Are all CFD s created equal? Prepared by: Associate Director: Sam Wicks

Similar documents
Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

FOM 2.4 The Performance Indicator: Assessing & Visualizing Data Center Cooling Performance

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

Total Modular Data Centre Solutions

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Catch the Heat Avoid the Heat! How an integrated management approach helps to operate your data center energy efficient and reliable

A LAYMAN S EXPLANATION OF THE ROLE OF IT RACKS IN COOLING YOUR DATA CENTER

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Power Monitoring in the Data Centre: Is the Right Time Now? Jacarta Ltd

CRITICAL INFRASTRUCTURE ASSESSMENTS

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

IBM Integrated Server Farm (ISF)

Overcoming the Challenges of Server Virtualisation

DCIM Data Center Infrastructure Management

Rittal LCP T3+ High-availability IT cooling with no compromise

MEASURE MONITOR UNDERSTAND

APC by Schneider Electric Elite Data Centre Partner

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Predictive Resilience: Leveraging Integrated DCIM to Reduce Data Center Downtime

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Data Center Lifecycle and Energy Efficiency

HPC Solutions in High Density Data Centers

Industry leading low energy evaporative fresh air cooling.

Achieving Optimal Returns from Wellhead Operations

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

siemens.com/dcim We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.

Thermal management. Thermal management

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Data Centre Optimisation Services

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Recapture Capacity for Existing. and Airflow Optimization

Data Center Optimization Services. Maximize Your Data Center

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Data Center Infrastructure Management (DCIM) Demystified

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

6SigmaDCX: Delivering the Fluid Data Center

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

18 th National Award for Excellence in Energy Management. July 27, 2017

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

DCIM Data Center Infrastructure Management Measurement is the first step

WIRELESS ENVIRONMENTAL MONITORS

Taking The Heat Off University of East Anglia Data Centre

Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Product Brochure Eaton 93PR UPS kw

Robert Williams

Liebert. DCL up to 35 kw. Modular Rack Cooling

Liebert. DCL up to 35 kw. Modular Rack Cooling

HPC/Advanced Cooling Track. Rolf Brink/CEO/Asperitas

Virtualization and consolidation

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Optimizing Cooling Performance Of a Data Center

Data Center Infrastructure Management (D.C.I.M.)

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Rittal Cooling Solutions A. Tropp

Partner Introduction

Case Study The University of Warwick

Jack van der Horst, Regional Technology Manager, Asia Pacific. ABB

CyrusOne Case Study About CyrusOne

Tridium - Introduction

QNET-CFD WIKI KNOWLEDGE BASE UNDERLYING FLOW REGIME DOCUMENT TEMPLATE

Introduction to C omputational F luid Dynamics. D. Murrin

Practical Lessons from Data Centre Design and Testing Zac Potts

Over IP Group. Data Centre Infrastructure Management (DCIM)

Comprehensive Data Center Energy Management Solutions

Data Center Optimized Controls

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Data Centre Solutions Expertly Engineered APC Management Software

New Techniques for Energy-Efficient Data Center Cooling

Dominick Lovicott Enterprise Thermal Engineering. One Dell Way One Dell Way Round Rock, Texas

Planning a Green Datacenter

IT S TIME FOR DATA CENTRE SUPPORT

Cooling Solutions & Considerations for High Performance Computers

Server room guide helps energy managers reduce server consumption

Data Centre Air Segregation Efficiency (ASE)

Data Centre In A Box

Precision Cooling. Precision Cooling Advantages

THERMAL MANAGEMENT THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Using Mezzanine Card Assemblies: Power Dissipation & Airflow Evaluation

A separate CRAC Unit plant zone was created between the external façade and the technical space.

Total Building Solutions for Data Centers. The next generation of intelligence. usa.siemens.com/datacenters

McNair Scholars Research Journal

Environmental Data Center Management and Monitoring

Accelerate Your Enterprise Private Cloud Initiative

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

BT Locate Affordable, local, secure data centres

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

Thermal Considerations in Package Stacking and Advanced Module Technology

Introduction to ANSYS CFX

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

DATA CENTRE & COLOCATION

Great Lakes Product Solutions for Cisco Catalyst and Catalyst Switches: ESSAB14D Baffle for Cisco Catalyst 9513 Switch

Next Generation Cooling

Transcription:

Are all CFD s created equal? Prepared by: Associate Director: Sam Wicks samwicks@sudlows.com

Keeping cool under pressure Imagine waking up at 04:00 to an escalated BMS alert that your Dubai data hub has overheated. Over the course of a frantic morning, you learn that a cooling unit developed a fault and shut down, causing a thermal runaway event. You discover that the data centre cooling was under provisioned and IT deployment over the available cooling capacity, which crippled the N+1 resiliency. The result? Total loss of service, contract defaults, fines and the loss of trust from a blue-chip client. This scenario is dreaded by data centre operators. To prevent it, expansion of IT systems and alterations data centre infrastructure must be executed in a manner that identifies, characterises, minimises or prevents risk. This risk is often managed upfront, in the design phase of a new data centre. Cooling systems may be designed with resilience in-mind and capacity carefully managed through DCIM and BMS systems. But as the data centre IT deployment evolves, do you truly know the ability of your cooling system to adequately cool your new blade deployment without impact to resiliency? What will the impact of a cooling unit failure be? Can you afford to take the risk? CFD Modelling Sudlows use Computational Fluid Dynamics (CFD) to put cooling systems through their paces without risk to mission critical infrastructure. We verify cooling effectiveness, resiliency and availability during the audit, design, build and maintenance of critical facilities. Figure 1: CFD in the design of ultra-low PUE fresh air free cooling data centres When CFD modelling is incorporated into the design process there are greater possibilities available to designers. For example, Sudlows have used CFD in the design process of data centres where conventional cooling systems are safely used for higher rack power densities than previously thought best practice, giving greater flexibility to the end user.

It is not just data centre designers that need a way to predict cooling availability to the white space: the same is true for data centre operators and many today are realising that CFD is a valuable tool to guide improvements. With CFD audits and CFD guided decision making, Sudlows have found additional IT capacity needed within a live data centre reaching full capacity, without putting mission critical operations at risk. Why Validation matters Through a thorough non-invasive audit, data centre engineers use CFD to develop a computer model of the facility cooling system, capable of resolving the chaotic cooling airflows commonly found in all air-cooled data centre configurations. For best practice, engineering quantities such as momentum, pressure and heat transfer are translated into easily verifiable quantities including rack inlet temperatures, supply air grille flow rates and BMS sensor readings. The values from the model are validated against the audit data, and the CFD model is shown to be an accurate representation of the data centre. This verification step is crucial. Decisions made taking into account evidence from a non-validated CFD model simply adds further risk to the chain. There are a myriad of methods of CFD analysis available to the engineer, software designer or end user and due to the non-linear nature of the coupled partial differential equations running at the heart of CFD, even slight differences in modelling approach have the potential to produce drastically different results. Figure 2: CFD used to drive improvements and calculate ROI for energy efficiency enhancements Summary To ensure you are not making ill informed decisions, it is important to consider the basis of any CFD simulation.

Understand the scenarios that are being considered are they relevant to day-to-day operations? Is the scenario presented truly a worst case? A data centre cooling system is made up of multiple components, each containing multiple subcomponents. As such, it is crucial that each is treated in a rational way - be sure to consider how each element of the cooling system has been modelled. It is likely that some elements of the cooling system have not been incorporated into the CFD simulation, with assumptions made in place. Ensure that these assumptions are carefully considered. Ideally these will all be considered on your behalf by the CFD engineer: be sure to ask for a copy of validation document which summarise them. Once verified, the CFD model is fit for use and predictive analysis can take place. Any activity, infrastructure change or load scenario that affects the data centre cooling system can be assessed in-line with the facility resiliency goals. We have seen that CFD is a powerful tool with great benefits to data centre designers and operators and many organisations have already benefitted from its use in capacity planning, resiliency gap analyses and audit. With this year gearing up to be the hottest year on record, confidence that your facilities is cooled by a resilient data centre cooling system is needed now more than ever. Catch up with us at Data Centre Dynamics and hear about the latest developments. Figure 3: CFD used to assess maximum cabinet density for an indirect adiabatic freecooling data centre