UNDERCARPET CABLING SYSTEM For Power and Communications

Similar documents
WORK AREA OUTLETS WORK AREA OUTLETS. Work Area Outlets

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

Electrical Components and Equipment for General Use Self Inspection Checklist

Haworth Power Technical Sheets January 2018

SECTION WIRING DEVICES

Power Base AI. Power Base AI. Technical Sheets

Installation Notes TII Model 341 Protector

Fall Test 21 due 12/11/2012

Emery County Senior Center Green River 06/07

SECTION WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Spring Test 9 due 05/11/2013

Spring Test 17 due 06/14/2013

TELEPHONE FLUSH WALL PLATE

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

April 2017 Rev 1

Modular plugs, accessories and tooling

SECTION WIRING DEVICES

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

DS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

The 5400 Series Raceway from The Wiremold

68-HP Floor Box. Universal 3-Gang Design Provides Superior Capacity and Mounting Flexibility

U-SERIES SPECIFICATION GUIDE

Modular plugs, accessories and tooling

SM (SURFACE MOUNTED) WIREWAY: I SERIES

lighting, electrics & communications

MICHIGAN DEPARTMENT OF TRANSPORTATION

SECTION WIRING DEVICES

A Complete Floor Box System for Concrete

920 Remote Control (RC) Switches

for a perfect electrical installation. The range of rail-mounted terminal blocks

This attractive raceway conceals and

Intelligent Channel Bank Shelf

Data sheet C6 A modul 90 jack

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Al uminum Raceway is sleek, clean and

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

DATA-COM DEVICES. Convert any room into a multimedia entertainment studio or home office with ENERLITES Voice, Data, Audio and Video Connectors.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

NT-2300 Series Dual Circuit Track System & Accessories

ASCO 920 Remote Control (RC) Switches

This attractive raceway conceals and

2G Engine Installation

This attractive raceway conceals and

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

[.050 (1.27mm) Density. D-Microminiature]

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements

CableSmart Series Nonmetallic Raceway

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

This Wiremold aluminum raceway system meets the

Cat.6/5e UTP Patch Panels with 45 Jack

CALRAD 70 series - telephone accessories

Ratchet-Pro Slide Cover

Power/Data Instructions. Genius. Movable Walls. September

Electrical Connection Technology. New Items: Autumn 2007

Tarleton State University. Specifications

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Spring Test 5 due 4/26/2013

WIREMOLD Tele-Power Poles

PV Rapid Shutdown device

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

The 5500 Series from The Wiremold Company

Cat.8 Shielded Field Termination Plug Description

SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet

AL4400 Series Isoduct Aluminum Raceway

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Featuring Spectra RMS Breakers

WINSTA. Full Line Catalog 2008/2009

[0.057] 5.8 [0.23]

MODULAR PLUGS, ACCESSORIES AND TOOLING

Solar Combiner Enclosure

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR

EUBIQ GSS POWER TRACK. (GROUNDED SENTRY SHUTTER) system free yourself from fixed power outlets. RH2 Recess Power & Data Housing

Jack Plates. Jack Plates & Accessories PREMIER. PT-625B1 Flush Jack. PREMIER PT-625B3 Flush Jack

ONE GANG WEATHERPROOF OUTLET BOXES - DIE CAST METAL BWF Product Benefits & Features B-5V DB-5V B5-2V. Applications

PanelView Plus/VersaView CE Terminals and Display Modules

TELEPHONE/MODULAR JACK CONNECTORS

Cat.8 Shielded Keystone Jack Description

25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

2.7 UNDER-CARPET WIREWAY

TECHNICAL DATA SHEET DS 16S/DS 16SE. FreeSpace. Loudspeakers. Product Overview. Key Features. Product Information. Applications

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

[0.057] 5.8 [0.23]

FT & RT Test Switches

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

BUSBAR CONNECTIVITY QUICK REFERENCE GUIDE

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Meter Enclosure and Equipment Standards

Description. Green. Red. Orange

Standard Strip Series

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

Standard Products Assembly Equipment Table 3M Electronic Products Division

Power Supply and Fan Module Installation

POKE-THRU FINISHES. Black Painted Flange with Nonmetallic Black Cover. Brass Flange with Nonmetallic Brass Cover. Brass Painted Flange and Cover

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

MICHIGAN DEPARTMENT OF TRANSPORTATION

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

Introduction. The information pages provide standard data common to all D-subminiature connectors. These include:

Transcription:

UNDERCARPET CABLING SYSTEM For Power and Communications Linking Everything Together Power, Voice, and Data December 5, 2007

Undercarpet Cabling System Overview What is Undercarpet Cabling? Primary Applications Features Component List Specifications/Agency Approvals Frequently Asked Questions Installation Example Summary Additional Information and Resources AMP NETCONNECT / page 2 / December 5, 2007

What is Undercarpet Cabling? A low profile, flexible, power and communications cabling system that makes even the most complex office and retail wiring simple, economical, and invisible. All power, voice and data networks can be routed virtually anywhere under the carpet without the restrictions encountered with under floor ducts, walls, partitions and power/data poles. Office equipment and retail fixtures can be handled with ease from desk lamps or fixture lights to computer connections. Easy changes to accommodate new requirements nearly as simply as moving the furniture AMP NETCONNECT / page 3 / December 5, 2007

What is Undercarpet Cabling? Making changes is as easy as 1,2,3 Step 1 = Remove a few sections of carpet squares Step 2 = Change the routing of the Undercarpet Cabling Step 3 = Relocate the floor fittings Presto! You re back in business AMP NETCONNECT / page 4 / December 5, 2007

Primary Applications Where Can Undercarpet Cabling Be Used? Permitted Uses: Branch Circuits Permitted both for general purpose and appliance circuits, and for individual branch circuits. Floors Permitted on level, sound, smooth, continuous floor surfaces made of concrete, ceramic or composition flooring, wood and similar materials. NOT Permitted NOT Permitted Uses: Rough, uneven floor surfaces. Outdoors or in wet locations. Where subject to corrosive materials. In any hazardous (Classified) location. In hospitals, residential buildings or schools. AMP NETCONNECT / page 5 / December 5, 2007

Undercarpet Power System AMP NETCONNECT / page 6 / December 5, 2007

Undercarpet Power System Features U.L. Listed to 300 volt rating 3- and 5-conductor power cable available: 10 AWG (30 amperes) or 12 AWG (20 amperes) Standard Ground or Isolated Ground 0.010 steel protective top shield 15A and 15/20A Direct Connecting Receptacles (DCR) available: 15/20A NEMA 15R/20R receptacles 15A CSA standard single rating, 15 amp Standard Ground or Isolated Ground Sliding receptacle plug opening covers Low-profile floor fittings available Flush floor boxes available Easily interfaced to building wiring Suitable for slab-on-grade applications Meets 2005 NEC Article 324 Meets 2006 CEC Rule 12-800 AMP NETCONNECT / page 7 / December 5, 2007

Undercarpet Power System Typical Layout & Component Overview AMP NETCONNECT / page 8 / December 5, 2007

Undercarpet Power System Component List Transition box (flush wall, surface wall, flush floor, surface floor, or floor duct) Transition block Flat Conductor Cable (FCC) Floor preparation Top shield Top shield bonding clips Taps & Splice Connectors Insulator Kits (for taps & splices) Tap/Splice hand tool Hold down tape Spray adhesive Low profile floor fittings Direct Connecting Receptacles (DCR) DCR circuit adapters (for 5-conductor applications) AMP NETCONNECT / page 9 / December 5, 2007

Undercarpet Power System Transition Box Typically used to transition from round power supply wiring to Flat Conductor Cable (FCC) Flush Floor Service Box Flush Wall Box Surface Wall Box Floor Duct Fitting AMP NETCONNECT / page 10 / December 5, 2007

Undercarpet Power System Transition Box Accepts Power Transition Block, 3-conductor or 5-conductor Can also be used for wall transition of communications/data cabling system Universal Flush Wall Box Sold separately: 8-32 screw Top Shield Bonding Clip (Part No. 554178-1) Universal Flush Wall Box can be used for Category 5E and Category 6 communications transition also Surface Wall Box Surface Wall Box can be used for Category 5E communications transition also AMP NETCONNECT / page 11 / December 5, 2007

Undercarpet Power System Power Transition Block Transitions from round conductors to flat conductors at the transition fitting Features a plastic block, copper alloy terminals, a zinc plated steel base plate, and screws. A common screwdriver is used to terminate the flat conductors. Uses insulation piercing contacts to penetrate the Flat Conductor Cable for termination no special tools required for termination. Same block accepts 3- or 5-conductor cable. AMP NETCONNECT / page 12 / December 5, 2007

Undercarpet Power System Flat Conductor Cable Available in sizes corresponding to 10 AWG (30A) or 12 AWG (20A) round wire. 3- or 5-conductors available, depending on the load circuit to be serviced. Isolated Ground available on 5-conductor cables. All conductors marked to maintain proper polarity. Insulation between adjacent conductors is perforated so that the conductors may be separated easily without exposing bare copper conductors. Tough vinyl shield is bonded to both sides of the cable: Cushions and protects the cable from abrasion. Vinyl Shields 5-Conductor Polyester Shield Copper Conductors 3-Conductor AMP NETCONNECT / page 13 / December 5, 2007

Undercarpet Power System Tap and Splice Connectors Splice Connectors: Used with 3- and 5-conductor cables 10 AWG or 12 AWG rating Electrically connect conductors across the splice AMP NETCONNECT / page 14 / December 5, 2007

Undercarpet Power System Tap and Splice Connectors Tap Connectors: Used with 3- and 5-conductor cables 10 AWG or 12 AWG rating Main Run Tap Cable Electrically connect conductor on the tap cable to a conductor on the main cable run AMP NETCONNECT / page 15 / December 5, 2007

Undercarpet Power System Tap and Splice Connectors AMP / T&B INTERFACE Interface between AMP Flat Conductor Cable and Thomas & Betts flat cable easily achieved with taps or splices Preferred Approach, Using Tap Connectors Inline Approach, Using Splice Connectors AMP NETCONNECT / page 16 / December 5, 2007

Undercarpet Power System Tap and Splice Connectors AMP / T&B INTERFACE Interface between AMP Flat Conductor Cable and Thomas & Betts flat cable easily achieved Refer to Instruction Sheet #408-3128 for guidance http://www.ampnetconnect.com/documents/eng/408-3128- Instruction_Sheet_(U.S.)-RevA.pdf Finished Installation, Using Splice Approach AMP NETCONNECT / page 17 / December 5, 2007

Undercarpet Power System Direct Connecting Receptacle (DCR) User Interface: The low profile receptacle is terminated directly to the flat conductor cable. Tightening the screws allows the terminal tines to pierce the cable insulation and engage the conductors. The spring loaded receptacle covers are closed (to protect the contacts) until a plug is inserted. AMP NETCONNECT / page 18 / December 5, 2007

Undercarpet Power System Direct Connecting Receptacle (DCR) Power Whip Kit Power Whip Kit can be used to transition from AMPINNERGY Modular Power Distribution to Undercarpet power. Single Duplex Dual Duplex DCR with Adaptor Adapter required for 5- conductor applications Adapter housing Blank side can be used for data AMP NETCONNECT / page 19 / December 5, 2007

Undercarpet Communications System AMP NETCONNECT / page 20 / December 5, 2007

Undercarpet Communications System Features Category 5e and Category 6 System cable and components available Protective cable wings One-step installation Low profile floor fittings Floor fittings accept SL Series and 110Connect Jacks, and ACO inserts Multimedia applications Most of the jacks and inserts that are available in the main catalog can be used with the Undercarpet system Meets 2005 NEC Article 800.179(F) Meets 2006 CEC Rule 60-322 AMP NETCONNECT / page 21 / December 5, 2007

Undercarpet Communications System Typical Layout & Component Overview AMP NETCONNECT / page 22 / December 5, 2007

Undercarpet Communications System Component List Transition box Flush, surface, or floor Transition block Enhanced Category 5E Category 6 (backwardly compatible with Category 5E) Cable Enhanced Category 5E Category 6 Hold down tape Communications floor fitting Multimedia floor fitting Voice/Data jacks or ACO fittings UTP, 4-Pair 110Connect Jack SL Series 110 Connect Jack AMP NETCONNECT / page 23 / December 5, 2007

Undercarpet Communications System Transition Box Transitions from round conductors to flat conductors Universal Flush Wall Box Several box types available: Flush wall box Flush wall box, open frame Flush floor service box Multimedia floor fitting Three or More Cable Runs One or Two Cable Runs AMP NETCONNECT / page 24 / December 5, 2007

Undercarpet Communications System Transition Block Transitions from round conductors to flat conductors. Termination is made with a standard 110Connect impact tool. Transition blocks can be terminated to either T568A or T568B. Category 5E Category 6 transition block is backwardly compatible, allowing it to be used with new or existing Enhanced Category 5E or Category 6 installations that use 22-24 AWG, solid conductors. Category 6 AMP NETCONNECT / page 25 / December 5, 2007

Undercarpet Communications System Multimedia Application SL Series Multimedia Jacks RCA Multimedia Jack For audio and video Uses one pair UTP Cable White, Red, or Yellow SL Series 110Connector Jack Thin profile For data Available with dust cover Universal wiring, T568A or T568B SVGA Assembly Multimedia Floor Fitting AMP NETCONNECT / page 26 / December 5, 2007

Undercarpet Communications System Multimedia Application Example CAT5E Round Cable Transition Block Wall box/cover Multimedia Audio Data Video CAT5E Flat Cable AMP NETCONNECT / page 27 / December 5, 2007

Undercarpet Cabling System Specifications Power Cabling Voltage Rating: Maximum voltage between ungrounded conductors: 300 volts Maximum voltage between ungrounded and grounded conductors: 150 volts Power Cabling Current Rating: 12 AWG rated 20 amperes 10 AWG rated 30 amperes Communications Cabling Voltage Rating: 300 volts AC or DC Communications Cabling Category Performance: Enhanced Category 5E Category 6 AMP NETCONNECT / page 28 / December 5, 2007

Undercarpet Cabling System Approvals Undercarpet Power Cabling meets the following: Complies with 2005 National Electrical Code Article 324 UL Listed Flat Conductor Cable, Type FCC (UL File E73212) FCC Fittings (UL File E73213) Complies with CSA C22.1-06, Canadian Electrical Code, Part I Section 12, Rule 12-800 Certified by Canadian Standards Association Flat Conductor Cable, Type FCC (File 7189) FCC Fittings (File 7189) 15 amp receptacles are standard for Canada installations AMP NETCONNECT / page 29 / December 5, 2007

Undercarpet Cabling System Approvals Undercarpet Communications Cabling meets the following: Complies with 2005 National Electrical Code Article 800.179(F) UL Listed Communications Cable, Type CMUC (UL File E138034) UL 444 Communications Cables Complies with CSA C22.1-06, Canadian Electrical Code, Part I Section 60, Rule 60-320 Certified by Canadian Standards Association Communications Cable, Type CMH (File 60814) FCC Fittings and Modular Jacks (File 7189) CSA C22.2 No. 214-02 Communications Cables AMP NETCONNECT / page 30 / December 5, 2007

Undercarpet Cabling System Frequently Asked Questions Can Undercarpet cabling be used in a hospital? NO per NEC 324.12(4) and CEC 12-806. Can Undercarpet cable be used in an office or computer room within a hospital? NO per NEC 324.12(4) and CEC 12-806. Can Undercarpet cabling be used in damp conditions? YES per NEC 324.10(E), CEC 12-804 and CEC 60-324. Can Undercarpet cabling be used in wet locations? NO per NEC 324-12(1), CEC12-806 and CEC 60-326. Can Undercarpet cabling be installed with rolled goods carpet? NO The system is designed to be used with Carpet Squares only; per NEC 324.1, NEC 324.10(H), CEC 12-808 and CEC 60-324. Can Undercarpet cabling be used with the AMPINNERGY Modular Power Distribution System? YES per NEC 324, NEC 604/605, and CEC 12-800. AMP NETCONNECT / page 31 / December 5, 2007

Undercarpet Cabling System Installation Example 1 2 3 Multimedia Floor Fitting and Dual Duplex DCR 4 5 AMP NETCONNECT / page 32 / December 5, 2007

Undercarpet Cabling System Summary Use on hard, smooth floors where carpet squares will cover the cabling system. Route power, voice and data virtually anywhere under the carpet. Change circuit arrangement with ease. Low-profile floor fittings and flush transition boxes available. Interface with T&B flat conductors with ease. Connect to AMPINNERGY Modular Power Distribution System with ease. Power Ratings 300 volts, 20- and 30-amp cable, 15- and 20-amp receptacles. Data/Communications Category 5E and Category 6 cable and components available. Connect to main catalog twisted-pair jacks with ease. Approved by NEC, UL, and CSA. AMP NETCONNECT / page 33 / December 5, 2007

Undercarpet Cabling System Additional Information and Resources Conforms to 2005 National Electrical Code (NFPA 70), Article 324 and Article 800 UL Listed: File Number E73212 Flat Conductor Cable, Type FCC; E73213 Flat Conductor Cable Fittings; E138034 Communications Cable Conforms to 2006 Canadian Electrical Code, Part I (CSA C22.1-06), Section 12 and Section 60 CSA Certified: File Number 7189 Flat Conductor Cable, Type FCC and Flat Conductor Cable Fittings; File Number 60814 Communications Cable, Type CMH Product Information Center: (800) 522-6752 Customer Service (Pricing Inquiries): (800) 553-0938 Undercarpet Cabling Planning and Installation Manual, #409-5566 Application Specification for Undercarpet, #114-6008 AMP NETCONNECT / page 34 / December 5, 2007