MMLG 01, 02, 03, 04 MMLB01

Similar documents
MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

REYROLLE 2RMLG. Operating Recommendations

satech TSB-14 MAIN FEATURES

MiCOM Agile P99x. Grid Solutions. Testing & Commissioning. Test Block, Multi-finger Test Plug and Single-finger Test Plug. Design Flexibility

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

7XG225-3RMLG Test Block System Answers for infrastructure & cities.

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

SAX / PAX Test Blocks & Probes

Safety Test Switch. Reference Handbook. STS-reference-en v

Installation Instructions

FTS / FTP Test Blocks & Plugs

Extension module for lighting control

FLEX Ex Spring Clamp Terminal Base

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

ITS / STP Test Blocks & Plugs

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Power supply CP-C 24/5.0

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Sockets and accessories for auxiliary relays

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

ArmorPoint I/O Field Potential Distributor, Series A

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Digital ac/dc (24V) Input Module

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

MRT1 Test Unit. Manual MRT1 (Revision A)

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Earth-fault Relay SPAJ 110 C. Product Guide

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Power supply CP-C 24/5.0

Universal Power Supplies

SoundwebTM. Installation Guide

Electronic timer CT-ARS.11

Redundancy unit CP-A RU

CompactLogix Power Supplies Specifications

Model Number Structure

TU531, TU532 Terminal Unit

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

Installation Instructions

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Features. Applications and Benefits TRC ELECTRONICS, INC

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Electronic timer CT-ERD.12

Module 18plus. Description. 18plus

3RV1 Circuit-Breakers

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Embedded I/O Expansion Board with 10 Outputs

VIBRATION MONITOR CX-RLY

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Electronic timer CT-ERS.21

Electronic timer CT-AHD.22

1756 ControlLogix Chassis Specifications

PAT-Cal 2 TECHNICAL MANUAL

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Thermal-Magnetic Circuit Breaker 2216-S

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

INJ-24A Series Quick Installation Guide

PTo 150/ DIM HCI 150 W, HQI 150, NAV 150 W, and other similar commercially available 150 W lamps System wattage:

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

Model Number Structure

B60 Domestic Voltage Optimisation Unit

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers

Arc protection relay. Features Three-phase overcurrent function. Application

Power supply CP-E 24/10.0 Primary switch mode power supply

PanelView Plus/VersaView CE Terminals and Display Modules

Solid State Remote Power Controller E

ArmorPoint 24V dc Input Modules, Series A

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Power supply CP-D 12/2.1 Primary switch mode power supply

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Electrical Actuators

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Overview of types. Technical data

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

TF501, TF521 Terminal Bases

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Feeder protection relay SPAA 121 C. Product Guide

Transcription:

MMLG 01, 02, 03, 04 MMLB01 Technical Data Test Blocks and Test Plugs Publication Reference: MMLG_MMLB/EN/TD/B - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

Types MMLG 01, 02, 03, 04 Test Blocks Type MMLB 01 Multi-Finger Test Plug Features Test block can be mounted adjacent to Midos modular relays and systems Test block obviates need to disturb protective system wiring for testing Monitoring, isolation and secondary injection testing are simplified and quickly performed Types Available MMLG 01 Standard test block MMLG 02 Special test block designed for use in busbar protection schemes MMLG 03 Horizontal version of MMLG 01 MMLG 04 Horizontal version of MMLG 02 MMLB 01 Multi-finger test plug Figure 1. MMLG 01 and MMLB 01 terminals 13 and 14 must not be used for CT connections since they may present a safety hazard. Type MMLG 02 Test Block Application Although designed within the Midos range these test blocks offer facilities for monitoring and secondary injection testing any power system protection scheme, when used with the multi- fingered test plug type MMLB 01. Before use, the insulation of the flying leads must be visually checked for damage. The continuity of the shorting plug /wire links, and the state of their insulation, should be checked before insertion into the MMLG 01 test block. Description, Installation and Use The Safety Guide Publication Pxxx-SG-4LM should be read before installing or using the test block (MMLG) or test plug (MMLB). Note. Terminals 13 and 14 have short contact fingers, which must not be used for CT connections. Refer to the Mechanical Details section for a description of the test block (MMLG) and test plug (MMLB). The MMLG cover, when in place, provides protection from electric shock hazard. Care should be taken to ensure that MMLG 01 covers are correctly orientated when replaced. The test block carries 14 circuits, each of which is brought out to separate pairs of terminals at the rear of the case. Each circuit comprises a pair of internal contacts which are normally sprung together to complete the circuit link through the block when the associated protective equipment is in normal service. Access to these internal circuits for testing purposes, can be gained by removing the front cover. A metallic probe secured to the inside face of the MMLG 01 cover is automatically withdrawn when the cover is removed, so interrupting the circuit between terminals 13 and 14. By routing the main dc auxiliary supply to the protection scheme or relay through this circuit, removal of the test block cover will thereby prevent inadvertent tripping of the protection during the ensuing tests. This link is not provided on the MMLG 02 because the contacts between terminals 13 and 14 are normally closed. Note. These two terminals on MMLG 01/02 must not be used for CT connections since this will present a safety hazard. The reason for this is that the associated MMLB 01 test plug contact finger is shorter than the others. This would result in an open circuit path on MMLG 02. Removal of the cover also reveals an orange coloured strip on the block front plate, which gives a clear visual indication that the scheme is out of service. Insertion of the test plug type MMLB 01, as shown in Figures 2 and 3, open circuits the contacts, which connect terminal pairs. The test plug carries 28 4mm sockets. Each socket is identified by a number, which corresponds to the numbered case terminal to which the socket is connected when the plug is inserted. Connections to other equipment, eg., CTs, VTs and dc supplies, should be made to odd numbered terminals on the test block. This ensures that when the test plug MMLB is used, the sockets in the white half of the plug are the isolated relay circuits, and the sockets in the orange half are connected to the potentially live supplies as shown in Figure 6. Figure 2. MMLG 01 test block and multi-finger test plug MMLB 01 (not inserted) with a CT shorting link Note: It is important that the sockets in the MMLB 01 test plug which correspond to current transformer secondary windings are shorted using external links before the test plug is inserted into the MMLG test block. For a typical example, refer to Figure 2. This ensures that current transformer secondary windings are short-circuited before they are disconnected from the protection relay or scheme, thereby avoiding dangerously high voltages. This is illustrated in Figures 2 and 6. If it is desired to use the dc auxiliary supply during testing, then it can be linked across using the sockets in the test plug.

Types MMLG 01, 02, 03, 04 Test Blocks Type MMLB 01 Multi-Finger Test Plug Test equipment can be connected to the relay or scheme using the sockets in the white area of the test plug, and operation of contacts can be monitored. Where more than one MMLG 01 test block is used in the connections to a relay, it may be advisable to route the dc supply through each of them as a safeguard against inadvertent operation. Current withstand MMLG 01/02, MMLB 01 Thermal withstands: 20A continuous, 250A for 1s, 400A for 0.5s. Test cables FJ0865-1 Thermal withstands: 20A continuous 250A for 1s, 400A for 0.5s. Figure 3. MMLG 01 test block with multi-finger test plug MMLB 01 inserted. Technical Data High Voltage Withstand Insulation IEC 60255-27: 2014 MMLG 01/02: 5kV rms for 1 minute between all case terminals connected together and the case earth terminal. Maximum Working Voltage MMLG, MMLB 01 300 volts ac or dc continuous rating Atmospheric Environment Temperature IEC 60255-1: 2009 Storage and transit 25 C to +70 C Operating 25 C to +55 C IEC 60068-2-1: 2007 Cold IEC 60068-2-2: 2007 Dry Heat Humidity IEC 60068-2-78: 2001 56 days at 93% RH and +40 C Enclosure Protection IEC 60529: 1992+A2:2013 MMLG with cover fitted IP50 (dust protected) MMLG (without cover) and MMLB 01 IP20 Figure 5. Test cable with retractable shrouded plugs Mechanical Details Mechanical environment Vibration IEC 60255-21-1: 1988: Response Class 2 EMC compliance 2004/108/EC These products have been classified as electromagnetically benign and are therefore excluded from the European Community EMC Directive (2004/108/EC). Product safety (2006/95/EC) Compliance with the European Commission Low Voltage Directive. EN60255-27: 2014 Compliance is demonstrated by reference to generic safety standards. 2kV rms for 1 minute between any contact pair and either adjacent contact pair. 5kV rms for 1 minute between any alternate contact pair, provided that the intermediate contact pair is not used. MMLG 01 only 1kV rms for 1 minute between terminals 13 and 14 when the cover is removed (eg., opening the auxiliary supply or trip circuit). MMLB 01 As MMLG 01 plus 2kV rms for 1 minute between incoming and outgoing contacts when inserted. Figure 4. Case outline size 2

Types MMLG 01, 02, 03, 04 Test Blocks Type MMLB 01 Multi-Finger Test Plug Test block type MMLG The MMLG test block is a size 2 unit in the Midos system. Relevant sizes and panel mounting details are given in Figure 4. Each terminal has: 1) A 4mm screw outlet for L shaped preinsulated crimp terminations. 2) Two blades (4.8mm x 0.8mm crosssection) to accept snap-on connectors as defined in BS 5057. Any combination of two of the above types of connections may be used on each terminal position. An earth connection should be made to the protective earth terminal on the rear of the MMLG using 2.5mm2 minimum wire. If ring tabs are used for connection to the rear terminal block, these should be of the insulated crimp type to maintain design insulation levels. Multi-fingered test plug type MMLB 01 The test plug locates securely into test sockets of the MMLG test block and can be retained by two knurled screws. Each of the 28 test sockets of the test plug accepts a test cable with 4mm retractable shrouded plugs. Accessories provided with each MMLB 01 test plug: 6 shorting plug links, each comprising two 4mm stackable plugs with retractable shrouds jointed by 150mm length cable. 2m length cables of the same design are available on request. Figure 6. Typical use of MMLG 01 test block and MMLB 01 test plug

Alstom Grid - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom Grid Worldwide Contact Centre www.alstom.com/grid/contactcentre/ Tel: +44 (0) 1785 250 070 www.alstom.com