Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs

Similar documents
Lenovo SAN Manager - Provisioning and Mapping Volumes

Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems

Lenovo RAID Introduction Reference Information

Stellar performance for a virtualized world

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

IBM XIV Storage System

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

ServeRAID C100 and C105 Product Guide

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Lenovo Software Defined Storage with Windows Server 2016 Datacenter Storage Spaces

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

System x Server for SAP Business One, version for SAP HANA

NEC M100 Frequently Asked Questions September, 2011

PowerVault MD3 Storage Array Enterprise % Availability

Assessing performance in HP LeftHand SANs

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide

Benefits of the IBM Storwize V7000 Real-time Compression feature with VMware vsphere 5.5

Virtualized Storage for VMware Virtual Infrastructure. Presented by: John Martin Consulting Systems Engineer, NetApp

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure

Vurtualised Storage for VMware Virtual Infrastructures. Presented by: Rob Waite Consulting Systems Engineer, NetApp

Lenovo Database Configuration

StorMagic SvSAN: A virtual SAN made simple

Data center requirements

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

IBM FileNet Content Manager and IBM GPFS

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

Here is Your Customized Document

IBM Storwize V7000: For your VMware virtual infrastructure

Dell EMC SAN Storage with Video Management Systems

EMC Backup and Recovery for Microsoft Exchange 2007

Veritas Storage Foundation for Windows by Symantec

OSIG Change History Article

System Monitor - Performance Monitoring Services 5.8 User's Guide

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

PESIT Bangalore South Campus

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

Lenovo Database Configuration Guide

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller

IBM High IOPS MLC Adapters Product Guide

Eliminate the Complexity of Multiple Infrastructure Silos

vsan Mixed Workloads First Published On: Last Updated On:

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

SvSAN Data Sheet - StorMagic

Configuring and Managing Virtual Storage

VMware VMFS Volume Management VMware Infrastructure 3

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

ServeRAID H1110 SAS/SATA Controller Product Guide

Using IBM FlashSystem V9000 TM to virtualize existing storage

VMware Virtual SAN. High Performance Scalable Storage Architecture VMware Inc. All rights reserved.

Delivering unprecedented performance, efficiency and flexibility to modernize your IT

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

White Paper FUJITSU Storage ETERNUS DX S4/S3 series 512e HDDs: Technology, Performance and Configurations

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

Using the ThinkServer SA120 Disk Array

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Hedvig as backup target for Veeam

EMC Integrated Infrastructure for VMware. Business Continuity

2014 VMware Inc. All rights reserved.

DELL EMC UNITY: VIRTUALIZATION INTEGRATION

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

Using IBM FlashSystem V9000 TM with the VMware vstorage APIs for Array Integration

Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

Configuration Maximums VMware Infrastructure 3: ESX Server 3.5 Update 2, ESX Server 3i version 3.5 Update 2, VirtualCenter 2.

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

ActiveScale Erasure Coding and Self Protecting Technologies

Data Sheet FUJITSU Storage ETERNUS DX100 S3 Disk System

The term "physical drive" refers to a single hard disk module. Figure 1. Physical Drive

EMC Backup and Recovery for Microsoft Exchange 2007 SP1. Enabled by EMC CLARiiON CX4-120, Replication Manager, and VMware ESX Server 3.

VMware vsphere with ESX 4.1 and vcenter 4.1

EMC VSPEX END-USER COMPUTING

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

HP StorageWorks P4500 SAS SAN vs. Dell EqualLogic PS6000XV: Feature and Functionality Comparison

Using EMC FAST with SAP on EMC Unified Storage

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Rapid Provisioning. Cutting Deployment Times with INFINIDAT s Host PowerTools. Abstract STORING THE FUTURE

IBM System Storage DS5020 Express

A Kaminario Reference Architecture: Reference Architecture for Running SQL Server on ESXi

Introduction to Virtualization. From NDG In partnership with VMware IT Academy

Surveillance Dell EMC Storage with FLIR Latitude

IBM XIV Provider for Microsoft Windows Volume Shadow Copy Service Version Release Notes

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

EMC Celerra Virtual Provisioned Storage

Method to Establish a High Availability and High Performance Storage Array in a Green Environment

Storage Considerations for VMware vcloud Director. VMware vcloud Director Version 1.0

SolidFire and Pure Storage Architectural Comparison

shaping tomorrow with you Eternus VVOL Matthias Bothe Fujitsu Technology Solutions

All-Flash Storage Solution for SAP HANA:

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

Transcription:

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs Lenovo ThinkSystem DS2200, DS4200, DS6200 June 2017 David Vestal, WW Product Marketing Lenovo.com/systems

Table of Contents Introduction... 3 Large LUNs... 3 Thin Provisioning and Modern File Systems... 5 Rapid RAID Rebuilds... 5 Advantages of Rapid RAID Rebuild... 6 2

Introduction The Lenovo ThinkSystem DS2200, DS4200, and DS6200 SAN products are differentiated offerings with Lenovo s Storage portfolio, providing both hardware and software feature advantages. These SAN products are designed for simplicity, speed, scalability and availability and are the perfect blend of a high performing SAN product with a very easy-to-use interface. With simplicity at its core, the DS2200, DS4200, and DS6200 share the same software features and interface. The Lenovo SAN Manager, the operating software to manage the operational and features of the SAN products, is an easy-to-use GUI that makes complex administrative simple by automating configurations and operations. The Lenovo SAN Manager offers enterpriseclass features like: Storage Tiering & Caching, Thin Provisioning, Rapid RAID Build, Snapshots, and more. In this paper, you will learn: Learn how to create new performance Volumes with Lenovo SAN Manager using the Storage Management Utility or CLI. Understand how Virtual Disk Groups can rebuild parity quickly Large LUNs The Lenovo SAN Manager uses the concept of Virtual Disk Pools which are comprised of multiple Virtual Disk Groups. This now decouples the LUN from being restricted to a single vdisk. A Volume s data on a given LUN can now expand across all disk drives in a pool. When capacity is added to a system, the user is also getting a performance benefit of the additional spindles hence the term Performance Volume. 3

Today s data architectures benefit from large LUNs in several ways; general examples: General Best Practice for VMFS datastores is to use large LUNs for use by multiple VMs. Large LUNs give VMware vsphere users the most flexibility by not requiring storage administrators to provision new storage every time a new VM is created. Large LUNs also minimize rescans for new LUNs on the ESX server, which can impact VMFS I/O. Operating Systems now support up to 16TB file systems. As enterprise workloads for virtual environments grow in size and in performance demands, virtual hard disk (VHD) formats need to accommodate them. Hyper-V in Windows Server 2012 introduces a new version of the VHD format called VHDX which supports virtual disks up to 64TB in size. The Lenovo SAN Manager supports large, flexible Volumes with sizes up to 128TB spanning up to 256 HDDs (architectural limit) providing seamless capacity expansion. Data automatically reflows to new drives and IOPs scales with additional storage. Figure 1- Creating Large Pools and Volumes 4

Thin Provisioning and Modern File Systems Many modern operating systems become automatically aware of an array's ability to support thin provisioning. This is true of Windows 2012 / 2012 R2 and Linux with newer 6.x kernels. When using a non-thin provisioned storage array the deletion of a file does nothing more than rearrange the file system pointers. If the array supports thin provisioning, as with Lenovo SAN Manager, thin-aware operating systems will notify the storage array to free the storage that had been allocated to the file that was deleted. This happens with the SCSI UNMAP command. This will allow for the re-use of the capacity that had been allocated for the deleted file. Windows 2012 / 2012 R2 also issues notifications when the allocations reach a high percentage of the "advertised" capacity. This, along with the capacity usage notifications, signals the user that it may be time to add more physical storage. Rapid RAID Rebuilds Rebuild of conventional (Linear) storage requires that the entire vdisk is rebuilt prior to returning the vdisk (and thus the Volumes on the vdisk) to a fault tolerant state. The rebuild operates at the vdisk level and has no knowledge of Volumes or customer data contained therein. A customer could have a single small Volume on a large vdisk. During the rebuild, even after it has completed the stripes where the Volume resides, the vdisk remains in a degraded or critical state. During this period, another drive failure would take the vdisk from degraded to critical, or from critical to down. In the latter case, the customer may have lost data. In the prior case, the customer s data becomes at risk once again, even though that area of the vdisk had been rebuilt. 5

In another example, the customer may have created a Volume or Volumes consuming the entire vdisk space, but may have actually allocated very little. Since linear storage has no means to know what stripes contain customer data and which do not, that small amount of data will remain at risk until the entire vdisk has been rebuilt. Also, performance suffers during the entire rebuild. Another exposure is encountering a media error. If the array is rebuilding two drives and encounters a media error on a third, the rebuild will fail. This leaves the vdisk in a critical state, exposed, and with no way to rebuild the vdisk. It is especially unfortunate if this media error resides in unallocated space. The outcome is the same, linear storage must assume all stripes contain customer data. Lenovo SAN Manager has a set of technologies to improve these conditions. It enables Virtual Disk Pools which track how much data has been allocated for each Volume and where it resides in the Pool, at a granularity of 4 MB. The Virtual Pool algorithm decides where to allocate each new 4 MB page. With this knowledge, the system is able to rebuild only those stripes containing allocated pages when a RAID rebuild is required. Once these stripes are rebuilt the Virtual Disk Group (and thus all the Volumes in the Pool) are returned to a Fault Tolerant State. This reduces the window of exposure and increases the MTTDL (Mean Time To Data Loss). Advantages of Rapid RAID Rebuild LUNs are spread across many RAID sets. So one RAID set rebuilding only affects a fraction of all disk I/Os. Less rebuild work to do so affected disks can return to full performance quickly. Volumes become fault tolerant more quickly user data is restored to full protection more quickly. 6

The rate of a RAID rebuild is directly proportional to the amount of unused disk space in a Virtual Disk Pool. LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This information could include technical inaccuracies or typographical errors. Changes may be made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any performance data contained herein was determined in a controlled environment; therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems, and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Any references in this publication to non-lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Lenovo, the Lenovo logo, System x, ThinkServer, and ThinkSystem are trademarks of Lenovo in the United States, other countries, or both. 7