ControlFire. Titan Division Presentation

Similar documents
ControlFire. June 2013

DynaSelect System. Plug-n-Perf Optimized

DEEP EXPERIENCE. STRONG REPUTATION.

REDEFINING PUMP DOWN PERFORATING

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

GUIDE TO ASSEMBLY OF ERICA SYNTHS MIDI-CV MODULE

Adapter Kit - Remote QSI Electronics Installation Instructions

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

P9 ASD Simple Start Guide

Intelligent Solar Charge Controller User s Manual. Please read this manual carefully before you use this product

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Long Gun Deployment Systems. Jim Gilliat BakerHughes Houston Texas Presentation Number: SLAP 06

I-Wheel Conveyance Technology Ultra-Flexible, Ultra-Reliable

MAXIMA + Series ROTARY LEVEL CONTROL

R147 WIRELESS ANTI-TWO-BLOCK INDICATOR

ICSI Addressable Disconnect Tool (ADT) Overview

MC 11 EB-2 Power supply cabinet with external bus, AC version

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

BA505C 2-wire 4/20mA manual setpoint station Issue 6

EA500. Installation Instructions Transponder

INSTALLATION GUIDE NP800R

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

QUINT-BUFFER/24DC/24DC/40

4100/ VDC Converter Installation Instructions

Fiber optic converter audio and CAN TA OPERATION MANUAL

* * Agilent Power Distribution Unit (PDU) Installation Guide

INSTALLATION INSTRUCTIONS

MAXIMA+ Series Rotary Level Indicator

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

DET-TRONICS. INSTRUCTIONS Eagle Quantum Heart Beat Monitor EQ2400HBM Eagle 2000 Heart Beat Monitor EA2400HBM /99

Controllers for compressor racks with advanced energy saving. PN08 September 2016

Nevco Message Center Installation Manual Retain this manual in your permanent file. 08/27/ Rev. C

Product Data Sheet. BMS/Graphics Interface. Features

INSTALLATION MANUAL SLI 50 INVERTER

Installation manual CF8-W-Disp-AL

MAXIMA + Series ROTARY LEVEL CONTROL

GT- IRDM-9603 Product description Rev. 2 17/06/2014

Basketball Shot Clock Set LX2180 Manual

DPAK IGBT Motor Drive Reference Design Kit

Operating Instructions VEGAMET 381

PS/IO Circuit Board Retrofit

Improving Data Quality in Challenging Wells. Logging Services. UltraSlim SM. Solving challenges.

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

PowerCore Model TEC-10 Installation Manual

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Blackout Shutter Kits with Breathable Wall Light Traps

MODEL NC105 DIGITAL CODED SQUELCH ENCODER/DECODER INSTRUCTION MANUAL

CHAPTER 3B: ELECTRONIC POWER STEERING

Mounting DIGITAL DISPLAY

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

MODEL NC400 MULTI-FUNCTION TOUCH-TONE DECODER INSTRUCTION MANUAL

MODIFYING THE ACS355 UL TYPE 4X FOR MXXX OPTIONS

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

PWRguard PLUS Spring City Drive Waukesha, WI

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Instruction Sheet Board Style Low Water Cutoff

EL7060 Series SERVICE MANUAL

RTK3 Logic Controller User Manual Revised

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Product Datasheet. Touch screen Part number OPERATOR INTERFACE

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

OMNITERM LPI & LPD Loop Powered Isolators DATASHEET. Model C2063B LPI (single) & C2462A LPD (dual) 4-20mA Loop Powered Isolators.

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

CAN bus switch panels mounted either on the dash or the steering wheel allow for vastly simplified wiring and reduced weight.

Blackout Shutter Kits with Breathable Wall Light Traps

Connecting a Cisco Input Module

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

32-Channel Analogue Input Module Differential Input

SECTION N -- ELECTROSTATIC DISCHARGE (ESD)

ELECTROM INSTRUMENTS

Propeller Project Board USB (#32810)

Product Data Sheet. Hochiki 8 Way I/O Card. Features

Magnum Club Smoke System

Physical description of the safety modules

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

RMB Peripheral Units Installation Guide

Assembly Instructions CT-E Screen Read Board

Overview of the Cisco Wireless Gateway for LoRaWAN

CDD Carbon Dioxide Transmitter

Installation Instructions

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

PT230 PONTOON THRUSTER INSTALLATION MANUAL (PATENT PENDING) VOLUME 1.2, JUNE 2015

Butterfly Laser Diode Mount

AG300 Family CTL01-3A-03, AMP01-2A-02

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment.

4-20mA SERIES Single or Dual Axis MEMS Inclinometer

TT /12b INSTALLATION INSTRUCTIONS. Introduction

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

D Issue D Original. Instruction Manual. Micro Tool Interface

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

CA-A480-A Elevator Controller. Reference & Installation Manual

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Microlok Data Design Records (Addressing, File Control, Checking, and FAT Testing)

Transcription:

ControlFire Titan Division Presentation

Agenda Selective Switch History ControlFire Advanced Switch System Applications System Overview Safety Benefits and Features Developments Track Record Specifications Part Numbers Contact

Selective Switch History 1960 s Rotary Select-Fire Switch Negative power to switch Positive power to fire 10-11 guns per run Dart activation to cut thru wires and seal the tandem sub Skip over capability 1970 s, Dart and Diode Switches Reduce the maintenance issues associated with Rotary Systems Dart would cut thru wires and provide grounding for the detonator Diodes kept the next gun in the string from firing System had a history of not providing positive grounding resulting in miss-run Miss-run required guns to be retrieved from the well for repair 1980 s, EBS Pressure Activated Piston and Diode Switch System uses a pressure activated piston and diodes to provide the connection to the detonator and provide the seal between guns. Switch can be used with gun of any length, size, or shot density Short coming is it is a sequentially operated system, if a failure occurs in the fire sequence the gun must be retrieved from the well for repair

Optimal Selective Switch Solution Added level of Safety detonator is never electrically connected until specific software command is sent Non Sequential Operation independent switch that does not rely on previous gun success Skip over Capabilities provide valuable time savings as perforating operations can continue in the case of a gun misfire Positive Shot Indication confirmation of firing, especially in deep, horizontal well conditions User Friendly System avoid user positive/negative wiring mistakes leading to off depth perforations Eliminate Premature Activation gun flooding causing piston activation leading to off depth perforations Operational Confirmation gun string confirmation throughout the descent into the wellbore providing real time confirmation before critical operations commence

ControlFire Advanced Switch System ControlFire is a digital switch technology that utilizes unique logic to enable selective operations. Applications Selective Perforating Single Trip Plug and Perforating Operations Pumpdown Perforating Tractor Perforating Selective Downhole Tool Control

ControlFire System Overview The ControlFire system consists of four primary components: ControlFire software Perforating Command and Control Panel ControlFire switch VeriFire

ControlFire Software Switch commands fully automated with software controlled command and control panel ControlFire Gun Control operation window Graphical display of each switch status ControlFire Job Setup window User friendly, Graphical User Interface (GUI) software Compatible with Windows XP/7

Perforating Command and Control Panel Perforating Command and Control Panel connects the shooting panel and wireline Fully automated software driven panel Relay disconnect when switch communications are not in progress On/Off key for power off confirmation Gun Communication Limits: Max Voltage: -600VDC Max Current: 100mA Available as a portable box, rack mount or integrated into the Titan Shooting Power Supply rack

ControlFire Switch ControlFire switch circuit consist of 3 primary components: Intelligent Micro Processor Controls the switch position and communicates state Transmitter Receiver Detonator Switch remains in open state until Enable Fire command is received to connect to the detonator/igniter Wireline Switch remains in open state until communication is establish and command is received to close

VeriFire Switch Tester Portable ControlFire switch tester Enables the surface testing of the entire gun string before attaching to the wireline (armed or unarmed) Performs switch safety checks and reports failed switch test Gun string saved to USB drive for upload into ControlFire software for gun string verification User friendly graphical interface Improved confidence before running in hole

ControlFire Gun Wiring To Gun Above To Gun Below

ControlFire Gun/Plug Shoot Wiring To Gun Above To Setting Tool

ControlFire Safety Benefits ControlFire switches add an additional layer of safety to perforating operations: Each ControlFire switch must be activated with specific software command to establish continuity to the detonator/igniter Aids in the prevention of potential surface detonation due to power remaining on the wireline Automatically aborts the firing sequence and shuts down in the event a circuit fault is detected or an inappropriate command is received Automatically times out, if the user does not perform require action in a given time period

ControlFire Operational Benefits Unique switch logic enables skip over capabilities providing valuable time savings in the case of misfire Eliminates potential off-depth perforating events due to improper mechanical switch wiring and/or premature activation due to gun flooding Increased reliability and efficiency of electronic switch over conventional mechanical components Switch communication verification prior to, and during, decent into the wellbore Improved confidence prior to pumping operations Reduced maintenance through fully expendable switch system

ControlFire Features Real time surface shot verification with voltage/current plot Shoot 100+ guns in a single run Integrates into existing perforating gun carrier systems Compatible with resistorized and RF safe detonators Complete event log stored on file Compatible with long wireline cables Can be run in combination with perforating gamma ray tools Reliable operations up to 347 o F (175 o C) No need for dedicated computer at surface Software compatible with Windows XP/7 V/I Plot Shot Verification

RF-Safe System RF-Safe ControlFire Assembly (CFA) ControlFire technology combined with Austin Powder resistorized detonator for completely RF Safe ControlFire Assembly (CFA) Added level of safety No need for radio silence prior to arming Immune to stray voltage up to 500 VDC Immune to human-borne electrostatic discharge energy No need for PX-1 or high voltage firing Low cost compared to EFI and EBW detonators

Operational Summary Four year track record ~750,000 switches run in wells.0005% switch failure rate (better than 1 in 200,000) 2014 Track record: ~170,000 switches run in wells including 100,000 RF-Safe Assemblies 2015 Track record: ~170,000 switches run in wells including 100,000 RF-Safe Assemblies 2016 Track record: ~180,000 switches run in wells including H1 and CFA

ControlFire Specifications

ControlFire Part Numbers Titan Part Numbers Description Part Number ControlFire Switch System ControlFire Switch v1.8 9002-013-120-1.8 Command and Control Panel (portable) 9002-013-510 Command and Control Panel (rack mount) 9002-013-550 VeriFire Panel 9002-013-210 Wireline Switch Simulator Panel 9002-013-610 Panel External Test Block 9002-013-320 Cable Kit 9002-013-017 EBFire Feed Thru w/ Ground 9400-EBTW-WG EBFire Feed Thru 9400-EBTW Retainer Nut ¼ ID w/ Ground 9400-EBRN-WG Retainer Nut ¼ ID 9400-EBRN-250 RF-Safe ControlFire System (with Austin Powder detonator selection) RF-Safe Switch with A-85 Detonator DETO-CFA-A85-T RF-Safe Switch with A-96L Detonator DETO-CFA-A96L-T RF-Safe Switch with A-105 Detonator DETO-CFA-A105-T RF-Safe Switch with A-105-100 Detonator DETO-CFA-A105100-T RF-Safe Switch with A-140 Detonator DETO-CFA-A140-T RF-Safe Switch with A- 140F Detonator DETO-CFA-A140F-T RF-Safe Switch with A- 140S Detonator DETO-CFA-A140S-T Titan Shooting Power Supply ControlFire Shooting Power Supply 9002-013-810-1

Contact Website www.hunting-intl.com/titan Sales sales.titan@hunting-intl.com Houston, TX (281) 448-2200 Corporate Office Pampa, TX (806) 665-3781 Technical Support 24/7 support.titan@hunting-intl.com