fuse kit, 1/4" ring lug, 3/8" ring lug, 5/16" ring lug, or butt splice Temperature sensor, mounts to a 5/16" or M8 battery post Temperature sensor, mounts to a 1/4" or M6 battery post Provides (25) shunt inputs. Maximum quantity of one per bay. For use with GJ/218 breakers with shunts or TPH or TPL-B fuse panels with shunts. Mounts internal to power system. Provides (25) shunt inputs. Maximum quantity of one per bay. For use with GJ/218 breakers with shunts or TPH or TPL-B fuse panels with shunts. Mounts internal to power system. Provides (8) temperature inputs. Maximum quantity of eight per system. Mounts external to power system. Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management. Comprised of 0.3 m length sensor and 10 m length extension. Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management. Comprised of 0.3 m length sensor and 10 m length extension. Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management. Comprised of 0.3 m length sensor and 10 m length extension. Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management. Comprised of 0.3 m length sensor and 10 m length extension. Provides temperature monitoring and alarming for battery or ambient. Battery-assigned probes provide temperature compensation and battery thermal runaway management. Comprised of 0.3 m length sensor and 10 m length extension. 6

DRAFT Step 9. Select DC Distribution Device Types Select quantity and type as needed. Step 9a. Choose TPL Style Fuses DESCRIPTION QTY. POLES USED NOTES PICTORIAL n/a 248251500 Fuse, TPL-C, 70 A 2 Uses (1) 514403 fuseholder n/a 248252000 Fuse, TPL-C, 80 A 2 Uses (1) 514403 fuseholder n/a 248252600 Fuse, TPL-B, 100 A 2 Uses (1) 514403 fuseholder n/a 248253300 Fuse, TPL-B, 150 A 2 Uses (1) 514403 fuseholder n/a 248254000 Fuse, TPL-B, 200 A 2 Uses (1) 514403 fuseholder n/a 248254500 Fuse, TPL-B, 225 A 2 Uses (1) 514403 fuseholder n/a 248255000 Fuse, TPL-B, 250 A 2 Uses (1) 514403 fuseholder n/a 248255700 Fuse, TPL-C, 300 A 2 Uses (1) 514403 fuseholder n/a 248257000 Fuse, TPL-C, 400 A 2 Uses (1) 514403 fuseholder n/a 248258000 Fuse, TPL-C, 500 A 2 Uses (1) 514403 fuseholder n/a 248259000 Fuse, TPL-C, 600 A 2 Uses (1) 514403 fuseholder n/a 102901 Fuse, TPL-C, 800 A 3 Uses (1) 514404 fuseholder For each fuse needed, order (1) 248610301 GMT alarm fuse (18/100 A) and (1) 248898700 GMT fuse safety cover. n/a 248610301 GMT alarm fuse, 18/100 A n/a 248898700 GMT fuse safety cover For each fuse needed, order (1) of the listed fuseholders; for all fuses 600 A or less, the 514403 is the recommended device. n/a 514403 TPL fuse holder, 600 A max n/a 514404 TPL fuse holder, 800 A max 7

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 9b. Choose GJ/218 Style Breakers DESCRIPTION QTY. POLES USED POWER/DIST. BAY LUG ADAPTER DISTRIBUTION ONLY BAY LUG ADAPTER Electrical Trip Alarm (White Handle) GJ/218 Style Breakers with Internal Shunt n/a 513766 100 A circuit breaker, E-trip 1 520891 Not required n/a 513768 125 A circuit breaker, E-trip 1 520891 Not required n/a 513770 150 A circuit breaker, E-trip 1 520891 Not required n/a 513772 175 A circuit breaker, E-trip 1 520891 Not required n/a 513774 200 A circuit breaker, E-trip 1 520891 Not required n/a 513776 225 A circuit breaker, E-trip 1 520891 Not required n/a 513778 250 A circuit breaker, E-trip 1 520891 Not required n/a 513780 300 A circuit breaker, E-trip 2 520892 529132 n/a 513782 350 A circuit breaker, E-trip 2 520892 529132 n/a 513784 400 A circuit breaker, E-trip 2 520892 529132 n/a 513786 450 A circuit breaker, E-trip 3 520893 529131 n/a 513788 500 A circuit breaker, E-trip 3 520893 529131 n/a 513790 600 A circuit breaker, E-trip 3 520893 529131 n/a 513792 800 A circuit breaker, E-trip 4 520894 534420 Electrical/Mechanical Trip Alarm (Black Handle) GJ/218 Style Breakers with Internal Shunt n/a 513767 100 A circuit breaker, E/M-trip 1 520891 Not required n/a 513769 125 A circuit breaker, E/M-trip 1 520891 Not required n/a 513771 150 A circuit breaker, E/M-trip 1 520891 Not required n/a 513773 175 A circuit breaker, E/M-trip 1 520891 Not required n/a 513775 200 A circuit breaker, E/M-trip 1 520891 Not required n/a 513777 225 A circuit breaker, E/M-trip 1 520891 Not required n/a 513779 250 A circuit breaker, E/M-trip 1 520891 Not required n/a 513781 300 A circuit breaker, E/M-trip 2 520892 529132 n/a 513783 350 A circuit breaker, E/M-trip 2 520892 529132 n/a 513785 400 A circuit breaker, E/M-trip 2 520892 529132 n/a 513787 450 A circuit breaker, E/M-trip 3 520893 529131 n/a 513789 500 A circuit breaker, E/M-trip 3 520893 529131 n/a 513791 600 A circuit breaker, E/M-trip 3 520893 529131 n/a 513793 800 A circuit breaker, E/M-trip 4 520894 534420 PICTORIAL 8

DRAFT Step 9c. Choose Bullet-Type Circuit Breakers and Adapter Kit DESCRIPTION QTY. NOTES PICTORIAL Toggle Handle Electrical Trip Alarm (White Handle) Bullet Breakers n/a 102272 CB, 1 A, bullet, toggle handle, E-trip Occupies one position n/a 102273 CB, 3 A, bullet, toggle handle, E-trip Occupies one position n/a 102274 CB, 5 A, bullet, toggle handle, E-trip Occupies one position n/a 102275 CB, 10 A, bullet, toggle handle, E-trip Occupies one position n/a 102276 CB, 15 A, bullet, toggle handle, E-trip Occupies one position n/a 102277 CB, 20 A, bullet, toggle handle, E-trip Occupies one position n/a 102278 CB, 25 A, bullet, toggle handle, E-trip Occupies one position n/a 102279 CB, 30 A, bullet, toggle handle, E-trip Occupies one position n/a 102280 CB, 35 A, bullet, toggle handle, E-trip Occupies one position n/a 102281 CB, 40 A, bullet, toggle handle, E-trip Occupies one position n/a 121998 CB, 45 A, bullet, toggle handle, E-trip Occupies one position n/a 102282 CB, 50 A, bullet, toggle handle, E-trip Occupies one position n/a 102283 CB, 60 A, bullet, toggle handle, E-trip Occupies one position n/a 102284 CB, 70 A, bullet, toggle handle, E-trip Occupies one position n/a 102285 CB, 75 A, bullet, toggle handle, E-trip Occupies one position n/a 121996 CB, 80 A, bullet, toggle handle, E-trip Occupies one position n/a 102286 CB, 100 A, bullet, toggle handle, E-trip Occupies one position n/a 516991 CB, 125 A, bullet, toggle handle, E-trip Occupies two positions n/a 516993 CB, 150 A, bullet, toggle handle, E-trip Occupies (2) positions, space required n/a 144883 CB, 175 A, bullet, toggle handle, E-trip Occupies (2) positions, space required n/a 121831 CB, 200 A, bullet, toggle handle, E-trip Occupies (2) positions, space required n/a 144885 CB, 225 A, bullet, toggle handle, E-trip Occupies (3) positions, space required n/a 121835 CB, 250 A, bullet, toggle handle, E-trip Occupies (3) positions, space required n/a 513747 Circuit breaker/fuseholder mounting assembly Order (1) 513747 assembly for every six circuit breaker/fuseholder combinations required. Each assembly occupies (3) larger "pole" positions in the distribution section. For use with lists 1, 2, 11 & 12 only. 9

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 9c. Choose Bullet-Type Circuit Breakers and Adapter Kit (continued) DESCRIPTION QTY. NOTES PICTORIAL Toggle Handle Electrical/Mechanical Trip Alarm (Black Handle) Bullet Breakers n/a 101596 CB, 1 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101597 CB, 3 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101598 CB, 5 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101599 CB, 10 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101600 CB, 15 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101601 CB, 20 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101602 CB, 25 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101603 CB, 30 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101604 CB, 35 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101605 CB, 40 A, bullet, toggle handle, E/M-trip Occupies one position n/a 121997 CB, 45 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101606 CB, 50 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101607 CB, 60 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101608 CB, 70 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101609 CB, 75 A, bullet, toggle handle, E/M-trip Occupies one position n/a 121995 CB, 80 A, bullet, toggle handle, E/M-trip Occupies one position n/a 101610 CB, 100 A, bullet, toggle handle, E/M-trip Occupies one position n/a 516838 CB, 125 A, bullet, toggle handle, E/M-trip Occupies two positions n/a 516839 CB, 150 A, bullet, toggle handle, E/M-trip Occupies (2) positions, space required n/a 144884 CB, 175 A, bullet, toggle handle, E/M-trip Occupies (2) positions, space required n/a 121832 CB, 200 A, bullet, toggle handle, E/M-trip Occupies (2) positions, space required n/a 144886 CB, 225 A, bullet, toggle handle, E/M-trip Occupies (3) positions, space required n/a 121836 CB, 250 A, bullet, toggle handle, E/M-trip Occupies (3) positions, space required n/a 513747 Circuit breaker/fuseholder mounting assembly Order (1) 513747 assembly for every six circuit breaker/fuseholder combinations required. Each assembly occupies (3) larger "pole" positions in the distribution section. For use with lists 1, 2, 11 & 12 only. 10

DRAFT Step 9d. Choose TLS/TPS Fuses with Bullet-Type Fuse Holders DESCRIPTION QTY. NOTES PICTORIAL n/a 117201 Fuse holder, TLS/TPS, bullet type Order one fuse holder per fuse n/a 248230900 Fuse, TLS/TPS, 3 amps Occupies one position n/a 248231000 Fuse, TLS/TPS, 5 amps Occupies one position n/a 248231200 Fuse, TLS/TPS, 6 amps Occupies one position n/a 248231500 Fuse, TLS/TPS, 10 amps Occupies one position n/a 248231800 Fuse, TLS/TPS, 15 amps Occupies one position n/a 248232100 Fuse, TLS/TPS, 20 amps Occupies one position n/a 248232400 Fuse, TLS/TPS, 25 amps Occupies one position n/a 248232700 Fuse, TLS/TPS, 30 amps Occupies one position n/a 248233300 Fuse, TLS/TPS, 40 amps Occupies one position n/a 248233900 Fuse, TLS/TPS, 50 amps Occupies one position n/a 248234200 Fuse, TLS/TPS, 60 amps Occupies one position n/a 248234500 Fuse, TLS/TPS, 70 amps Occupies one position n/a 118413 Fuse, TLS/TPS, 80 amps Occupies one position n/a 118414 Fuse, TLS/TPS, 90 amps Occupies one position n/a 118415 Fuse, TLS/TPS, 100 amps Occupies one position n/a 139052 Fuse, TLS/TPS, 125 amps Occupies one position n/a 513747 Circuit breaker/fuseholder mounting assembly Order (1) 513747 assembly for every six circuit breaker/fuseholder combinations required. Each assembly occupies (3) larger "pole" positions in the distribution section. 11

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 10. Optional - Select Small Distribution for Distribution Bay (List 16) Order smaller circuit breakers and fuses from Step 8c and 8d above. DESCRIPTION QTY. PICTORIAL List 0C 5821400000C Bullet nose fuse/circuit breaker panel for use in 58214000016 distribution bay n/a 509128 Fuse module, ten (10) GMT fuse positions n/a 248610301 Fuse, GMT, 18/100 amp n/a 248610200 Fuse, GMT, 1/4 amp n/a 248610300 Fuse, GMT, 1/2 amp n/a 248610500 Fuse, GMT, 3/4 amp n/a 248610700 Fuse, GMT, 1-1/3 amps n/a 248610800 Fuse, GMT, 2 amps n/a 248610900 Fuse, GMT, 3 amps n/a 248611000 Fuse, GMT, 5 amps n/a 248611300 Fuse, GMT, 7-1/2 amps n/a 248611200 Fuse, GMT, 10 amps n/a 248611500 Fuse, GMT, 15 amps n/a 102774 Replacement safety cover n/a 248872600 Replacement dummy fuse 12

DRAFT Step 11. Optional - Select Internal Return Bar (as needed) Select one, quantity of one, if desired. Note restrictions. DESCRIPTION QTY. NOTES PICTORIAL n/a 554862 2000 A ground bar kit, internal Internal ground bar kit recommended for use with >100 A distribution devices. Mounts only in List 1, 2, 11, or 12 power/distribution frames. n/a 555214 2000 A ground bar kit, internal Internal ground bar kit recommended for use with >200 A distribution devices. Mounts only in List 1, 2, 11, or 12 power/distribution frames. Step 12. Optional - Select External Termination Bus Assembly Select one, quantity of one, if desired. Note restrictions. VERTIV DESCRIPTION QTY. NOTES PICTORIAL n/a 554873 External top-mount horizontal battery input bus assembly Provides for external battery input landings for use with List 1, 2, 3, 4, 5, 11, 12, 13, 14, and 15. Lug sizes should be 3/8" x 1.000" centers. Rated for 2000 A each. n/a 528482 Busbar shield kit Lexan kit provides protection on -48 V bus. For use with 554873 kit. n/a 554874 External top-mount vertical batter input bus assembly Order (1) per bay as required. Must be mounted on top of 554873 bus assembly. Includes Lexan shields. 13

NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Step 13. Optional - Select External Return Bar Option Select one, quantity of one, if desired. Note restrictions. n/a 514688 DESCRIPTION QTY. NOTES PICTORIAL External ground return bar, 6000 A Must be used with 554873 kits. For use with List 1, 3, 4, 5, 11, 13, 14 and 15 frames. n/a 514689 External ground return bar, 10,000 A Must be used with 554873 kits. For use with List 1, 3, 4, 5, 11, 13, 14 and 15 frames. n/a 514690 External ground return bar, 6000 A Must be used with 554873 kits. For use only with List 2 and 12 frames. n/a 514691 External ground return bar, 10,000 A Must be used with 554873 kits. For use only with List 2 and 12 frames. n/a 514543 Load return lug expansion busbar Mounts to any of the available 6000 A or 10,000 A external ground return bar options. 14

DRAFT Step 14. Order Accessories (as needed) Select quantity and vertical rack spacing as desired and as relay rack space allows. n/a 107021 Temperature probe, 25' long n/a 106824 Temperature probe, 100' long DESCRIPTION QTY. RACK SPACE NOTES List 64 58214000064 Interface kit to LVPS power system e/w DGU List 65 58214000065 Interface kit to LVPS power system e/w LMS1000 n/a 550281 3000 A external main termination bar, no shunt (1) power bay (1) distribution bay n/a 550282 5000 A external main termination bar, no shunt (2) power bays (1) distribution bay n/a 550283 5000 A external main termination bar, no shunt (2) power bays (2) distribution bays n/a 550284 7500 A external main termination bar, no shunt (3) power bays (2) distribution bays n/a 550285 7500 A external main termination bar, no shunt (3) power bays (3) distribution bays n/a 550286 10,000 A external main termination bar, no shunt (4) power bays (2) distribution bays n/a 550287 10,000 A external main termination bar, no shunt (4) power bays (3) distribution bays n/a 550291 3000 A external main termination bar, e/w shunt (1) power bay (1) distribution bay n/a 550292 5000 A external main termination bar, e/w shunt (2) power bays (1) distribution bay n/a 550293 5000 A external main termination bar, e/w shunt (2) power bays (2) distribution bays n/a 550294 7500 A external main termination bar, e/w shunt (3) power bays (2) distribution bays n/a 550295 7500 A external main termination bar, e/w shunt (3) power bays (3) distribution bays n/a 550296 10,000 A external main termination bar, e/w shunt (4) power bays (2) distribution bays n/a 550297 10,000 A external main termination bar, e/w shunt (4) power bays (3) distribution bays COMMENTS Please SAVE this form to your desktop. Then email the completed form to: AccountManagement.ESNA@VertivCo.com Contact your local sales representative with questions or call 1-800-800-1280 for support. 15

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. DC-00003 (RA06/17)