Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Similar documents
Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Application Description

Product and functional description

Product and functional description

Product and functional description

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Applications Description

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Push Button Interface UP 220D31

Product and functional description

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Push button UP 287, 4 - fold

584 5WG AB_1 DELTA

Product and functional description

Product and functional description

DELTA profil wall switch, single UP 241/2 5WG AB_2

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

DELTA i-system wall switch single UP 221/2 5WG AB_2

Operating and mounting instructions

252F 5WG FB_1 DELTA

Weather station GPS AP 257/61 Weather station AP 257/51

Weather station AP 257/51

Product and Application Description

Product and Function Description

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Operating voltage Maximum

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Digital input modules

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Product and function description

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Operating instructions. Standstill monitor A / / 2011

Selection and Application Guide compelling FLEXIBLE. LCP3000EZ Lighting Control. Global network of innovation

Operating instructions only for authorized, skilled electricians with EIB training

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

Power supply module, bus connection module

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

ABB i-bus KNX BCI/S Boiler/Chiller Interface

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

TXM1.8RB. TX-I/O Blinds module

Line Coupler, MDRC LK/S 3.1, GH Q R0001

TRIO-DIODE/12-24DC/2X10/1X20

Extension module for lighting control

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

Operating Instructions VEGAMET 381

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Operating instructions Evaluation system for flow sensors VS / / 2013

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM84 miniature relays

RM35TF V AC

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

ETD-BL-1T-OFF-CC- 10S

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electrical devices may only be mounted and connected by electrically skilled persons.

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

1-channel shutter actuator 6A UP Installation Instructions

Operating Instructions

Module 18plus. Description. 18plus

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Surface-Mounting Product Ranges

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Rotary version, three-position control

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Super universal modules

PI84 with socket GZM80 interface relays

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Switching module for AC V and up to three load stages, with manual switching

Miniature Circuit Breakers for Railway Applications

Operating instructions. Speed monitor D / / 2014

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

KNX USB INTERFACE UIMtp

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Compact universal controllers

PanelView Plus/VersaView CE Terminals and Display Modules

Transcription:

Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial value of the relation at bus voltage recurrence on/off -delay mode available timer function available allows switching at bus voltage failure allows switching at bus voltage recurrence relay operation mode can be set Example of Operation The load switch N 510/03 is a N-system DIN-rail mounted device. Via its four outputs it can switch four separate groups of electric devices. The power supply of the load switch N 510/03 is provided by the bus (i.e., it requires no additional power supply). The outputs may be operated manually via slide switches. These switches also show the actual switching state (when switching manually as well as when switching via the bus). Each of the outputs (relays) can be assigned various tasks depending on the application program used, i.e. the load switch N 510/03 consists of the device (hardware) and its application programs (software). Appropriate application programs are available for the different tasks the load switch N 510/03 can handle; e.g. for non-delayed on and off switching. With the ETS (EIB Tool Software) the application program is selected, its parameters and addresses are assigned appropriately, and downloaded to the load switch N 510/03. instabus EIB load switch N 510/03 bus coupling unit channel A channel B channel C channel D Installation Instructions load circuit AC 230/400V L1 L2 L3 N 1 L 2 L 3 4 L 5 L 6 7 L 8 L 9 10 L 11 L 12 The device may be used for permanent interior installations in dry locations, within distribution boards, or small casings with DIN rail EN 60715- TH35-7,5. electric loads e.g. fluorescent lamps 2.4.4.7/1

WARNING The device must be mounted and commissioned by an authorised electrician. A safety disconnection of the device must be possible. Especially if the device is connected to different phases. Free DIN rail areas with sticked-in data rail must be covered with covers, order no. 5WG1 192-8AA01. The prevailing safety rules must be heeded. The device must not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Technical Specifications Power supply via bus line Data rail and / or bus connection block Outputs number: 4 (bistable relays, volt free contacts) rated voltage: AC 230 V, 50... 60 Hz rated current: 16 A resistive load switching current at AC 230 V: 0,01 16 A resistive load rated operating current 8A for utilisation categories AC3 in accordance with EN 60947-4-1 switching characteristic: set in parameter list according to application program Control elements 1 learning button: for switching between normal operating mode and addressing mode 4 slide switches for manual operation Display elements 1 red LED: for monitoring bus voltage and displaying mode, selected with the learning button 4 slide switches providing switching state information Connections load circuit, physical: strip insulation for 8... 9 mm permissible conductor types/cross sections: - 0,5... 4 mm² single core - 0,5... 2,5 mm² flexible conductor load circuit, electrical: - plain flexible conductor, min. 1 mm²: current carrying capacity max. 6 A - flexible conductor with terminal pin, crimped on gas tight, min. 1,5 mm²: current carrying capacity max. 10 A - all other conductors, min. 1,5 mm²: current carrying capacity max. 16 A WARNING When looping through the L-conductor (connection blocks 1 and 2, 4 and 5, 7 and 8, 10 and 11) take care that the maximum connection current of 16 A (as governed by the maximum permissible printed conductor load) is not exceeded! bus line - pressure contacts on data rail - screwless bus connection block 0,6...0,8 mm Ø single core remove approx. 5mm of isolation Physical specifications housing: plastic N-system DIN-rail mounted device, width: 4 SUs (1 SU = 18 mm) weight: approx. 240 g fire load: approx. 3200 kj 10 % installation: rapid mounting on DIN rail EN 60715-TH35-7,5. Electrical safety degree of pollution (according to IEC 60664-1): 2 protection (according to EN 60529): IP 20 overvoltage class (according to IEC 60664-1): III bus: safety extra low voltage SELV DC 24 V relay with µ-contact device complies with: EN 50090-2-2 and EN 60669-2-1 Reliability rate of failure: 534 fit at 40 C Technical Manual N 510/03, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.4.4.7/2

Electromagnetic compatibility complies with EN 50081-1, EN 61000-6-2 and EN 50090-2-2 Environmental specifications climatic conditions: EN 50090-2-2 ambient temperature operating: - 5... + 45 C ambient temperature non-op.: - 25... + 70 C relative humidity (non-condensing): 5 % to 93 % Certification EIB certificate CE norm complies with the EMC regulations (residential and functional buildings), and low voltage regulations, Operator Elements A2 A1 A4 Mounting and Wiring The N-system DIN-rail device (4 SUs) can be installed to N-system distribution boards, surface or flush mounted, or to any DIN-rail EN 60715-TH35-7,5 available that has a data rail installed. The connection to the bus line is established by clicking the device onto the DIN-rail (with a data rail installed). Take care that the type plates of all devices on a DINrail can be read in the same direction, guaranteeing the devices are polarised correctly. If the connection is established via bus connection block (data rail not installed) the data rail connection system has to be covered with the enclosed insulation hood after removing the location clip e.g. with a screw driver to guarantee a sufficient insulation from the DIN rail. If the load switch N 510/03 is installed the conventional adapter is not necessary (also for other DIN-rail devices). The bus voltage is downloaded from the bus connection block to the data rail. A B C D A5 Mounting DIN-rail devices (Diagram 2) - Slide the device (B1) onto the DIN-rail (B2) and - swivel back the device until the slide clicks into place audibly. Dismounting DIN-rail devices (Diagram 2) - Remove all connected wires, - press down the slide (C3) with a screw-driver and - swivel the device (C1) from the DIN-rail (C2). A3 B2 C2 Diagram 1: Location of the display and operator elements B1 A1 LED for indicating normal operating mode (LED off) and addressing mode (LED on); upon receiving the physical address the device automatically returns to normal operating mode. A2 Learning button for switching between normal operating mode and addressing mode for receiving the physical address. A3 Screw blocks for connecting load circuits; A4 Screwless bus connection block; A5 Slide switch for manual operation and for displaying the switching position. Slide in upper position: relay contact closed Slide in lower position: relay contact open C1 Diagram 2: Mounting and dismounting a DIN- rail device C3 2.4.4.7/3

Removing the location clip (Diagram 3) - The location clip (D3) surrounds the contact system (D2) on the back side of the load switch N 510/03 (D1). - Insert the screw driver between the DIN-rail device (D1) and the location clip (D3) and remove the location clip. Inserting the insulation top (Diagram 3) - Put the insulation top (D4) onto the contact system and click it into place by a slight pressure. Connecting bus cables (Diagram 4) - The bus connection block () can be used with single core conductors Ø 0,6... 0,8 mm. - Remove approx. 5 mm of insulation from the conductor (.4) and plug it into the bus connection block () (red = +, black = -). Disconnecting bus cables (Diagram 4) Unplug the bus connection block () and remove the bus cable conductor (.4) while simultaneously wiggling it. D3 D1 D2 D2 D4 D1 Diagram 3: Covering the contact system Slipping off bus connection blocks (Diagram 4) - The bus connection block () is situated on the top of the load switch N 510/03(E2). - The bus connection block () consists of two components (.1 and.2) with four terminal contacts each. Take care not to damage the two test sockets (.3) by accidentally connecting them to the bus cable or with the screw-driver (e.g. when attempting to unplug the bus connection block). - Carefully put the screw-driver to the wire-inserting slit of the bus connection block's grey component and pull the bus connection block () from the load switch N 510/03(E2). Note: Don't try to remove the bus connection block from the bottom side! There is a risk of shorting-out the device! Slipping on bus connection blocks (Diagram 4) - Slip the bus connection block onto the guide slot and - press the bus connection block () down to the stop..1.2.3.4 5 mm.4 Diagram 4: Connecting and disconnecting bus wires Connecting load circuits (Diagram 5) - Remove approx. 8 to 9 mm of insulation from the wire (F1.1) and plug it into the terminal (F1) and tighten the screws (F1.2) cross sections load circuit, physical: strip insulation for 9... 10 mm permissible conductor types/cross sections: - 0,5... 4 mm² single core - 0,5... 2,5 mm² flexible conductor E2 Disconnect load circuits (Diagram 5) - Release the screw (G1.2) and remove the wire (G1.1) from the terminal (G1). Technical Manual N 510/03, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.4.4.7/4

F1.1 F1.2 8... 9 mm G1.1 G1.2 F1 G1 Diagram 5: Connecting and disconnecting load circuits General Notes Any faulty devices should be returned to the local Siemens office. If you have further questions about the product, please contact our Technical Support: +49 (0) 180 50 50-222 +49 (0) 180 50 50-223 adsupport@siemens.com Important hint: The manual operation of the sliding switches is only designated as an emergency operation. There is no telegram downloaded to the bus and the changed position is not recognised by the bus controller. In case of bus voltage failure/recurrence even the switching conditions of manually controlled relays resume the condition set in parameter list. Notes Dimension Diagram Dimensions in mm 90 45 b b = 4 TE 44 55 1 Spacer Unit (SU) = 18mm 2.4.4.7/5