xlogic xlogic is a latest generation Micro-plcs, compact and expandable CPU, replacing mini PLCs, multiple timers, relays and counters etc.

Similar documents
xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

xlogic! CPU Built-in Ethernet

xlogic! CPU with Wi-Fi Micro Automation Ideal solution for wireless Ethernet connectivity: the well-proven logic module now also with Wi-Fi

Jazz-J. Jazz. Features:


Millenium II +: general characteristics

Jazz-J. Jazz. Features:

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

FEATURES DESCRIPTION FEATURES

Compact &Ingenious! Innovative Telemetry Solution! Version:V 1.0. Easy Electronic Co., Ltd

MCX08M2 Programmable controller

VersaMax Micro and Nano Technical Product Presentation

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

Logic Controller Millenium Evo

TM221M16TG controller M IO transistor PNP spring

XBP24-E Base 24 I/O Ethernet PRELIMINARY. General characteristics Part number

Switched Mode Power Supply Operating manual PAP800

TM221M32TK controller M IO transistor PNP

LAUREL ELECTRONICS, INC.

Nanoline Simple controls... fast solutions

Features and Benefits. Certifications

TM221ME16T controller M IO transistor PNP Ethernet

Logic Controller Millenium Evo

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

3.3. Control Relays and Timers

AND COMMUNICATION MODULES

Programmable Relay ZEN V2 Units

TM221CE24T controller M IO transistor PNP Ethernet

SMART PROGRAMMABLE RELAYS

02/11/2015

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

Millenium 3 logic controllers

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

XC Series PLC Hardware Manual

mark150s mark150/485s DDC controllers Summary

TM221ME32TK controller M IO transistor PNP Ethernet

FEATURES DESCRIPTION SPECIFICATIONS

CPU 1214C. Overview. Design. The compact CPU 1214C has:

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

BARTH mini-plcs high performance at credit card size

iologik E1200H Series

TM221ME16T controller M IO transistor PNP Ethernet

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

MULTICHANNEL DATA RECORDERS

V350-T38 V350J-T38.

IMIO100 IMIO105. DDC controllers. Summary

Item SM35-J-T20 SM43-J-T20 SM70-J-T20

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

Expansion modules and accessories

TM221CE40T controller M IO transistor PNP Ethernet

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

Digital Indicator Solutions

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

TM221M16R controller M IO relay

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

8B SLX300 Data Acquisition System

with Backlight Graphic LCD Screen

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM241CE24U controller M IO transistor NPN Ethernet

BMS Steam Station Solutions

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Programmable Controllers CPM1A series and CPM2A series.

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

Vision OPLC. Technical Specifications. V T34 Technical Specifications

General information. Display. Supply voltage

TM200CE24T controller M IO transistor Source+ Ethernet

CALEC energy master The benchmark in energy measurement

RTU32S RTU32S Series Small Compact Utility RTU

Time Counters mini "h", DC Version

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

RTU32S RTU32S Series Small Compact Utility RTU

TM241CE24T controller M IO transistor PNP Ethernet

Samba OPLC SM35-J-T20

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TM241CE24T controller M IO transistor PNP Ethernet

TM241C40U controller M IO transistor NPN

TM241CE40T controller M IO transistor PNP Ethernet

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Analog Voltage Combination Module

IT and Instrumentation for industry. Features. Introduction. Applications

TM241C24T controller M IO transistor PNP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Pico Accessories. Memory Modules. This section provides information on various accessories.

TM221CE40R controller M IO relay Ethernet

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Transcription:

xlogic THE PERFECT ALTERNATIVE TO LOW COST PLCs AND BASIC RELAYS IN THIS BROCHURE: ELC-18 series Standard CPU ELC-18 series Economy CPU ELC-18 series extensions ELC-12 series CPU ELC-12 series extensions ELC SMS Module ELC Ethernet Module Accessories xlogicsoft configuration tool Switch Power Supply xlogic is a latest generation Micro-plcs, compact and expandable CPU, replacing mini PLCs, multiple timers, relays and counters etc. The xlogic perfectly fits in the space between timing relays and low-end PLCs. Each CPU incorporates not only a real-time clock and calendar, but also provides support for optional expansion I/O modules to enhance control and monitoring applications. The xlogic is the ideal solution for relay / PLC replacement, or simple control applications as building and parking lot lighting, access control, watering systems, pump control, ventilation systems, home automation and a wide field of applications demanding low cost to be a primary design issue. xlogic is a product made by Easy Electronic Co.,Ltd

Detachable LCD features...and more! ELC-12 Series Detachable LCD Customizable Start-up page / screen With detachable LCD 4-line, 10-character configurable backlighting display Optional metal mounting plate offers mounting to the rear of the control panel door. Keypanel programming feature optional Modbus RTU protocol supported. Various values / settings and parameters can be viewed and adjusted directly through the HMI display. Various blocks different parameters can be displayed on one screen / page simultaneously Unit Size allows for DIN-rail mounting together with commonly used breakers in building automation applications. Retentive memory capability standard feature on the ELC-12 model. Powerful communication capability(1 RS232 port and 2 RS485 ports) Randomly specify a specific page to display the IO status of the ELC 12 or expansion module attached It s optional for xlogic to act as slave or master in certain Modbus RTU communication network. Ethernet capability available. Alarm page can record and display the exact alarm occurrence time HMI(LCD) separate installation available,e.g. xlogic can be installed inside cabinet and HMI mounted in it s front panel Programmable up to 32 (user defined) screens / pages

Detachable LCD Rugged, low cost model. DIN Rail or Wall mounted. Connect optional Ethernet module. Connect HMI / Operator Panel using Modbus. 2/4 routes High Speed Counting on all DC-type units ELC-12 Series MODEL SUPPLY RTC PWM HSC ELC-12AC-R AC 110~240V 8 Digital 4 Relays No No ELC-12DC-DA-R 4 Digital / Analog+4 Digital 4 Relays No ELC-12DC-DA-TN(PNP) 4 Digital / Analog+4 Digital 4 Transistors(PNP) 2 Ch. ELC- 12DC-DA-TP(NPN) 4 Digital / Analog+4 Digital 4 Transistors (NPN) 2 Ch. GENERAL SPECIFICATIONS Timers : 256 Counters : 256 Function Blocks : 256 Operation temp. : 0-55 Storage :-40-70 Protection : IP20(Non-waterproof) RTC accuracy : MAX ±5S/day RTC time intervals : 256 RTC Backup at 25 C : 72 hours, Li-ion battery (optional) Power-off retentivity : Dimensions : 72*90*68 (Unit, mm) Certificate : CE Installation : DIN rail or screw for installation Expansion capacity : yes Password protection : Mutiple password protection Communication interface : TTL interface, 1 RS232 port & 2 RS485 ports Communication protocol : Modbus RTU It s optional for xlogic to be either slave or master in Modbus network.

ELC-12 Models ELC-12AC-R Rated voltage: AC 110-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz Signal 0: AC 0-40V Signal 1: AC79-240V Input current: < 0.03mA Input current: >0.08mA Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz Signal 0:DC 0-3V Signal 1:DC 8-24V ELC-12DC-DA-R High-speed counting: I7,I8( Max.30k Hz) Analog input Signal: DC 0-10V AI1-AI4 = I1-I4 Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz Email: Info@super-relay.com WWW.SUPER-RELAY.COM

ELC-12 Models ELC-12DC-DA-TN(PNP) Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: I7,I8 (Max.30k Hz) Analog input Signal: DC 0-10V AI1-AI4=I1-I4 Output type: transistor(pnp type) output continuous current max value: MAX.0.3A PWM: 2 channel (Q3,Q4) ELC-12DC-DA-TP(NPN) Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: I7,I8 (Max.30k Hz) Analog input Signal: DC 0-10V AI1-AI4=I1-I4 Output type: transistor(npn type) output continuous current max value: MAX. 0.3A PWM: 2 channel (Q3,Q4) Email: Info@super-relay.com WWW.SUPER-RELAY.COM

Connect to the STANDARD ELC-12 Series CPU Compact, space-saving.. ELC-12 Series Extensions MODEL SUPPLY ELC12-E-8AC-R AC 110~240V 8 Digital 8 Relays ELC12-E-8DC-DA-R 8 Digital 8 Relays ELC12-E-8DC-DA-TN(PNP) 4 Digital / analog 8 Transistors(PNP) ELC-12-E-8DC-DA-TP(NPN) 4 Digital/analog 8 Transistors (NPN) ELC12-E-PT100 3 PT100 ELC12-E-AI(I) 4 (0/4..20 ma) ELC12-E-AQ-V DC15V DC24V 2 (DC 0 10V) ELC12-E-AQ-I DC15V DC24V 2 ( 0 20mA) * ELC12-RS485 * ELC12-ETHERNET-AC AC110V AC240V * ELC12-ETHERNET-DC * : Special expansion module GENERAL SPECIFICATIONS Operation temp. : 0-55 Storage :-40-70 Protection : IP20(Non-waterproof) Dimensions : 64*90*48 (Unit, mm) Certificate : CE Installation : DIN rail or screw for installation

ELC-12 series extensions Connect to the STANDARD ELC-12 Series CPU. ELC12-E-8AC-R AC 110~240V 4 AC Digital 2 Relays (10A) 2 Relays (3A) DIGITAL Signal 0: AC 0-40V Input current: <0.03mA Signal 1: AC79-240V Input current: >0.08mA DIGITAL Output Type: Relay output. Continuous Max. Current Value: Q1 Q2: Max 3A Q3 Q4: Max 10A ELC12-E-8DC-DA-R 4 DC Digital/analog 2 Relays (10A) 2 Relays (3A) DIGITAL Signal 0: DC 0-3V Input current: <1.0mA Signal 1: DC 8-24V Input current: >1.5mA ANALOG Signal: DC 0-10V AI1-AI4=I1-I4 DIGITAL Output Type: Relay output. Continuous Max. Current Value: ELC12-E-8DC-DA-TN(PNP) 4 DC Digital/analog 4 Transistors (0.3A)(PNP) DIGITAL Signal 0: DC 0-3V Input current: <1.0mA Signal 1: DC 8-24V Input current: <1.5mA DIGITAL Output Type: Transistor output. (PNP) Continuous Max. Current Value: Q1 Q4: Max 0.3A ELC12-E-8DC-DA-TP(NPN) 4 Digital / analog 8 Transistors (0.3A)(PNP) DIGITAL Signal 0: DC 0-3V Input current: <1.0mA Signal 1: DC 8-24V Input current: <1.5mA ANALOG Signal: DC 0-10V DIGITAL Output Type: Transistor output. (PNP) Continuous Max. Current Value: Q1 Q4: Max 0.3A ELC12-E-PT100 2 channels Type PT100 12bit or 10bit resolution optional Measuring range -50 to +200 ELC12-RS485 Isolated 485 converter,used to bring out the the terminals of RS485 port built-in ELC-12 series CPU for connection with third party devices. Short connect RT1 and RT2 and a 120R resistor would be connected between A/+ and B/-

ELC-12series extensions Connect to the STANDARD ELC-12 Series CPU. ELC12-E-AI-I ELC12-E-AQ-V E ELC12-E-AQ-I E ANALOG 4 channels Signal: 0/4 20mA DC 24V ANALOG OUTPUT 2 channels Output range: DC 0---10V DC 24V ANALOG OUTPUT 2 channels Output range: 0----20mA ELC12-E-Ethernet-DC ELC12-E-Ethernet-AC Ethernet capability for ELC-12 CPU AC 110-240V Ethernet capability for ELC-12 CPU

Adapt to the STANDARD ELC-12 Series CPU. ELC-12 Series Accessories MODEL ELC12-HMI-DP ELC12-COVER-L ELC12-COVER-CABLE ELC12-HMI-FP ELC12-CB-A ELC12-CB-B ELC-Copier Remark Various values / settings,alarm message and parameters can be viewed and adjusted directly through the HMI Up to 32 screens can be configured by users. Conveniently programming for user in the local field. Instead of ELC12-HMI, reducing your cost and the beautiful LED indicator can show you IO status Connection cable between ELC-12 CPU and Faceplate(ELC12-HMI-FP) Faceplate,it can be put outside of cabinet for observaton and operation when ELC-12 CPU was installed inside A type connection bridge,it is short distance application B type connection bridge, it can be used to remotely connect ELC-12 CPU to its extension units. Copy program from one xlogic CPU to others. GENERAL SPECIFICATIONS Operation temp. : 0-55 Storage :-40-70 Protection : IP20(Non-waterproof) Dimensions : 38*97*110 (unit mm) Certificate : CE Installation : screw for installation

Powerful build-in HMI-display features...and more! ELC-18 Series Customizable Start-up page / screen 4 line, 10 character backlight display With Build in HMI features Optional metal mounting plate offers mounting to the rear of the control panel door. Various values / settings and Modbus RTU protocol supported. parameters can be viewed and adjusted directly through the HMI display. Unit Size allows for DIN-rail mounting together with commonly used breakers in building automation applications. Various blocks different parameters can be displayed on one screen / page simultaneously Programming done as with any regular HMI (not just via key pad as most similar products). Randomly specify a specific page to display the IO status of the ELC 18 Powerful communication capability(1 or expansion module attached RS232 port and 1/2 RS485 ports optional) Remote control, monitoring & alarming via SMS. It s optional for xlogic to act as slave or master in certain Modbus RTU Programmable up to 32 (user communication network. defined) screens / pages Ethernet capability available. Retentive memory capability standard feature on the ELC-18 model.

Connect optional expansion modules. Connect optional SMS / GSM message module. Connect optional Ethernet module. Connect HMI / Operator Panel using Modbus. ELC-18 Series MODEL SUPPLY RTC PWM ELC-18AC-R AC 110~240V 12 Digital 6 Relays No ELC-18DC-D-R 12 Digital 6 Relays No ELC-18DC-D-TN 12 Digital 6 Transistors 2 Ch. ELC-18DC-D-TP 12 Digital 6 Transistors 2 Ch. ELC-18DC-DA-R 8 Digital / Analog + 4 Digital 6 Relays No ELC-18DC-DA-TN 8 Digital / Analog + 4 Digital 6 Transistors 2 Ch. ELC- 18DC-DA-TP 8 Digital / Analog + 4 Digital 6 Transistors 2 Ch. GENERAL SPECIFICATIONS Timers : 256 Counters : 256 Function Blocks : 256 Operation temp. : 0-55 Storage :-40-70 Protection : IP20(Non-waterproof) RTC accuracy : MAX ±5S/day RTC time intervals : 256 RTC Backup at 25 C : 10 hours Power-off retentivity : yes Storage capacity : 128K Dimensions : 95*90*55(Unit:mm) Certificate : CE Installation : DIN rail or screw for installation Expansion capacity: 9 analog PCS modules or up to 31Non-analog modules (ELC-E-16, CAN BUS) Password protection : Mutiple password protection Communication interface : TTL interface, 1 RS232 port & 1/2 RS485 ports Communication protocol : Modbus RTU

ELC-18 Models ELC-18AC-R Rated voltage: AC 100-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz Signal 0: AC 0-40V Signal 1: AC 79-240V Input current: < 0.03mA Input current: >0.08mA Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz ELC-18DC-D-R Signal 0: DC 0-3V Signal 1: DC 8-24V High-speed counting: IB, IC (Max.14k Hz) Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz ELC-18DC-DA-R Signal 0: DC 0-3V Signal 1: DC 8-24V High-speed counting: IB, IC (Max.14k Hz) Email: Info@super-relay.com Analog input Signal: DC 0-10V Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz WWW.SUPER-RELAY.COM

ELC-18 Models ELC-18DC-D-TN Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: IB, IC (Max.14k Hz) Output type: transistor (PNP type) continuous current max value: MAX.0.3A PWM: 2 channels (Q5, Q6) ELC-18DC-DA-TN Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: IB,IC (Max.14k Hz) Analog input Signal: DC 0-10V Output type: transistor (PNP type) continuous current max value: MAX. 0.3A PWM: 2 channels (Q5, Q6) Consult our website For the latest updated information www.xlogic-plc.com Email: Info@super-relay.com WWW.SUPER-RELAY.COM

ELC-18 Models ELC-18DC-D-TP Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: IB, IC (Max.14k Hz) Output type: transistor (NPN type) continuous current max value: MAX.0.3A PWM: 2 channels (Q5, Q6) ELC-18DC-DA-TP Signal 0:DC 0-3V Signal 1:DC 8-24V High-speed counting: IB,IC (Max.14k Hz) Analog input Signal: DC 0-10V Output type: transistor (NPN type) continuous current max value: MAX. 0.3A PWM: 2 channels (Q5, Q6) Consult our website For the latest updated information www.xlogic-plc.com Email: Info@super-relay.com WWW.SUPER-RELAY.COM

Connect optional SMS / GSM message module. Connect HMI / Operator Panel using Modbus. ELC-18 Economy MODEL ELC-18AC-R-E ELC-18DC-D-R-E ELC-18DC-D-TN-E ELC-18DC-D-TP-E ELC-18DC-DA-R-E ELC-18DC-DA-TN-E ELC- 18DC-DA-TP-E SUPPLY AC 110~240V 12 Digital 12 Digital 12 Digital 12 Digital 8 Digital / Analog + 4 Digital 8 Digital / Analog + 4 Digital 8 Digital / Analog + 4 Digital 6 Relays 6 Relays 6 Transistors (PNP) 6 Transistors (NPN) 6 Relays 6 Transistors (PNP) 6 Transistors (NPN) RTC PWM HSC* No No No No No No No No No No No No No No HSC = High Speed Count GENERAL SPECIFICATIONS Timers : 256 Counters : 256 Function Blocks : 256 Operation temp. : 0-55 Storage :-40-70 Protection : IP20 RTC accuracy : MAX ±5S/day RTC time intervals : 256 RTC Backup at 25 C : 10 hours, Li-ion battery(optional) Power-off retentivity : yes Dimensions : 95*90*55(Unit:mm) Certificate : CE Installation : DIN rail or screw for installation Expansion capacity : 31 modules (ELC-E-16, CAN BUS) Password protection : Mutiple password protection Communication interface : TTL interface, 1 RS232 port & 1/2 RS485 ports Communication protocol : Modbus RTU

ELC-18 Models Rated voltage: AC 100-240V AC220V consumption: 3W Main voltage operation range: AC85-256V Allowable main frequency: 47-63Hz ELC-18AC-R-E Signal 0: AC 0-40V Signal 1: AC79-240V Input current: < 0.03mA Input current: >0.08mA Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz ELC-18DC-D-R-E Signal 0: DC 0-3V Signal 1: DC 8-24V Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz ELC-18DC-DA-R-E Signal 0: DC 0-3V Signal 1: DC 8-24V Analog input Signal: DC 0-10V Email: Info@super-relay.com Output type: relay output continuous current max value: MAX. 10A Switch frequency Mechanism: 10Hz Resistor load: 2Hz Inductive load: 0.5Hz WWW.SUPER-RELAY.COM

ELC-18 Models ELC-18DC-D-TP-E Signal 0:DC 0-3V Signal 1:DC 8-24V Output type: transistor (NPN type) continuous current max value: MAX.0.3A ELC-18DC-DA-TP-E Signal 0:DC 0-3V Signal 1:DC 8-24V Analog input Signal: DC 0-10V Output type: transistor (NPN type) continuous current max value: MAX. 0.3A Consult our website For the latest updated information www.xlogic-plc.com Email: Info@super-relay.com WWW.SUPER-RELAY.COM

ELC-18 Models ELC-18DC-D-TN-E Signal 0:DC 0-3V Signal 1:DC 8-24V Output type: transistor (PNP type) continuous current max value: MAX.0.3A ELC-18DC-DA-TN-E Signal 0:DC 0-3V Signal 1:DC 8-24V Analog input Signal: DC 0-10V Output type: transistor (PNP type) continuous current max value: MAX. 0.3A Consult our website For the latest updated information www.xlogic-plc.com Email: Info@super-relay.com WWW.SUPER-RELAY.COM

Connect to the STANDARD ELC-18 Series CPU. Connect up to 31 digital modules. ELC-18 Series Extensions MODEL SUPPLY ELC-E-16AC-R AC 110~240V 8 Digital 8 Relays ELC-E-16DC-D-R 8 Digital 8 Relays ELC-E-16DC-DA-R 2 Digital / Analog+6 Digital 8 Relays ELC-E-16DC-D-TN(PNP) 8 Digital 8 Transistors(PNP) ELC-E-16DC-DA-TN(PNP) 2 Digital / Analog+6 Digital 8 Transistors (NPN) ELC-E-PT100 3 PT100 ELC-E-AI(I) 4 (0/4..20 ma) ELC-E-AQ-V DC15V DC24V 2 (DC 0 10V) * ELC-RS485 * ELC-ETHERNET-AC AC110V AC240V * ELC-ETHERNET-DC * ELC-SMS-D-R 6 Digital& 10 SMS inputs 4 Relays& 10 SMS outputs * : Special expansion module GENERAL SPECIFICATIONS Operation temp. : 0-55 Storage :-40-70 Protection : IP20(Non-waterproof) Dimensions : 72*90*53 (Unit, mm) Certificate : CE Installation : DIN rail or screw for installation

ELC-18series extensions ELC-E-16AC-R AC 110~240V 8 AC Digital 4 Relays (10A) 4 Relays (3A) DIGITAL ELC-E-16DC-D-R 8 DC Digital 4 Relays (10A) 4 Relays (3A) DIGITAL ELC-E-16DC-DA-R 6 DC Digital & 2 Analog / Digital 4 Relays (10A) 4 Relays (3A) DIGITAL Signal 0: AC 0-40V Input current: Signal 0: DC 0-3V Input current: <1.0mA Signal 0: DC 0-3V Input current: <1.0mA <0.03mA Signal 1: DC 8-24V Input current: Signal 1: DC 8-24V Input current: Signal 1: AC79-240V Input current: >1.5mA >1.5mA >0.08mA DIGITAL ANALOG DIGITAL Output Type: Relay output. Signal: DC 0-10V Output Type: Relay output. Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A ELC-E-16DC-D-TN 8 DC Digital 8 Transistors (0.3A)(PNP) DIGITAL Signal 0: DC 0-3V Input current: <1.0mA Signal 1: DC 8-24V Input current: <1.5mA DIGITAL Output Type: Transistor output. (PNP) Continuous Max. Current Value: Q1 Q8: Max 0.3A Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A ELC-E-16DC-DA-TN 6 DC Digital & 2 Analog / Digital 8 Transistors (0.3A)(PNP) DIGITAL Signal 0: DC 0-3V Input current: <1.0mA Signal 1: DC 8-24V Input current: <1.5mA ANALOG Signal: DC 0-10V DIGITAL Output Type: Transistor output. (PNP) Continuous Max. Current Value: Q1 Q8: Max 0.3A DIGITAL Output Type: Relay output. Continuous Max. Current Value: Q1 Q4: Max 3A Q5 Q8: Max 10A ELC-RS485 Conveter from RS485 port(2x8pin) of CPU to 3 channels wiring terminals With Photo isolation Short connect RT1 and RT2 and a 120R resistor would be connected between A/+ and B/-

ELC-18series extensions Connect to the STANDARD ELC-18 Series CPU. Connect up to 9 analogue modules. ELC-E-PT100 ELC-E-AI(I) ELC-E-AQ 3 channels Type PT100 12bit or 10bit resolution optional Measuring range -50 to +200 ANALOG 4 channels Signal: 0/4 20mA DC 24V ANALOG OUTPUT 2 channels Output range: DC 0---10V SMS Module Remote control the ELC-18CPU via SMS. Remote monitoring via SMS messages (Alarms, IO Status, analog values etc). Easy configuration with free of charge xlogicsoft software. ELC-SMS-D-R Incorporating the ELC-SMS-D-R module into a system allows the user full remote monitoring as well as remote control of the application via SMS (Short Message Service) on any GSM phone or PDA. Worldwide availability, low operating cost, easy installation and integration in combination with high reliability makes SMS remote control and monitoring a desirable option in hard to reach, distant or hazardous environments. GSM Network support: The ELC-SMS-D-R is equipped with a Quad-band GSM module offering seamless functionality on 850Mhz, 900Mhz, 1800Mhz, 1900Mhz.

Ethernet Module Cable Modules Add the ELC-Ethernet module and provide Ethernet capability to your xlogic. Two standard communication and configuration interface cables are available: RS232 and USB. ELC-Ethernet-DC module ELC-Ethernet-AC module ELC-RS232 ELC-USB xlogicsoft Free of charge xlogic configuration software. FBD/LAD language programming. Free upgrades for all future software versions. Library with pre-configured function blocks for ultra fast set-up. On-line Monitor & Off-line Simulation Free Personal Tutorials Using the dialog boxes, function block parameter setup and modification is a quick and easy task to complete. Link function blocks to complete your program. Set up as many as 256 function blocks in one circuit program. Use the label tool to write a comment, instruction or help note on the xlogic circuit program screen.

Mini-size, light weight. High efficiency, good reliability. UPS function optional. Remote control function optional. EMI filter condenser. Input frequency:47-63hz. Output voltage stability:± 0.5% DIN rail mounting Switch Power Supply Remote control and UPS function The current of the load can be roughly adjusted(means the maximum protective current of the load,adjusting potentionmeter A). Wide range voltage Effective:>75%. input(110-240vac/140-340vdc). Insulation voltage endurance:>15kv. Ripple voltage tolerance range(85-264vac/120-370vdc). output with the LED Indicator. Output voltage fine adjustment range(-5% -+10%,adjusting potentiometer V) Ripple: 150mVp-p. Have the function of soft-start(to limit the peak current of start and the pressure of the voltage to the components). Have the short circuit and over-load protection(short circuit protection With the remote control function(by the switch control the having and non-having of the output voltage). means miss-connect the output voltage in short, after disconnect, the output will be renew.overload protection:105 % -135% ). With the over heat protection function(the main control CMOS chip stops output when the temperature is beyond 135 and the output will renew automatically when the temperature reduces). With the UPS function. (External-connected battery, provide with the UPS by the power supply and the battery).

Mini-size, light weight. High efficiency, good reliability. UPS function optional. Remote control function optional. Over heat protection function. Switch Power Supply MODEL Output voltage Output current Demensions (L X W X H) Installation Full-range voltage input Waving voltage allowance Input frequency Output voltage stability Ripple Temperature Insulation and breakdown Efficiency ELC-05AS ELC-12AS ELC-24AS ELC-05AL ELC-12AL ELC-24AL 5V 12V 24V 5V 12V 24V 6A 3A 1.5A 10A 6A 3A 71mm x 106mm x65 mm 126mm x 106mm x 65mm Standard 35mm DIN (EN50022-35) 100-240VAC/140-340VDC 85-264VAC/120-370VDC 47-63Hz ±0.5% 150mVp-p -25 -+70 >1.5kV >75% Introduction and Installation Dimensions: The ELC-AS/AL Series Switch Power have many feature: being mini-sized,light weight,high efficiency,good reliability and so on. In special, it has the remote control and UPS fucntion. ELC-AS series: ELC-05AS(5V/6A) ELC-12AS(12V/3A) ELC-24AS(24V/1.5A) 71mm X 106mm X 65mm ELC-AL series: ELC-05AL(5V/10A) ELC-12AL(12V/6A) ELC-24AL(24V/3A) 126mm X 106mm X 65mm