SideControl Positioner

Similar documents
Digital electropneumatic positioner

Digital electropneumatic positioner

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital Positioner 8049

Digital electropneumatic Positioner for the integrated mounting on process control valves

Pneumatic Control Unit for the integrated mounting on process valves

Digital electropneumatic positioner

Digital electropneumatic Positioner for the integrated mounting on process control valves

Pneumatic Control/Feedback

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic positioner SideControl

Pneumatic Control/Feedback

Digital electropneumatic Process Controller

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves

Series 3730 Electropneumatic Positioner Type

По вопросам продаж и поддержки обращайтесь:

Series 3730 Type Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner

Pneumatic Control/Feedback

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Control head for hygienic process valves

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Digital electropneumatic Positioner for the integrated mounting on process

HERION SERIES Indirect solenoid actuated spool valves

Series 3730 Type Electropneumatic Positioner

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

Control head for decentralized automation of ELEMENT process valves

Installation kits for hygienic process valves

PROFIBUS-PA Positioner Type 3785

Replacement Positioner SideControl Typ 1067

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Series 3730 Electropneumatic Positioner Type with HART communication and pressure sensors

26360, NAMUR. Technical data

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Technical features. 12/ f. N/en

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Series 3730 Electropneumatic Positioner Type and Type with HART communication

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

Operating pressure (bar)

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Material Seat seal. N/en

Electropneumatic Positioner Type and Type with HART communication

Double piston cylinder, Series TWC Ø6-32 mm double-acting with magnetic piston cushioning: elastic

Technical features. N/en

Operating pressure. N/en/en

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Data Sheet T EN

LFC Liquid Flow Controller

24011 series, 3/2 Direct solenoid actuated poppet valve

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Type 8635 SIDE Control Positioner

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Flow. Flow. N/en

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Type 8792, Electropneumatic positioner and process controller. Operating Instructions

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

Series 3730 Type Electropneumatic Positioner

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

NELES ND7000 DIGITAL VALVE CONTROLLER

Electrical Position Transmitter 4-20 ma

Operating pressure. N/en/en

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Electropneumatic positioners SIPART PS2

Electromotive process valve - 2 way angle-seat shut-off valve

Series 95000, 2/2 Direct solenoid actuated poppet valve

General Specifications

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

RT2Y Compact temperature switch intrinsic safety

Technical description

SRD Z Intelligent Positioner stainless steel (316L)

Electropneumatic positioners SIPART PS2

Transcription:

SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC Type 8805 Rotary actuator The SideControl Positioner is an electropneumatic positioner for pneumatically actuated process valves with linear or partturn actuators. It is excuted in two conductor technology. Signal processing, control and actuation of the internal positioning system are accomplished with microprocessor-controlled electronics. The software function Autotune implemented therein enables automatic adaptation of the positioner to the control valve in use. The positioner is parametrized and operated comfortably via three operating keys and a plain-text display. It is possible to set up a decentralized control system if a process controller with PID characteristics is used. As an option, the SideControl Positioner Type 8635 can be supplied with approval for use in the Ex area (Zone 1) to ATEX. Because of its compact and robust design, the housing is suitable for use in chemical and process engineering. Body material Aluminium, hard anodized and plastic coated Other external parts Stainless steel V4A Seal material NBR, Neoprene Control medium neutral gases Processing DIN ISO 8573-1 Dust content Class 5 ( 40 μm particle size) Particle density Class 5 ( 10 mg/m³) Pressure dew point min. 10 under min. operating conditions Oil concentration Class 3 ( 1 mg/m³) Control air -25... +60 C 1) temperature Ambient temperature -25... +60 C 1) Supply pressure 1.4... 6 bar 3) Air flow capacity 2) Control valve Intrinsic air consumption Positioning range Linear actuator Part-turn actuator Position sensor system Operation Electrical connection 55 l/min at 1.4 bar 3) 170 l/min at 6 bar 3) for pressurizing and venting 0 l/min 3... 130 mm 0... 120 High-resolution, conductive plastic, rotary potentiometer Operating keys and plain-text display 2 x M20 x 1.5-bushing Clamping range 6... 12 mm Screw terminals for 0.14... 1.5 mm² 1) Up to +65 C temperature class T4/T5 or without EEx i approval. 2) May be adapted to actuator size with throttle screw. 3) Pressure data in bar; overpressure to ambient. www.burkert.com p. 1/5

(continued) Electrical data Current supply for electronics Burden voltage Setpoint setting via setpoint signal 4... 20 ma < 10.2 V DC 4... 20 ma Control air sockets G 1/4 NPT 1/4; RC 1/4 on request Mounting kits for linear actuator for part-turn actuator Weight Namur recommendation acc. to DIN IEC 534 T6 acc. to VDI/VDE 3845 ca. 1.5 kg Protection class IP65 acc. to EN 60529 Type of ignition protection II (1) 2 G EEx ia IIC T6 acc. to DIN EN 50020 Certication acc. to ATEX 2027 (PTB04) Conformity EMV-89/336/EWG Other electrical data Power Supply Process value input (only for version with process controller) Binary input Analog feedback (Option) Limit switches (Option) (NAMUR initiators) Function values U I 10.2 V 4 ma Permissible maxima as per Certificate of Conformity Ui Ii Pi 30 V 100 ma Burden 10 Ω Ui 30 V Burden voltage U < 200 mv Ii 100 ma Ci 14.3 nf Pi make/break - Co 5.5 μf contact (conf.) Lo 1000 mh U 12... 30 V Uo 30 V I 4... 20 ma Io 100 ma Po U 8 V Uo 15.5 V I uncoated 3 ma Io 52 ma I coated 1 ma Po 150 ma Recommendations for isolation transformers / DC transformers input 4... 20 ma / output 4... 20 ma Company Model Burden Ex active/passive Pepperl+Fuchs KFD2-CD-Ex1.32 850 Ω x A Foxboro Eckardt TV228-S-EGX 700 Ω x A Foxboro Eckardt MT228-S-EGX 750 Ω x A Foxboro Eckardt II949-S1 ZZZ 750 Ω - A Steel 9318/16-22-10 700 Ω x A Steel M318/12-11-00 1000 Ω x A PhoenixContact PI/EX-ID-I/I 800 Ω x A Data given without guarantee of accuracy. For dimensioning and operation of intrinsically safe circuits, the user/owner is responsible. Software functions (depending on the device configuration chosen) Automatic commissioning of control system Parametrization of the positioner Automatic or manual entry of characteristic curve for correction of operating characteristic Setting of the tight-closure or maximum stroke threshold Stroke limitation Limitation of positioning speed Dead band Direction of action of the controller setpoint Signal range splitting (split range up to 4 times) Setting of direction of movement Defintion of a safety position Calibaration of input and display Configuration of binary input Code protection for settings/operation RESET of factory settings p. 2/5

Software functions (depending on the device configuration chosen) Other software functions on Optional built-in process controller (PID) Automatic parametrization of the process controller Setting of the parameters of the process controller Calibration of the setpoint input and display Configuration of the analog input Configuration of the binary input and binary outputs Dimensions [mm] 4 x 45 (=360 ) Ø50 45 32.5 4.5 4 x M6-9 deep 4 x M8-9 deep 40 25 2 x M20 screw fitting 88 46 47 58 23 10 16 93 M6-8 deep M6-8 deep G1/4-12 deep G1/4-12 deep (4.5) 25 74 15.5 ca. 27 ca. 37 47 Ø8 7 165 173.5 Interfaces Binary input Set-point value (4... 20 ma ) Process value input (4... 20 ma) (with process controller only) Supply Inputs SideControl Positioner Operating unit Outputs Initiator 1 Initiator 2 2 binary outputs Analog feedback 4 É 20 ma (position or process value) Note The optional inputs and outputs are shown by dotted lines. p. 3/5

Ordering chart (excerpt, other versions on request) Function 1) Position sensor system Communication Initiator DIN EN 60947-5-6 Analog feedback incl. 2 binary outputs Mounting on pneumatic linear or part-turn actuator EEx approval (acc. to ATEX) Item no. Pos external none no mounting on control valve Type 27XX EEx ia II C T6 150 347 Pos external none yes mounting on control valve Type 27XX EEx ia II C T6 155 369 Pos internal none no NAMUR (DIN IEC 534-6; VDI/VDE 3845) EEx ia II C T6 147 263 Pos internal none 2 open/close no NAMUR (DIN IEC 534-6; VDI/VDE 3845) EEx ia II C T6 * Pos internal none yes NAMUR (DIN IEC 534-6; VDI/VDE 3845) EEx ia II C T6 155 371 Pos internal none 2 open/close yes NAMUR (DIN IEC 534-6; VDI/VDE 3845) none * Pos+Pro external none no mounting on control valve Type 27XX EEx ia II C T6 151 111 Pos+Pro external none yes mounting on control valve Type 27XX EEx ia II C T6 155 373 Pos+Pro internal none no NAMUR (DIN IEC 534-6; VDI/VDE 3845) EEx ia II C T6 147 264 Pos+Pro internal none yes NAMUR (DIN IEC 534-6; VDI/VDE 3845) EEx ia II C T6 155 375 Pos internal none no NAMUR (DIN IEC 534-6; VDI/VDE 3845) none 147 265 Pos external none no mounting on control valve Type 27XX none 147 267 Pos+Pro internal none no NAMUR (DIN IEC 534-6; VDI/VDE 3845) none 147 266 Pos+Pro external none no mounting on control valve Type 27XX none 147 268 1) Pos.: positioner; pro: process controller * available on request is designed for attachment to single-acting actuators. Other options Universal integrated attachment (air channelling without piping) Manometer block VA (inlet air and actuator chamber) Initiators to NAMUR as limit switches (optional) p. 4/5

Ordering chart for accessories Version Item no. Mounting kit for linear actuators to DIN IEC 534-6 787 215 Mounting kit for part turn actuators to VDI/VDE 3845, without bracket 787 338 Console VA VDI/VDE3845-ISO5211 FO5 for attachment to a pneumatic actuator from ball valve, Type 8805 672 243 Manometer block with 2 manometers, VA 654 602 Attachment kit for piston actuators Type 27XX, 80 mm 651 771 Attachment kit for piston actuators Type 27XX, 100 mm/125 mm 651 772 Attachment kit for piston actuators Type 27XX, 175 mm/225 mm 655 567 Position sensor system for piston actuators Type 27XX, 80 mm 651 751 Position sensor system for piston actuators Type 27XX, 100 mm/125 mm 653 021 Position sensor system for piston actuators Type 27XX, 175 mm/225 mm 655 535 Ordering note When attached to a Burkert control valve, the SideControl positioner will be supplied only as part of a complete control valve (positioner, position sensor system, associated attached parts and control valve). To select a suitable control valve, use the data sheets of Types 27XX. To order a complete control valve, state the following numbers: - the order no. of the SideControl positioner - the order no. of the position sensor system, - the order no. of the selected control valve and - the order no. of the accociated attached parts with the remark SideControl positioner control valve. Burkert supplies a completely assembled and tested control valve. To find your nearest Bürkert facility, click on the orange box www.burkert.com If case of special conditions please consult for advice. Subject to alterations. Christian Bürkert GmbH & Co. KG 1301/6_EU-en_00891939 p. 5/5