English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

Similar documents
SIMATIC. RFID systems User application for RF610M Mobile Reader. Introduction. Description 2. Installing Software 3. Parameterization of the software

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Readme SiVArc V14 SP1 Update 6

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

RF-MANAGER simulator SIMATIC. RFID-Systems RF-MANAGER simulator. Simulating projects. Compact Operating Instructions 06/2010 A5E

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

HawkEye 45T Display User Manual

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

First Steps with S7-PDIAG and ProAgent

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

PD PA AP How To Configure Maxum II TimeServer Access

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

SIMATIC Automation License Manager Manual 02/2008 A5E

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC HMI. WinCC V7.0 SP1 Setting up a Message System. WinCC Alarm Logging 1. Message System in WinCC 2. Principles of the Message System

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

party software COMOS Platform Third-party software Trademarks 1 Requirements for the system environment Third-party software releases Operating Manual

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Key Panels Library SIMATIC HMI. Key Panels Library. Preface 1. Installation of Key Panels Library. Working with the Key Panels Library

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 6 2. Improvements in Update 3 3. Improvements in Update 2 4

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SIMATIC IPC Wizard for. Widescreen devices with multitouch SIMATIC. Industrial PC SIMATIC IPC Wizard for. Preface.

SIMATIC. Process Control System PCS 7 Trend Micro OfficeScan (V8.0; V8.0 SP1) Configuration. Using virus scanners 1.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

Class: DocumentManager 1 COMOS. Platform Class documentation DocumentManager_dll. Programming Manual 03/2017 V10.2.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SIMATIC. Process Control System PCS 7 V7.0 SP1 Security Information Note: Setting up antivirus software. Preface. Using virus scanners 2

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIWAREX U PCS7. Advanced Process Library Version 12/2013

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

Converter SINAMICS G150. Type 6SL37102G

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 2 2. Improvements in Update 1 3

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.


Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Siemens Drives & PLCs

Siemens Drives & PLCs

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3

Transcription:

English SIMATIC Sensors RFID-Systems Getting Started Edition 11/2005; J31069-D0172-U001-A1-7618

Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. Danger indicates that death or severe personal injury will result if proper precautions are not taken. Warning indicates that death or severe personal injury may result if proper precautions are not taken. Caution with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. Caution without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. Notice indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Prescribed Usage Note the following: Warning This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90437 NÜRNBERG GERMANY Edition 11/2005 Copyright Siemens AG 2005. Technical data subject to change

Table of contents 1 Getting Started...1-1 1.1 Introduction... 1-1 1.2 Safety information... 1-1 1.3 Hardware and software requirements... 1-2 1.4 Design of the RF660R reader... 1-3 1.5 Status displays... 1-4 1.6 Connection of hardware components... 1-5 1.7 Installing Software... 1-6 1.8 Parameterizing the RF660R... 1-7 1.9 Testing the R... 1-14 1.10 Documentation and software... 1-15 1.11 Service & support... 1-16 1.12 Contact partner... 1-16 1.13 Training... 1-17 Tables Table 1-1 Order Nos.:... 1-2 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 iii

1 1.1 Introduction This documentation guides you step-by-step to fast initial start-up of the RF660R reader. This includes the following steps: 1. Connecting the HW components of reader, PC and antenna 2. Installing the configuration software for the reader 3. Parameterizing the Reader Preconfigured profile files are provided: 4. Testing the function of the reader (recognizing a tag) 1.2 Safety information Caution Please observe the safety instructions on the back cover of this documentation. SIMATIC RFID products comply with the salient safety specifications to IEC, VDE, EN, UL and CSA. If you have questions about the admissibility of the installation in the designated environment, please contact your service representative. Caution Alterations to the devices are not permitted. Failure to observe this requirement shall constitute a revocation of the radio equipment approval, CE approval and manufacturer's warranty. Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-1

1.3 Hardware and software requirements 1.3 Hardware and software requirements To start up the, you will need the following components: Hardware PC with Windows XP Professional RF660R reader Wide-range power supply unit for SIMATIC RF 24 V connecting cable, 5 m in length At least two RF660A antennas Tags (standards: ISO 18000-6B, EPC Gen. 1 or EPC Gen. 2) RS232 connecting cable from the PC to the reader or TCP-IP cable (crosslink PnP) Two antenna connecting cables Software RF660R configuration software Table 1-1 Order Nos.: Article Order No. RF660R reader 6GT2811-0AA00 RF660A for the European market 6GT2 810-0AA00 RF660A for the American market 6GT2 810-0AA01 RS232 connecting cable, length 10 m 6GT2891-0GN10 Antenna connecting cable, length 10m 6GT2815-0AN10 Wide-range power supply unit for SIMATIC RF 6GT2 898-0AA00 24 V connecting cable, 5 m in length 6GT2 491-1HH50 Antenna mounting kit 6GT2890-0AA00 1-2 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.4 Design of the RF660R reader 1.4 Design of the RF660R reader Item Description No. (1) Status LED (2) Industrial Ethernet (RJ45 connector) (3) RS 422 interface (8-pin M12 connector) (4) RS 232 interface (5-pin M12 connector) (5) Digital I/O (8-pin M12 connector) (6) Power, 24 V DC; (4-pin M12 connector) Description 4 antenna connections ANT 1 to ANT 4 (RTNC connector) Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-3

1.5 Status displays 1.5 Status displays Status displays LEDs Color Meaning Power on Green Power supply ON (also lit for undervoltage/overvoltage) Tag Detect Yellow LED lit, as soon as at least one tag is within the field System Error Red Reader is not active. Rebooting is necessary (operating voltage Off On.) Note If "Tag Detect" is not lit even though a tag is located within the field, common reasons include: Tag protocol has been set incorrectly (can be set with Configuration Software) Tag is defective Reader or antenna has a defect 1-4 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.6 Connection of hardware components 1.6 Connection of hardware components Figure 1-1 Configuration of the Sequence for connecting the HW components Step 1 Connect the RF660R to the PC via a 9-core serial cable (RS 232 connection). Step 2 Connect 2 antennas to connections ANT 1 and ANT 2. Use the antenna cables that can be ordered for RF660R to achieve the optimum transmission conditions. Position the A antennas alongside each other at a spacing of 50 cm and pointing in the same direction. Step 3 Connect the 24 V DC power supply to the RF660R. Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-5

1.7 Installing Software 1.7 Installing Software Installing Java runtime environment and SIMATIC RF660 configuration software 1. Insert the product CD "SIMATIC Sensors - Software & Documentation" in the drive of your parameterization computer. 2. Start by double-clicking 'srf660rinstall.exe' 3. Follow the instructions on your screen until the software has been installed. If you select the "Desktop" option under "Choose shortcut folder" during installation, the RF660R configuration software icon should now be on your deskop. Note Java environment The Java environment from version 1.4.2. required by the RF660R configuration software is contained in 'srf660rinstall.exe'. 1-6 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.8 Parameterizing the RF660R 1.8 Parameterizing the RF660R Step 1 Step 2 Step 3 Connect the RF660R to the power supply. The green POWER LED of the reader is lit. Start the RF660R configuration software. Select the correct country and set: Configure a reader online, using the reader settings. Click Next Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-7

1.8 Parameterizing the RF660R Step 4 Select Connect using Serial Port and the relevant COM interface. Step 5 Step 6 Click Connect. The RF660R configuration software then exchanges message frames with the reader that are shown on your display. The reader can now be parameterized. Acknowledge the successful status message with OK in order to get to the Edith Ethernet and Notify Channel Settings. Select Notify Channel None. Click "Send to Reader and Next". The Notify Channel is the channel on which the tag events are sent. Problems may occur if the firewall is activated. 1-8 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.8 Parameterizing the RF660R Step 7 In the menu Edit Antenna Settings set: Antenna Switching: On, 100ms Number of connected antennas (e.g. antenna 1 and antenna 2): If antennas are not connected: Operating mode: Disabled; Operating mode: TX/RX; for Europe (ETSI): Power 2000 mw; Antenna Gain (dbi): 7.0; Cable Loss (db): 4.0; for the USA, (FCC): Power 1000 mw; Antenna Gain (dbi): 6.0; Cable Loss (db): 4.0 Confirm with Send to Reader. Click Nex to access the Edit Radio Settings menu. Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-9

1.8 Parameterizing the RF660R Step 8 Radio Setting menu. ' Step 9 Select Frequency Hopping ON or OFF (for Europe: ETSI) For the USA (FCC) Frequency Hopping is set as default. Select Send to Reader, click Nex to get to the Edit Tag Protocol Settings menu. 1-10 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.8 Parameterizing the RF660R Step 10 Step 11 Tag Protocol Description Tag Protocol ISO 18000-6 Type B Tags to the ISO 18000-6B radio standard have ISO 18000-6 Type B been detected. EPC CLASS 1 GEN 1 Tags to the EPC Global Class 1 Generation 1 radio standard have been detected. EPC CLASS 1 GEN 1 EPC CLASS 1 GEN 2 Tags to the EPC Global Class 1 Generation 2 EPC CLASS 1 GEN 2 radio standard have been detected. Confirm Send to Reader and click Nex to get to the Edit Trigger Settings menu. Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-11

1.8 Parameterizing the RF660R Step 12 Set in the Edit Trigger Settings menu: Trigger Mode: Continuous. Click Send to Reader and Nex to get to the Edit Reader Mode Settings menu. Confirm Trigger Mode Continuous, confirm with Send to Reader,click Next to get to the Edit Reader Mode Settings menu. 1-12 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.8 Parameterizing the RF660R Step 13 Set in the Edit Reader Mode Settings Operational Mode menu: Autonomous. Click Send to Reader and Next to get to the window Reader Summary. Click Done. The reader is ready. Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-13

1.9 Testing the R 1.9 Testing the R Place a tag on a neutral base (for example, use a base of wood or plastic, but definitely not of metallic or field-influencing materials) in the field lobe of the antenna and switch the reader to "Autonomous Mode". The TAG DETECT LED of the RF660R starts to light up yellow. In order to have the tag ID, ID type, protocol and time stamp of the read tags displayed, click Monitor Tag Events. Alternatively you can also use the following configuration: Mount both antennas on top of each other on a stand, with the first antenna 1 m above the ground, and the 2nd antenna 2 m above the ground (bottom edge of antenna in each case). Hold the tag in the middle between the antennas. 1-14 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.10 Documentation and software 1.10 Documentation and software The following publications and software products are available for the system: Title Contents Source of supply System Manual SIMATIC Function Manual SIMATIC 660R Getting Started SIMATIC Parameterization Manual SIMATIC RF660R Configuring and Operating Manual SIMATIC Containing a description of the hardware components and information needed to plan and configure the system. Description of the XML-interface of the reader (reader protocol) Step-by-step instructions for fast initial start-up of the reader. Contains all the information required for installation and handling of the SIMATIC R configuration software Contains a description of the Data Manager software used for configuring the systems SIMATIC Sensors - Software & Documentation CD Available on the Internet at: http://www.siemens.com/ automation/service&support Manual Collection Available on the Internet at: http://www.siemens.com/ automation/service&support Software Purpose Source of supply Data Manager Configuration of the Visualization of the EPC data received from detected transponders Routing of EPC data to an external interface RF660 configuration software Available on the Internet at: www.siemens.com/simatic-sensors/rf Configuring the RF660R reader SIMATIC Sensors - Software & Documentation CD Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-15

1.11 Service & support 1.11 Service & support Technical Support You can reach the Technical Support for all A&D products Phone: +49 (0) 180 5050 222 Fax: +49 (0) 180 5050 223 Internet Visit our site on the Internet at http://www.siemens.com/automation/service&support You can send a support query to: http://www.siemens.com/automation/support-request You can find the latest general information about our RFID systems on the Internet at: http://www.siemens.com/simatic-sensors/rf The online catalog and the online ordering system is available at: www.siemens.com/automation/mall 1.12 Contact partner If you have any further questions on the use of the products described in this manual, please contact one of our representatives at your local Siemens office. The addresses are found on the following pages: On the Internet at: http://www.siemens.com/automation/partner In catalog CA 01 In Catalog FS 10 specially for factory automation sensors 1-16 Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618

1.13 Training 1.13 Training Training center We offer appropriate courses to get you started. Please contact your regional Training Center, or the central Training Center in D-90327 Nuremberg. Phone: +49 (911) 895-3200 http://www.sitrain.com Getting Started, Edition 11/2005; J31069-D0172-U001-A1-7618 1-17