NOTE Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4).

Similar documents
SBM52/04 Input / Output Module For M-Bus with 99 counters

FBS51/04 Gateway-Module For M-Bus with 6 counters

SBM51/04 Switch cabinet bus module For M-Bus with 32 counters

BMD4032 Input/output module

FBM034 and FBM034W Fieldbus Input Modules

FBM018 and FBM018W Fieldbus Input Modules

FBU410 Input/ Output Modulel

TLD1..TLD4 Duct Temperature Sensors

RCN420-B Room controller

TPC84 Display and Operator Panel

TD11..15, TDF Room Temperature Sensors

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...4 Connection...4 Mounting...5 Maintenance...

DDC110S Room Control Modul With LCD Display

HT12, HTF12 Room humidity/temperature sensor

TPC35 Display and operator panel

IT554 VPN Router IT554. Product Description

RCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description

TPC56 Display and operator panel

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Installation Dimensions...4 Mounting...5 Connection...

RCN200-L Room Controller

TPC70Display and Operator Panel

RCN132-L, RCN132-L-S1 technolon Room Controller

GLT-M002-GLTM GLT-M002-GLTM. Product Description

RBW301-C, RBW302-C, RBW304-C, RBW305-C Room Control Module

GLT-D004-TFA4 Color Ink Jet Printer A4

IT560 VPN router IT560. Commissioning

RCN155-L, RCN151-L Room controller

Commissioning. IT554 VPN Router

DDC4200e Automation Station with Operator Function

BMR410 Controller BMR410. Product Description

BCU070-L technolon Switch Interface. Application. BCU070-L technolon Switch Interface. Product description

DDC420 Automation Station

DDC4200e Controller with Operator Function

RCC200-L Room Controller

Note: Note the changed parameter functions due to firmware updates (see page 5).

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon

SBM51/05 gateway module for Berg network monitoring

GLT2200N BMS Network Operator Station

ROUTER-2SHDSL-RAIL-001/01

BMF400 Input/output module

RBU130-RJ/sw, RBU130-RJ/ws Room Controllers

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return

Contents Notice about the device description...page 2. Device description

Wireless Small Actuator MAC-WSA

Neutrino-GLT Client BACnet TM Protocol Implementation Conformance Statement (PICS) Version 4

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions. Switching amplifier DN0210 DN / / 2015

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

MDM 011-Z1 Regen Resistor

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Product and functional description

Operating instructions. Standstill monitor A / / 2011

Serial PROFIBUS Interface

PNOZ m ES ETH. Configurable Control System PNOZmulti. Operating Manual EN 04

QUINT-BUFFER/24DC/24DC/40

MINI-PS AC/10-15DC/8

Operating instructions. Speed monitor D / / 2014

Access Terminal IF-800

DDC4200 (Firmware ) BACnet Protocol Implementation Conformance Statement (PICS) PICS DDC4200. Date:

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

IF-80x Outdoor Terminal

multisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN

DDC110-L1.. DDC110-L4 technolon Room Module

Operating instructions IO-Link master CabinetLine AL19xx

Expansion module EM-BAC-MOD-01. Installation manual

Type Quickstart (from device Version 2)

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Rotary version, three-position control

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Operating instructions Evaluation system for flow sensors VS / / 2013

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Figure 1: Device components

Type ME43. Quickstart

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Non-communicating room controllers

User Manual. Printer P-52RUE

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

External level devices for conductive point level switch

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Operating Instructions

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Transcription:

Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Switch cabinet bus module with M-Bus input for 32 counters pplication The switch cabinet bus module is used to connect a maximum of 32 counters for external equipment to the DDC3000 or DDC4000 system via M-Bus in accordance with DIN EN 1434-3. Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4). Content Page Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...3 History of the Firmware Versions...4 Connection...5 Mounting...7 Removal...7 Commissioning...8 Displays and Controls...8 Setting the switch cabinet bus address...9 Switching on the Power...10 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - változtatások jogát fenntartjuk - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, 12347 Berlin/Germany Telefon: +49 30 60095-0, Telefax: +49 30 60095-164 www.kieback-peter.de, info@kieback-peter.com

Datasheet 2.50-40.051-31-EN Issue 2014-11-19 Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided. CUTION Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 10

Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Item Switch cabinet bus module with M-Bus input in accordance with DIN EN 1434 3 for a maximum of 32 counters Technical Data Nominal voltage Fuse Display elements and controls Interfaces For device: C 24 V ± 10 % / 230 m; 5.4 V For M-Bus: C 24 V ± 10 % / 100 m; 2.4 V If all connected M-Bus counters require a total power supply of more than 8 standard loads, an additional, electrically isolated power supply is required for the M-Bus. For the definition of a standard load, see the note on page 5. Electronic fuse protection for C 24 V power Four LEDs in housing ddress switch in housing Switch cabinet bus to the DDC system, max. 200 m M-Bus in accordance with DIN EN 1434-3 III 800 V Overvoltage category Rated impulse voltage Level of contamination 2 Method of operation Type 1 Degree of protection IP20 mbient temperature 0..45 C mbient humidity 20..80 % r. h.; non-condensing Installation Switch cabinet installation on TH 35-7.5 top hat rail Dimensions W x H x D mm 125 x 77 x 60 Dimensions 77,0 44,7 125,0 60,0 Page 3 / 10

Datasheet 2.50-40.051-31-EN Issue 2014-11-19 History of the Firmware Versions CUTION Note the changed parameter functions due to firmware updates. You have to reparameterize these functions when updating an older version to the current firmware version. Updating the firmware version of an by replacing the EPROM Devices up Note the firmware version of the existing when performing an update by replacing the to V 5.4 and EPROM. The firmware version of the can be found on the version label on the EPROM from V 5.5 inside the device. Updating an older to a firmware version up to and including 5.4: Use the EPROM/ item to perform the update through replacement of the EPROM. Updating an older to a firmware version of 5.5 and higher: Simply replacing the EPROM is not sufficient; the itself must be replaced. Updating an with firmware version 5.5 to a higher firmware version: Use the EPROM/-01 item to perform the update through replacement of the EPROM. Page 4 / 10

Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Connection WRNING Contact with live parts of electrical domestic installation can cause death due to electric shock. Only connect the device and switch on the power supply if you are qualified to do so. Be sure to comply with VDE guidelines and local wiring regulations. CUTION Switching on the power supply of unparameterized products can lead to unforeseen consequences such as malfunctions or material damage. Switch on the power only after the device has been configured by the commissioning technician. M-Bus DIN EN 1434-3 + _ M-Bus 38 18 39 + 19 M-Bus 40 M1 M0 24 0 _ 24V 0V 24V C 50..60Hz 20 DDC4000 CN1 24V 0V 38 39 40 DDC3000 DDC4000 CN2 Definition of M-Bus standard load: n M-Bus standard load is 1.5 m. For exact data about the load on the bus (standard loads per counter), please see the data sheets for the counters. To ensure fault-free functioning of the M-Bus, do not exceed the maximum number of 8 M-Bus standard loads. Otherwise, you must connect an additional power supply. CUTION If more than 8 M-Bus standard loads are connected, an additional power supply connection is required: C 24 V; 50..60 Hz. This separate power supply must be connected to terminals M1, M0. Page 5 / 10

Datasheet 2.50-40.051-31-EN Issue 2014-11-19 The bus systems of the switch cabinet bus (DDC3000) and the CN bus (DDC4000) are identical. ccordingly, the technical information for the switch cabinet bus also applies to the CN bus. Switch cabinet bus When connecting the switch cabinet bus, use a cable of at least type JY(St)Y 2x2x0.8 Lg: two x two leads stranded into a pair, plastic insulation and an electrostatic shield with a lead diameter of at least 0.8 mm. Use a stranded pair of leads for the data lines (+ and -) and another free lead for the ground (0). t the end of the switch cabinet bus (farthest point from the DDC controller), install a terminating resistor of about 180 ohms between both data lines (+ and -). The terminating resistor is included with the DDC controller The maximum cable length for the switch cabinet bus is 200 m. The DDC3000 / DDC4000 system already includes terminating resistors. M-Bus The m-bus is specified in DIN EN 1434-3. When connecting the m-bus, use a cable of at least type JY(St)Y 1x2x0.8 Lg: two wires, twisted to a pair with plastic insulation and an electrostatic shield with a wire diameter of at least 0.8 mm. Use a stranded pair of wires for the data lines (+ and -). Both wires can be interchanged. The maximum cable length for the M-Bus is 1000 m. The list of supported counters can be found under, FBS51/04 M-Bus connections - Parameter description. Page 6 / 10

Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Mounting WRNING Contact with live parts of electrical domestic installation can cause death due to electric shock. Mounting/removal may only be carried out when power is switched off. CUTION Switching on the power supply of unparameterized products can lead to unforeseen consequences such as malfunctions or material damage. Switch on the power only after the device has been configured by the commissioning technician. TH 35-7.5 1 2 3 4 Removal 1 2 3 4 5 Page 7 / 10

Datasheet 2.50-40.051-31-EN Issue 2014-11-19 Commissioning CUTION Power may only be switched on after the DDC controller and device have been configured by the commissioning technician. Displays and Controls Configuration of the DDC controller is described in the respective project planning documentation. 1 2 3 1 Rotary switch for setting the switch cabinet bus address 2 Switch cabinet bus LED 3 M-Bus LED LED Signal Meaning Switch cabinet bus LED Flashing green Data transmission Switch cabinet bus LED Red Bus error or duplicate address Switch cabinet bus LED Flashing red Incorrect or duplicate address M-Bus LED Flashing green Data transmission M-Bus LED Red M-Bus Off M-Bus LED Flashing red Bus error Page 8 / 10

Issue 2014-11-19 Datasheet 2.50-40.051-31-EN Setting the switch cabinet bus address Disconnect the power supply of the. Press the lower edge of the front cover and remove the cover. The rotary switches for setting the switch cabinet bus address are located inside the. Set the first rotary switch to the first digit of the switch cabinet bus address, and the second rotary switch to the second digit. The example shows the address 15. Permitted range for the switch cabinet bus address: 01 to 16 Insert the front damper along the top edge and lock it in with the bottom edge. 6 0 12 3 4 5 8 9 7 6 0 12 3 4 5 x 10 x 1 Reconnect the power supply of the. Page 9 / 10

Datasheet 2.50-40.051-31-EN Issue 2014-11-19 Switching on the Power WRNING Contact with live parts of electrical domestic installation can cause death due to electric shock. Only connect the device and switch on the power supply if you are qualified to do so. Be sure to comply with VDE guidelines and local wiring regulations. Before switching on the power, ensure that the device has been mounted correctly and check the electrical connection. fter turning on the power, check the transmission function of the. Page 10 / 10