USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

Similar documents
USB Ranger Fiber Optic USB 2.0 Extender. User Guide

USB 2.0 Ranger High Speed Extender System. User Guide

USB 2.0 Ranger High Speed Extender System. User Guide

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

USB Ranger 110/410 User Guide

USB 2.0 Ranger Port USB m Cat 5e Extender System. User Guide

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

USB Ranger 422 User Guide

EL5200 HDMI + USB 2.0 Extender HDMI and USB m Cat 5e KVM Extender System. User Guide

USB 3.0 Spectra

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

EL5353 DVI + USB 2.0 Extender DVI and USB m CAT 5e/6/7 KVM Extender System. User Guide

KVM - DVI, Audio, USB 2.0, Cat 5 Extender

USB 2.0 Ranger 2324/2344

USB 2.0 RG2304GE-LAN. 4-Port USB 2.0 Gigabit Ethernet LAN Extender System. User Guide

Icron USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

USB 2.0 DIGI-USB2 1-Port USB m Category 5e/6/6a/7 Extender Set with Flexible Power. User Manual. Revision

Icron USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

USB 2.0 CAT5E/6/7 EXTENDER

USB 2.0 RG2304 Network Series

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

USBTHERE User Guide USB100EXT. Featuring ExtremeUSB Technology

USBTHERE User Guide USB110EXT USB120EXT. USB110 EXT shown. Extending the Range of USB

USB 400 FO. EXT-USB-400FON. User Manual

USBTHERE User Guide USB204EXTFIB. Featuring ExtremeUSB Technology

USB 3.1 CAT6A/7 EXTENDER

USB 3 Extenders. 4-Port Point-to-Point Extender System User Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

USB 3.0 SP Port USB m Multimode Fiber Extender System. User Guide

4 Port USB 2.0 Extender over Gigabit Ethernet or Cat5e/6 Cabling - 100m (330ft)

DataPort 250 USB 2.0 Enclosure User s Guide (800)

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

CrystalLink USB2.0 Flex Power

CrystalLink USB 2.0 CAT5 INSTALLATION AND OPERATIONS MANUAL. Part Number CLK-1U4TP-100M/PE Stancliff Road Phone: (281)

Mini USB-2 Extender EXT-USB-MINI2N USER MANUAL

1920x1200 Uncompressed DVI over Cat5e/6 KVM Extender - 330ft (100m)

Mini USB Extender USER MANUAL.

USB 2.0 LR 4-Port Extender

USB 2.0 LR Extender. EXT-USB2.0-LR User Manual.

Logitech Alert 700i/750i System Requirements & Support Guide

User Manual rev: Made in Taiwan

DataPort 350 & 525 USB 2.0 and FireWire Enclosure User s Guide (800)

INSTALLATION AND OPERATIONS MANUAL

Introduction. Package Contents. System Requirements

User Guide. USB/Ethernet Charging Cradle. Mobility Electronics, Inc Via Pasar, San Diego, CA 92126, USA

USB Audio Converter. Installation and Operation Manual. USB to Analog Audio Converter Stancliff Road Houston, Texas 77099

DVI Extra Long Range Extender

USER S MANUAL MODEL VP6630

USB 400 USER MANUAL.

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

INSTALLATION AND OPERATIONS MANUAL

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

FCC Warning. CE Mark Warning. VCCI Mark Warning

SP x4 HDMI 1.3 over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

USER MANUAL Revised August 2, 2011

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

USB Server User Manual

CRU WiebeTech Forensic UltraDock

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

OL-KT. Online Connection Kit Installation Manual

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures.

CRU WiebeTech UltraDock UDv5.5. User Manual. Features

Proliphix EPA-60 Installation Guide

UEH4002A 4-port USB 2.0 CAT 5 Extender User Manual

Thunderbolt 3 Multiport Adapter with Dual HDMI, USB & Gigabit Ethernet. Model

Thunderbolt 3 Multiport Adapter with Dual DisplayPort USB & Gigabit Ethernet. Model

1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output. User Manual

USB-C to VGA Multiport Adapter with Power Delivery. Model

DVI Extra Long Range Extender

Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Macintosh Quick Setup Guide DriveStation

AC4G-D User s Manual

over HDBaseT w/poe, IR & RS-232C

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

CRU WiebeTech Forensic ComboDock

Wi-Fi HDD Docking Station WITH SuperSpeed USB 3.0

HDKVM ELR extension for HDMI and USB Over One CAT5

Bluetooth 4.0 USB Adapter Model

Messager USB w/ Night Answer

Gefen. Extender for HDMI 3DTV GTB-HDMI-3DTV GTB-HDMI-3DTV-BLK. User Manual

User s Manual. Bluetooth Slim Keyboard. Page

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

USB-C5 USB-C5-CE USB EXTENDER Installation and User Guide

DVIKVM Extra Long Range Extender

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

USB2004EXT USB2004EXTGB. Instruction Manual. USB Extender. 4-Port USB 2.0 Extender over Cat5 or Cat6

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

User Manual rev: Made in Taiwan

DX-C USER GUIDE

Drive Side. Host Side. Power. USB Mode Switch

Hi-Speed USB Port Hub Connect up to 4 Hi-Speed USB 2.0 or 1.1 devices

USB22 Series INTRODUCTION INSTALLATION GUIDE

1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232

Bluetooth USB Adapter TALUS. User Guide

Network Adapter. 10/100/1000 Mbps PCI Ethernet Card. Installation Guide ST1000BT32. Actual product may vary from photo

Sonorous v2.0. Installation & User Manual

Quick Installation Guide TU2-700

Transcription:

USB Ranger 2212 Cat 5 USB 2.0 Extender with Remote Power User Guide Powered by

Thank you for purchasing the USB Ranger 2212. Please read this guide thoroughly. This document applies to Part Numbers: 00-00252, 00-00253, 00-00254, and 00-00255. FCC Radio Frequency Interference Statement Warning This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. CE Statement We, Icron Technologies Corporation, declare under our sole responsibility that the Ranger 2212, to which this declaration relates, is in conformity with European Standard EMC EN-55022:2006+A1:2007 Class B, EN 61000-3-2:2006, EN 61000-3-3:2003, and EN 55024:1998+A2:2003. IC Statement This Class B digital apparatus complies with Canadian ICES-003. 2010 Icron Technologies Corporation. All rights reserved. Icron Technologies Corporation, the Icron Technologies Corporation logo, and the Icron Technologies Corporation products referred to herein are either the trademarks or the registered trademarks of Icron Technologies Corporation. All other trademarks are property of their respective owners. Icron Technologies Corporation assumes no responsibility for errors that may appear in this manual. Information contained herein is subject to change without notice. Document #90-00626-A02

Contents Introduction... 3 Ranger Product Contents... 3 Requirements... 3 About the Ranger... 3 Installation guide... 6 Installing the LEX unit... 6 Installing the REX unit... 6 Connecting the LEX unit to the REX unit... 7 Checking the Installation... 7 Connecting a USB Device... 8 Troubleshooting... 8 Specifications... 11 Limited Hardware Warranty... 12 Hardware Remedies... 12 Limitation of Liability... 12 Obtaining Warranty Service... 13 Contacting Technical Support... 13 Technical Glossary... 14

Introduction The instructions in this guide assume a general knowledge of computer installation procedures, familiarity with cabling requirements, and some understanding of USB devices. note NOTE: Notes provide additional information that could be useful. CAUTION: Cautions provide important information about an operational requirement. Ranger 2212 Product Contents Your Ranger 2212 is packaged with: LEX unit (Local Extender) REX unit (Remote Extender) LEX AC power adapter (1) USB Cable (6 ft) Quick Start Guide and Warranty Information note The Ranger 2212 is a unique extender product that provides power over the Cat 5 link from the LEX unit to the REX unit. The system does not require a power adapter at the REX to operate. The provided 24V, 1A power adapter must be connected to the LEX unit for normal operation. Requirements To complete the installation, you will also require the following items that are not included with the product: USB 1.1 or 2.0 compatible computer (host computer) with a USB compliant operating system USB 1.1 or 2.0 compatible device(s) Cat 5 Unshielded Twisted Pair (UTP) cable with two RJ45 connectors (if using surface cabling), OR, Cat 5 cabling with two information outlets and two Cat 5 patch cords with RJ45 connectors (if using premise cabling) note All references to Cat 5 cable in this document represent the minimum requirement. Category 6 or better or STP cable may be substituted. About the Ranger 2212 The Ranger 2212 incorporates Icron s patented ExtremeUSB technology, enabling users to extend beyond the standard 5m cable limit for USB peripheral devices. With the Ranger 2212, USB devices can be located up to 100 meters from the computer. The Ranger is composed of two individual units: the LEX unit and the REX unit. The LEX and REX units may be hot to the touch when operating at or near the high end of the certified temperature range. 3

The LEX unit The LEX unit connects to the computer using the attached USB cable. Power for the system is provided by the 24V AC adapter connected at the LEX unit. The LEX unit delivers power over the Cat 5 extension link to the REX unit. Front View 1 2 3 4 5 Rear View 6 7 8 ITEM TYPE DESCRIPTION 1 Power LED (Blue) LED turns on when power is supplied. Off when no power is supplied. 2 Link LED (Green) 3 Host LED (Green) 4 Activity LED (Amber) 5 Earth Ground 6 Power Indicates a valid ExtremeUSB link is established between the LEX and REX units over the Cat 5 cabling. LED does not blink when in suspend state. Indicates that the Ranger 2212 system is properly enumerated on the host PC. LED blinks when in suspend state. Indicates activity when data transmission is active between LEX and REX. LED blinks intermittently with or without a USB device connected. When the LEX and REX are in suspend mode, the LED is off. Optional earth ground connection to housing of unit. Accepts an M2 type screw. Connects to 24V AC adapter supply. Required for proper operation of the Ranger 2212 system. 7 USB Type B Port Used to connect the LEX unit to the host computer. 8 Link Port (RJ45) Accepts RJ45 connector for Cat 5 cabling (or better). 4

The REX Unit The REX unit provides USB Type A ports for standard USB devices. The REX unit allows you to connect up to two USB devices directly. Additional devices may be connected by attaching USB hubs to the REX unit up to a maximum of 14 USB devices or 3 USB hubs with 11 USB devices. The REX unit is powered via the Cat 5 link extension cable from the LEX unit. Each USB port delivers 500mA of power to the attached USB device(s). Front View 1 1 7 2 3 4 5 6 Rear View 8 ITEM TYPE DESCRIPTION 1 Device Port (USB Type A) 2 Device LED (Green/Orange) Accepts USB device(s). Indicates when a USB device is connected to the Device Port. Solid green when device is plugged in and active. Off when device is in suspend mode or REX unit is powered off. Orange when the REX unit detects an overcurrent condition and the attached USB device attempts to draw more than the 500mA current. 3 Power LED (Blue) LED turns on when power is supplied to unit via Cat 5 cable from LEX. Off when no power is supplied. 4 Link LED (Green) Indicates a valid ExtremeUSB link is established between the LEX and REX over Cat 5 cabling. LED turns on when link between LEX and REX is established. Off when there is no link between LEX and REX. 5 Host LED (Green) Indicates Ranger 2212 system is properly enumerated on the host PC. LED blinks when in suspend state. 6 Activity LED (Amber) Indicates activity when data transmission is active between LEX and REX. LED blinks intermittently with or without a USB device connected. When the LEX and REX are in suspend mode, the LED is off. 7 Earth Ground Optional earth ground connection to housing of unit. Accepts an M2 type screw. 8 Link Port (RJ45) Accepts RJ45 connector for Cat 5 cabling (or better). 5

Installation guide USB extension up to 100m Cat 5 (or better) cable Before you can install the Ranger 2212, you need to prepare your site: 1. Determine where the computer is to be located and set up the computer. 2. Determine where you want to locate the USB device(s). 3. If you are using surface cabling, the Ranger 2212 supports a maximum distance of 100m. OR If you are using premise cabling, ensure Cat 5 cabling is installed between the two locations, with Cat 5 information outlets located near both the computer and the USB device(s), and the total length, including patch chords is no more than 100m. Installing the LEX unit 1. Place the LEX unit near the computer. 2. Install the supplied USB cable to LEX (Type B Port), and an available USB 2.0/1.1 Type A Port on the computer. 3. Plug the 24V power adapter into a suitable AC outlet. 4. Connect the power adapter to the LEX unit. Use only the AC adapter supplied with the Ranger 2212. Use of substitute adapters may cause permanent damage to the system and will void the warranty. Installing the REX unit 1. Place the REX unit near the USB device(s) in the desired remote location. 6

Connecting the LEX unit to the REX unit note To ensure proper operation, it is recommended that only Cat 5 or better, Unshielded Twisted Pair (UTP) cabling be used to connect the LEX unit to the REX unit. The cabling must have a straight-through conductor configuration with no crossovers and must be terminated with 8 conductor RJ45 connectors at both ends. The combined length of any patch cords using stranded conductors must not exceed 10m. With Surface Cabling 1. Plug one end of the Cat 5 cabling (not included) into the Link port (RJ45) on the LEX unit. 2. Plug the other end of the Cat 5 cabling into the Link port (RJ45) on the REX unit. With Premise Cabling 1. Plug one end of a Cat 5 patch cord (not included) into the Link port (RJ45) on the LEX unit. 2. Plug the other end of the patch cord into the Cat 5 information outlet near the host computer. 3. Plug one end of the second Cat 5 patch cord (not included) into the Link port (RJ45) on the REX unit. 4. Plug the other end of the 2 nd patch cord into the Cat 5 information outlet near the USB device. Checking the Installation 1. On the LEX and REX units, check that the Power, Host, and Link LEDs are on and that the Activity LED is blinking. If the Link LED is permanently off, then the cabling between the LEX and REX unit is not installed properly or is defective. 2. For Windows users (2000, XP, Vista, Windows 7), open Device Manager to confirm that the Ranger 2212 has installed correctly. Expand the entry for Universal Serial Bus controllers by clicking the + sign. If the Ranger 2212 has been installed correctly, you should find it listed as a Generic USB Hub. 3. For Mac OS X users, open the System Profiler to confirm that the Ranger 2212 has installed correctly. In the left hand column under Hardware, select USB and inspect the right hand panel. If the Ranger 2212 has been installed correctly, you should find it listed as a Hub under the USB High-Speed Bus/ USB Bus. 4. If the Ranger 2212 is not detected correctly or fails to detect, please consult the Troubleshooting Guide. note To open System Profiler in OS X: Open the Finder, select Applications, then open the Utilities folder and double click on the System Profiler icon. To open Device Manager in Windows 2000 or XP: Right click My Computer then select: Properties >> Hardware tab >> Device Manager To open Device Manager in Windows Vista or Windows 7: Open the Start menu, right click on Computer then select: Manage >> Device Manager 7

Connecting a USB Device 1. Install any software required to operate the USB device(s). Refer to the documentation for the USB device(s), as required. 2. Connect the USB device to the device port on the REX unit. 3. Check that the device is detected and installed properly in the operating system. Compatibility The Ranger 2212 complies with USB1.1 and USB 2.0 specifications governing the design of USB devices. Icron Technologies Corporation does not, however, guarantee that all USB devices are compatible with the Ranger 2212, as there are a number of different configurations that may impact the operation of USB devices over extended distances. Troubleshooting The following table provides troubleshooting tips. The topics are arranged in the order in which they should be executed in most situations. If you are unable to resolve the problem after following these instructions, please contact technical support for further assistance. PROBLEM CAUSE SOLUTION All LEDs on LEX unit are off. The LEX unit is not receiving power from the LEX AC adapter. 1. Ensure that the AC power adapter is properly connected to the LEX unit. 2. Check that the AC adapter is connected to a live source of electrical power. All LEDs on REX unit are off. The REX unit is not receiving power over the Cat 5 link. 1. Ensure that the Cat 5 cabling from LEX to REX is properly installed. 2. Check that the AC adapter on LEX is connected to the LEX unit and to a live source of electrical power. Check that the LEX power LED is illuminated. Link LEDs on LEX unit and REX unit are off. There is no connection between the LEX unit and REX unit. 1. Ensure Cat 5 cable is connected between the LEX unit and REX unit. Cat 5 or better cable, UTP with a straight through connector and no crossovers, and 8 connector RJ45 connectors are used at both ends. 2. If the Cat 5 cable is defective, connect a short Cat 5 patch cord between the LEX unit and REX unit to determine if the original Cat 5 cable is defective. 8

PROBLEM CAUSE SOLUTION Link LED for RJ45 on LEX unit is on, Host LED on LEX unit is off. The host computer is not powered on. 1. Disconnect all USB devices from the REX unit. 2. Disconnect the LEX unit from the computer. The LEX unit is not connected to the computer. The computer does not support USB hubs. The Ranger is malfunctioning. 3. Disconnect the LEX unit from the AC power adapter. 4. Reconnect the LEX unit to the AC power adapter. 5. Reconnect the LEX unit to the computer. 6. In the Universal Serial Bus controllers section of Device Manager, check that the Ranger 2212 is recognized as a Generic USB Hub. Ranger 2212 units were working but the Host LED on LEX/REX units are suddenly blinking. All LEDs on both the LEX unit and REX unit are on, but the USB device does not operate correctly or is detected as an Unknown Device in the operating system. The REX unit is in suspend mode. The operating system may put the Ranger 2212 in suspend mode when the computer is put into a Suspend/Standby state or when no USB devices are attached. The USB device is malfunctioning. The computer does not recognize the USB device. The application software for the device is not operating. The Ranger 2212 is malfunctioning. 1. Recover/Resume the operating system from Suspend/Standby mode (see your operating system s documentation). 2. Attach a USB device to the Ranger 2212. 1. Disconnect the Ranger 2212 from the computer. 2. Connect the USB device directly to the USB port on the computer. 3. If the device does not operate properly, consult the user documentation for the device. 4. Update your system BIOS, chipset or USB Host controller drivers from your System/Mother board manufacturer s website. 5. If the device operates properly when directly connected to the computer, connect another device (of a different type) to the Ranger. 2212. Connect the Ranger 2212 to the computer. 6. If the second device does not operate, the Ranger 2212 may be malfunctioning. Contact technical support for assistance. 9 7. If the second device does operate properly, the first device may not be compatible with the Ranger 2212.

USB device is attached to REX USB port but REX device LED is off. Device LED is orange and units are no longer functioning. A USB device must have the appropriate driver installed on the computer operating system. Overcurrent condition has occurred because USB device draws more power than can be supplied per USB specification (500mA). 1. Install the required USB device driver on the computer operating system prior to attaching the USB device to the REX unit. Please see your USB device manufacturer s website for details. 1. Power cycle LEX. LED Host and LINK LEDs on LEX/REX units blink intermittently. Firmware mismatch between the LEX and REX. 1. Use a different LEX/REX pair which have the same firmware revision. 2. Upgrade the LEX/REX firmware, contact technical support for assistance. NOTES 10

Frequently Asked Questions Please visit Icron s website for answers to FAQs: http://www.icron.com/products/usb/faq.php Specifications Range USB device support 330 feet (100 meters) over Cat 5e (or better) cable High-speed devices (480 Mb/s) (USB 2.0) Full speed devices (12 Mb/s) (USB 2.0 & 1.1) Low speed devices (1.5 Mb/s) (USB 2.0 & 1.1) USB hub support Any single chain can include up to 3 USB hubs plus one Ranger 2212. USB host support EHCI (USB 2.0) and OHCI/UHCI (USB 1.1) Maximum USB devices supported AC adapter(s) AC adapter connector Power available to USB device at REX unit LEX unit USB connector LEX unit Link connector REX unit Link connector REX unit USB connector LEX unit dimensions REX unit dimensions System shipping weight 14 USB devices or 3 USB hubs with 11 USB devices Input: 100/240 V AC, 50 60 Hz, 600 ma maximum Output: 24V DC, 1A 2.1 mm centre-positive jack 500 ma each port 1 x USB Type B 1 x RJ45 1 x RJ45 2 x USB Type A 3.94 x 2.99 x 1.02 (100 mm x 76 mm x 26 mm) 3.94 x 2.99 x 1.02 (100 mm x 76 mm x 26 mm) 2.2 lbs. (1.0 kg) Operating temperature range 0 C to 50 C Storage temperature range -20 C to 70 C Operating humidity Storage humidity 20% to 80% relative humidity, non-condensing 10% to 90% relative humidity, non-condensing Regulatory testing FCC (Class B), IC (Class B), CE (Class B) ESD rating EMC EN-61000-4-2 4kV Contact, 8kV Air 11

Limited Hardware Warranty Icron Technologies Corporation warrants that any hardware products accompanying this documentation shall be free from significant defects in material and workmanship for a period of one year from the date of purchase. Icron Technologies Corporation s hardware warranty extends to Licensee, its customers, and end users. The Warranty does not include repair of failures caused by: misuse, neglect, accident, modification, operation outside a normal operating environment, failure caused by service of the device by non-authorized servicers, or failure caused by a product for which Icron Technologies Corporation is not responsible. Hardware Remedies Icron Technologies Corporation s entire liability and the Licensee s exclusive remedy for any breach of warranty, shall be, at Icron Technologies Corporation s option, either (a) return of the price paid or (b) repair or replacement of hardware, which will be warranted for the remainder of the original warranty period or 30 days, whichever is longer. These remedies are void if failure of the hardware has resulted from accident, abuse, or misapplication. Limitation of Liability The hardware warranty set forth in this agreement replaces all other warranties. Icron Technologies Corporation expressly disclaims all other merchantability and fitness for a particular purpose and noninfringement of third-party rights with respect to the hardware. Icron Technologies Corporation dealer, agent, or employee is not authorized to make any modification, extension, or addition to this warranty. Under no circumstances will Icron Technologies Corporation, its suppliers or licensors be liable for any costs of procurement or substitute products or services, lost profits, loss of information or data, or any other special, indirect, consequential, or incidental damages arising in any way out of the sale of, use of, or inability to use Icron Technologies Corporation product or service, even if Icron Technologies Corporation, its suppliers or licensors have been advised of the possibility of such damages. In no case shall Icron Technologies Corporation, its suppliers and licensors liability exceed the actual money paid for the products at issue. Since some jurisdictions do not allow the limitation of implied warranties of liability for incidental, consequential, special, or indirect damages, the above limitation may not always apply. The above limitations will not apply in case of personal injury where and to the extent that applicable law requires such liability. 12

Obtaining Warranty Service To obtain warranty service, you must contact Icron Technologies Corporation within the warranty period for a Return Material Authorization (RMA) number. Icron Technologies Corporation will not accept returns without an authorized RMA number. Be sure you have the serial numbers of the LEX unit and REX unit units before calling. Package the product appropriately for safe shipment and mark the RMA number on the outside of the package. The package must be sent prepaid to Icron Technologies Corporation. We recommend that you insure it or send it by a method that provides for tracking of the package. The repaired or replaced item will be shipped to you, at Icron Technologies Corporation s expense, not later than thirty days after Icron Technologies Corporation receives the defective product. Address the returned product to: RMA Coordinator Icron Technologies Corporation 4664 Lougheed Highway, Suite 221 Burnaby, BC V5C 5T5 Canada Contacting Sales Email: sales@icron.com Tel: 604-638-3920 Contacting Technical Support Email: techsupport@icron.com Tel: 604-638-3920 To help us serve you better, please include the following information with your technical support request: Host computer make and model Type of operating system installed (e.g. Windows XP, Mac OS X, Windows 7 etc.) Part number and serial number of both LEX unit and REX unit Make and model of any USB device(s) attached to the Ranger 2212 Description of the installation Description of the problem 13

Technical Glossary Category 5 (Cat 5) Network Cabling Category 5 cable is commonly also referred to as Cat 5. This cabling is available in either solid or stranded twisted pair copper wire variants and as UTP (Unshielded Twisted Pair) or STP (Shielded Twisted Pair). UTP cables are not surrounded by any shielding making them more susceptible to electromagnetic interference (EMI). STP cables include shielding over each individual pair of copper wires and provides better protection against EMI. Category 5 has been superseded by Cat 5e cabling which includes improved data integrety to support high-speed communications. USB Cables USB cables have two distinct connectors. The Type A connector is used to connect the cable from a USB device to the Type A port on a computer or hub. The Type B connector is used to attach the USB cable to a USB device. RJ45 The Registered Jack (RJ) physical interface is what connects the network cabling (Cat 5) to the LEX unit and REX unit. You may use either the T568A scheme (Table 1) or the T568B scheme (Table 2) for cable termination as the Ranger 2212 uses all four pairs of the cable. RJ45 connectors are sometimes also referred to as 8P8C connectors. RJ45 Pin Positioning USB Type A port Table 1 - T568A Wiring USB Type A connector USB Type B port USB Type B connector Table 2 - T568B Wiring PIN PAIR WIRE CABLE COLOR PIN PAIR WIRE CABLE COLOR 1 3 1 WHITE/GREEN 1 2 1 WHITE/ORANGE 2 3 2 GREEN 2 2 2 ORANGE 3 2 1 WHITE/ORANGE 3 3 1 WHITE/GREEN 4 1 2 BLUE 4 1 2 BLUE 5 1 1 WHITE/BLUE 5 1 1 WHITE/BLUE 6 2 2 ORANGE 6 3 2 GREEN 7 4 1 WHITE/BROWN 7 4 1 WHITE/BROWN 8 4 2 BROWN 8 4 2 BROWN Pair 2 Pair 3 Pair 1 Pair 4 Pair 2 Pair 3 Pair 1 Pair 4 1 2 3 4 5 6 7 8 W-G G W-O BL W-BL O W-BR BR 1 2 3 4 5 6 7 8 W-O O W-G B W-BL G W-BR BR 14

Icron Technologies Corporation 4664 Lougheed Highway, Suite 221 Burnaby, BC, V5C 5T5 Canada Tel: 604-638-3920 Fax: 604-638-3930 www.icron.com