SIEMENS MAGNETOM Verio syngo MR B15V

Similar documents
SIEMENS MAGNETOM Avanto syngo MR B15

SIEMENS MAGNETOM Avanto syngo MR B15

COBRE Scan Information

SIEMENS MAGNETOM Verio syngo MR B17

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

SIEMENS MAGNETOM Skyra syngo MR D13

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

SIEMENS MAGNETOM TrioTim syngo MR B17

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

Siemens AG, Healthcare Sector. syngo MR D13 0. Supplement - Parameters and image text 0.

SOP: Brain MRI Inital version Gorm Greisen. CONTENT 1.0 Timing of Brain MRI Informed consent...1

SIEMENS MAGNETOM Symphony syngo MR A30

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Philips MRI Protocol Dump Created on Comment Software Stream

ADNI, ADNI_QH, SURVEY. Geometry. connection

Applications Guide for Interleaved

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

MR Advance Techniques. Vascular Imaging. Class III

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

ADNI GO - ADNI 2 Human7 (9) 38:30.1

Orthopedic MRI Protocols. Philips Panorama HFO

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

E. Mark Haacke, PhD. The MRI Institute for Biomedical Research Detroit, Michigan Wayne State University Detroit, Michigan 48201

Dynamic Contrast enhanced MRA

MRI Physics II: Gradients, Imaging

Error! Bookmark not defined. Error! Bookmark not defined.

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

MR-Encephalography (MREG)

M R I Physics Course

syngo MR E11 Operator Manual Ortho Answers for life.

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Short Tutorial for ODIN, the Object-oriented Development Interface for NMR

XI Signal-to-Noise (SNR)

Outline: Contrast-enhanced MRA

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Midterm Review

Scan Acceleration with Rapid Gradient-Echo

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

8/11/2009. Common Areas of Motion Problem. Motion Compensation Techniques and Applications. Type of Motion. What s your problem

Patient Specific. Protocol Identification Number (PID) Must be on each individual. MRI Image

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

A Virtual MR Scanner for Education

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Lucy Phantom MR Grid Evaluation

3-D Gradient Shimming

surface Image reconstruction: 2D Fourier Transform

WE PROVIDE KNOWLEDGE, SERVICES AND PRODUCTS FOR ANY KIND OF PROCESS PLANTS

Breast MRI Accreditation Program Clinical Image Quality Guide

Improved Spatial Localization in 3D MRSI with a Sequence Combining PSF-Choice, EPSI and a Resolution Enhancement Algorithm

New Technology Allows Multiple Image Contrasts in a Single Scan

3D3C & 2D3D Velocity Measurements Using Magnetic Resonance Velocimetry

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Imaging Notes, Part IV

An Introduction to Image Reconstruction, Processing, and their Effects in FMRI

Magnetic Resonance Angiography

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

Head motion in diffusion MRI

Compressed Sensing for Rapid MR Imaging

Basic fmri Design and Analysis. Preprocessing

MAGNETOM C!

MRI Image Quality Assessment

QIBA Profile: Magnetic Resonance Elastography of the Liver

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

Tina Pavlin 12 March 2013

TOF-MRA Using Multi-Oblique-Stack Acquisition (MOSA)

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

Following on from the two previous chapters, which considered the model of the

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

Motion Artifacts and Suppression in MRI At a Glance

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

A Transmission Line Matrix Model for Shielding Effects in Stents

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

MB-EPI PCASL. Release Notes for Version February 2015

Sampling, Ordering, Interleaving

Role of Parallel Imaging in High Field Functional MRI

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

Functional MRI in Clinical Research and Practice Preprocessing

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

SPM8 for Basic and Clinical Investigators. Preprocessing

Higher Degree Total Variation for 3-D Image Recovery

Blipped-Controlled Aliasing in Parallel Imaging for Simultaneous Multislice Echo Planar Imaging With Reduced g-factor Penalty

Sampling, Ordering, Interleaving

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Computational Medical Imaging Analysis

Fmri Spatial Processing

Open file format for MR sequences

Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)

Controlled Aliasing in Parallel Imaging Results in Higher Acceleration (CAIPIRINHA)

University of Cape Town

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Parallel Imaging. Marcin.

SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Exam 8N080 - Introduction MRI

Release Notes. Multi-Band EPI C2P. Release HCP_v1 10 February 2014

Gradient-Echo. Spin-Echo. Echo planar. Assessment of Regional Function Assessment of Global. Parallel Imaging. Function. Steady State Imaging

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Table of Contents MRI Neuro protocols

Transcription:

\\USER\ZAHID_RESEARCH\MS\No Name\3D SWI TA: 6:39 PAT: 2 Voxel size: 1.0 0.5 2.0 mm Rel. SNR: 1.00 SIEMENS: gre Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slab group 1 Slabs 1 Dist. factor 20 % Position R3.8 P2.0 F20.7 Phase enc. dir. 9 Phase oversampling 0 % Slice oversampling 0.0 % Slices per slab 128 FoV read FoV phase 75.0 % Slice thickness 2.00 mm TR 29 ms TE 20.0 ms Averages 1 Concatenations 1 Filter Coil elements HEA;HEP;NE1,2;SP1 Contrast MTC Magn. preparation Flip angle Fat suppr. Water suppr. SWI 15 deg Averaging mode Short term Reconstruction Magn./Phase Measurements 1 Multiple series Each measurement Resolution Base resolution 512 Phase resolution 50 % Slice resolution 100 % Phase partial Fourier Slice partial Fourier Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 24 Accel. factor 3D 1 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Unfiltered images Normalize B1 filter Raw filter Geometry Multi-slice mode Series Interleaved Interleaved Saturation mode Special sat. Standard System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Positioning mode MSMA Sagittal Save uncombined Coil Combine Mode Auto Coil Select FIX H 0 mm S - C - T P >> A Adaptive Combine Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position R3.8 P2.0 F20.7 9 192 mm Physio 1st Signal/Mode Segments 1 Tagging Dark blood Resp. control Inline Subtract Liver registration 1/+

Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Save original images Wash - In Wash - Out TTP PEI MIP - time MapIt Contrasts 1 Sequence Introduction Dimension 3D Elliptical scanning Phase stabilisation Asymmetric echo Bandwidth 120 Hz/Px Flow comp. Yes Allowed delay 0 s RF pulse type Gradient mode Excitation RF spoiling Normal Slab-sel. 2/+

\\USER\ZAHID_RESEARCH\MS\No Name\2D MRV TA: 7:08 PAT: 2 Voxel size: 1.0 0.5 2.5 mm Rel. SNR: 1.00 SIEMENS: fl_tof Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group 1 Slices 128 Dist. factor -33.00 % Position R3.8 P2.0 F20.7 Phase enc. dir. Phase oversampling 0 % FoV read FoV phase 100.0 % Slice thickness 2.5 mm TR 23 ms TE 5.02 ms Averages 1 Concatenations 128 Filter Coil elements HEA;HEP;NE1,2;SP1 Contrast TD MTC Flip angle Fat suppr. Water suppr. 0.000 ms 60 deg Averaging mode Short term Reconstruction Magnitude Measurements 1 Multiple series Each measurement Resolution Base resolution 512 Phase resolution 50 % Phase partial Fourier Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 24 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Normalize B1 filter Raw filter Mode POCS Geometry Multi-slice mode Series Inplane Sequential Ascending Special sat. Gap Thickness System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Tracking F 10 mm 40 mm Positioning mode MSMA Sagittal Save uncombined Coil Combine Mode Auto Coil Select FIX H 0 mm S - C - T P >> A Adaptive Combine Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position R3.8 P2.0 F20.7 216 mm Physio 1st Signal/Mode Dark blood Angio 3/+ Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time

Save original images Sequence Introduction Dimension 2D Asymmetric echo Allowed Contrasts 1 Bandwidth 217 Hz/Px Flow comp. Yes Gradient mode RF spoiling 4/+

\\USER\ZAHID_RESEARCH\MS\No Name\FLOW QUANTIFICATION TA: 1:21 PAT: 2 Voxel size: 0.6 0.6 4.0 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group 1 Slices 1 Dist. factor 20 % Position R3.8 P80.0 F23.2 C > T39.8 Phase enc. dir. Phase oversampling 0 % FoV read FoV phase 100.0 % Slice thickness 4.0 mm TR 42.15 ms TE 4.14 ms Averages 1 Concatenations 1 Filter Distortion Corr.(2D) Coil elements HEA;HEP;NE1,2;SP1 Contrast Flip angle 25 deg Averaging mode Long term Reconstruction Magnitude Measurements 1 Multiple series Resolution Base resolution 448 Phase resolution 100 % Phase partial Fourier Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 24 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Mode Unfiltered images Normalize B1 filter Raw filter Geometry 2D Multi-slice mode Sequential Series Ascending Special sat. System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Positioning mode MSMA Sagittal Coil Combine Mode Auto Coil Select REF H 0 mm S - C - T Sum of Squares Default Shim mode Tune up Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position Isocenter 263 mm Physio 1st Signal/Mode Pulse/Retro Average cycle No Signal ms Calculated phases 30 Segments 3 Arrhythmia detection Angio Flow mode Single dir. Encodings 1 Velocity enc. 50 cm/s Direction Through plane Rephased images Magnitude images Phase images 5/+ Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor

MIP-Tra MIP-Time Save original images Sequence Introduction Asymmetric echo Strong Contrasts 1 Bandwidth 531 Hz/Px Flow comp. No RF pulse type Gradient mode RF spoiling 6/+

\\USER\ZAHID_RESEARCH\MS\No Name\3D MRV (DYNAMIC) TA: 4:18 PAT: 3 Voxel size: 0.9 0.9 0.9 mm Rel. SNR: 1.00 SIEMENS: fl3d_ce Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slab group 1 Slabs 1 Dist. factor 20 % Position L0.0 P15.6 F157.9 C > T6.6 Phase enc. dir. Phase oversampling 0 % Slice oversampling 8.3 % Slices per slab 96 FoV read 340 mm FoV phase 75.0 % Slice thickness 0.90 mm TR 3.41 ms TE 1.27 ms Averages 1 Filter Coil elements HEA;HEP;NE1,2;SP1,2 Contrast Magn. preparation Flip angle Fat suppr. 20 deg Averaging mode Short term Reconstruction Magnitude Measurements 15 Pause after meas. 1 Pause after meas. 2 Pause after meas. 3 Pause after meas. 4 Pause after meas. 5 Pause after meas. 6 Pause after meas. 7 Pause after meas. 8 Pause after meas. 9 Pause after meas. 10 Pause after meas. 11 Pause after meas. 12 Pause after meas. 13 Pause after meas. 14 Multiple series Each measurement Resolution Base resolution 384 Phase resolution 100 % Slice resolution 62 % Phase partial Fourier 6/8 Slice partial Fourier 6/8 Interpolation PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 24 Accel. factor 3D 1 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Normalize B1 filter Raw filter Geometry Multi-slice mode Sequential Series Ascending Special sat. System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Positioning mode MSMA Sagittal Save uncombined Coil Combine Mode Auto Coil Select FIX F 135 mm S - C - T P >> A Adaptive Combine Shim mode Tune up Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position Isocenter 263 mm Physio 1st Signal/Mode Segments 1 7/+

Angio 3D centric reordering Time to center 1.0 s Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Save original images Sequence Introduction Dimension 3D Elliptical scanning Asymmetric echo Allowed Bandwidth 590 Hz/Px Optimization Min. TE TR Allowed delay 0 s RF pulse type Gradient mode Excitation RF spoiling Normal Slab-sel. 8/+

\\USER\ZAHID_RESEARCH\MS\No Name\(HI-RES MRA) TA: 7:10 PAT: 2 Voxel size: 0.6 0.6 0.6 mm Rel. SNR: 1.00 SIEMENS: fl_tof Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slab group 1 Slabs 1 Dist. factor -19.44 % Position R0.7 P11.9 F118.1 C > T5.0 > S-0.2 Phase enc. dir. Phase oversampling 10 % Slice oversampling 22.2 % Slices per slab 144 FoV read 400 mm FoV phase 100.0 % Slice thickness 0.63 mm TR 15 ms TE 3.77 ms Averages 1 Concatenations 1 Filter Coil elements HEA;HEP;NE1,2;SP1,2 Contrast MTC Flip angle Fat suppr. Water suppr. 30 deg Averaging mode Short term Reconstruction Magnitude Measurements 1 Resolution Base resolution 640 Phase resolution 100 % Slice resolution 50 % Phase partial Fourier Slice partial Fourier 7/8 Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Accel. factor 3D 1 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Normalize B1 filter Raw filter POCS Geometry Multi-slice mode Sequential Series Descending Special sat. System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Positioning mode MSMA Sagittal Save uncombined Coil Combine Mode Auto Coil Select REF F 135 mm S - C - T Adaptive Combine Default Shim mode Tune up Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position Isocenter 263 mm Physio 1st Signal/Mode Dark blood Angio TONE ramp 70 % Flow direction 3D centric reordering 9/+ Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag

MIP-Cor MIP-Tra MIP-Time Save original images Sequence Introduction Dimension 3D Elliptical scanning Asymmetric echo Allowed Contrasts 1 Bandwidth 182 Hz/Px Flow comp. Yes Gradient mode RF spoiling 10/+

\\USER\ZAHID_RESEARCH\MS\No Name\fl3_50_coronal_tp_retro_iPAT_.57X.57x4 TA: 1:21 PAT: 2 Voxel size: 0.8 0.8 4.0 mm Rel. SNR: 1.00 SIEMENS: fl_fq_retro Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display AutoAlign Spine Start measurement without further preparation Wait for user to start Start measurements single Routine Slice group 1 Slices 1 Dist. factor 20 % Position L1.0 P15.2 F23.4 Phase enc. dir. Phase oversampling 0 % FoV read FoV phase 100.0 % Slice thickness 4.0 mm TR 42.15 ms TE 4.14 ms Averages 1 Concatenations 1 Filter Distortion Corr.(2D) Coil elements HEA;HEP;NE1,2;SP1,2 Contrast Flip angle 25 deg Averaging mode Long term Reconstruction Magnitude Measurements 1 Multiple series Resolution Base resolution 448 Phase resolution 100 % Phase partial Fourier Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 24 Matrix Coil Mode Auto (Triple) Reference scan mode Integrated Image Filter Distortion Corr. Mode Unfiltered images Normalize B1 filter Raw filter Geometry 2D Multi-slice mode Sequential Series Ascending Special sat. System Body NE2 NE1 HEP HEA SP4 SP2 SP8 SP6 SP3 SP1 SP7 SP5 Positioning mode MSMA Sagittal Coil Combine Mode Auto Coil Select REF H 0 mm S - C - T Sum of Squares Default Shim mode Tune up Adjust with body coil Confirm freq. adjustment Assume Silicone? Ref. amplitude 1H 0.000 V Adjustment Tolerance Auto Adjust volume Position Isocenter 263 mm Physio 1st Signal/Mode Pulse/Retro Average cycle No Signal ms Calculated phases 30 Segments 3 Arrhythmia detection Angio Flow mode Free Encodings 1 Velocity enc. 50 cm/s Direction Rephased images Magnitude images Phase images 11/+ Subtract Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor

MIP-Tra MIP-Time Save original images Sequence Introduction Asymmetric echo Strong Contrasts 1 Bandwidth 531 Hz/Px Flow comp. No RF pulse type Gradient mode RF spoiling 12/+

Table of contents \\USER ZAHID_RESEARCH MS No Name 3D SWI 2D MRV FLOW QUANTIFICATION 3D MRV (DYNAMIC) (HI-RES MRA) fl3_50_coronal_tp_retro_ipat_.57x.57x4 13/-